• Title/Summary/Keyword: Substrate Concrete

Search Result 120, Processing Time 0.024 seconds

Proposal of Concrete Pull Off Bond Strength Measurement Method for Bridge Deck Overlay (교면 덧씌우기 콘크리트의 인발부착강도(引拔附着强度) 시험법(試驗法) 제안(提案))

  • Kim, Seong-Hwan;Kim, Dong-Ho;Kim, Hyun-Oh;Lee, Bong-Hak
    • Journal of Industrial Technology
    • /
    • v.23 no.A
    • /
    • pp.149-156
    • /
    • 2003
  • The development and maintenance of a sound bond are essential requirements of concrete repair and replacement. The bond property of a overlay to its substrate concrete during the lifetime is one of the most important performance requirements which should be quantified. A standard or a verified bond strength measurement method is required at field for screening, selecting materials and quality control for overlay or repair materials, but no test method has been adopted as a standard. In this study, a concrete pull off bond strength measurement method for field application is proposed and evaluated. This study compares the splitting tensile test, slant shear test, nipple pipe direct tensile test, flexural adhesion test, briquette tensile test, jumbo nail pull-out test and core pull-off test with their test procedures. From these comparison and investigation, core pull-off test is selected as a main topic of this study because of it's suitability for in situ testing, simplicities in field application and clearness at interface boundary condition. Thus, the proposed core pull off test is evaluated to be the most appropriate method for field application in a simple manner. The fracture surface and fracture mode could be easily determined by visual observation of failure surface of the field specimen. The core pull off test was found to be sensitive to surface condition and latex contents at latex modified concrete.

  • PDF

Development of Green Retaining-wall System with Native Evergreen Plants Corresponding to the Southern Region - A Case Study of Tongyeong City in Gyeongsangnam-do - (남부지역의 특성을 고려한 상록벽면녹화 공법 개발 -경남 통영시를 사례로-)

  • Kang Ho-Chul;Kim Kwang-Ho;Huh Keun-Young
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.33 no.2 s.109
    • /
    • pp.32-47
    • /
    • 2005
  • This study was carried out to investigate and propose a green-wall system with evergreen plants for urban greening of Tongyeong City. To achieve these goals, the requirements and possibilities for wall greening were investigated and evaluated considering the location, topography, and climate of Tongyeong City. Existing walls were analyzed and then a suitable green wall system is proposed. Tongyeong City and its 151 islands covers the central and the southern parts of the Goseong peninsula. Most of the land is covered with hills and mountains; $43.9\%$ of the land area has a slope greater than $15\%$ and most hills and mountains near the urban area have a slope of more than $30\%$. As a result of the topographical properties, concrete retaining walls can often be seen along the streets in urbanized areas. These retaining walls are not only unattractive, but they also create environmental problems, and thus should be replaced with native evergreen plants. Options for replacing the retaining walls include evergreen vine-plants such as Hedaa spp. and Euonymus radicans, but native evergreen shrubs such as Pittosporum tobira, Nandina domestica, Raphiolepis umbellata, Ilex cornuta, flex crenata, Fatsia japonic, and Aucuba japonica may be a more attractive option. Current wall conditions are unsuitable for planting vines, therefore, a reservoir-drainage-type plant box filled with a light artificial substrate is required for greening these concrete retaining walls. These might be irrigated in the dry season and fertilized annually by an appropriate system. These plant boxes could be attached along the entire walls. An experiment investigating effects of substrates and bark-chip mulching on the growth of Hedera spp. showed that the mixture of cerasoil and field soil(v/v, 4:6) was superior to field soil alone and to the mixture of perlite small grain, large grain, and field soil(v/v/v, 2:2:6). Bark-chip mulching tended to increase the growth of Hedera spp..

Experimental investigation on optimal shear strengthening of RC beams using NSM GFRP bars

  • Ramezanpour, M.;Morshed, R.;Eslami, A.
    • Structural Engineering and Mechanics
    • /
    • v.67 no.1
    • /
    • pp.45-52
    • /
    • 2018
  • Several techniques have been developed for shear strengthening of reinforced concrete (RC) members by using fiber reinforced polymer (FRP) composites. However, debonding of FRP retrofits from concrete substrate still deemed as a challenging concern in their application which needs to be scrutinized in details. As a result, this paper reports on the results of an experimental investigation on shear strengthening of RC beams using near surface mounted (NSM) FRP reinforcing bars. The main objective of the experimentation was increasing the efficiency of shear retrofits by precluding/postponing the premature debonding failure. The experimental program was comprised of six shear deficient RC beams. The test parameters include the FRP rebar spacing, inclination angle, and groove shape. Also, an innovative modification was introduced to the conventional NSM technique and its efficiency was evaluated by experimental observation and measurement. The results testified the efficiency of glass FRP (GFRP) rebars in increasing the shear strength of the test specimens retrofitted using conventional NSM technique. However, debonding of FRP bars impeded exploiting all retrofitting advantages and induced a premature shear failure. On the contrary, application of the proposed modified NSM (MNSM) technique was not only capable of preventing the premature debonding of FRP bars, but also could replace the failure mode of specimen from the brittle shear to a ductile flexural failure which is more desirable.

A Study on the Analysis of 3 Dimensional Substrate Behaviour of Complex Environmental Deterioration and the Analysis of Results (복합열화분석용 3차원 거동대응성 시험방법 및 결과분석)

  • Song, Je-Young;Oh, Kyu-hwan;Choi, Eun-Kyu;Lee, Jung-Hun;Kim, Byoungil;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.77-78
    • /
    • 2017
  • Although many waterproofing materials and techniques have been developed and applied, there is still a leakage in concrete structures. The main reason for the failure of waterproofing is due to the lack of consideration of the environmental conditions and the inconsistent performance requirement of the waterproofing materials in response to the complexity of the environmental conditions., and materials that are unsuitable to the environment are still being selected for usage due to their low price. Moreover, there is no valid test assessment for waterproofing materials to be used prior to actual application in the construction site. The development of a testing method and apparatus that can evaluate the composite waterproofing method is proposed in this paper and an interpretation method that can analyze the results of the evaluation.

  • PDF

Development of Repair System for Drain Pipe to Enhance Safety (하수관거 안전성 향상을 위한 보수 시스템 개발)

  • Chung, Jee-Seung;Kang, Weon-Dae
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.6
    • /
    • pp.45-53
    • /
    • 2011
  • This study was performed to develop repair and reinforcing materials in sewage drain pipe by using 40% of CAC(Calcium Aluminate Cement) and 4% of Polymer Powder. Regarding reinforcing materials to enhance load-bearing capacity, polyester textile and wire mesh were adopted and then they were evaluated by the measurement of deflection and Stress-strain Relationship. Two types of drain pipe made by concrete and PE were considered as plain specimens and then loading test were performed after repaired by CAC mortar impregnated reinforcing materials. As the test results of the load-bearing test on both drain pipe, there was higher load-bearing capacity on the specimen adopted wire mesh but debonding of repair mortar was found due to stiffness of wire mesh. By the way, repair system using CAC mortar impregnated polyster textile without wire mesh showed satisfactory results including bonding and load-bearing capacity regardless substrate, so this repair system using by mixture of CAC mortar and polyster textile is suggested as the reasonable repairing method within this experimental scope.

Preliminary Investigation into the Use of Methyl Methacrylate(MMA)-Based Materials for Road Repair (메틸 메타크릴레이트 기반 도로 보수재 개발을 위한 기초 연구)

  • Ji, Sung-Jun;Pyeon, Su-Jeong;Choi, Byung-Cheol;Kim, Jae-Hwan;Kim, Do-Su;Nam, Jeong-Soo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.24 no.1
    • /
    • pp.35-42
    • /
    • 2024
  • This research explores the potential of methyl methacrylate(MMA) as a material for road repair applications. It specifically examines two MMA formulations, referred to as type A and type B, in relation to their performance on concrete substrates. The evaluation criteria included drying time, tensile bond strength, and resistance to alkali. The condition of the substrate surface was varied across three curing environments: constant temperature and humidity(R), immersion in water(W), and immersion in water with chloride ions(N). The findings indicate that type B MMA exhibits a quicker drying time and superior resistance to alkali compared to type A. While type A demonstrated greater tensile bond strength, it failed to maintain adhesion with the concrete base. Based on the parameters tested in this study, type B MMA emerges as the more favorable option for road repair contexts. Nonetheless, the study underscores the necessity for additional testing on asphalt substrates to fully assess the material's durability and applicability for long-term road maintenance.

Study on the injecting technology of waterproofing layer for water leakage repair of roof (건축물 옥상방수층의 누수보수를 위한 방수층재형성 주입기술에 관한 연구)

  • 배기선;조일규;장혁수;곽규성
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2002.11a
    • /
    • pp.23-27
    • /
    • 2002
  • Waterproofing is one of the important factor to improve performance of building elements. But existing repair system for waterproofing have many problems like a damage of waterproof layer due to movement of concrete substrate, blistering effect and moisture condition. So waterproofing layer can not play an important part to improve waterproofing function and performance of building. Therefore, new waterproofing system to solve these problems of existing waterproofing system is developed. In this paper, new waterproofing system in water-leakage repair for remodeling is introduced

  • PDF

A Study on the field application analysis for high adhesive spray type of degenerated and rubberized asphalt membrane material (스프레이식 고점착 변성 고무 아스팔트 도막 방수재의 재료 및 공법에 관한 실험적 연구)

  • Oh, Sang-Keun;Song, Je-Young;Kim, Jin-Seong;Lee, Nam-Kyoo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.11a
    • /
    • pp.61-65
    • /
    • 2006
  • Urethane, epoxy, acrylic have common property to adhere on the concrete dried surface in the waterproofing materials at present. In the wet condition, however, the materials such as urethane, epoxy, acrylic need a long hardening time and it become a reason of water leakage as the materials breaking down. it is one of the problem to adhere to the substrate. Therefore, in this thesis, I focused to assure the structural safety and durability and quality for waterproofing and safe of construction cost by cut down the cost of labor and reduce the term of works as searching the application of field condition for hish adhesive spray type of degenerated and rubberized asphalt membrane material.

  • PDF

A Study on the Analysis of 3 Dimensional Substrate Behaviour of Complex Environmental Deterioration and the Analysis of Results (복합열화분석용 3차원 거동대응성 시험을 통한 결과분석)

  • Song, Je-Young;Seo, Hyun-Jae;Kim, Bum-Soo;Choi, Eun-Kyu;Lee, Jung-Hun;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.219-220
    • /
    • 2017
  • Current domestic waterproofing market in Korea mainly uses single-ply waterproofing materials comprised of coatings or waterproof sheets and two or more-ply composite waterproofing methods. In order to evaluate these types of composite waterproofing systems, a new test equipment and method that incorporates various deterioration conditions (joint displacement, chemical exposure, water pressure etc) was developed. In a comparison testing, the results showed that flexible type materials have higher response performance towards joint displacement than the hardened material. Furthermore, the importance of securing the stability of the waterproofing method in the vulnerable over-lap joint areas of waterproofing sheets is emphasized.

  • PDF

Dynamic analysis of the micropipes reinforced via the carbon dioxide adsorption mechanism based on the mathematical simulation

  • Liu, Yunye
    • Computers and Concrete
    • /
    • v.30 no.3
    • /
    • pp.185-196
    • /
    • 2022
  • In this paper, the dynamic characteristics of a composite cylindrical beam made of a mechanism of carbon dioxide absorption coated on the tube core are investigated based on the classical beam theory coupled with the modified couple stress theory. The composite tube structures are assumed to be uniform along the tube length, and the energy method regarding the Hamilton principle is utilized for generating the governing equations. A powerful numerical solution, the generalized differential quadrature method (GDQM), is employed to solve the differential equations. The carbon dioxide trapping mechanism is a composite consisting of a polyacrylonitrile substrate and a cross-link polydimethylsiloxane gutter layer. Methacrylate, poly (ethylene glycol), methyl ether methacrylate, and three pedant methacrylates are all taken into account as potential mechanisms for capturing carbon dioxide. The application of the present study is helpful in the design and production of microelectromechanical systems (MEMS) and the different valuable parameters, such as the length-scale parameter, rate of section change, aspect ratio, etc., are presented in detail.