• 제목/요약/키워드: Sub-cooler

검색결과 49건 처리시간 0.028초

중형 이산화탄소 급탕기의 최적 설계 (Optimum Design of Middle-Sized CO2 Water Heater)

  • 박한빛;윤린;김영득
    • 설비공학논문집
    • /
    • 제25권4호
    • /
    • pp.173-179
    • /
    • 2013
  • Middle-sized $CO_2$ water heater having compressor power of 7.45 kW was designed, and its performances were experimentally tested. Besides, optimum design of the $CO_2$ water heater was conducted by cycle simulation. When ambient temperature of $7^{\circ}C$ and hot water outlet temperature of $80^{\circ}C$ the $CO_2$ water heater showed the COP of 3.2. As hot water temperature increased the COP is getting decreased due to significant increase of compressor power consumption compared to increasing rate of heating capacity. When ambient temperature increased from $-3^{\circ}C$ to $12^{\circ}C$ the COP increased by 30%. The optimum components design of a gas cooler, an internal heat exchanger, and an evaporator were conducted, and the experimental correlation between amount of EEV opening and ambient temperature, and hot water temperature was suggested.

Collective effect of hydrogen in argon and Mg as ambiance for the heat treatment on MgB2

  • Sinha, B.B.;Jang, S.H.;Chung, K.C.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제16권2호
    • /
    • pp.24-28
    • /
    • 2014
  • Magnesium diboride superconductor is still of considerable interest because of its appealing characteristics towards application mainly at around 20 K. Unlike Nb-based superconductors, $MgB_2$ can be operated by cryogen-free cooler which provides a cost effective alternative at low field of around 2-5 T. To explore this operating field region considerable efforts are necessary to marginally improve the superconducting properties of $MgB_2$. Under this situation, even the heat treatment environment during the synthesis is considered as an important factor. The addition of $H_2$ gas in small amount with Ar as a mixed gas during annealing has an adverse effect on the superconducting properties of $MgB_2$. It is although interesting to find that the presence of Mg vapor along with hydrogen during heat treatment results in the appreciable improvement in the flux pinning and the overall response of the critical current density for the ex-situ $MgB_2$ samples.

이산화탄소 냉매 시스템용 내부 열교환기의 냉방성능에 관한 실험적 연구 (Experimental Study on Cooling Performance of Internal Heat Exchanger for CO2 Refrigerant System)

  • 김대훈;권영철
    • 한국산학기술학회논문지
    • /
    • 제9권3호
    • /
    • pp.587-592
    • /
    • 2008
  • 이산화탄소 냉매 시스템용 내부 열교환기의 성능을 조사하기 위하여 4종류의 내부 열교환기를 사용하여 냉방운전조건에서 실험을 수행하였다. 내부 열교환기의 길이, 관 개수, 운전조건, 형상 변화에 대한 영향이 연구되었다. 내부 열교환기 길이가 증가할수록 능력과 효율은 향상되었다. 압력강하는 고압측보다 저압측에서 더 크게 나타났다. 가스쿨러의 온도가 높아질수록 능력과 효율은 선형적으로 증가하였으며, 증발기의 운전조건은 과열도보다는 이상영역을 설정하면 효율증대 효과 측면에서 유리하였다. 마이크로 채널의 경우가 튜브보다 능력과 효율이 크게 우수하였지만 압력강하 측면에서는 크게 불리하였다.

광학적 기법에 의한 Frost 두께 측정방법의 개발 (Development of Frost Thickness Measurement Method Using Optical Technique)

  • 정재홍;윤상열;김경천
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.654-659
    • /
    • 2001
  • A new non-contact method of the frost thickness measurement has been developed. The method is based on the digital image processing technique to identify the reflection edge of the image captured by a CCD camera under laser sheet light illumination. To insure the accuracy of frost layer thickness, an in-situ calibration procedure is carried out with a calibration target with 0.5mm holes. Using the mapping function obtained by the calibration procedure, the contour of frost surface can be estimated with sub-pixel resolutions. The developed method is applied to study the effect of cooling plate temperature on the frost thickness in a small low speed wind tunnel.

  • PDF

A Simple Thermal Model of Fuel Thermal Management System in Aircraft Engine

  • Youngjin Kim;Jeonghwan Jeon;Gonghoe Gimm
    • 항공우주시스템공학회지
    • /
    • 제17권5호
    • /
    • pp.11-18
    • /
    • 2023
  • The architecture of the Fuel Thermal Management System (FTMS) in a commercial aircraft engine was built to model and simulate the fuel system. The study shows the thermal interactions between the fuel and engine lubrication oil through the mission profile of a high bypass ratio, two-spool turbofan engine. Fuel temperature was monitored as it flowed through each sub-component of the fuel system during the mission. The heat load in the fuel system strongly depended on the fuel flow rate, and was significantly increased for the periods of cruise and descent with decrease of fuel flow rate, rather than for the periods of take-off. Due to the thermal interaction in the pump housing, the fuel temperature at the outlet of the low-pressure pump was increased (4.0, 9.2, and 30.0) % over the case without thermal interaction for take-off, cruise, and descent, respectively.

The investigation of combined ventilation-biofilter systems using recycled treated wastewater on odor reduction efficiency

  • Febrisiantosa, Andi;Choi, Hong L.;Renggaman, Anriansyah;Sudiarto, Sartika I.A.;Lee, Joonhee
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제33권7호
    • /
    • pp.1209-1216
    • /
    • 2020
  • Objective: The present study aimed to evaluate the performance of odor abatement by using two different ventilation-biofilter systems with recycled stablized swine wastewater. Methods: The performance of odor removal efficiency was evaluated using two different ventilation-biofilter-recycled wastewater arrangements. A recirculating air-flow ventilation system connected to a vertical biofilter (M1) and a plug-flow ventilation system connected to a horizontal biofilter (M2) were installed. Water dripping over the surface of the biofilter was recycled at a flow rate of 0.83 L/h in summer and 0.58 L/h in winter to reduce odorous compounds and particulate matter (PM). The experiments were performed for 64 days with M1 and M2 to investigate how these two ventilation-biofilter systems influenced the reduction of odor compounds in the model houses. Odorous compounds, NH3 and volatile organic compounds (VOCs) were analyzed, and microclimatic variables such as temperature, humidity, and PM were monitored. Results: Ammonia concentration inside M1 was about 41% higher on average than that in M2. PM and total suspended particles (TSPs) inside M1 were about 62.2% and 69.9%, respectively, higher than those in M2. TSPs in the model house were positively correlated with the concentration of NH3 and VOCs. Conclusion: M2 emitted lower concentration of odorous compounds than M1. Moreover, M2 could maintain the optimum temperature condition for a swine house during the cooler season. The plug-flow ventilation-horizontal biofilter system could be used for pig houses to minimize air pollution produced by swine farming activities and maintain optimum microclimate conditions for pigs.

Monitoring of air Pollution on the Premises of the Factory Sharrcem - L.L.C

  • Luzha, Ibush;Shabani, Milazim;Baftiu, Naim
    • International Journal of Computer Science & Network Security
    • /
    • 제22권10호
    • /
    • pp.214-222
    • /
    • 2022
  • In these proceedings, we will address the problem of air pollution on the premises of the Cement factory SHARRCEM L.L.C. in Hani Elezit in the Republic of Kosovo respectively around the clinker cooler, rotary kiln, and raw material mill. By air pollution, we mean the introduction of chemicals, particles, or other harmful materials into the atmosphere which in one way or another causing damage to the development of plants and organisms. Air pollution occurs when certain substances are released into the air, which depending on the quantitative level, can be harmful to human health, animals, and the environment in general. The analysis of air shows the influence of the extractive and processing industry on the chemical composition of air. Parameters analyzed though under control such as the case of carbon dioxide, due to the increasing production capacity of cement, the production of hundreds of thousands of cubic meters of CO2 gas made CO2 production a concern. With the purchase of the latest technology by the SHARCEM Factory in Hani Elezit, the amount of air pollution has been reduced and the allowed parameters of environmental pollution have been kept under control. Air pollutants are introduced into the atmosphere from various sources which change the composition of the atmosphere and affect the biotic environment.The concentration of air pollutants depends not only on the quantities that are emitted from the sources of air pollution but also on the ability of the atmosphere to absorb or disperse these emissions. Sources of air pollutants include vehicles, industry, indoor sources, and natural resources. There are some natural pollutants, such as natural fog, particles from volcanic eruptions, pollen grains, bacteria, and so on.

거창 열수 맥상광상의 함 금-은 광화작용 (Au-Ag-bearing Ore Mineralization at the Geochang Hydrothermal Vein Deposit)

  • 홍석진;이선진;최상훈
    • 자원환경지질
    • /
    • 제55권2호
    • /
    • pp.171-181
    • /
    • 2022
  • 거창광상은 영남육괴 화강암질 편마암 또는 편마암질 화강암 내에 발달한 열극을 충전하여 생성된 함 금-은 열수 맥상광상으로, 괴상 및 호상 조직과 함께 부분적인 각력상 조직 및 정동의 발달 등 복합적인 조직적 특성을 보여준다. 거창광상의 맥상 광화작용은 구조운동(tectonic break)에 의하여 광화 1시기와 광화 2시기로 구분된다. 광화 1시기는 석영맥의 생성과 함께 주된 함 금·은 광물인 에렉트럼과 함께 황화광물 및 산화광물 등이 미량의 황염광물을 수반 산출한 시기로서, 공생관계와 광물조합 특성 등에 의하여 세 단계의 광화시기(초기, 중기, 후기)로 구분된다. 광화 1시기의 초기에는 주로 황철석, 자류철석, 유비철석 등이 산출되었다. 중기에는 주된 금-은 광화작용이 진행되어 에렉트럼과 함께 황동석, 섬아연석 등의 황화광물과 미량의 함 은 황염광물 등이 산출되었다. 후기에는 황철석, 섬아연석, 방연석 등과 함께 적철석 등이 산출되었다. 광화 2시기는 주 광화작용 이후의 금속 광화작용이 이루어지지 않은 방해석맥의 생성 시기이다. 거창광상의 주된 광화작용은 고온(≥380℃)의 H2O-CO2-NaCl계 열수유체 유입으로 시작되어 초기의 냉각과 비등작용, 중기의 불혼화용융 및 후기의 상대적으로 천부를 순환한 열수유체 또는 천수의 혼입 등에 의하여 ≥380℃~≤210℃의 온도조건에서 7.0 to 0.7 wt. percent NaCl 상당 염농도를 갖는 유체에서 진행되었다. 거창광상의 광물 공생관계 변화는 이러한 열수계의 진화에 의한 온도와 황 분압 조건의 감소 등의 환경변화가 반영된 결과이다. 거창광상은 중열수형 금·은 광상에 대비된다.

쌍전 함 텅스텐 열수 맥상광상의 생성환경 (Genetic Environments at the Ssangjeon Tungsten-bearing Hydrothermal Vein Deposit)

  • 이선진;최상훈
    • 자원환경지질
    • /
    • 제55권6호
    • /
    • pp.689-699
    • /
    • 2022
  • 쌍전광상은 영남육괴 선캠브리아기 변성퇴적암류인 원남층, 분천 화강편마암, 각섬암 또는 페그마타이트 내 열극을 충전하여 생성된 함 텅스텐 열수 맥상광상이다. 쌍전광상의 맥상 광화작용은 지구조적 운동(tectonic break)에 의하여 광화 1기(stage I)와 광화 2기(stage II)로 구분된다. 광화 1기는 석영맥의 생성과 함께 주된 함 텅스텐 광물인 철망간중석 및 회중석과 함께 황화광물 및 산화광물 등이 수반 산출한 시기로서, 공생관계와 광물조합 특성 등에 의하여 세 단계의 광화시기(초기, 중기, 후기)로 구분된다. 광화 1기의 초기에는 유비철석과 황철석이 산출되었다. 중기에는 주된 텅스텐 광화작용이 진행되어 철망간중석, 회중석과 함께 함 티탄 산화광물과 천금속 황화광물 등이 산출되었다. 후기에는 함 비스무트 광물과 함께 2차 광물인 백철석 등이 산출되었다. 광화 2시기는 주 광화작용 이후의 금속 광화작용이 이루어지지 않은 석영맥의 생성 시기이다. 쌍전광상의 주된 광화작용은 고온(≥370℃)의 H2O-CO2-NaCl계 열수유체 유입으로 시작되어 초기 내지 중기의 냉각과 비등작용 및 불혼화용융, 후기의 상대적으로 천부를 순환한 열수유체 또는 천수의 혼입 등에 의하여 ≥370℃~≤170℃의 온도 조건에서 18.5 to 0.2 wt. percent NaCl 상당 염농도를 갖는 유체에서 진행되었다. 쌍전광상의 광물 공생관계 변화는 이러한 열수계의 진화에 의한 온도와 황 분압 조건의 감소 등의 환경변화가 반영된 결과이다.

쇼케이스의 실제 운전상태를 고려한 축냉시스템 적용 가능성 평가 기초 연구 (A Feasibility Study for the Application of the Cold-heat Storage System Considering the Real Operation Status of the Showcase)

  • 이동원;김정배
    • 한국태양에너지학회 논문집
    • /
    • 제32권5호
    • /
    • pp.52-58
    • /
    • 2012
  • Experimental study was performed to understand the real operation conditions of a showcase working usually in a convenient store and discount store. The purpose of this study was to show the possibility for practical use of cold-heat storage systems being operated for the showcase. To do that, evaporator and condenser temperatures were measured and the compressor electric power consumption were measured simultaneously. To use the ice storage system, the ice making process was typically operated during midnight being not needed the cooling of the showcase through the continuous running of the condenser unit. And then, the refrigerant was subcooled using the stored cold-heat after being discharged from the condenser during daytime. So, the cooling performance was increased with the sub-cooling of refrigerant during daytime,hence the actual running time of the compressor could be effectively decreased. Through the experiments, this study showed that the compressor electric power consumption during daytime could be transferred to nighttime for applying the refrigerant sub-cooling. So, for the convenient store, the maximum load transfer rates for each working cooler and showcase were estimated about 31.1% and 19.9% respectively. And for the discount store, the maximum load transfer rates for each refrigeration and freezing showcase were estimated about 34.1% and 49.0% respectively.