• Title/Summary/Keyword: Subway environment

Search Result 372, Processing Time 0.026 seconds

Particulate Behavior in Subway Airspace

  • Sohn, Jong-Ryeul;Kim, Jo-Chun;Kim, Min-Young;Son, Youn-Suk;Sunwoo, Young
    • Asian Journal of Atmospheric Environment
    • /
    • v.2 no.1
    • /
    • pp.54-59
    • /
    • 2008
  • The most pivotal approach to improve subway indoor air quality (IAQ) is to examine the emission sources and particulate behavior. Therefore, the main objective of this study is to investigate the particulate behavior in the subway. In order to examine IAQ in the subway, a sampling and measurement campaign was carried out for 35 sites during the summer and winter seasons from May, 2005 to February, 2006. In case of 24 hour measurement, the mean concentrations ($PM_{10}$-24 hr) of platform and waiting room were $156.18{\pm}53.79{\mu}g/m^3$ and $111.00{\pm}53.31{\mu}g/ m^3$. Besides, as a result of 20 hour measurement, the mean concentrations ($PM_{10}$-20 hr) of platform and waiting room were $146.09{\pm}53.71{\mu}g/m^3$ and $99.08{\pm}42.77{\mu}g/m^3$, respectively. In general, $PM_{10}$-24 hr was higher than $PM_{10}$-20 hr, and both PM concentrations showed a high correlation coefficient (r=0.803). It was found that the $PM_{2.5}$ concentration ($l09.56{\pm}28.24{\mu}g/m^3$) in winter was higher than that ($83.66{\pm}57.82{\mu}g/m^3$) in summer.

Concentration and Properties of Particulate Matters (PM10 and PM2.5) in the Seoul Metropolitan (서울시 지하철 시스템 내의 입자상물질(PM10, PM2.5) 농도 특성)

  • Lee, Tae-Jung;Lim, Hyoji;Kim, Shin-Do;Park, Duck-Shin;Kim, Dong-Sool
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.31 no.2
    • /
    • pp.164-172
    • /
    • 2015
  • Seoul subway plays an important part for the public transportation service in Seoul metropolitan area. As the subway system is typically a closed environment, frequent air pollution problems occurred and passengers get malhealth impact. Especially particulate matters (PM) is well known as one of the major pollutants in subway environments. The purpose of this study was to compare the concentrations of $PM_{10}$ and $PM_{2.5}$ in the Seoul subway system and to provide fundamental data in order to management of subway system. $PM_{10}$ and $PM_{2.5}$ samples were collected in the M station platform and tunnel of Subway Line 4 in Seoul metropolitan and in an outdoor location close to it from Apr. 21, 2010~Oct. 27, 2013. The samples collected on teflon filters using $PM_{10}$ and $PM_{2.5}$ mini-volume portable samplers and PM sequential sampler. The PM contributions were $48.6{\mu}g/m^3$ (outdoor), $84.6{\mu}g/m^3$ (platform) and $204.8{\mu}g/m^3$ (tunnel) for $PM_{10}$, and $34.6{\mu}g/m^3$ (outdoor), $49.7{\mu}g/m^3$ (platform) and $83.1{\mu}g/m^3$ (tunnel) for $PM_{2.5}$. The $PM_{10}$ levels inside stations and outdoors are poorly correlated, indicating that $PM_{10}$ levels in the metro system are mainly influenced by internal sources. In this study, we compared PM concentrations before and after operation of ventilation and Electrostatic Precipitator (EP). Despite the increased PM concentration at outdoor, $PM_{10}$ concentration at platform and tunnel showed the 31.2% and 32.3% reduction efficiency after operation the reduction system. The overall results of this study suggest that the installation and operation of the ventilating system and EP should have served as one of the important components for maintaining the air quality in the subway system.

Characterization of Aerosols Collected at a Subway Station Platform Using Low-Z Particle Electron Probe X-ray Microanalysis (Low-Z particle EPMA 단일입자 분석법을 이용한 지하철 승강장에서 미세입자 특성 분석)

  • Hwang HeeJin;Oh MiJung;Kang Sun-ei;Kim HyeKyeong;Ro Chul-Un
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.6
    • /
    • pp.639-647
    • /
    • 2005
  • A single particle analytical technique, named low-Z particle electron probe X-ray microanalysis (EPMA), was applied to characterize samples collected at a subway station and ambient samples in Seoul. According to their chemical composition, many distinctive particle types were identified. For samples collected at the subway station platform, the major chemical species are carbon-rich, organic, aluminosilicates (AlSi), AlSi/C, AlSi/$CaCO_{3},\;CaCO_{3},\;SiO_{2},\;and\;Fe_{2}O_{3}$. For outdoor samples, carbon-rich, organic, AlSi, $CaCO_{3},\;SiO_{2},\;NaNO_{3},\;(Na,Mg)NO_{3},\;Na(CO_{3},NO_{3},SO_{4}),\;and\;(NH_{4})_2SO_4$, are abundantly encountered. Samples collected at the subway station show very high contents of $Fe_{2}O_{3}$, both in coarse and fine fractions, which come from brake block, subway train wheel, electric contact materials, etc. It is demonstrated that the single-particle characterization using this low-Z particle EPMA technique provided detailed information on various types of chemical species in indoor and outdoor samples.

Thermal and Hygroscopic Properties of Indoor Particulate Matter Collected on an Underground Subway Platform

  • Ma, Chang-Jin;Lee, Kyoung-Bin;Zhang, Daizhou;Yamamoto, Mariko;Kim, Shin-Do
    • Asian Journal of Atmospheric Environment
    • /
    • v.9 no.3
    • /
    • pp.228-235
    • /
    • 2015
  • In order to clarify the thermal and hygroscopic properties of indoor particulate matter (PM) in a semiclosed subway space, which is critically important for understanding of the distinctive particle formation processes as well as the assessment of their health effects, the size-resolved PMs (i.e., $PM_{2.5}$ and $PM_{10-2.5}$) were intensively collected on the platform of Miasageori station on the Seoul Subway Line-4. The elemental concentrations in soluble and insoluble fractions were determined by PIXE from the bulkily pretreated $PM_{2.5}$. The thermal and hygroscopic characteristics of individual particles were investigated via a combination of the unique pretreatment techniques (i.e., the high-temperature rapid thermal process and the water dialysis) and SEM-EDX analysis. Iron and calcium were unequaled in insoluble and soluble $PM_{2.5}$ fractions, respectively, with overwhelming concentration. The SEM-EDX's elemental net-counts for the pre- and post-pyrolyzed PMs newly suggest that magnesium and several elements (i.e., silica, aluminum, and calcium) may be readily involved in the newly generated subway fine PM by a high-temperature thermal processing when trains are breaking and starting. Through the water dialysis technique, it turned out that calcium has meaningful amount of water soluble fraction. Furthermore, the concentrations of the counter-ions associated with the calcium in subway $PM_{10-2.5}$ were theoretically estimated.

A Study on Improvement of Means of Realization of Train Destination Equipment System (인공자연광을 이용한 지하역사 환경개선 방안 연구)

  • Yeo, Yong-Joo;Yoon, In-Young
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.352-357
    • /
    • 2008
  • Using the artificial sun, namely the BIOSUN, we can control the sun light according to the latitude and longitude and for the seasonal changes and apply that to subway stations. By doing this, we can expect three effects, a. allowing the plants to grow inside the stations which will in turn contribute to improving air purity, controlling humidity, and reducing dust for pleasant environment, b. pleasant environment will foster positive emotional responses of the passengers and that would increase the satisfaction, and c. fostering good service for the citizenry and establishing an environmental friendly image of the Seoul Metro Subway System. The purpose of this thesis paper is to contemplate on the uses of the artificial sun powered by the microprocessor of a Light Emitting Diode (LED) in controlling the light and how the light can be utilized in facilitating photosynthesis that would allow plants to grow inside subway stations.

  • PDF

Prediction of Trajectories of Particles Generated Underneath a Subway Train Running in An Underground Tunnel (지하터널에서 주행하는 전동차의 하부에서 발생한 입자의 이동경로 예측)

  • Lee, Kyung-Ran;Kim, Won-Geun;Yook, Se-Jin;Woo, Sang-Hee;Kim, Jong Bum;Bae, Gwi-Nam;Park, Hyung-Koo;Yoon, HwaHyeon
    • Particle and aerosol research
    • /
    • v.11 no.1
    • /
    • pp.21-28
    • /
    • 2015
  • In this study, the flow around a subway train running in an underground tunnel was numerically estimated. For the validation of the numerical results, the airflow velocity at a point underneath a subway train was measured using an ultrasonic anemometer. Then, the trajectories of particles generated at the contact points between the wheels and rails were numerically predicted. By considering the airflow velocity and particle trajectories, the space underneath the T-Car (trailer car) was expected to be appropriate for the room for the installation of a dust-removal system.

Development of Tunnel-Environment Monitoring System and Its Installation I -Monitoring System and Measurement in Subway Tunnel- (터널 환경측정 시스템 개발 및 측정 I -개발 시스템 및 지하철터널 측정-)

  • Park, Won-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.12
    • /
    • pp.8608-8615
    • /
    • 2015
  • We developed a system that can collect and transmit real-time environmental data such as temperature, humidity, wind direction, and wind speed, and equipment performing aging tests on fire detectors. This system was installed in three representative sites of railway tunnels in South Korea such as Gumjung, Solan, Seoul Subway Line 4 tunnels. The systems showed a stable performance and collected environmental data for over a year. We analyzed environmental data collected by two of our developed systems installed in the running tunnels of Gwacheon Line of Seoul Subway Line 4. The developed system was capable of safely analyzing tunnel environments for 24 h straight using a wireless communication network, and has potential for use in a variety of fields other than tunnels.

A Study on the Improvement Plan of Bench Design at a Subway Platform (지하철 승강장 벤치 디자인 유형의 개선방안에 관한 연구)

  • Yang, Hae Won;Kim, Joon Ji;Lee, Joo Hyun;Lee, Hyun Soo
    • KIEAE Journal
    • /
    • v.8 no.2
    • /
    • pp.71-78
    • /
    • 2008
  • Subway is a major transportation in the city that is allied to the daily life of people. As a public space, subway station must satisfy the citizens with convenience, safety and esthetic factors. The bench which is one of the major street furniture on the subway platform has a lot of physical contact. Therefore the design of benches must be considered in the aspects of not only aesthetic design but also ergonomic design. The goal of this study is to find out the current conditions and problems of benches and at the same time suggest how to arrange, design, and manage them at the proper manners at subway platform. The result of the study is as follows. First, the problems of design are that the benches at a same platform have various design, the saturation of color is too high, and the design is unfashionable. The second, at the management part there is no such a total management system and specialist for the street furniture section and lack of rational management regulations. The third, results of a new survey suggest that citizens think negatively about present bench's conditions such as design and administration.

Indoor and Outdoor $NO_2$ Concentration at Subway Station and Personal $NO_2$ Exposure of Subway Station Workers (지하철역사의 이산화질소 농도와 역무원의 이산화질소 개인폭로량)

  • 손부순;장봉기;박종안;김윤신
    • Journal of environmental and Sanitary engineering
    • /
    • v.15 no.4
    • /
    • pp.134-141
    • /
    • 2000
  • The person' spending time in underground s[aces within indoor environment show a tendency to increase every year, but in Korea, levels and sources of pollutant in underground spaces have not been well-characterized. Therefore, as part or a larger indoor environmental study, conducted at subway station in Seoul, nitrogen dioxide was measured using passive samplers in 16 subway stations, 2 tunnels and 70 workers of subway station. The mean concentrations of nitrogen dioxide in subway stations were $27.87{\pm}7.15$ ppb at station office, $35.76{\pm}8.35$ ppb at platform, $52.60{\pm}13.04$ ppb at outdoor, respectively, and the Indoor/Outdoor ratio were 0.49~0.93. The mean concentrations of nitrogen dioxide in tunnels were $44.91{\pm}4.67$ ppb in Chunggye-Nowon tunnel with a single track, $42.55{\pm}3.33$ ppb in Mokkol-Taenung tunnel with double track, respectively, and as a result of t-test, a single track levels were higher than double track levels(p<0.05). The mean personal exposure of the subject of station workers was $29.40{\pm}9.75$ ppb.

  • PDF

A Study on Environmental Applications of Subway Line Color as Place Indicating Cues - Focused on Subway Transfer Stations of Seoul and Hong Kong - (장소지시단서로서 지하철 노선색 활용에 관한 연구 - 서울과 홍콩의 지하철환승역 사례를 중심으로 -)

  • Park, Hey-Kyung
    • Korean Institute of Interior Design Journal
    • /
    • v.18 no.6
    • /
    • pp.229-238
    • /
    • 2009
  • Currently, subway is becoming a major part of transportation and living environment in large cities such as Seoul or Hong Kong. As the numbers of subway lines and stations increase, visual cues indicating places are needed for users with various destinations, and environmental colors as well as line colors can be expected as effective informations for easy wayfinding. The purpose of this study is to understand the current color applications in terms of creating regional differentiation and informing subway lines in the transfer stations of Seoul and Hong Kong, by field investigation. The investigation has been proceed on 24 transfer stations from February to April, 2009 by taking photos and measuring environmental colors using Minolta spectrophotometer CM-2600d. As a result, regional differentiation in color application appeared generally low in both Seoul and Hong Kong but various 'hues' differing each station are used in Hong Kong, compared to limited use of 'hues' in Seoul, In terms of 'value', the rate of Seoul appeared lightly higher than that of Hong Kong, and the use of medium high rate of 'saturation' of main and secondary colors are shown as a remarkable character of Hong Kong.