• Title/Summary/Keyword: Subacromial space

Search Result 22, Processing Time 0.023 seconds

Synovial Chondromatosis in the Subacromial Space with Hyaline Cartilage Loose Body - A Case Report - (초자연골 유리체를 동반한 견봉하 공간의 활막 연골종증 - 증례 보고 -)

  • Kim, Jun-Bum;Park, Jong-Suk;Kwon, Sai-Won;Soh, Jae-Wan;Kim, Min-Soo;Yang, Seong-Suk
    • Journal of the Korean Arthroscopy Society
    • /
    • v.16 no.2
    • /
    • pp.175-179
    • /
    • 2012
  • Synovial chondromatosis developes by metaplasia of synovial cell into chondroblast in synovium of joint. It most commonly involves large joints such as knee or hip, and rarely occurs in shoulder joint. It is often difficult to be diagnosed preoperatively and surgical synovectomy is known to be effective treatment. We encountered a case of synovial chondromatosis with hyaline cartilage forming loose body in subacromial and subdeltoid synovium on the shoulder of a 44-year old female suffered by pain and discomfort. The authors report this case with a review of the relevant literature.

  • PDF

Glenohumeral versus subacromial steroid injections for impingement syndrome with mild stiffness: a randomized controlled trial

  • Yong-Tae Kim;Tae-Yeong Kim;Jun-Beom Lee;Jung-Taek Hwang
    • Clinics in Shoulder and Elbow
    • /
    • v.26 no.4
    • /
    • pp.390-396
    • /
    • 2023
  • Background: The subacromial (SA) space is a commonly used injection site for treatment of impingement syndrome. For shoulder stiffness, glenohumeral (GH) injections are commonly performed. However, in cases of impingement syndrome with mild shoulder stiffness, the optimal site of steroid injection has yet to be identified. Methods: This prospective, randomized study compared the short-term outcomes of ultrasound-guided GH and SA steroid injections in patients who were diagnosed with impingement syndrome and mild stiffness. Each group comprised 24 patients who received either a GH or SA injection of 40 mg of triamcinolone. Range of motion and clinical scores were assessed before and 3, 7, and 13 weeks after the injection. Results: GH and SA injections significantly improved the range of motion and clinical scores after 13 weeks of follow-up. Notably, targeting the GH joint resulted in an earlier gain of forward elevation, external rotation, and internal rotation in 3 weeks (P<0.001, P=0.012, and P=0.002, respectively) and of internal rotation and a Constant-Murley score in 7 weeks (P<0.001 and P=0.046). Subsequent measurements were similar between the groups and showed a steady improvement in all ranges of motion and clinical scores. Conclusions: GH injections may be more favorable than SA injections for treatment of impingement syndrome with mild stiffness, especially in improving the range of motion in the early period. However, the procedures showed similar outcomes after 3 months. Level of evidence: I.

Beach-chair lateral traction position using a lateral decubitus distracter in shoulder arthroscopy

  • Kim, Kyung-Cheon;Rhee, Kwang-Jin;Shin, Hyun-Dae;Byun, Ki-Yong
    • The Academic Congress of Korean Shoulder and Elbow Society
    • /
    • 2008.03a
    • /
    • pp.164-164
    • /
    • 2008
  • The beach-chair traction position is designed to allow the use of traction while allowing the surgeon to orient the shoulder in an upright position and convert to an open procedure, if necessary. The patient is placed in the beach-chair position under general anesthesia. A three-point shoulder holder (Arthrex, Naples, Florida) is attached to the rail of the operating table on the same side as the surgeon, whereas it is placed on the side opposite the surgeon in the lateral decubitus position. A shoulder traction and rotation sleeve (Arthrex) are affixed to the arm following the manufacturer's instructions. Positioning the thumb toward the closed side of the sleeve ensures a field for the anterior portion of the rotator cuff and prevents the tendency of the suspension apparatus to place the arm in internal rotation. The arm is maintained in 30 to 40 degree abduction and 30 to 40 degree flexion by controlling the length and height of the bar and the location of the universal clamp. The universal clamp allows multiple planes of adjustment to control abduction and forward movement of the arm. The sleeve is attached to the longitudinal traction cable using a sterile hook, and a lateral strap is secured around the proximal portion of the sleeve to the overhead traction cable to ensure a field for glenohumeral reconstruction. The use of a lateral strap permits ideal shoulder positioning for improved access to the anterior and inferior glenohumeral joint. The lateral strap can be released or removed to widen the subacromial space during subacromial decompression or rotator cuff repair. A 10-lb weight is attached to the longitudinal traction cable for an average-sized person.

  • PDF

Clinical Outcome after Arthroscopic Capsular Release for Adhesive Capsulitis of the Shoulder

  • Yoo, Jae Chul;Koh, Kyoung Hwan;Shon, Min Soo;Bae, Kyu Hwan;Lim, Tae Kang
    • Clinics in Shoulder and Elbow
    • /
    • v.21 no.3
    • /
    • pp.127-133
    • /
    • 2018
  • Background: This study was undertaken to evaluate the outcome of the arthroscopic capsular release for adhesive capsulitis of the shoulder. Methods: This study retrospectively investigated thirty shoulders in 29 patients who presented with recalcitrant adhesive capsulitis and underwent arthroscopic treatments. Other than typical findings of adhesive capsulitis, combined pathologies in the glenohumeral joint and subacromial space were evaluated by arthroscopy. Clinical evaluations were performed using the Constant's score and ranges of motion (ROM) at preoperative, 6 months postoperatively and at the final follow-up. Results: Our study included 17 women and 12 men with a mean age of 53.8 years (range, 34-74). Mean follow-up duration was 24 months (range, 12-40 months). Assessment of combined pathologies revealed that partial rotator cuff tear of less than 25% thickness, was most common (overall 83.3%; with bursal 57% and articular 23%). Subacromial synovitis and adhesion were also frequent (53.3%). The Constant score and ranges of motion significantly improved at the final follow-up, compared with preoperative levels. However, clinical results at 6 months postoperatively were found to be significantly inferior to those observed at the final follow-up ($p{\leq}0.001$ for all factors). Functional impairment was the major complaint in 59.3% patients at the 6 months follow-up. Conclusions: Although arthroscopic capsular release yielded favorable outcome at the mean 24 months follow-up, pain and motion limitations at 6-month postoperatively persisted in more than 50% of our patients. While combined pathologies were commonly encountered during arthroscopy, although their effects on surgical outcome in adhesive capsulitis remains unclear in this study.

Effects of a Trunk Stabilization Exercise with Gym Ball on Scapular Position for Patients with Arthroscopic Rotator Cuff Repair

  • Jung, Mi Young;Ryu, Young Uk
    • The Journal of Korean Physical Therapy
    • /
    • v.30 no.1
    • /
    • pp.8-13
    • /
    • 2018
  • Purpose: The present study was to investigate effects of scapular position and pain on a trunk stabilization exercise with gym ball for patients with arthroscopic rotator cuff repair. Methods: Subjects were patients after 2 weeks of rotator cuff repairs. Subjects were randomly assigned to conservative treatment group (CTG, n=10) or trunk stabilization with gym ball group (SBG, n=10), and participated one of those groups for 2 weeks. Measurements about pain and scapular position were assessed in before and after treatment programs. Results: Pain reduced in both rest and night in SBG compared to CTG. In the case of scapular position, decreased scapular retraction (increased protraction) was found in CTG and vice versa in SBG. Reduced scapular anterior tilting was also found on SBG. Conclusion: The present study showed that early performed trunk stabilization with gym ball could bring a scapular alignment that increases subacromial space and reduces pain. This suggests early trunk stabilization with gym ball programs to restore shoulder functions for patients with rotator cuff repair.

Impingement Syndrome & Rotator Cuff Tear: Etiology (견관절 충돌 증후군 및 회전근 개 파열의 병인)

  • Cho, Nam Su;Lee, Sang Hoon
    • Journal of the Korean Arthroscopy Society
    • /
    • v.16 no.1
    • /
    • pp.72-78
    • /
    • 2012
  • The rotator cuff is situated in a potential tight subacromial space and undergoes senescent structural changes commonly observed in other joints of the body. When the cuff fails, spontaneous healing of the torn tendon is not expected to occur, and multiple factors may be responsible. Its fibers are under tension and typically retract on tearing. The subacromial bursal inflammation and alterations in normal glenohumeral kinematics have been considered in the development of symptoms. Controversy continues to exist concerning the pathogenesis of rotator cuff disease. The heterogeneity of the disorder, as well as the notion that rotator cuff disease may not actually represent a continuum of the same process, but rather, is a compilation of independent disorders, may partly explain the differing viewpoints on its origin. Two contrasting pathogenetic mechanisms have been extensively described and include vascular, or intrinsic, causes and impingement, or extrinsic, factors. Other etiologies have also been reported that include trauma, congenital or developmental factors, and instability. For successful treatment of the rotator cuff diseases, it is essential to understand the structure and function of rotator cuff and to clarify the pathogenesis and natural history of its disorder.

  • PDF

Arthroscopic Treatment of Septic Arthritis of the Shoulder: Technical Pearls to Reduce the Rate of Reoperation

  • Kwon, Ji Eun;Park, Ji Soon;Park, Hae Bong;Nam, Kyung Pyo;Seo, Hyuk Jun;Kim, Woo;Lee, Ye Hyun;Jeon, Young Dae;Oh, Joo Han
    • Clinics in Shoulder and Elbow
    • /
    • v.23 no.1
    • /
    • pp.3-10
    • /
    • 2020
  • Background: The aim of this study was to evaluate clinical experience with arthroscopic debridement for septic arthritis of the shoulder joint and to report on our patient outcomes. Methods: The retrospective analysis included 36 shoulders (male:female, 15:21), contributed by 35 patients (mean age, 63.8 years) treated by arthroscopy for septic arthritis of the shoulder between November 2003 and February 2016. The mean follow-up period was 14.3 months (range, 12-33 months). An additional posterolateral portal and a 70° arthroscope was used to access the posteroinferior glenohumeral (GH) joint and posteroinferior subacromial (SA) space, respectively. Irrigation was performed with a large volume of fluid (25.1±8.1 L). Multiple suction drains (average, 3.3 drains) were inserted into the GH joint and SA space and removed 8.9±4.3 days after surgery. Intravenous antibiotics were administered for 3.9±1.8 weeks after surgery, followed by oral antibiotic treatment for another 3.6±1.9 weeks. Results: Among the 36 shoulders, reoperation was required in two cases (5.6%). The average range of motion achieved was 150.0° for forward flexion and T9 for internal rotation. The mean simple shoulder test score was 7.9±3.6 points. Nineteen shoulders (52.8%) had acupuncture or injection history prior to the infection. Pathogens were identified in 15 shoulders, with Staphylococcus aureus being the most commonly identified pathogen (10/15). Both the GH joint and the SA space were involved in 21 shoulders, while 14 cases involved only the GH joint and one case involved only the SA space. Conclusions: Complete debridement using an additional posterolateral portal and 70° arthroscope, a large volume of irrigation with >20 L of saline, and multiple suction drains may reduce the reoperation rate.

Efficacy of the Subclavian Portal Approach in Arthroscopic Repair of Isolated Subscapularis Tendon Tear

  • Chae, Seung Bum;Choi, Chang Hyuk;Jung, Suk-Han
    • Clinics in Shoulder and Elbow
    • /
    • v.17 no.1
    • /
    • pp.18-24
    • /
    • 2014
  • Background: To evaluate the efficacy of the subclavian portal approach for the arthroscopic repair of isolated subscapularis tendon tear. Methods: We used the subclavian portal to carry out arthroscopic repair of the isolated subscapularis tendon tear. The surgery was carried out in 18 cases (average age of 53) from May 2006 to December 2009 with a mean follow-up period of 35 months. Of these cases, 13 patients had the tear in their dominant arms, 16 were male, and 12 were from traumatic ruptures with on average 7.6 months of symptom period to operation. Additional surgery, acromioplasty and subacromial debridement, were carried out on 4 cases each during the subscapularis repair. The integrity of cuff status was assessed by ultrasonographic examination at 6 months and at 1 year after operation. Results: The initial average range of motion in forward flexion, external rotation, and internal rotation were $160^{\circ}$, $50^{\circ}$ and L4, respectively. At the 1 year follow-up period, these improved to $160^{\circ}$, $52^{\circ}$ and T12, respectively. The initial average functional scores were assessed by KSS, ASES, UCLA, and Constant scoring systems, which were 67, 60, 26, and 65, respectively. These scores improved progressively with time. At 3 months after operation, the scores were 74, 67, 27, and 74; at 6 months, 83, 77, 31, and 75; at 1 year, 88, 86, 32, and 79; and at the final follow-up of 35 months, 84, 92, 34, and 84. Conclusions: In the repair of isolated subscapularis tendon tear, the subclavian portal approach provided a good angle for anchor insertion and sufficient space to manage the upper portion of the tendon tear. In turn, these provisions resulted in satisfactory clinical results.

Correlation between Results of Preoperative Impingement Test and Clinical Outcomes after Arthroscopic Rotator Cuff Repair

  • Park, Sung Bae;Seo, Joong Bae;Ryu, Jee Won;Shin, Yong Eun
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.3
    • /
    • pp.126-132
    • /
    • 2017
  • Background: The aim of the present study was to determine the correlation between the amount of pain reduction after local anesthetic injection into the subacromial space preoperatively and clinical outcome after arthroscopic rotator cuff repair. Methods: A total of 127 patients who underwent arthroscopic rotator cuff repair and followed up at least 1 year were analyzed retrospectively. Preoperatively, a visual analogue scale (VAS) for pain was measured in all patients before and after the ultrasound guided impingement test. The participants were divied into four groups according to pain reduntion ater impingement test (Group A: >75%, Group B: 50%-75%, Group C: 25%-50%, Group D: <25%). VAS for pain, shoulder range of motion, shoulder isometric strength, ASES score were evaluated preoperatively and at 3, 6, 9, and 12 months postoperatively. Results: After surgery, the amount of pain reduction shows significantly at 3, 6 months in Groups A, B as compared to Groups C, D (p<0.05). Among the range of motion of shoulder joint, forward flexion was significantly improved in Group A at 3 months (p<0.05). The ASES score significantly improved at 3, 6 months in Groups A, B as compared to Group C, D (p<0.05). Conclusions: Preoperative degree of pain reduction after impingement test correlates with the improvement of pain after arthroscopic rotator cuff repair, especially in the early phase. Therefore, the impingement test could be effectively used.

Effectiveness of Multimodal Pain Control in Early Phase After Arthroscopic Rotator Cuff Repair (관절경하 회전근 개 봉합술 후 다중 통증 조절법을 이용한 초기 통증 조절의 유용성)

  • Park, Chang-Min;Kim, Jong-Hae;Kim, Suk-Jun;Choi, Chang-Hyuk
    • Clinics in Shoulder and Elbow
    • /
    • v.15 no.1
    • /
    • pp.1-7
    • /
    • 2012
  • Purpose: The purpose of this study was to identify the effectiveness of multimodal pain control method in an early phase after arthroscopic rotator cuff repair, under interscalene brachial plexus block, this study was performed. Materials and Methods: The study was progressed with the 80 cases of arthroscopic rotator cuff repair. Interscalene brachial plexus block was used to all of the 80 cases and patients were divided into 2 groups. Group A consisted of patients injected with bupivacaine, through subacromial space catheter after surgery, and group B consisted of patients with additional method of multimodal pain control using oral opioids, acetaminophen-tramadol complex and selective COX2 inhibitor. Subacromial cathter was removed after injection in both groups. The pain during the day time and night time was compared on the operation day, postoperative 1st, 2nd, 3rd day and 2nd weeks, and it was measured with VAS (visual analogue scale) score. Additionally, the number of ketolorac injection and side-effect related to analgesics was compared between the 2 groups. Results : The mean VAS score of night time on the operation day and day/night time pain of the 1st, 2nd, 3rd day and 2nd weeks was 7.4, 7.0/6.8, 4.5/5.2, 4.8/5.0, 2.2/2.7 on group A and 6.5, 4.3/5.4, 3.2/4.3, 3.0/4.1, 2.4/2.5 on group B, respectively. Significant difference was observed in the night pain on the operation day, 1st, 2nd, 3rd day time and 1st night time pain (p<.05). The average number of ketololac injection was 1.1 and 0.5 in each group, and there was no difference in the frequency of side effects. Conclusion: Multimodal pain control method, after arthroscopic rotator cuff repair, showed an effective early pain control and improved patients' satisfaction.