• Title/Summary/Keyword: Submerged Discharge

Search Result 71, Processing Time 0.027 seconds

Analysis of Tidal Effect in Hangang Bridge by Automatic Discharge Measurement (자동유량측정에 의한 한강대교 조석영향 분석)

  • Lee, Min-Ho;Kim, Chang-Wan;Yoo, Dong-Hoon
    • Journal of Korea Water Resources Association
    • /
    • v.42 no.7
    • /
    • pp.513-523
    • /
    • 2009
  • The measuring point of the Hangang Bridge affected by tide has some special topographic characteristics due to Nodle Island. Furthermore the submerged weirs located on the upstream and downstream. Therefore flow is separated and joined by Nodle Island. Discharge measurement at the point of the Hangang Bridge is very important, because Hangang Bridge is key station in managing the discharge and flood forecasting. In the past, it was too difficult to measure discharge in tidal conditions. HRFCO(Han River Flood Control Office) installed automatic discharge measurement facilities for solving this problem. Measuring equipments operates and measures discharge every 10 minutes at 2 points(southern and northern section close to Nodle Island), and calculates flow discharge using Chiu's velocity law(Chiu, 1988). In order to verify the results of automatic discharge measurements, manual discharge measurements were carried out by ADCP. In addition, the monthly discharge were also compared.

Sensitivity Analysis to the Design Factor of Ocean Outfall System (방류관 설계인자에 대한 민감도 분석)

  • 김지연;이중우
    • Journal of Korean Port Research
    • /
    • v.14 no.3
    • /
    • pp.361-371
    • /
    • 2000
  • A demand of marine outfall system has been much increased for the effective disposal of the wastewater due to population and industrial development at the coastal areas. The outfall system discharges primary or secondary treated effluent into the coastline, or at the deep water, or between these two. The discharge is carried out by constructing a pipeline on the sea bed with a diffuser or with a tunnel, risers and appropriate. The effluent, which has a density similar to that of fresh water, rises to the sea surface forming plume or jet, together with entraining the surrounding salt water and becomes very dilute. Thus there have been growing interests about plume behaviour around the outfall system. Plume or jet discharged from single-port or multi-port diffuser might cause certain impacts on coastal environment. Near field mixing characteristics of discharged water field using CORMIX model have been studied for effective outfall design various conditions on ambient current, depth, flow rate, effluent concentration, diffuser specification, port specification etc.. This kind of analysis is necessary to deal with water quality problems caused by the ocean discharge. The analyzed result was applied to the Pusan Jungang effluent outfall system plan.

  • PDF

Sensitivity Analysis to the Design Factor of Ocean Outfall System (방류관 설계인자에 대한 민감도 분석)

  • 김지연;이중우
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2000.11a
    • /
    • pp.85.2-93
    • /
    • 2000
  • A demand of marine outfall system have been much increased for the effective disposal of the wastewater due to population and industrial development at the coastal areas. The outfall system discharges primary or secondary treated effluent into coastline or at the deep water, or between these two. The discharge is carried out by constructing a pipeline on the sea bed with a diffuser or with a tunnel, risers and appropriate. The effluent, which has a density similar to that of fresh water, rises to the sea surface forming plume or jet, together with entraining the surrounding salt water and becomes very dilute. Thus there have been growing interests about plume behaviour around the outfall system. Plume or jet discharged from single-port or multi-port diffuser might cause certain impacts on coastal environment. Near field mixing characteristics of discharged water field using CORMIX model with has been studied for effective outfall design various conditions on ambient current, depth, flow rate, effluent concentration, diffuser specification, port specification etc.. This kind of analysis is necessary to deal with water quality problems caused by the ocean discharge. The analyzed vesult was applied to the Pusan Jungang dffluent outfall system plan.

  • PDF

Development of a Submerged Propeller Turbine for Micro Hydro Power

  • Kim, Byung-Kon
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.6
    • /
    • pp.45-56
    • /
    • 2015
  • This paper aims to develop a submerged propeller turbine for micro hydropower plant which allows to sustain high values of efficiency in a broad range of hydrological conditions (H=2~6 m, $Q=0.15{\sim}0.39m^3/s$). The two aspects to be considered in this development are mechanical simplicity and high-efficiency operation. Unlike conventional turbines that have spiral casing and gear box, this is directing driving and no spiral casing. A 10 kW class turbine which has the most high potential of the power generation has been developed. The most important element in the design of turbine is the runner blade. The initial blade is designed using inverse design method and then the runner geometry is modified by classical hydraulic method. The design process is carried out in two steps. First, the blade shape is fix and then other components of submerged propeller turbine are designed. Computational fluid dynamics analyses based on the Navier-Stokes equations have been used to obtain overall performance data for the blade and the full turbine, respectively. The results generated by performance parameters(head, guide vane opening angle and rotational speed) variations are theoretically analysed. The evaluation criteria for the blade and the turbine performances are the pressure distribution and flow's behavior on the runner blades and turbine. The results of simulation reveals an efficiency of 91.5% and power generation of 10.5kW at the best efficiency point at the head of 4m and a discharge of $0.3m^3/s$.

An Analysis of Flushing Effects for Instantaneous Contaminants Input into River (하천에 순간적으로 유입된 오염물질의 플러싱 효과 분석)

  • Jung, Jae-Wook;Kim, Soo-Youl;Kim, Jin-Young;Yoon, Sei-Eui
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.4 no.3 s.14
    • /
    • pp.43-50
    • /
    • 2004
  • This study had been performed to analyze flushing effects for instantaneous contaminants input with changing dam discharge in River. RMA-2 and RMA-4 models were applied to the downstream part of the Han River(from Jamsil submerged weir to Singok submerged one) The longitudinal dispersion coefficient of $50m^2/s$ was used. The four cases of dam discharges were selected as $500m^3/s,\;1000m^3/s,\;1500m^3/s$ and $2000m^3/s$, respectively, for 1 hour. The drought flow was fixed $200m^3/s$ in the Han River. The arrival time and the concentration of contaminant, the area of dispersion were estimated with RMA-4 model in the downstream part of the Han River. The arrival time which the concentration of contaminants become under 1ppm was analyzed with the stagnant and the instantaneous inflow contaminant at the section of Sungsan Bridge. The more increasing a dam discharge, the more short a dilution time of contaminant. The relation between the dam discharge and dilution time shows linearity. The instantaneous contaminant input was sensitively affected by the dam discharge than the stagnant contaminant one in the river. If it is tried to flush with a temporally increased dam discharge, it should be understood the range of overflowed contaminant dispersion from main channel to tributary channel.

Estimation of Discharge Coefficients of Overflow Formula for Submerged Structures (수중구조물 월류공식의 유량계수 산정)

  • Yoon, Sung-Bum;Lee, Sang-Min;Kwon, Kab-Keun;Bae, Jae-Seok
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.408-412
    • /
    • 2006
  • 단면평균 1차원 수치모형의 수중구조물 표현방식으로 흔히 사용되는 월류공식의 유량계수를 범용 난류유동 수치모형인 FLUENT를 사용하여 완전월류와 불완전월류의 전구간에 걸쳐 구하고 공식화한 결과를 제시한다. 수중구조물은 고무댐과 Ogee형 월류보의 2가지를 대상으로 하였다.

  • PDF

Characteristics of phenol degradation by using underwater dielectric barrier discharge plasma (수중 유전체 장벽 방전 플라즈마를 이용한 페놀의 분해 특성)

  • Shin, Gwanwoo;Choi, Seungkyu;Kim, Jinsu;Zhu, Qian;Weon, kyoungja;Lee, Sangill
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.4
    • /
    • pp.243-250
    • /
    • 2019
  • This objective of this study was to investigate the degradation characteristics of phenol, a refractory substance, by using a submerged dielectric barrier discharge (DBD) plasma reactor. To indirectly determine the concentration of active species produced in the DBD plasma, the dissolved ozone was measured. To investigate the phenol degradation characteristics, the phenol and chemical oxygen demand (COD) concentrations were evaluated based on pH and the discharge power. The dissolved ozone was measured based on the air flow rate and power discharged. The highest dissolved ozone concentration was recorded when the injected air flow rate was 5 L/min. At a discharge power of 40W as compared to 70W, the dissolved ozone was approximately 2.7 - 6.5 times higher. In regards to phenol degradation, the final degradation rate was highest at about 74.06%, when the initial pH was 10. At a discharged power of 40W, the rate of phenol decomposition was observed to be approximately 1.25 times higher compared to when the discharged power was 70W. It was established that the phenol degradation reaction was a primary reaction, and when the discharge power was 40W as opposed to 70W, the reaction rate constant(k) was approximately 1.72 times higher.

A Study on the Limit of Submerged Flow in Side Channel Spilway (측수로 여수토의 체류한계에 관한 연구)

  • 백은기
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.14 no.3
    • /
    • pp.2716-2725
    • /
    • 1972
  • Side channel spillways based on Hinds theory were tested. Surface water level at the beginning point of side channel is the same as the crest level of weir in the usual design. Here, side channel section were moved upwards $\frac{1}{2}$ of the total head on the crest and test(revised experiment) were made. In the revised experiments, coefficients of discharge for design flood (Q) were the same with that of original design experiments. In case of 1.2Q a little influence of submergence were appeared, coefficients of discharge were decreased to be about 97.6% of that of original design experiments, therefore, Reservoir flood water level become higher about 2-3cm than original case. So revised design can be used for actual purpose and it will brings much savings in construction cost of side channel spillway.

  • PDF

Characteristics of DIC(Dissolved Inorganic Carbon) Behavior On Sea Water with Bicarbonate Discharge (중탄산이온 농축해수의 해양방류에 따른 DIC 거동 특성)

  • Kwon, Sung-Min;Kim, Kang-Min;Lee, Joong-Woo
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2018.05a
    • /
    • pp.234-236
    • /
    • 2018
  • 기후변화는 더 이상 피할 수 없는 매우 중요한 문제다. 온실가스 중 큰 비중을 차지하는 이산화탄소 배출을 억제하거나 제거하기 위한 많은 연구들이 진행되고 있다. 최근에는 CCS 중 하나인 지중저장(underground storage)의 대안으로 해양에 이산화탄소를 저장하는 기술인 AWL(Accelerated Weathering of Limestone)을 이용한 해양저장(ocean storage)에 대한 연구가 진행되고 있다. AWL은 이산화탄소를 중탄산이온 형태의 농축수로 만들어 해양에 방류하여 희석 저장시키는 방법으로, 대기 중 재방출이 거의 발생하지 않고 배출된 농축수는 해양의 알칼리도를 높여 해양산성화를 방지할 수 있는 장점이 있다. 금회 연구는 AWL에 의한 방법 중 중탄산이온 농축수의 해양방류 시 이산화탄소 등을 포함하는 용존 무기탄소(DIC, Dissolved Inorganic Carbon)의 거동특성을 파악하기 위한 목적으로 수행하였다. 연구대상 해역은 충분한 수심과 작업효율성이 확보되는 울릉도 부근으로 설정하였으며, 거동특성을 파악하기 위하여 표층방류(surface discharge)와 수중방류(submerged discharge)에 의한 물질확산을 계산할 수 있는 CORMIX모형을 채택하였다. 실험결과, 방류 시점으로부터의 희석률을 고려했을 때, 표층방류 시나리오가 농축수 방류에 가장 적합한 방식이라고 사료된다.

  • PDF

A study on the treatment of water discharge from the water treatment plant using end-free submerged membrane - Causes and solution of membrane fouling - (자유 말단형 침지식 분리막을 이용한 정수장 배출수 처리 연구 - 막오염 발생 원인과 해결 방안 -)

  • Kim, Jun-Hyun;Jang, Jung-Woo;Kim, Jin-Ho;Park, Kwang-Duck
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.2
    • /
    • pp.93-104
    • /
    • 2020
  • As water resources are limited and legal regulations are strengthened, there is a growing need to reuse residuals in WTP(Water Treatment Plant). In this study, membrane filtration system was constructed and its operation method was studied for water quality stabilization and reuse of WTP residuals. The operation parameters were stable for 1 year and 6 months. Membrane fouling was identified as particulate pollution (activated carbon) and inorganic pollution (manganese). The membrane system was operated steadily with raw water of high concentration SS(Suspended solid) containing activated carbon because membrane fouling was reduced by the effect of End-Free type. In the case of inorganic contamination, dissolved manganese eluted by chemicals and acted as a membrane fouling source, and the operating conditions for minimizing membrane fouling. were confirmed by newly developing application methods and types of cleaning chemicals. Based on the results, design parameters for reducing manganese membrane fouling were derived.