References
- Renouard F, Nisand D. Impact of implant length and diameter on survival rates. Clin Oral Implants Res 2006;17 Suppl 2:35-51. https://doi.org/10.1111/j.1600-0501.2006.01349.x
- Jain N, Gulati M, Garg M, Pathak C. Short implants: new horizon in implant dentistry. J Clin Diagn Res 2016;10:ZE14-7.
- Al-Hashedi AA, Taiyeb Ali TB, Yunus N. Short dental implants: an emerging concept in implant treatment. Quintessence Int 2014;45:499-514. https://doi.org/10.3290/j.qi.a31539
- Nisand D, Renouard F. Short implant in limited bone volume. Periodontol 2000 2014;66:72-96. https://doi.org/10.1111/prd.12053
- Sennerby L, Roos J. Surgical determinants of clinical success of osseointegrated oral implants: a review of the literature. Int J Prosthodont 1998;11:408-20.
- Wyatt CC, Zarb GA. Treatment outcomes of patients with implantsupported fixed partial prostheses. Int J Oral Maxillofac Implants 1998;13:204-11.
- Srinivasan M, Vazquez L, Rieder P, Moraguez O, Bernard JP, Belser UC. Efficacy and predictability of short dental implants (<8 mm): a critical appraisal of the recent literature. Int J Oral Maxillofac Implants 2012;27:1429-37.
- Karthikeyan I, Desai SR, Singh R. Short implants: a systematic review. J Indian Soc Periodontol 2012;16:302-12. https://doi.org/10.4103/0972-124X.100901
- Lemos CA, Ferro-Alves ML, Okamoto R, Mendonca MR, Pellizzer EP. Short dental implants versus standard dental implants placed in the posterior jaws: a systematic review and meta-analysis. J Dent 2016;47:8-17. https://doi.org/10.1016/j.jdent.2016.01.005
- Benlidayi ME, Ucar Y, Tatli U, Ekren O, Evlice B, Kisa HI, et al. Short implants versus standard implants: midterm outcomes of a clinical study. Implant Dent 2018;27:95-100. https://doi.org/10.1097/ID.0000000000000710
- Esfahrood ZR, Ahmadi L, Karami E, Asghari S. Short dental implants in the posterior maxilla: a review of the literature. J Korean Assoc Oral Maxillofac Surg 2017;43:70-6. https://doi.org/10.5125/jkaoms.2017.43.2.70
- Pierrisnard L, Renouard F, Renault P, Barquins M. Influence of implant length and bicortical anchorage on implant stress distribution. Clin Implant Dent Relat Res 2003;5:254-62. https://doi.org/10.1111/j.1708-8208.2003.tb00208.x
- Anitua E, Tapia R, Luzuriaga F, Orive G. Influence of implant length, diameter, and geometry on stress distribution: a finite element analysis. Int J Periodontics Restorative Dent 2010;30:89-95.
- Chen H, Liu N, Xu X, Qu X, Lu E. Smoking, radiotherapy, diabetes and osteoporosis as risk factors for dental implant failure: a meta-analysis. PLoS One 2013;8:e71955. https://doi.org/10.1371/journal.pone.0071955
- Moy PK, Medina D, Shetty V, Aghaloo TL. Dental implant failure rates and associated risk factors. Int J Oral Maxillofac Implants 2005;20:569-77.
- Guobis Z, Pacauskiene I, Astramskaite I. General diseases influence on peri-implantitis development: a systematic review. J Oral Maxillofac Res 2016;7:e5.
- Liddelow G, Klineberg I. Patient-related risk factors for implant therapy. A critique of pertinent literature. Aust Dent J 2011;56:417-26; quiz 441. https://doi.org/10.1111/j.1834-7819.2011.01367.x
- Renvert S, Aghazadeh A, Hallstrom H, Persson GR. Factors related to peri-implantitis - a retrospective study. Clin Oral Implants Res 2014;25:522-9.
- Kasai T, Pogrel MA, Hossaini M. The prognosis for dental implants placed in patients taking oral bisphosphonates. J Calif Dent Assoc 2009;37:39-42.
- Galindo-Moreno P, Leon-Cano A, Ortega-Oller I, Monje A, O Valle F, Catena A. Marginal bone loss as success criterion in implant dentistry: beyond 2 mm. Clin Oral Implants Res 2015;26:e28-34. https://doi.org/10.1111/clr.12324
- Diz P, Scully C, Sanz M. Dental implants in the medically compromised patient. J Dent 2013;41:195-206. https://doi.org/10.1016/j.jdent.2012.12.008
- Grant BT, Pancko FX, Kraut RA. Outcomes of placing short dental implants in the posterior mandible: a retrospective study of 124 cases. J Oral Maxillofac Surg 2009;67:713-7. https://doi.org/10.1016/j.joms.2008.11.004
- Barrowman RA, Wilson PR, Wiesenfeld D. Oral rehabilitation with dental implants after cancer treatment. Aust Dent J 2011;56:160-5. https://doi.org/10.1111/j.1834-7819.2011.01318.x
- Renouard F, Nisand D. Short implants in the severely resorbed maxilla: a 2-year retrospective clinical study. Clin Implant Dent Relat Res 2005;7 Suppl 1:104-10. https://doi.org/10.1111/j.1708-8208.2005.tb00082.x
- Jemt T, Linden B, Lekholm U. Failures and complications in 127 consecutively placed fixed partial prostheses supported by Branemark implants: from prosthetic treatment to first annual checkup. Int J Oral Maxillofac Implants 1992;7:40-4.
- Becker W, Becker BE, Alsuwyed A, Al-Mubarak S. Long-term evaluation of 282 implants in maxillary and mandibular molar positions: a prospective study. J Periodontol 1999;70:896-901. https://doi.org/10.1902/jop.1999.70.8.896
- Lee JH, Frias V, Lee KW, Wright RF. Effect of implant size and shape on implant success rates: a literature review. J Prosthet Dent 2005;94:377-81. https://doi.org/10.1016/j.prosdent.2005.04.018
- Morand M, Irinakis T. The challenge of implant therapy in the posterior maxilla: providing a rationale for the use of short implants. J Oral Implantol 2007;33:257-66. https://doi.org/10.1563/1548-1336(2007)33[257:TCOITI]2.0.CO;2
- Mohajerani H, Roozbayani R, Taherian S, Tabrizi R. The risk factors in early failure of dental implants: a retrospective study. J Dent (Shiraz) 2017;18:298-303.
- Bratu E, Chan HL, Mihali S, Karancsi O, Bratu DC, Fu JH, et al. Implant survival rate and marginal bone loss of 6-mm short implants: a 2-year clinical report. Int J Oral Maxillofac Implants 2014;29:1425-8. https://doi.org/10.11607/jomi.3729
- Monje A, Chan HL, Fu JH, Suarez F, Galindo-Moreno P, Wang HL. Are short dental implants (<10 mm) effective? A meta-analysis on prospective clinical trials. J Periodontol 2013;84:895-904. https://doi.org/10.1902/jop.2012.120328
Cited by
- Assessment of the Survival Rate of Short Dental Implants in Medically Compromised Patients vol.21, pp.8, 2020, https://doi.org/10.5005/jp-journals-10024-2854
- Prognosis of implants placed simultaneously with periodontal surgery of the adjacent tooth vol.44, pp.2, 2019, https://doi.org/10.21851/obr.44.02.202006.83
- Effect of Variable Implant Tip Distances on Stress Distribution around the Mental Foramen: A Finite Element Analysis vol.9, pp.4, 2019, https://doi.org/10.3889/oamjms.2021.6407