• 제목/요약/키워드: Subway Tunnel

검색결과 385건 처리시간 0.025초

터널 시공 중 보강공법 선정용 퍼지 전문가 시스템 개발 (Development of the Fuzzy Expert System for the Reinforcement of the Tunnel Construction)

  • 김창용;박치현;배규진;홍성완;오명렬
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.101-108
    • /
    • 2000
  • In this study, an expert system was developed to predict the safety of tunnel and choose proper tunnel reinforcement system using fuzzy quantification theory and fuzzy inference rule based on tunnel information database. The expert system developed in this study have two main parts named pre-module and post-module. Pre-module decides tunnel information imput items based on the tunnel face mapping information which can be easily obtained in-situ site. Then, using fuzzy quantification theory II, fuzzy membership function is composed and tunnel safety level is inferred through this membership function. The comparison result between the predicted reinforcement system level and measured ones was very similar. In-situ data were obtained in three tunnel sites including subway tunnel under Han river, This system will be very helpful to make the most of in-situ data and suggest proper applicability of tunnel reinforcement system developing more resonable tunnel support method from dependance of some experienced experts for the absent of guide.

  • PDF

지하철 차량 선로 정차 시 피난 행동에 관한 실험 (Experiments of Egress Behavior When Subway Car Stops on Railroad)

  • 김종훈;김운형;이덕희;정우성
    • 한국화재소방학회논문지
    • /
    • 제26권3호
    • /
    • pp.1-7
    • /
    • 2012
  • 지하철 차량이 선로에 정차하는 경우 승객들은 지하철 바닥과 선로 바닥의 1.2 m 높이를 내려가야 하는 상황에 처하게 된다. 이러한 상황에 대한 데이터의 확보는 선로와 터널에 정차된 지하철 차량의 피난해석을 수행하는 데 필요한 자료가 된다. 실험결과 20대 및 그 이하 연령층은 매우 신속히 이 높이를 내려가 하차할 것으로 나타났다. 그러나 고령자들에게는 보조자의 도움 없이는 쉽게 내려갈 수 없는 높이로 실제 실험에서도 넘어짐과 부상이 발생하였다. 또한 차량 문앞에 선로 벽이 있고, 타 피난인들이 지나가고 있어 합류를 해야하는 경우에는 20대 그룹도 낮은 유동율을 보여주었으며, 실제 화재 시 벽이 있는 선로나 터널의 경우 차량에서 외부로의 피난시간을 증가 시킬 것으로 나타났다.

지하철 모사터널에서 에어커튼을 이용한 환기구의 배기효율 및 미세입자 농도 변화 연구 (The Study on Changes of Exhaust Efficiency and Fine Particle Concentration at a Ventilation Opening by a Air Curtain Flow in a Subway Model Tunnel)

  • 한방우;김학준;김용진;정상현;김용민;김종률
    • 한국대기환경학회지
    • /
    • 제27권5호
    • /
    • pp.614-622
    • /
    • 2011
  • In this study, a new tunnel ventilation method with a high velocity air curtain flow has been investigated for improving the ventilation exhaust efficiency and removing air pollutants in subway tunnels. At upper or lower position right downstream of a main duct connected with a ventilation opening, air curtain flows were suppled into the main duct where the air flow velocity was in the range of 2~6 m/s. Exhaust efficiency was monitored for both cases with and without air curtain flow for different air velocities, locations and injection angles of the air curtain. Particulate matter concentrations (PM10, PM2.5 and PM1.0) were also checked at both the main duct and ventilation opening before and after supplying air curtain flows. Lower air velocity of the main duct flow, higher air velocity of the air curtain led to higher exhaust efficiency and the air curtain condition of 30..inclined injection toward the main flow showed the maximum exhaust efficiency. The exhaust efficiency of about 24% without the air curtain could be improved to about 34% after using the air curtain flow. PM concentration decreased at the main duct and increased at the ventilation opening after using the air curtain flow. Therefore, the suggested method to use air curtain flows in tunnels will be probably one of the promising tools to reduce air pollutants in subway tunnels.

지하철 터널 환경에서 2.65GHz 대역신호의 경로손실 특성 (Path Loss Characteristics in Subway Tunnel at 2.65GHz)

  • 조한신;김도윤;육종관
    • 한국통신학회논문지
    • /
    • 제31권10A호
    • /
    • pp.1014-1019
    • /
    • 2006
  • 본 논문에서는 측정을 통해 지하철 터널환경에서 위성 DMB 상용주파수 대역인 2.65 GHz 신호의 전파특성을 분석하였다. 다양한 터널 구조에 따른 경로손실 특성을 분석하기 위해 직선터널과 곡선터널 및 직선, 곡선구간이 함께 존재하는 혼합터널 내에서 수신 전력을 측정하였다. 측정을 수행한 모든 터널의 가시영역 경로손실 지수-는 $1.31{\sim}2.19$로서, 실외 셀룰라 환경의 경로손실 지수$(3{\sim}4)$와 비교했을 때 터널의 가시영역은 신호의 감쇄가 매우 적은 채널환경임을 알 수 있었다. 직선터널과 곡률반경이 500m, 200m인 두 곡선터널 비가시 영역의 경로 손실 지수는 각각 1.94, 2.92, 4.34로서 곡률반경이 작을수록 경로손실이 급격하게 발생하는 현상을 확인할 수 있었다. 한편 혼합터널의 곡선구간에 대한 경로손실 지수는 5.88로서 동일한 곡률반경을 갖는 곡선터널의 경로손실 지수 4.34 보다 큰 값을 보였다. 이를 통해 터널 환경에서의 경로손실 지수는 곡률 반경뿐만 아니라 송신기와 비가시영역 사이에 존재하는 가시영역의 거리에도 영향을 받는다는 사실을 알 수 있었다.

계측에 의한 터널 라이닝의 안전성 분석 (A Safety Analysis of Tunnel Lining for Monitoring)

  • 우종태;이송
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제6권3호
    • /
    • pp.103-110
    • /
    • 2002
  • Maintenance monitoring of the tunnel which offers continuous data during and after tunneling has been applying to tunnels in order to meet the maintenance of tunnel and to confirm continuous security of the tunnel after tunneling. But, the maintenance monitoring of tunnel results for long period is not easy to find, and moreover, the rational analysis method on tunnel monitoring has not been established yet. In this study, the relationships between displacement and stress of the tunnel concrete lining using various analysis methods are compared with maintenance monitoring. The tunnel behavior were measured in the subway tunnel passing comparative soft the weathering and analyzed both security and mechanical characteristics of the tunnel concrete lining. Also, analyzed relationship between residual water pressure applied on tunnel design and one obtained by monitoring.

복합지반 EPB TBM 커터교체를 위한 그라우팅 수행 사례 (Pre-grouting for CHI of EPB shield TBM in difficult grounds: a case study of Daegok-Sosa railway tunnel)

  • 강성욱;장재훈;이재원;김대영;신영진
    • 한국터널지하공간학회 논문집
    • /
    • 제23권5호
    • /
    • pp.281-302
    • /
    • 2021
  • 철도망 구축이 확대되는 추세 속에 도심지나 한강을 통과하기 위해 TBM 굴착공법 적용사례가 증가하고 있다. 특히, 도심지나 한강하저를 통과하는 경우 불량한 지반 및 지하수조건을 조우하게 되며 안정적인 굴진 및 커터교체(Cutter Head Intervention, CHI)를 위해서 그라우팅을 적용하고 있다. 본 논문에서는 TBM 굴착공법을 적용한 철도 터널 시공 시 적용한 그라우팅에 대하여 소개하고자 한다. 특히, CHI를 위해 그라우팅을 수행한 사례에 대한 소개나 분석이 많지 않은 것으로 판단하여 CHI를 위한 그라우팅 범위산정, 수행결과, 고찰 및 제언(Lessons Learned)을 기술하고자 한다. 그라우팅은 막장안정성을 확보하는 목적이 있으며, 작업위치에 따라 지상(수직)그라우팅과 TBM 장비 내에서 수행하는 갱내 그라우팅으로 나눌 수 있다. 갱내그라우팅을 수행한 결과 공기 및 보강효과 측면에서 지상(수직) 그라우팅에 비해 비효율적이라고 판단되어 지상그라우팅으로 계획을 변경하였다. 한강하저 구간의 경우 슬러지 발생으로 인한 환경오염, 주입재 유실 등이 우려되어 고압분사그라우팅을 적용할 수 없었으며 대안으로 수중불분리 주입재를 적용한 저압그라우팅을 적용하였다. 육상구간은 지상 작업부지를 확보할 수 있어 고압분사그라우팅을 적용하였다. 실제 그라우팅을 수행한 결과를 소개함으로써 향후 쉴드 TBM을 적용한 터널 시공 중 CHI 시 지반조건에 따른 적합한 그라우팅 공법 및 방법을 결정하는데 기초자료로 활용될 수 있을 것으로 기대된다.

지하철 차량과 승강장의 연계공간에 대한 피난모델링 적용비교 (Comparison of Egress Modeling for the Connected Space from Subway Car to Platform)

  • 김종훈;서동훈;어득강;김운형;이덕희;정우성
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.870-873
    • /
    • 2011
  • 철도 차량에서의 화재 발생 시 피난에서 차량에서 승강장이나 터널 같은 외부 환경은 매우 중요하다. 많은 인원이 탑승하게 되는 지하철과 그 승강장의 영향을 알아보기 위해, SIMULEX, PATHFINDER, STEPS를 시나리오에 적용 비교해 보았다. 대상차량은 서울에서 운행되는 차량을 기준으로 하였으며, 대상 승강장은 [도시철도 정거장 및 환승 편의시설 보완설계지침]을 기준으로 제작한 모델을 적용하였다.

  • PDF

지하철 운행에 의한 인접건물의 진동영향 평가 연구 (Reduction and Evaluation of Subway Induced Vibration Effects on Surrounding Buildings)

  • 박지훈;민경원;이루지;최석주;염성곤
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.738-742
    • /
    • 2005
  • Ground vibration at Gil-dong in Seoul induced by the 5th ling of Seoul Subway is predicted using various prediction methods and compared with measured vibration. Also, several issues on the improvement of prediction methods are discussed. Furthermore, as an alternative vibration source, measured vibration acceleration level(VAL) on the tunnel wall of the Bundang line of Seoul Subway is applied to the prediction of the VAL at the location mentioned previously. Then requirements accompanied to the suggestion of the new vibration source appropriate to the condition of Seoul Subway.

  • PDF

도시철도 객실 공기정화장치(SCAP)의 운행차량 효율평가 (Efficiency Evaluation of Operating Railroad with Subway Cabin Air Purifier)

  • 권순박;박덕신;조영민;김종범;조관현;남궁석;이주열;김태성
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.1303-1308
    • /
    • 2011
  • In the modern society various types of transportation mode are utilized, among them the subway system is the one of the main transportation mode which more than 7.21 million people ride a day. Because of interests on the indoor air quality (IAQ) of underground public facilities, concerns on IAQ of subway system by many people are increasing. There are several approach to improve IAQ of subway station, such as installing platform screen door (PSD), frequent tunnel washing-out, and etc, however there has not been any attempt to improve IAQ of subway cabin inside. Most technologies for removing airborne particulate matters are known to be difficult to adopt on the subway cabin since the problem of maintenance cost. Therefore, the ultimate object of this study is a practical development of cabin air cleaning system which can reduce the concentration of airborne particles and harmful gases at the same time. The subway cabin air purifier (SCAP) was developed for removing particulate matters and gases pollutants inside a cabin. The whole system was designed and the roll-filter device was manufactured based on numerical prediction results. It is expected that SCAP could reduce indoor air pollutants in the subway cabin practically and it can be applied to other part of transportation vehicles.

  • PDF