• 제목/요약/키워드: SubChanFlow

검색결과 56건 처리시간 0.035초

Assessing the impact of DIONISIO-SubChanFlow code coupling in nuclear fuel performance simulations

  • Mauricio Exequiel Cazado;Victor Hugo Sanchez-Espinoza;Alejandro Soba
    • Nuclear Engineering and Technology
    • /
    • 제56권11호
    • /
    • pp.4843-4850
    • /
    • 2024
  • Realistic simulation of nuclear fuel performance requires not only validated models capable of describing the thermomechanical phenomena that take place within the fuel under irradiation conditions, but a detailed description of the thermal hydraulics of the channel surrounding the fuel rods, which provides the boundary conditions of the system. In this work, the main results and outlooks of coupling the thermal hydraulics code SubChanFlow with the fuel performance code DIONISIO are presented. To achieve this, an internal coupling was implemented, wherein DIONISIO is used as a master code controlling SubChanFlow as a thermal hydraulics subroutine replacing the simplified version already embedded in DIONISIO. Several tests were conducted to ensure the performance and quality of the coupling under normal operation conditions as a first approach. In addition, it was observed that the coupling demonstrated a significant improvement in the description of the cladding temperature and related variables, such as oxide thickness and hydrogen uptake, when compared with experimental data.

제 2종 LiBr-H2O 흡수식 히트펌프의 운전 변수에 따른 성능 특성 수치 해석 (Effects of Operation Conditions on the Performance of Type II LiBr-H2O Absorption Heat Pump)

  • 윤준성;권오경;차동안;배경진;김인관;김민수;박찬우
    • 설비공학논문집
    • /
    • 제29권1호
    • /
    • pp.7-14
    • /
    • 2017
  • This study carried out a numerical analysis of the effects of hot waste water supply on the performance of a Type II absorption heat pump. There are two types of hot waste water supply, regular series flow and reverse series flow. Also it investigated the interaction between each type of flow and heat exchange solutions. As the effectiveness of heat exchange solutions increase, the steam generation and (COP) increase as well. If the effectiveness of a heat exchange solution is lower than 0.566, the steam generation rate of the reverse flow is lower than that of the regular series flow. A high effectiveness of heat exchange solution is therefore required to make a larger amount of steam in reverse series flow than with ordinary series flow. The COP difference between the two types of flow decreases with the increasing effectiveness of the heat exchange solution. Thus, a reverse flow type absorption heat pump can match the high steam generation rate and COP of the ordinary flow type when a highly effective heat exchange solution is applied.

정수지의 형상과 유입 유량이 T10에 미치는 영향 연구 (Effect of Shape and Flow Rate on T10 in Clearwell)

  • 신은허;김성훈;박희경;안재찬;최재호;최영준
    • 상하수도학회지
    • /
    • 제19권6호
    • /
    • pp.819-826
    • /
    • 2005
  • To guarantee the disinfection ability in clearwell, a value of CT is considered where C[mg/l] is disinfectant residual at the exit of clearwell and T[min] means $T_{10}$, the contact time when 10% of tracer is out of clearwell after introducing the tracer at the inlet. To meet a CT value required, increasing the C value is not recommended because high C value can increase potential of producing disinfection by product like THMs. Increasing the hydraulic efficiency surrogated by $T_{10}$ is thus an option widely recommended. Right now, it is widely adopted estimating $T_{10}$ considering LW ratio only due to the suggestions of previous researches. The authors think however there are other factors to consider including shape, flow rate, configuration of inlet and outlet, and the existence of intra basin. This study is initiated to closely look at the effects of two factor on hydraulic efficiency. The factors are shape and inlet flow velocity, i.e., inflow. For that, computational fluid dynamics (CFD) model is developed and pilot test is also carried out. The results show that at a L/W ratio, disinfection ability is overestimated with larger length in shape and higher inlet flow velocity. This suggests that in determining $T_{10}$, the shapes of clearwell and inlet flow velocity should also be considered as well as L/W ratio.

분무열분해 공정의 제조 조건이 Ca8Mg(SiO4)4Cl2:Eu2+ 형광체 특성에 미치는 영향 (Effects of Preparation Conditions in the Spray Pyrolysis on the Characteristics of Ca8Mg(SiO4)4Cl2:Eu2+ Phosphor)

  • 한진만;구혜영;이상호;강윤찬
    • 한국재료학회지
    • /
    • 제18권2호
    • /
    • pp.92-97
    • /
    • 2008
  • In spray pyrolysis, the effects of the preparation temperature, flow rate of the carrier gas and concentration of the spray solution on characteristics such as the morphology, size, and emission intensity of $Ca_8Mg(SiO_4)_4Cl_2:Eu^{2+}$ phosphor powders under long-wavelength ultraviolet light were investigated. The phosphor powders obtained post-treatment had a range of micron sizes with regular morphologies. However, the composition, crystal structure and photoluminescence intensity of the phosphor powders were affected by the preparation conditions of the precursor powders. The $Ca_8Mg(SiO_4)_4Cl_2:Eu^{2+}$ phosphor powders prepared at temperatures that were lower and higher than $700^{\circ}C$ had low photoluminescence intensities due to deficiencies related to the of Cl component. The phosphor powders with the deficient Cl component had impurity peaks of $Ca_2SiO_4$. The optimum flow rates of the carrier gas in the preparation of the $Ca_8Mg(SiO_4)_4Cl_2:Eu^{2+}$ phosphor powders with high photoluminescence intensities and regular morphologies were between 40 and 60 l/minute. Phosphor powders prepared from a spray solution above 0.5 M had regular morphologies and high photoluminescence intensities.

솔레노이드 밸브를 이용한 고압가스의 유량제어 (Flow Control for High Pressure Gas by using a Solenoid Valve)

  • 심한섭;이치우;김남경;안국찬;남궁재관
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2005년도 춘계학술대회 논문집
    • /
    • pp.156-161
    • /
    • 2005
  • Dynamic flow characteristics of a solenoid valve are affected by pressure difference in inlet and outlet of orifice, gas temperature, and supply voltage of a coil. In this paper, the dynamic flow characteristics for deviations of various conditions are studied Static and dynamic flow for variation on-time of a solenoid valve open signal are measured in basic bench test. The solenoid valve is applied to a compressed natural gas(CNG) engine test for validation of flow control performance. The experimental results show that flow of high pressure gas can controlled precisely by using a solenoid valve.

  • PDF

The Involvement of Nitric Oxide and Guanylate Cyclase on the Adenosine A2B Receptor-induced Cerebral Blood Responses in the Rats

  • Park, Chan-Sook;Shin, In-Chul
    • Biomolecules & Therapeutics
    • /
    • 제13권2호
    • /
    • pp.95-100
    • /
    • 2005
  • This study was performed to investigate the mechanism of cerebral blood flow of adenosine $A_{2B}$ receptor agonist in the rats, and to define whether its mechanism is mediated by nitric oxide (NO) and guanylate cyclase. In pentobarbital-anesthetized, pancuronium-paralyzed and artificially ventilated male Sprague-Dawley rats, all drugs were applied topically to the cerebral cortex. Blood flow from cerebral cortex was measured using laser-doppler flowmetry. Topical application of an adenosine $A_{2B}$ receptor agonist, 5'-N-ethylcar-boxamidoadenosine (NECA; $4{\mu}mol/l$) increased cerebral blood flow. This effect of NECA ($4{\mu}mol/l$) was blocked by pretreatment with NO synthase inhibitor, $N^G$-nitro-L-argine methvlester (L-NAME; $40{\mu}mol/l$) and guanylate cyclase inhibitor, LY-83,583 ($10{\mu}mol/l$). These results suggest that adenosine $A_{2B}$ receptor increases cerebral blood flow. It seems that this action of adenosine $A_{2B}$ receptor is mediated via the NO and the activation of guanylate cyclase in the cerebral cortex of the rats.

RF magnetron 스파터링법으로 제작한 TiNx 박막의 XPS 분석 (XPS Analysis of TiNx Thin Films by RF Magnetron Sputtering)

  • 박문찬;오정홍;황보창권
    • 한국안광학회지
    • /
    • 제3권1호
    • /
    • pp.115-120
    • /
    • 1998
  • RF(radio-frequency) magnetron 스퍼터링 장치에 질소가스와 아르곤가스를 동시에 주입하면서 Ti 타켓을 스퍼터링하여 $TiN_x$ 박막을 유리기판위에 제작하였다. 박막제작시 RF power supply 출력을 240W로, 증착기 내부의 온도는 $200^{\circ}C$를 유지하였다. $TiN_x$ 박막은 알곤 가스를 20sccm으로 고정시킨 상태에서 질소를 3sccm부터 9sccm까지 변화시켜가며 증착시켰다. 이때 박막의 화학적 조성과 성분비를 분석하기 위하여 XPS를 사용하였다.

  • PDF

RF magnetron 스파터링법으로 제작한 TiNx 박막의 면저항분석 (Sheet Reisistance Analysis of TiNx Thin Film by RF Magnetron Sputtering)

  • 박문찬;오정홍;김남영;황보창권
    • 한국안광학회지
    • /
    • 제4권1호
    • /
    • pp.21-25
    • /
    • 1999
  • RF(radio-frequency) magnetron 스퍼터링 장치에 질소가스와 아르곤가스를 동시에 주입하면서 Ti 타켓을 스퍼터링하여 TiN, 박막을 유리기판위에 제작하였다. 박막제작시 RF power supply 출력은 240W로, 증착기 내부의 온도는 $200^{\circ}C$를 유지하였다. TiN, 박막은 알곤 가스를 20sccm으로 고정시킨 상태에서 질소를 3sccm부터 9secm까지 변화시켜가며 증착시켰다. 이때 박막의 면저항과 화학적 조성과의 관계를 분석하기 위하여 XPS depth profiling과 4점 탐침법을 사용하였다.

  • PDF

Numerical Simulation on the Onset of Radial Fingering in a Hele-Shaw Cell or a Porous Medium

  • Min Chan Kim
    • Korean Chemical Engineering Research
    • /
    • 제62권1호
    • /
    • pp.112-117
    • /
    • 2024
  • Numerical simulations on the onset and the growth of viscous fingering during the miscible displacement due to the radial source flow were conducted. With introduction of a new stability criterion, the critical log-viscosity ratio, Rc, was found as a function of the Peclet number, Pe. Similar to the previous linear stability analyses, Pe made the system unstable, i.e., accelerated the onset of instability. For a large Pe system, the present numerical simulation yielded much stable results than the previous theoretical predictions This discrepancy was commonly encountered in the comparison between the theoretical prediction and the experimental finding. Additionally, the difference between the rectilinear system and the present one was also discussed. The present system was found more insensitive to the Peclet number than the rectilinear one.

철도차량 객차내 오염물질의 분포경향에 관한 전산해석 (Distribution of Pollutant on the Indoor Air of Passenger Car)

  • 소진섭;전철균;박찬수;최주석
    • 한국연소학회지
    • /
    • 제8권2호
    • /
    • pp.7-16
    • /
    • 2003
  • The transfer of air pollutants between passenger room and service room in train are investigated by the computational analysis. The effects of service room temperature, inlet velocity, initial concentration and heating are studied. The flow induced by the difference of density between two rooms is found to take the major role in transfer of polluted air. Low temperature of service room enhances the polluted air flow into passenger room along the floor. Exhaust fan above the door between two rooms is not effective for this case. Strong inlet flow is found to suppress polluted air flow from service room. The heating of passenger room can promote air pollution.

  • PDF