• Title/Summary/Keyword: Subjective Rating

Search Result 325, Processing Time 0.026 seconds

Psychoacoustical Analysis and Application of Electroencephalography(EEG) to the Sound Quality Analysis for Acceleration Sound of a Passenger Car (자동차 가속음질에 대한 심리음향적 분석과 뇌파응용 음질 평가)

  • Lee, Seung-Min;Lee, Sang-Kwon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.3
    • /
    • pp.258-266
    • /
    • 2013
  • This paper presents the correlation between psychological and physiological acoustics for the automotive acceleration sound. The research purpose of this paper is to evaluate the sound quality of acceleration sound of a passenger car based EEG signal. The previous method for the objective evaluation of sound quality is to use sound metrics based on psychological acoustics. This method uses not only psychological acoustics but also physiological acoustics. For this work, the sounds of 7 premium passenger cars are recorded and evaluated subjectively by 33 people. The correlation between the subjective rating and sound metrics is calculated based on physiological acoustics. Finally the correlation between the subjective rating and the EEG signal measured on the brain is also calculated. Throughout these results the new evaluation system for the sound quality on the automotive acceleration sound of a passenger car has been developed based on bio-signal.

Sound Quality Evaluation of Turn-signal of a Passenger Vehicle based on Brain Signal (뇌파 측정을 이용한 차량 깜빡이 소리의 음질 평가)

  • Shin, Tae-Jin;Lee, Young-Jun;Lee, Sang-Kwon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.11
    • /
    • pp.1137-1143
    • /
    • 2012
  • This paper presents the correlation between psychological and physiological acoustics for the automotive sound. The research purpose of this paper is to evaluate the sound quality of turn-signal sound of a passenger car based EEG signal. The previous method for the objective evaluation of sound quality is to use sound metrics based on psychological acoustics. This method uses not only psychological acoustics but also physiological acoustics. For this work, the sounds of 7 premium passenger cars are recorded and evaluated subjectively by 30 persons. The correlation between this subjective rating and sound metrics is calculated based on psychological acoustics. Finally the correlation between the subjective rating and the EEG signal measured on the brain is also calculated. Throughout these results the new evaluation system for the sound quality on interior sound of a passenger car has been developed based on bio-signal.

Development of Seat Belt Pulling Noise Index and Evaluation System Research (시트 벨트 인출 소음 평가 기술 및 인덱스 개발 연구)

  • Cho, Hye-Young;Lee, Sang-Kwon;Kang, Hee-Su;Son, Joo-Hwan
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.23 no.2
    • /
    • pp.185-190
    • /
    • 2015
  • The purpose of this study is developing the quantify the seat belt pulling Noise index and evaluation method. This paper presents the objective method to evaluate the emotional feeling about the pulling Noise of the seat belt. The physical quantification is required to objectively evaluate the emotional feeling of the pulling Noise. This is called the "Noise metric." The Noise metric is should correlated to the subjective rating of the pulling Noise. The pulling Noise index is developed throughout the linear regression of the Noise metric and the subjective rating. The developed index is used for the objective evaluation of the emotional feeling about the pulling Noise of a seat belt throughout the modification of seat belt components.

A study on coupling effect during lifting (들기 작업시 손잡이의 영향에 관한 연구)

  • 장성록;배동철
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.2
    • /
    • pp.119-124
    • /
    • 2003
  • Despite rapid technological advance and increased automation facilities, many jobs and activities in our living require manual materials handling(MMH). These include wide variety of activities such as moving things, lifting bags. boxes or cartons, etc. Many studies found that handle could affect on maximum acceptable weight of lifting, but there were few studies f3r the effects of work posture and coupling in lifting tote box. This study performed that ten male college students were required to lift a tote box with and without handle for three postures (bending, straight, right angle posture). From the experiment, following results were obtained. (1) MVC reduced maximum 23% by type of handle. (2) MVC was highest in straight posture, but was lowest in right angle posture. (3) As a result of ANOVA, MVC paid attention to posture and coupling. (p<0.01) (4) To all handle types, biceps brachii activity was increased in right angle posture. but reduced in straight posture. (5) To all posture, biceps brachii activity was most lively in no handle. The results of MVC measurement, subjective rating, EMG analysis, statistic analysis showed that maximum acceptable weight of lifting was influenced by type of handle and straight posture was more comfortable than other postures. Based on these results, it was concluded that acceptable weight of lifting has to differ for work posture and coupling.

Comparison between denture wearer's evaluation and clinician's rating for complete denture (총의치 사용에 대한 환자와 술자간 평가 비교)

  • Byun, Jin-Soo;Huh, Yoon-Hyuk;Cho, Lee-La;Park, Chan-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.4
    • /
    • pp.364-369
    • /
    • 2016
  • Purpose: The aim of this study was to compare denture wearer's evaluation and clinician's technical rating for complete denture used on edentulous patients. Materials and methods: Total 43 edentulous patients who had complete denture fabricated more than one year ago were recalled. The questionnaire based on the various literatures was modified and applied to patients for subjective assessments. Functional aspects related to retention, stability, occlusion and denture condition were included in operator's evaluation. In addition, correlations were evaluated between patient's subjective and operator's objective assessments. Friedman test and Cohen's Kappa value were used for statistical analysis. Results: It was found that denture wearers' evaluations were slightly or fairly agree to clinician's rating for complete denture. More differences were found in maxillary denture than mandibular denture and moderate difference was found in esthetic, occlusion aspects. Conclusion: There were slightly or fairly agreement between subjective and objective evaluations.

Exploring Perception on the Swimming Rating System

  • Hyo Rim KIM;Jae Woong KIM;Myung Seok SEO
    • Journal of Sport and Applied Science
    • /
    • v.7 no.4
    • /
    • pp.1-5
    • /
    • 2023
  • Purpose: The purpose of the study is to analyze the perception of swimming rating system. Research design, data, and methodology: In this study, practitioners and leaders of Korean swimming federation were selected as the subjects of the study to institutionalize the grade of swimming. Data analysis was categorized according to word frequency after coding using the Nvivo 12.0 program, and words were visualized using the word cloud program. PASW/WIN 21.0 was employed to analyze demographic characteristics. Triangular verification and expert meetings were conducted three times to increase the validity of the study. In these meetings, the study excluded subjective interpretation and errors of the researcher. Results: First, as a result of analyzing the perception of practitioners before educational training, 16 words and the total frequency of words was 21 times. Second, as a result of analyzing the perception of practitioners after educational training, 22 words and a total of 25 frequencies were found. Third, as a result of analyzing the leader's perception before educational training, 32 words and the total frequency of words was 63 times. Fourth, as a result of analyzing the leader's perception after educational training, 41 words and a total of 72 frequencies were found. Conclusions: Findings indicated divers feelings and thoughts of practitioners and leaders of Korean swimming federations towards swimming rating system. Further implications were discussed.

Realtime No-Reference Quality-Assessment Over Packet Video Networks (패킷 비디오 네트워크상의 실시간 무기준법 동영상 화질 평가방법)

  • Sung, Duk-Gu;Kim, Yo-Han;Hana, Jung-Hyun;Shin, Ji-Tae
    • Journal of Broadcast Engineering
    • /
    • v.14 no.4
    • /
    • pp.387-396
    • /
    • 2009
  • No-Reference video-quality assessments are divided into two kinds of metrics based on decoding pixel domain or the bitstream one. Traditional full-/reduced- reference methods have difficulty to be deployed as realtime video transmission because it has problems of additional data, complexity, and assessment accuracy. This paper presents simple and highly accurate no-reference video-quality assessment in realtime video transmission. Our proposed method uses quantization parameter, motion vector, and information of transmission error. To evaluate performance of the proposed algorithm, we perform subjective test of video quality with the ITU-T P.910 Absolute Category Rating(ACR) method and compare our proposed algorithm with the subjective quality assessment method. Experimental results show the proposed quality metric has a high correlation (85%) in terms of subjective quality assessment.

Express Train Seat Discomfort Evaluation using Body Pressure and Anthropometric Data

  • Park, Se Jin;Min, Seung Nam;Lee, Heeran;Subramaniyam, Murali;Suh, Woo Sung
    • Journal of the Ergonomics Society of Korea
    • /
    • v.33 no.3
    • /
    • pp.215-227
    • /
    • 2014
  • Objective: The purpose of this study was to evaluate Korea's Honam express train's first- and second-class seat discomfort by using pressure measurement, subjective discomfort rating, and physical compatibility. Background: Over the years, the demand for an express train service is continually increasing. A comfortable ride is important to achieving passenger satisfaction. A train seat plays a significant role in fulfilling passenger seating comfort. With this in view, a field survey and pressure measurements were performed on the selected train seat. Method: The pressure ratio at the body-seat interface (thigh and buttock regions) was measured by the pressure mat system. The interface pressure ratio was calculated and compared. The subjective discomfort rating scale was used to evaluate the subjects' overall feeling. The dimensions of train seats were analysed according to the anthropometric and demographic characteristics of the population data from Size Korea. Results: The results highlighted that the interface pressure ratio was greater while participants sat on the second-class seat than the first-class seat in the left- and right-side thigh regions. Also the pressure ratio was greater for the participants in the 1st~25th percentile height groups (149.8~160.8cm). The subjects rated higher discomfort for the second-class seat than the first-class seat. The physical compatibility results showed that the second-class seat's breadth was inadequate for the 95th and 99th percentile male. Conclusion: Overall, interface pressure measurement, subjective discomfort score and physical compatibility results showed that the second-class seat was more uncomfortable for the passengers than the first-class seat. Application: The adopted methodologies could be used to measure the seating comfort of the train seats.

Comparison of Clinical Usefulness of Program-Assisted and Real Ear Measurement-Assisted Hearing Aids Fitting (프로그램과 실이 측정을 이용한 보청기 적합의 임상적 유용성의 비교)

  • Chang, Young-Soo;Jung, Hye Im;Cho, Yang-Sun
    • Korean Journal of Otorhinolaryngology-Head and Neck Surgery
    • /
    • v.61 no.12
    • /
    • pp.663-668
    • /
    • 2018
  • Background and Objectives The main objectives of this study were to determine the clinical usefulness of the program-assisted and real ear measurement (REM)-assisted fitting of hearing aids. Subjects and Method Fifteen participants with moderate to moderately severe hearing loss were enrolled in this study. Objective and subjective fitting results were assessed to compare the benefits between the program-assisted fitting (using a software fitting program) and the REM-assisted fitting. Real ear insertion gain (REIG), sound-field audiometry using warble tone, and Korean Hearing in Noise Test (K-HINT) were performed as objective tests. Sound quality rating was performed as a subjective test. Results In the program fitting, 48.89% of fitting points failed to come within ${\pm}10dB$ of the REIG target. In the REM fitting, however, the percentage of failure significantly decreased to 23.33% (p=0.013). In K-HINT test, the reception threshold for speech in quiet situation significantly decreased from 50.1 dB HL with the program fitting to 44.7 dB HL after the REM fitting (p<0.001). In front noise condition, signal-to-noise ratio improved from 4.53 dB to 3.50 dB with the REM fitting without statistical significance (p=0.099). In the sound quality rating, the REM fitting ($4.27{\pm}0.56$) showed a significantly better sound quality ratings than the program fitting ($3.69{\pm}0.74$) (p=0.017). Conclusion The REM fitting showed better results in both subjective and objective measurements than the program fitting.

Evaluation of manual workload in repetitive wrist and finger motion (반복적인 손목 및 손가락 작업에서의 수작업 부하 평가)

  • Gwon, O-Chae;Yun, Myeong-Hwan
    • Journal of the Ergonomics Society of Korea
    • /
    • v.18 no.2
    • /
    • pp.103-120
    • /
    • 1999
  • The purpose of this study was to evaluate the manual workload in repetitive wrist and finger motion. To evaluate manual workload, angular displacement of the joint, EMG of the muscle and subjective rating were studied. Both wrist motion and finger motion were studied. A screw-driving task was used for the wrist motion experiment. A keyboard typing task was used for the finger motion experiment. All finger joint angles and wrist angles were measured by an angle-measuring glove($CyberGlove^{TM}$, Virtual Technologies, Inc.). Surface EMG was recorded from FCU muscle and FDS muscle simultaneously with the angle measurement. Subjective ratings of exertion were also recorded using the modified Borg's CR-10 scale. Repetition rates of 0.5, 1, 2 motions per second were used with each task. As a result, manual workload increased with increasing repetitiveness. Peak spectral magnitude and frequency components corresponded closely with joint angular displacement amplitudes and repetition rates. Results of the correlation analysis showed that there were significant correlation among EMG, frequency-weighted motion and subjective measurement. Both EMG and frequency-weighted filtering showed consistent workload estimation with increasing task frequency. Subjective ratings showed slight over-estimation of the workload as the task frequency is increased.

  • PDF