• Title/Summary/Keyword: Success Rates

Search Result 550, Processing Time 0.03 seconds

Experiences with Endoscopic Interventions for Variceal Bleeding in Children with Portal Hypertension: A Single Center Study

  • Kim, Seung Jin;Oh, Seak Hee;Jo, Jin Min;Kim, Kyung Mo
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.16 no.4
    • /
    • pp.248-253
    • /
    • 2013
  • Purpose: The aim of this study was to compare the efficacy and safety of band ligation and injection sclerotherapy in the endoscopic treatment of children with variceal bleeding. Methods: The study population included 55 children, all of whom were treated at the time of endoscopic diagnosis of esophageal varices at Asan Medical Center, Seoul, Korea, between January 1994 and January 2011. The primary outcomes included initial success rates and duration of hemostasis after endoscopic management (band ligation vs. injectionsclerotherapy). Results: The mean age was $6.7{\pm}5.2$ years and the mean follow-up time was $5.4{\pm}3.7$ years. The most common cause of esophageal varices was biliary atresia. Of 55 children with acute variceal bleeding, 39 had band ligation and 16 had injection sclerotherapy. No differences between groups were observed in terms of the size, location, and presence of red color sign. The success rates of band ligation and sclerotherapy in the control of acute bleeding episodes were 89.7% and 87.5%. The mean duration of hemostasis after endoscopic intervention was $13.2{\pm}25.1$ months. After one year, 19 of 39 patients (48.7%) treated with band ligation and 7 of 16 patients (43.8%) with injection sclerotherapy had experienced rebleeding episodes. Complications after the procedures were observed in 10.3% and 18.8% of children treated with band ligation and injection sclerotherapy. Conclusion: The results of our current study suggest that band ligation and injection sclerotherapy are equally efficient treatments for the control of acute variceal bleeding and prevention of rebleeding.

Optimal Cardiac Magnetic Resonance Contrast-Enhanced Timing Robust Angiography (CMR-CENTRA) for the Three-Dimensional Reconstruction of the Bilateral Atria in the Electroanatomic Mapping (EAM) of Atrial Fibrillation

  • Kim, Jun Seong;Oh, Yu-Whan;Shim, Jaemin;Kim, Young-Hoon;Hwang, Sung Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.3
    • /
    • pp.131-138
    • /
    • 2017
  • Purpose: To optimize the timing of scans using cardiac magnetic resonance contrast-enhanced timing robust angiography (CMR-CENTRA) for electroanatomic mapping (EAM) of the right atrium (RA) and left atrium (LA) in patients with atrial fibrillation (AF). Materials and Methods: Fifty patients with AF (38 men; mean age, $59.6{\pm}9.3years$) underwent CMR-CENTRA in preparation for EAM. The CMR-CENTRA data were acquired at five different scan times: 0 seconds, 5 seconds, 10 seconds, 15 seconds, and 20 seconds after an intravenous injection of contrast media. To evaluate the degree of contrast enhancement, right atrial relative contrast (RA-RC) and left atrial relative contrast (LA-RC) on the CMR-CENTRA scans were assessed at each time point. The three-dimensional (3D) reconstruction of the RA and LA for the EAM system was performed using the CMR-CENTRA data. Results: A CMR-CENTRA at a scan time of 10 seconds showed significantly greater LA-RC (P < 0.05) compared with all other scan times. A CMR-CENTRA at a scan time of 15 seconds showed significantly greater RA-RC (P < 0.05) compared with all other scan times. In the 3D reconstruction of the RA, the success rates of CMR-CENTRA at scan times of 10 seconds and 15 seconds were 18% and 100%, respectively. In the 3D reconstruction of the LA, the success rates of CMR-CENTRA at 10- and 15-second scan times were 100%. Conclusion: The CMR-CENTRA data acquired at 15 seconds after the injection of contrast media is appropriate for the preparation of an EAM system that is focused on the RA and LA in patients with AF.

Current Status of Fluoroquinolone Use for Treatment of Tuberculosis in a Tertiary Care Hospital in Korea

  • Kang, Bo Hyoung;Jo, Kyung-Wook;Shim, Tae Sun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.80 no.2
    • /
    • pp.143-152
    • /
    • 2017
  • Background: Fluoroquinolones are considered important substitutes for the treatment of tuberculosis. This study investigates the current status of fluoroquinolone for the treatment of tuberculosis. Methods: In 2009, a retrospective analysis was performed at one tertiary referral center for 953 patients diagnosed with tuberculosis. Results: A total of 226 patients (23.6%), who received fluoroquinolone at any time during treatment for tuberculosis, were enrolled in this study. The most common reasons for fluoroquinolone use were adverse events due to other anti-tuberculosis drugs (52.7%), drug resistance (23.5%), and underlying diseases (16.8%). Moxifloxacin (54.0%, 122/226) was the most commonly administered fluoroquinolone, followed by levofloxacin (36.3%, 82/226) and ofloxacin (9.7%, 22/226). The frequency of total adverse events from fluoroquinolone-containing anti-tuberculosis medication was 22.6%, whereas fluoroquinolone-related adverse events were estimated to be 2.2% (5/226). The most common fluoroquinolone-related adverse events were gastrointestinal problems (3.5%, 8/226). There were no significant differences in the treatment success rate between the fluoroquinolone and fluoroquinolone-$na{\ddot{i}}ve$ groups (78.3% vs. 78.4%, respectively). Conclusion: At our institution, fluoroquinolones are commonly used for the treatment of both multidrug-resistant tuberculosis and susceptible tuberculosis, especially as a substitute for adverse event-related drugs. Considering the low adverse event rates and the comparable treatment success rates, fluoroquinolones seem to be an invaluable drug for the treatment of tuberculosis.

Clinical Analysis Comparing Efficacy between a Distal Filter Protection Device and Proximal Balloon Occlusion Device during Carotid Artery Stenting

  • Lee, Jong Hyeok;Sohn, Hee Eon;Chung, Seung Young;Park, Moon Sun;Kim, Seong Min;Lee, Do Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.4
    • /
    • pp.316-320
    • /
    • 2015
  • Objective : The main concern during transfemoral carotid artery stenting (CAS) is preventing cerebral embolus dislodgement. We compared clinical outcomes and intraprocedural embolization rates of CAS using a distal filter protection device or proximal balloon occlusion device. Methods : From January 2011 to March 2015, a series of 58 patients with symptomatic or asymptomatic internal carotid artery stenosis ${\geq}70%$ were treated with CAS with embolic protection device in single center. All patients underwent post-CAS diffusion-weighted magnetic resonance imaging (DW-MRI) to detect new ischemic lesions. We compared clinical outcomes and postprocedural embolization rates. Results : CAS was performed in all 61 patients. Distal filter protection success rate was 96.6% (28/29), whose mean age was 70.9 years, and mean stenosis was 81%. Their preprocedural infarction rate was 39% (11/28). Subsequent DW-MRI revealed 96 new ischemic lesions in 71% (20/28) patients. In contrast, the proximal balloon occlusion device success rate was 93.8% (30/32), whose mean age was 68.8 years and mean stenosis was 86%. Preprocedure infarction rate was 47% (14/30). DW-MRI revealed 45 new ischemic lesions in 57% (17/30) patients. Compared with distal filter protection device, proximal balloon occlusion device resulted in fewer ischemic lesions per patient (p=0.028). In each group, type of stent during CAS had no significant effect on number of periprocedural embolisms. Only 2 neurologic events occurred in the successfully treated patients (one from each group). Conclusion : Transfemoral CAS with proximal balloon occlusion device achieves good results. Compared with distal filter protection, proximal balloon occlusion might be more effective in reducing cerebral embolism during CAS.

Efficacy of Transradial Cerebral Angiography in the Elderly

  • Park, Jung-Hyun;Kim, Dae-Yong;Kim, Jin-Wook;Park, Yong-Seok;Seung, Won-Bae
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.4
    • /
    • pp.213-217
    • /
    • 2013
  • Objective : Transradial angiography has become popular among many cardiologists as a diagnostic and therapeutic tool. However, transradial cerebral angiography is not utilized to the same extent. The purpose of this study is to present our experience regarding the usefulness of transradial cerebral angiography, especially in elderly patients. Methods : Between May 2011 and February 2012, a total of 126 cerebral angiographies were performed via a transradial approach in a single center. Of them, only 47 patients were over 60 years old. In our institution, we shifted the initial access from the right femoral artery to the right radial artery in all patients requiring cerebral angiography in 2011. We did not attempt radial access in 40 cases for variable reasons. Results : The procedural success rate was 92.2%. We have four failures of transradial angiography; two because of loop formations of the radial and brachial artery and two due to multiple puncture failures. All supra-aortic vessels were successfully catheterized. However, the selective catheterization rates of the left side distal vessels were lower, as success rates were 89.7% for the right internal carotid artery and 75% for the left internal carotid artery. Procedure-related vascular complications, such as puncture site hematoma, hand ischemia, pseudoaneurysm, arteriovenous fistula and arterial dissection were not observed in our series. However, intraprocedural thrombosis developed in one patient, which was resolved completely by intraarterial thrombolytic agents. Conclusion : With advancing patient's age, we believe that transradial cerebral angiography is a useful tool to decrease patient's discomfort and more effectively manage the vessel tortuosity.

Clinical Application of Transcatheter Arterial Chemoembolization Combined with Synchronous C-arm Cone-Beam CT Guided Radiofrequency Ablation in treatment of Large Hepatocellular Carcinoma

  • Wang, Zhi-Jun;Wang, Mao-Qiang;Duan, Feng;Song, Peng;Liu, Feng-Yong;Wang, Yan;Yan, Jie-Yu;Li, Kai;Yuan, Kai
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.3
    • /
    • pp.1649-1654
    • /
    • 2013
  • Objective: This work aimed to evaluate the safety and clinical efficacy of transcatheter arterial chemoembolization (TACE) combined with c-arm cone-beam CT guided synchronous radiofrequency ablation (RFA) in treatment of large hepatocellular carcinoma (HCC). Methods: 21 patients with large HCC were studied from January 2010 to March 2012. TACE combined with synchronous C-arm cone-beam CT guided RFA were performed on a total of 25 lesions. Conventional imaging examination (CEUS, enhanced CT or MRI) and AFP detection were regularly conducted to evaluate the technical success rate of combined treatment, complications, treatment response, time without disease recurrence and survival rate. Results: The technical success rate of combined treatment was 100%, without any significant complication. After 1 month, there were 19 cases with complete response and 2 cases with partial response, with an complete response rate of 90.4% (19/21) and a clinical effective rate of 100% (21/21). The complete response rates of single nodular lesions (100%, 17/17) was significantly higher than that of multiple nodular lesions (50%, 2/4) (P<0. 05). During 2 to 28 months of follow-up, in 19 cases with complete response, the average time without disease recurrence was $10.8{\pm}6$ months. The total survival rates of 6, 12 and 18 months in 21 patients were 100%, respectively. Conclusion: TACE combined with synchronous C-arm CT guided RFA is safe and effective for treatment of large HCC. The treatment efficacy for single nodular lesion is better than that for multiple nodular lesions.

ON THE BONE TISSUE REACTION TO IMPLANTS WITH DIFFERENT SURFACE TREATMENT METHODS (임플랜트 표면 처리 방법에 따른 골조직 반응에 대한 연구)

  • Kim, Yong-Jae;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.1
    • /
    • pp.71-84
    • /
    • 2007
  • Statement of problem: Implant surface characteristics plays an important role in clinical success and many studies have been made for improvement of success by changing surface roughness. Purpose: Appropriate increase of surface roughness increases the activity of osteoblast and enhance contact and retention between bone and implant. Material and method- Machined, SLA and RBM surface implants, which are the most commonly used implants were implanted into the tibia of rabbits and after 1 week, 4 weeks, 8 weeks and 12 weeks there were histologic and histomorphometric analysis and study for bone gradient and change of Ca/P ratio using EDS(Energy Dispersive X-ray Spectroscope). Results: Comparison of bone-implant contact showed no significant difference among each implant. In comparison of bone area rates, SLA showed higher value with significant difference at 1 week and 4 weeks, and SLA and RBM at 8 weeks than Machined implant (p<0.05). In analysis of bone constituents with EDS, titanium was specifically detected in new bones and the rates were constant by surface treatment method or period. In case of Ca/P ratio, according to surface treatment method, each group showed significant difference. Lots of old bone fragments produced during implantation remained on the rough surface of RBM implant surface and each group showed histological finding with active synthesis of collagen fibers until 12 weeks. In transmission electronic microscopic examination of sample slice after elapse of twelve weeks, tens nm of borderline (lamina limitans like dense line)was seen to contact the bone, on the interface between bone and implant. Conclusion: SLA and RBM implant with rough surface shows better histomorphometrical result and the trend of prolonged bone formation and maturation in comparison with Machined implant. In addition, implant with rough surface seems to be helpful in early stage bone formation due to remaining of old bone fragments produced in implantation. From the results above, it is considered to be better to use implant with rough surface in implantation.

7-mm-long dental implants: retrospective clinical outcomes in medically compromised patients

  • Nguyen, Truc Thi Hoang;Eo, Mi Young;Cho, Yun Ju;Myoung, Hoon;Kim, Soung Min
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.45 no.5
    • /
    • pp.260-266
    • /
    • 2019
  • Objectives: Dental implants shorter than 8 mm, called short dental implants (SDIs), have been considered to have a lower success rate than standard length implants. But recent studies have shown that SDIs have a comparable success rate, and implant diameter was more important for implant survival than implant length. Also, SDIs have many advantages, such as no need for sinus lifting or vertical bone grafting, which may limit use in medically compromised patients. Materials and Methods: In this study, 33 patients with 47 implants 7-mm long were examined over the last four years. All patients had special medical history and were categorized into 3 groups: systemic disorders, such as diabetes mellitus (controlled or uncontrolled), mental disability, and uncontrolled hypertension; oral cancer ablation with reconstruction, with or without radiotherapy; diverse osteomyelitis, such as osteoradionecrosis and bisphosphonate-related osteonecrosis of the jaw. Most of these patients have insufficient residual bone quality due to mandible atrophy or sinus pneumatization. Results: The implant diameters were 4.0 (n=38), 4.5 (n=8), and 5.0 mm (n=1). Among the 47 implants placed, 2 implants failed before the last followup. The survival rate of 7-mm SDIs was 95.74% from stage I surgery to the last follow-up. Survival rates did not differ according to implant diameter. The mean marginal bone loss (MBL) at 3 months, 1 and 2 years was significantly higher than at implant installation, and the MBL at 1 year was also significantly higher than at 3 months. MBL at 1 and 2 years did not differ significantly. Conclusion: Within the limitations of the present study, the results indicate that SDIs provide a reliable treatment, especially for medically compromised patients, to avoid sinus lifting or vertical bone grafting. Further, long-term follow-up is needed.

Paclitaxel-Coated Balloon versus Plain Balloon Angioplasty for Dysfunctional Autogenous Radiocephalic Arteriovenous Fistulas: A Prospective Randomized Controlled Trial

  • Jong Woo Kim;Jeong Ho Kim;Sung Su Byun;Jin Mo Kang;Ji Hoon Shin
    • Korean Journal of Radiology
    • /
    • v.21 no.11
    • /
    • pp.1239-1247
    • /
    • 2020
  • Objective: To report the mid-term results of a single-center randomized controlled trial comparing drug-coated balloon angioplasty (DBA) and plain balloon angioplasty (PBA) for the treatment of dysfunctional radiocephalic arteriovenous fistulas (RCAVFs). Materials and Methods: In this prospective study, 39 patients (mean age, 62.2 years; 21 males, 18 females) with RCAVFs failing due to juxta-anastomotic stenosis were randomly assigned to undergo either both DBA and PBA (n = 20, DBA group) or PBA alone (n = 19, PBA group) between June 2016 and June 2018. Primary endpoints were technical and clinical success and target lesion primary patency (TLPP); secondary outcomes were target lesion secondary patency (TLSP) and complication rates. Statistical analysis was performed using the Kaplan-Meier product limit estimator. Results: Demographic data and baseline clinical characteristics were comparable between the groups. Technical and clinical success rates were 100% in both groups. There was no significant difference between the groups in the mean duration of TLPP (DBA group: 26.7 ± 3.6 months; PBA group: 27.0 ± 3.8 months; p = 0.902) and TLSP (DBA group: 37.3 ± 2.6 months; PBA group: 40.4 ± 1.5 months; p = 0.585). No procedural or post-procedural complications were identified. Conclusion: Paclitaxel-coated balloon use did not significantly improve TLPP or TLSP in the treatment of juxta-anastomotic stenosis of dysfunctional RCAVFs.

Clinical Analysis of 51 Cases of Free Flap Reconstruction after Ablative Surgery of Head and Neck Cancer (두경부암종 수술 후 결손부위 재건에 사용된 유리피판술 51예의 고찰)

  • Lee, Seung-Won;Kim, Jae-Wook;Kim, Yong-Bae;Tak, Min-Sung;Shi, Ho-Sung;Chang, Hyuck-Soon;Oh, Cheon-Hwan;Park, Jin-Gyu;Koh, Yoon-Woo
    • Korean Journal of Head & Neck Oncology
    • /
    • v.23 no.1
    • /
    • pp.26-31
    • /
    • 2007
  • Background and Objectives:Microvascular free flap reconstruction has been revolutionized in last two decades, and became a standard option in the reconstruction of head and neck defects. We intended to review our experiences of 51 microvascular free flap for head and neck defects during 5-year period and to analyze the types of flaps according to primary sites, success and complication rates. Subjects and Methods:From Oct. 2001 through Dec. 2005, fifty one free flap reconstructions were performed in forty nine patients at ENT department of Soonchunhyang university bucheon hospital. Primary sites, pathology, T-stage, operative time, time interval of oral feeding, and various reconstructive factors such as recipient and donor vessels, free flap related complications, failure rates and salvage rates were retrospectively analyzed. The relation between complication rates and preoperative risk factors were statistically analyzed. Results:Methods of reconstruction were radial forearm free flap(RFFF)(n=28, 54.9%), anterolateral thigh free flaps(n=9, ALTFF)(17.6%), rectus abdominis free flap(n=7, RAFF)(13.7%), jejunal free flap(n=5, JFF)(9.8%), and miscellanous(n=2, 4.0%) in order. In free flap related complications, failure of free flap occurred in seven cases(13.7%) and pharyngocutaneous fistula occurred in five cases(9.8%) among fifty one free flaps. The overall success rate of free flaps was 86.3%. Salvage of free flaps was possible only one among eight cases(12.5%). In positive preoperative risk factor groups, failure of free flap was higher than in negative risk factor group. However, it was not statistically significant. Conclusion:We confirmed that free flap reconstructions are highly versatile and reliable options for use in the reconstruction of various soft tissue defects of the head and neck. Free flaps have gained great popularity given its versatility, ability for a two-team approach, and minimal donor site morbidity. However, complications related to microvascular surgery may be overcome by increased surgical experience and by intensive flap monitoring in early postoperative period.