• 제목/요약/키워드: Sub-domain Method

검색결과 282건 처리시간 0.024초

음성신호의 Sub-Nyquist 비균일 표준화 및 완전 복구에 관한 연구 (Sub-Nyquist Nonuniform Sampling and Perfect Reconstruction of Speech Signals)

  • 이희영
    • 음성과학
    • /
    • 제12권2호
    • /
    • pp.153-170
    • /
    • 2005
  • The sub-Nyquist nonuniform sampling (SNNS) and the perfect reconstruction (PR) formula are proposed for the development of a systematic method to obtain minimal representation of a speech signal. In the proposed method, the instantaneous sampling frequency (ISF) varies, depending on the least upper boundary of spectral support of a speech signal in time-frequency domain (TFD). The definition of the instantaneous bandwidth (IB), which determines the ISF and is used for generating the set of samples that represent continuous-time signals perfectly, is given. Also, the spectral characteristics of the sampled data generated by the sub-Nyquist nonuniform sampling method is analyzed. The proposed method doesn't generate the redundant samples due to the time-varying property of the instantaneous bandwidth of a speech signal.

  • PDF

Fuzzy Control Strategy for Damping Sub-Synchronous Resonance

  • Qader, M.R.
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권5호
    • /
    • pp.1791-1797
    • /
    • 2018
  • Sub-Synchronous Resonance (SSR) is a phenomenon that harms turbine generator shafts because the phenomenon induces sub-synchronous wavering in the system. In the study presented in this paper, a dynamic resistance bank is used to mitigate the occurrence of sub-synchronous phenomenon. A fuzzy logic controller using rotor speed deviation and its derivative as inputs is implemented to damp sub-synchronous oscillations more efficiently. An eigenvalue technique is used to analyse the stability of the system, and a simulation in MATLAB is conducted, based on the IEEE Second Benchmark, to validate the effectiveness of the proposed method under a 3-phase fault condition at an infinite bus. The time-domain simulation and eigenvalues are used to observe the proposed method's superior ability to damp sub-synchronous oscillation.

2층 유전체를 사용한 십자형 급전선을 갖는 광대역 마이크로스트립 슬롯 안테나의 해석 (Analysis of Wideband Microstrip Slot Antenna with Cross-shaped Feedline using 2-layer Dielectrics)

  • 장용웅;신호섭
    • 대한전자공학회논문지TE
    • /
    • 제37권2호
    • /
    • pp.69-74
    • /
    • 2000
  • T-모양의 마이크로스트립 급전 구조를 갖는 슬롯 안테나는 정합을 쉽게 이룰 수 있고 대역폭이 기존의 급전 구조의 슬롯 안테나에 비하여 넓었다. 양방향으로 복사체를 갖는 슬롯 안테나가 한 방향으로만 복사하기를 원할 경우, 반사판을 별도로 설치해야 한다. 그러나 본 논문에서 제시한 한 방향으로만 복사체를 갖는 슬롯 안테나는 반사판 설치가 필요 없게 된다. 그래서 반사판을 포함하는 2-층의 유전체 층에 십자형 급전구조를 갖는 마이크로스트립 슬롯 복사체인 새로운 방법을 제시하였다. FDTD 법으로 해석하여 전계분포를 시간 영역에서 계산하였고, 이를 Fourier 변환시켜 슬롯 안테나의 반사손실, 전압 정재파비, 복사패턴을 주파수 영역에서 계산하였다. 그리고 슬롯의 길이(I/sub s/)와 폭(W/sub s/), 수평부 급전선의 길이(I/sub d/), 상측 수직 급전선의 길이(l/sub u/), offset 에 따라 대역폭이 민감하게 변한다. 설계변수들을 최적화한 후에 측정한 결과, 최대 대역폭은 중심 주파수 2.5㎓에서 1,850㎒의 광대역 특성을 얻었다.

  • PDF

Fast and Efficient Satellite Imagery Fusion Using DT-CWT Proportional and Wavelet Zero-Padding

  • Kim, Yong-Hyun;Oh, Jae-Hong;Kim, Yong-Il
    • 한국측량학회지
    • /
    • 제33권6호
    • /
    • pp.517-526
    • /
    • 2015
  • Among the various image fusion or pan-sharpening methods, those wavelet-based methods provide superior radiometric quality. However, the fusion processing is not only simple but also flexible, since many low- and high-frequency sub-bands are often produced in the wavelet domain. To address this issue, a novel DT-CWT (Dual-Tree Complex Wavelet Transform) proportional to the fusion method by a WZP (Wavelet Zero-Padding) is proposed. The proposed method produces a single high-frequency image in the spatial domain that is injected into the LRM (Low-Resolution Multispectral) image. Thus, a wavelet domain fusion can be simplified to spatial domain fusion. In addition, in the proposed DT-CWTP (DT-CWT Proportional) fusion method, it is unnecessary to decompose the LRM image by adopting WZP. The comparison indicates that the proposed fusion method is nearly five times faster than the DT-CWT with SW (Substitute-Wavelet) fusion method, meanwhile simultaneously maintaining the radiometric quality. The conducted experiments with WorldView-2 satellite images demonstrated promising results with the computation efficiency and fused image quality.

RLSA 설계를 위한 주기적으로 배열된 슬롯을 통한 결합의 효율적인 해석 (Efficient Analysis of Couplings through Periodically Arranged Slots in a Radial Line Slot Antenna)

  • 이중원;김용훈;박종국;남상욱
    • 한국전자파학회논문지
    • /
    • 제12권6호
    • /
    • pp.931-939
    • /
    • 2001
  • DBS(Direct Broadcast Satellite) 수신용 radial-line slot antenna(RLSA)의 설계를 위한 슬롯을 통한 결합 특성을 해석하였다. RLSA에서 이미 제안된, narrow wall이 주기 경계 조건(periodic boundary condition)을 만족시키고 wide wall에 슬롯이 주기적으로 배열되어 있는 구형 도파관 모델을 이용하였다. 자장 적분 방정식과 필요한 그린 함수를 유도하여 모멘트 법으로 풀었다. 이때 수치 해석의 효율을 극대화하고 그린 함수에 의한 특이점 문제를 해결하기 위해 entire domain 기저 함수와 sub-domain 기저 함수를 모두 사용하였다. 한편 그린 함수를 빠르게 계산하기 위한 가속화 방법으로 구형 도파관 영역은 Ewald합 기법을, 반공간 영역은 Shanks 변환을 이용하였다. 시뮬레이션 결과로부터 RLSA의 설계에 이용되는 다양한 변수들이 결합에 미치는 영향을 예측할 수 있었다.

  • PDF

보건진료소의 고혈압예방 및 관리사업 평가도구 개발 (Development an Evaluation Tool for Evaluation of Hypertension Prevention and Management Program in Community Health Posts)

  • 조원정;권명순
    • 지역사회간호학회지
    • /
    • 제15권2호
    • /
    • pp.197-208
    • /
    • 2004
  • Purpose: This study was to develop an effective evaluation tool for evaluation of hypertension prevention and management program(HPMP) in community health posts (CHPs). Method: Evaluation tool composed from the literature review, the field visiting, and the in-depth interviews with the community health practitioners. Result: The evaluation tool had four domains, each with different maximum points:, hypertension prevention (35), hypertension management (40), environment of the CHPs(10), and evaluation system of the HPMP(15). The first domain was hypertension prevention with sub-domains of health education, and early detection of patients with hypertension. The second domain was hypertension management with sub-domains of management of health records of patients, education and counseling, and treatment and follow-up of patients. The third domain was the environment of the CHPs with subdomains of accessibility of CHPs to residents, accessibility of general health data to the public, and availability of health information to the public by multimedia. The fourth domain was the evaluation system of the HPMP with the subdomains of planning of program, formative evaluation, process evaluation, and summative evaluation. Conclusion: The newly developed evaluation tool will contribute not only to plan and set goals for evaluation of HPMP in CHPs.

  • PDF

4 차원 Light Field 영상에서의 일관된 각도-공간적 편집 전파 (Spatio-Angular Consistent Edit Propagation for 4D Light Field Image)

  • 윌리엄;박인규
    • 한국방송∙미디어공학회:학술대회논문집
    • /
    • 한국방송공학회 2015년도 추계학술대회
    • /
    • pp.180-181
    • /
    • 2015
  • In this paper, we present a consistent and efficient edit propagation method that is applied for light field data. Unlike conventional sparse edit propagation, the coherency between light field sub-aperture images is fully considered by utilizing light field consistency in the optimization framework. Instead of directly solving the optimization function on all light field sub-aperture images, the proposed optimization framework performs sparse edit propagation in the extended focus image domain. The extended focus image is the representative image that contains implicit depth information and the well-focused region of all sub-aperture images. The edit results in the extended focus image are then propagated back to each light field sub-aperture image. Experimental results on test images captured by a Lytro off-the-shelf light field camera confirm that the proposed method provides robust and consistent results of edited light field sub-aperture images.

  • PDF

Sensor placement selection of SHM using tolerance domain and second order eigenvalue sensitivity

  • He, L.;Zhang, C.W.;Ou, J.P.
    • Smart Structures and Systems
    • /
    • 제2권2호
    • /
    • pp.189-208
    • /
    • 2006
  • Monitoring large-scale civil engineering structures such as offshore platforms and high-large buildings requires a large number of sensors of different types. Innovative sensor data information technologies are very extremely important for data transmission, storage and retrieval of large volume sensor data generated from large sensor networks. How to obtain the optimal sensor set and placement is more and more concerned by researchers in vibration-based SHM. In this paper, a method of determining the sensor location which aims to extract the dynamic parameter effectively is presented. The method selects the number and place of sensor being installed on or in structure by through the tolerance domain statistical inference algorithm combined with second order sensitivity technology. The method proposal first finds and determines the sub-set sensors from the theoretic measure point derived from analytical model by the statistical tolerance domain procedure under the principle of modal effective independence. The second step is to judge whether the sorted out measured point set has sensitive to the dynamic change of structure by utilizing second order characteristic value sensitivity analysis. A 76-high-building benchmark mode and an offshore platform structure sensor optimal selection are demonstrated and result shows that the method is available and feasible.

Seismic analysis of dam-foundation-reservoir coupled system using direct coupling method

  • Mandal, Angshuman;Maity, Damodar
    • Coupled systems mechanics
    • /
    • 제8권5호
    • /
    • pp.393-414
    • /
    • 2019
  • This paper presents seismic analysis of concrete gravity dams considering soil-structure-fluid interaction. Displacement based plane strain finite element formulation is considered for the dam and foundation domain whereas pressure based finite element formulation is considered for the reservoir domain. A direct coupling method has been adopted to obtain the interaction effects among the dam, foundation and reservoir domain to obtain the dynamic responses of the dam. An efficient absorbing boundary condition has been implemented at the truncation surfaces of the foundation and reservoir domains. A parametric study has been carried out considering each domain separately and collectively based on natural frequencies, crest displacement and stress at the neck level of the dam body. The combined frequency of the entire coupled system is very less than that of the each individual sub-system. The crest displacement and neck level stresses of the dam shows prominent enhancement when coupling effect is taken into consideration. These outcomes suggest that a complete coupled analysis is necessary to obtain the actual responses of the concrete gravity dam. The developed methodology can easily be implemented in finite element code for analyzing the coupled problem to obtain the desired responses of the individual subdomains.