• Title/Summary/Keyword: Substation Automation

Search Result 136, Processing Time 0.033 seconds

Application study of substation automation protocol (IEC 61850) to digital relay (디지털 계전기에 변전소 자동화 프로토콜 (IEC 61850) 적용에 관한 연구)

  • Rim, Seong-Jeong;Choe, Hang-Seob;Min, Byoung-Woon;Park, Dong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.489-491
    • /
    • 2005
  • This paper presents the application study of substation automation protocol, IEC 61850 to digital relay (HiMAP). Especially, it implements the data modeling, ACSI definition, GOOSE, MSVCB and data service required in the existing digital relay. To verify the system performance, we develop the process emulator and HiMAP emulator, and describe the results.

  • PDF

Fault Tolerant of IED in IEC61850 based Substation Automation System (IEC 61850기반 변전소 자동화 시스템에서 IED의 결함 극복 방법)

  • Lee, Dong-Wook;Jin, Yong-Woo;Lee, Duck-Su;Lim, Seong-Il;Lee, Seung-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.152-154
    • /
    • 2005
  • This paper proposes new methods which are used for trouble detecting and tolerance of IED in IEC61850 based Substation Automation System. There are three point devices for construction of this system: Trouble Detection IED, Backup IED and Engineering Unit. Trouble Detection IED tests trouble of Bay IED and sends the result to Engineering Unit. And then Engineering Unit is able to control the system. When fault occurs in Bay IED, Backup IED will be substitute the troubled Bay IED. If this proposed scheme can be used in this system, the reliability of the Power System would be greatly improved.

  • PDF

Strategy coped with the Power Utility on IEC 61850 based Substation Automation (IEC 61850기반 변전자동화 적용에 대한 전력회사 대응 전략)

  • Kim, B.H.;Jang, B.T.;Lee, N.H.;Jeong, K.W.;You, H.Y.;Yo, K.T.
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.375-378
    • /
    • 2008
  • As a result of the research project of IEC 61830 based substation automation system related products have launched on the domestic market. Accordingly, power utility such as KEPCO need to make strategy to operate and apply this new system optimally to power system Providing reliability analysis of domestic trial IED products, commercialization, training of engineering staffs and standardization will result in improving reliability and making rower system stable.

  • PDF

154kV Main TR. Bay IED Based On IEC 61850 (IEC 61850 기반의 154kV M.Tr Bay IED 적용 사례)

  • Roh, Jae-Keun;Oh, Jae-Hoon;Yang, Hang-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.11
    • /
    • pp.2028-2034
    • /
    • 2011
  • Substation Automation System (SAS) based on IEC 61850 is becoming more and more reality in applying power systems. As well, the development of various engineering tools and the convergence with diagnostic systems are underway. To reflect recent advancements in SAS technology, the Korea Electric Power Corporation initiated a 154kV SAS pilot project and a smart power grid business in 2010. In this paper, the authors will summarize the overview and the lessons learned in applying the IEC 61850-based 154kV Main transformer bay IED solutions to these two project.

The Functions and Characteristics of Distribution Automation System Components (국산 배전자동화시스템 구성설비의 보유기능 및 특성)

  • Ha, B.N.;Park, S.M.;Jang, J.T.;Choi, T.I.;Kim, H.Y.;Oh, S.G.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.899-901
    • /
    • 1996
  • KODAS is made up of the Central Control System(CCS) as four Vax workstations linked up with LAN networks, six Substation Communication Control Units(SCCU) installed in substation to transfer data, 125 Feeder Remote Units(FRU) located at the lower position of automated switch to provide the information of Fault Indicator(FI) and three kinds of automated switches to have remote control functions such as SF6 gas feeder automation switch, recloser and gas insulated pad mountes switchgear for under ground line. This paper explains the functions and characteristics in detail about each devices mentioned above.

  • PDF

A web-based power quality monitoring system in the Substation Automation System (변전소 자동화 환경에서 웹 기반 전기품질 감시 시스템)

  • Park D. H.;Lim S. J.;Shin J. H.;Lim S. I.;Lee S. J.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.378-380
    • /
    • 2004
  • Along with the increase of the importance of power quality, many various systems are dedicated in the analysis of power quality nowadays. But there still exists the same problems for realizing such kind of analysis systems well. One is the customization of the power quality measure devices; The other is an economic problem. This paper presents the usefulness and the advantage of the ICD (Intelligent Electronic Device) as the measure device of power quality And this paper detailedly describes the development procedure of web-based power quality monitoring system through ActiveX controls. Now this power quality monitoring system is already applied to the substation automation system.

  • PDF

Research on Protocol Conversion Gateway based on IEEE1815.1 (IEEE 1815.1 기반 이기종 프로토콜 변환 게이트웨이 기술 연구)

  • Lee, Seokjun;Kwon, Sungmoon;Shon, Taeshik;Park, Sungwan
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.26 no.5
    • /
    • pp.1201-1209
    • /
    • 2016
  • While the legacy electric grid evolving into the smart grid, various communication standards have been used for interoperability between many components. In this situation, the needs emerged for protocol conversion and mapping method for connecting the outside components to the operation center. In this paper, according to the surge of IEC 61850-based substation automation, we studied the protocol conversion gateway for linking legacy DNP3-based control center and IEC 61850-based substation automation. This paper is based on the IEEE 1815.1 standard for the protocol mapping. We suggested the direction of development the gateway and developed prototype for evaluate the proposed gateway. Also, we bring up a security problem and give a solution.

On-line coordination control of OLTC and Switched Shunt for enhancement of stability using local data in substation (변전소내 지역정보를 이용하여 안정도 향상을 위한 실시간 OLTC 및 커패시터 협조제어 알고리즘)

  • Kang, Sang-Gyun
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.17 no.7
    • /
    • pp.119-125
    • /
    • 2012
  • This paper suggest the on-line coordination control between on-load tap changers and Switched Shunts for ensuring the voltage stability using local data obtained from one substation. Inappropriate control of on-load tap changers that are able to maintain voltage profile might cause unintended result that is harmful to system stability, especially voltage stability. This paper utilizes Z-index that could inform the whole system condition from only one substation data. Simulation is performed using the HYPERSIM that is a digital simulator and matlab simulink to confirm the proposed algorithm.

The Design of Operation and Control Solution with Intelligent Inference Capability for IED based Digital Switchgear Panel (IED를 기반으로 하는 디지털 수배전반의 지적추론기반 운전제어 솔루션 설계)

  • Ko, Yun-Seok
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.9
    • /
    • pp.351-358
    • /
    • 2006
  • In this paper, DSPOCS(Digital Switchgear-Panel Operation and Control Solution) is designed, which is the intelligent inference based operation and control solution to obtain the safety and reliability of electric power supply in substation based on IED. DSPOCS is designed as a scheduled monitoring and control task and a real-time alarm inference task, and is interlinked with BRES(Bus Reconfiguration Expert System) in the required case. The intelligent alarm inference task consists of the alarm knowledge generation part and the real-time pattern matching part. The alarm knowledge generation part generates automatically alarm knowledge from DB saves it in alarm knowledge base. On the other hand, the pattern matching part inferences the real-time event by comparing the real-time event information furnished from IEDs of substation with the patterns of the saved alarm knowledge base.; Especially, alarm knowledge base includes the knowledge patterns related with fault alarm, the overload alarm and the diagnosis alarm. In order to design the database independently in substation structure, busbar is represented as a connectivity node which makes the more generalized graph theory possible. Finally, DSPOCS is implemented in MS Visual $C^{++}$, MFC, the effectiveness and accuracy of the design is verified by simulation study to the typical distribution substation.

Conformance Testing for IEC 61850 based OCR IED (IEC 61850 기반의 OCR IED에 대한 적합성 시험방안)

  • Yu, Fei;Rim, Seong-Jeong;Choi, Myeon-Song;Lee, Seung-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.19-20
    • /
    • 2008
  • IEC 61850 is a new approach international standard which is applicable to Substation Automation System (SAS) and defines the communication between intelligent electric devices (IEDs) in the substation and the related system requirements. It already has a significant impact on the development of different devices or systems used in substation. Conformance claims and the establishment of their validity are important parts of the acceptance of systems and equipment. This paper introduces the conformance testing, mapping of IEC 61850 services and MMS services, and in case study part it gives the example of testing OCR IED.

  • PDF