• 제목/요약/키워드: Subway station platform

검색결과 152건 처리시간 0.025초

지하공간의 공기 질 개선을 위한 지하철 터널 내 열차풍의 수치 해석적 연구 (A NUMERICAL ANALYSIS OF TRAIN-WIND IN THE SUBWAY TUNNEL FOR THE IMPROVEMENT OF THE OF UNDERGROUND SPACE AIR QUALITY)

  • 이준호;쥬레바 막슈다;정상현;송동주
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2011년 춘계학술대회논문집
    • /
    • pp.523-528
    • /
    • 2011
  • Subway becomes more and more main transportation in major cities. Air pollution in the subway platforms is decreased; however, dust flow inside subway tunnel and train is increased by installing Platform Screen Door. Airflow inside subway tunnel is observed using computational method in this study The airflow characteristics around ventilation shafts and inside the tunnel is studied following the train movement, while the train moves from existing Miasamgeori station to Gireum station ANSYS CFX V12.0.l and ICEM CFD V12.0.l are used to compute the airflow inside the subway tunnel.

  • PDF

기술적 해결을 통한 위험관리의 가능성과 한계: 지하철 스크린도어를 중심으로 (The Possibility and Limit of Risk Management through Technological Fix: A Case Study into the Platform Screen Door (PSD))

  • 강윤재
    • 과학기술학연구
    • /
    • 제10권2호
    • /
    • pp.77-105
    • /
    • 2010
  • 이 글은 지하철 위험의 해결책으로 제시된 스크린도어를 대상으로 "기술적 해결"(technological fix)의 가능성과 한계를 검토하고 있다. 지하철 위험은 그 유형에 따라 모두 다섯 종류―"전철운행 사고", "역사 내 사고", "승강장 사고", "지하의 공간적 위험", "범죄 및 테러의 위험"―로 분류할 수 있는데, 가장 중요한 것은 궤도와 역사의 접촉면에 위치한 승강장에서 발생하는 승강장 사고이다. 스크린도어는 승강장 사고를 예방할 수 있는 효과적인 기술적 수단으로 여겨진다. 여기에는 사고를 기술적 수단을 통해 해결하려는 기술적 해결의 이데올로기가 강하게 작용한다. 신설되는 역이 아니라 기존 역의 승강장에 스크린도어를 설치하는 것이 세계적으로 유래를 찾기 힘든 경우라는 사실이 이를 잘 보여준다. 스크린도어는 현실적 수단으로서 가시적 효과를 낳았지만 예상치 못한 비가시적 위험을 가중시킨 측면도 없지 않다. 승강장 내부, 특히 출퇴근 환승역 승강장에서 화재가 발생했을 때, 스크린도어는 승객의 탈출로를 차단하는 "통곡의 벽"으로 돌변할 수 있다. 기술적 해결에 대한 지나친 기대와 의존은 금물이며, 그 한계에 대한 성찰이 요구되는 이유이다.

  • PDF

서울시 지하철 승강장의 스크린도어 설치 전·후 PM10 오염원의 기여도 비교 연구 (A Comparative Study on PM10 Source Contributions in a Seoul Metropolitan Subway Station Before/After Installing Platform Screen Doors)

  • 이태정;전재식;김신도;김동술
    • 한국대기환경학회지
    • /
    • 제26권5호
    • /
    • pp.543-553
    • /
    • 2010
  • Almost five million citizens a day are using subways as a means of traffic communication in the Seoul metropolitan. As the subway system is typically a closed environment, indoor air pollution problems frequently occurs and passengers complain of mal-health impact. Especially $PM_{10}$ is well known as one of the major pollutants in subway indoor environments. The purpose of this study was to compare the indoor air quality in terms of $PM_{10}$ and to quantitatively compare its source contributions in a Seoul subway platform before and after installing platform screen doors (PSD). $PM_{10}$ samples were collected on the J station platform of Subway Line 7 in Seoul metropolitan area from Jun. 12, 2008 to Jan. 12, 2009. The samples collected on membrane filters using $PM_{10}$ mini-volume portable samplers were then analyzed for trace metals and soluble ions. A total of 18 chemical species (Ba, Mn, Cr, Cd, Si, Fe, Ni, Al, Cu, Pb, Ti, $Na^+$, $NH_4^+$, $K^+$, $Mg^{2+}$, $Ca^{2+}$, $Cl^-$, and ${SO_4}^{2-}$) were analyzed by using an ICP-AES and an IC after performing proper pre-treatments of each sample filter. Based on the chemical information, positive matrix factorization (PMF) model was applied to identify the source of particulate matters. $PM_{10}$ for the station was characterized by three sources such as ferrous related source, soil and road dust related source, and fine secondary aerosol source. After installing PSD, the average $PM_{10}$ concentration was decreased by 20.5% during the study periods. Especially the contribution of the ferrous related source emitted during train service in a tunnel route was decreased from 59.1% to 43.8% since both platform and tunnel areas were completely blocked by screen doors. However, the contribution of the fine secondary aerosol source emitted from various outside combustion activities was increased from 14.8% to 29.9% presumably due to ill-managed ventilation system and confined platform space.

지하역사 승강장 열환경 개선을 위한 연구 (제2보: 도입외기온도에 따른 승강장 열환경) (The study for thermal environment improvement at subway station platform (Part 2: Thermal environment according to supply outdoor temperature))

  • 김회률;김동규;금종수;정용현;김종열;김민수
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.561-564
    • /
    • 2009
  • This study is to examine the possibility of pre-cooling at platform. Through measurement of the thermal environment of Bujeon Subway platforms, review the potential use of ground-water and night purge. The results of this research can improve the thermal environment pre-cooling of the design.

  • PDF

지하철 역내 가스 검출 원격 모니터링 시스템 구현 (Development of a remote monitoring system for gas detection at the subway station)

  • 박용만;김희식;김규식;이문규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.439-441
    • /
    • 2007
  • The seoul metropolitan subway has installed 8 lines and about 500 stations to transport 5 million passengers everyday. The underground air pollution level in the subway stations is very severe status, which is very harmful to the commutators and its personals. Although subway roles as such a massive and huge transportation system, the subway doesn't adapt yet any real-time air monitoring system. They have only some hand-held type detector equipments for monitoring air pollution. Therefore subway passengers are exposed to the harmful air pollution environment. The most harmful environmental parameters among the air pollution are known as the dust and sound noise dB level in the subway station. Because the dust is consisted of very small particles, we can't see them easily in dark condition on the platform, but it is very harmful. The monitoring system for air pollution is developed using embedded system attached with 6 different environmental sensors. This system monitors air pollution of dust sound noise, gas, temperature, humidity, inflammable gas, toxic gas in the subway ?station. The sensor unit of the ARM-CPU board and sensor transmits real time environmental data to the main server using Zigbee wireless communication module and TCP/IP network. The main control server receives and displays the real-time environmental data, and it send alarms to the personals when high level value.

  • PDF

서울시 일부 지하철역 내 분포하는 부유 세균 및 입자상 오염물질 평가 (Assessment of Airborne Bacteria and Particulate Matters Distributed in Seoul Metropolitan Subway Stations)

  • 김기연;박재범;김치년;이경종
    • 한국환경보건학회지
    • /
    • 제32권4호
    • /
    • pp.254-261
    • /
    • 2006
  • In activity areas of subway workers and passengers in Seoul metropolitan subway lines 1-4, mein concentrations of airborne bacteria were relatively higher in workers' bedroom and station precinct whereas concentrations of particulate matters, $PM_{10}$ and $PM_{2.5}$, were relatively higher in platform, inside train and driver's seat as compared with other activity areas. This result indicates that little correlation between airborne bacteria and particulate matters was found, which assumed that most airborne particulate matters distributed in subway consisted of mainly inorganic dust like a metal particles. Mean concentrations of $PM_{10}$ and $PM_{2.5}$ in station precinct and platform exceeded the threshold limit value ($PM_{10}:150{\mu}g/m^3,\;PM_{2.5}:65{\mu}g/m^3$) but those in station office and ticket office were below it. The genera identified in all the activity areas of subway over 5% detection rate were Staphylococcus, Micrococcus, Bacillus and Corynebacterium, of which Staphylococcus and Micrococcus covered over 50% of total airborne bacteria and were considered as predominant genera distributed in subway.

지하철 승강장 급배기 조건에 따른 화재 위험성 평가 (Fire Risk Assessment for Subway Station According to Supply and Exhaust Conditions)

  • 김하영;이동호;김정엽
    • 한국화재소방학회논문지
    • /
    • 제22권5호
    • /
    • pp.29-34
    • /
    • 2008
  • 본 연구에서는 대피자의 최적 배연조건 확립을 위하여 CFD모델을 이용한 수치해석을 통해 지하철 승강장 내에서의 화재 시 다양한 배연조건에서의 화재 위험성을 검토하였다. 결과로 스크린도어를 설치한 경우가 설치하지 않은 경우보다 온도의 상승폭이 최대 $65.37%{\sim}74.97%$ 낮게 나타났다. 또한 급기나 압인배기시 승강장에 난류가 발생함에 따라 온도 및 연기층이 교란되어 하락됨에 따라 탈출시 위험을 유발할 수 있는 것으로 판단되었다. 따라서 배연용량 및 승강장 공간 설정시 배연조건에 따른 화재 특성을 고려한 설계가 필요하다.

지하철 역사 형상을 고려한 PSD 비정상 풍압해석 (Unsteady Wind Pressure Analysis on PSD Considering Subway Station Configurations)

  • 김유성;김요한;신광복;이은규;김동현
    • 한국철도학회논문집
    • /
    • 제11권1호
    • /
    • pp.13-18
    • /
    • 2008
  • 본 연구에서는 열차와 지하철 역사 형상긴의 유통 흐름에 대한 상호작용을 고려하여 승강장 스크린도어(PSD)봐 비정상 풍압해석을 수행하였다. PSD의 주목적은 열차가 역사 안으로 진입할 때, 인명사고를 예방하고 풍압, 오염된 분진, 소음 등을 차단하는데 있다. PSD에 대한 비정상 풍압수준을 정확하게 예측하기 위하여 이동격자법을 활용한 전산유체역학 기법이 적용되었다. 개방형 및 밀폐형 역사가 고려되었으며, 열차가 역사를 통과하는 경우와 역사에서 멈추는 경우에 대한 풍압 수준을 상호 비교하였다.

부산지역 지하역사의 최근 3년간(2015~2017년) CO, CO2, NO2 농도의 특성 (Characteristics of CO, CO2, and NO2 Concentrations at Subway Stations in Busan for 3 Years (2015~2017))

  • 전병일
    • 한국환경과학회지
    • /
    • 제28권7호
    • /
    • pp.595-606
    • /
    • 2019
  • This research investigated the characteristics of CO, $CO_2$, and $NO_2$ concentrations at main subway stations in Busan. The annual mean CO concentrations at the Suyeong and Nampo stations were 0.75 ppm and 0.48 ppm, respectively. Annual $CO_2$ concentration at the Seomyeon 1- platform was 649 ppm. The $NO_2$ concentrations at the Seomyeon 2- waiting room and the Yeonsan station were 0.048 ppm and 0.037 ppm, respectively. CO concentration was highest at two times of the day, and was proportional to the number of passengers commuting to and from work. The CO and $CO_2$ concentrations were highest in winter, but $NO_2$ concentration was highest in spring. CO and $CO_2$ concentrations were highest on Saturday and lowest on Sunday. The correlation of CO and $NO_2$ concentrations measured at the subway stations with those at the ambient air quality station were highest at the Seomyeon 1 and 2- waiting room and Jeonpodong. The correlation was lowest at the Yeonsan and Yeonsandong station. The number of days when $CO_2$ concentration exceeded 700 ppm over the last three years at the Seomyeon 1- platform was 174. The findings of this research are expected to deepen understanding of the fine particle characteristics at subway stations in Busan and be useful for developing a strategy for controlling urban indoor air quality.

지하철 승강장의 음원-수음점 거리에 따른 실내음향 평가지수 특성 (Characteristic of room acoustical parameters with source-receiver distance on platform in subway stations)

  • 김수홍;송은성;김정훈;이송미;류종관
    • 한국음향학회지
    • /
    • 제40권6호
    • /
    • pp.615-625
    • /
    • 2021
  • 본 연구에서는 지하철 승강장에 적합한 실내음향 설계기준 제시에 앞서, 현재의 지하철 승강장의 위치별 실내음향 특성을 파악하기 위해 2개의 지하철 역사 승강장에서 현장 측정을 실시하였다. 승강장의 길이방향에 따른 분석 결과, 음원에서 수음점이 멀어질수록 음압레벨은 감소(최대 차이: 약 14 dB), 잔향시간은 증가하는 경향(최대차이: 0.8 s ~ 1.5 s)이었고, C50과 D50은 감소하는 경향(최대 차이: 5.9 dB ~ 9.1 dB와 31.8 % ~ 37.6 %)인 것으로 나타났다. 공간감의 지표인 Interaural Cross-correlation Coefficient(IACC)는 음원과의 거리에 따른 명확한 경향성은 보이지 않았지만, 전체적으로 0.3이하의 낮은 값을 보였다. 이러한 결과를 살펴보았을 때 지하철 승강장은 일반적으로 강한 반사재로 마감 되었음에도 수음위치에 따라 직접음과 반사음의 다양한 조합이 형성되어 비균일한 음장특성을 갖는 것으로 판단된다. 이는 길이 대비 높이가 낮고 긴 평면형태를 갖는 지하철 승강장에서는 음원과 수음점의 거리에 따라 근접음장과 원음장의 실내음향특성이 뚜렷이 발현되고 있음을 나타난다. 따라서, 승강장의 모든 위치에서 명료한 음정보를 갖춘 실내음향설계를 위해서 승강장에서의 스피커와 수음점 위치별 특성에 기인한 세부 건축 및 전기음향설계가 필요하다.