• 제목/요약/키워드: Sub- resonance

검색결과 513건 처리시간 0.025초

First Example of Monometallic Palladium(II) Compound with Trans-Chelating Tridentate Ligand: Synthesis, Crystal Structure, and Characterizations

  • Tae Hwan Noh
    • Mass Spectrometry Letters
    • /
    • 제14권3호
    • /
    • pp.110-115
    • /
    • 2023
  • The reaction of (COD)PdCl2 with new C3-symmetric tridentate L (COD = 1,5-cyclooctadien; L = 1,3,5-tris(picolinoyloxyethyl)cyanurate) in a mixture of acetone and dichloromethane produces single crystals consisting of unprecedented monometallacyclic [PdCl2(L)]. This cyclic compound arises from trans-chelation of two of three donating pyridyl groups of L, while the third pyridyl group remains uncoordinated. Electrospray ionization mass spectrometry (ESI-MS) data on L exhibited the major peak corresponding to [C27H24N6O9 + H+]+. Fast atom bombardment mass spectrometry (FABMS) data on [PdCl2(L)], however, showed the mass peak corresponding to the L instead of the present palladium(II) compound species, due to the insolubility and dissociation in solution. The physicochemical properties of the present palladium(II) compound were fully characterized by means of infrared (IR) and nuclear magnetic resonance (NMR) spectroscopy, thermal analysis, single-crystal X-ray diffraction (SC-XRD) measurement.

7 T MRI에서의 다양한 RF 코일에 대한 B1+ 비교 (B1+ Comparison for Different RF Coils at 7 T MRI)

  • 김홍준;유형석
    • 한국전자파학회논문지
    • /
    • 제23권8호
    • /
    • pp.1010-1013
    • /
    • 2012
  • 정 자장($B_0$)의 세기가 7 T(Tesla) 고자기장 MRI(Magnetic Resonance Imaging) 시스템은 정 자장의 세기가 1.5 T 또는 3 T MRI 시스템에 비하여 인가된 RF(Radio Frequency) 필드의 높은 불균질성을 보여준다. 이러한 문제점를 극복하기 위한 한 방법으로써, 관심 영역에서의 RF 자장이 균일하도록 RF 코일의 각 요소로 들어가는 최적화된 전류의 크기와 위상 값을 얻기 위해서 convex 최적화 방법이 사용된다. 이러한 방법을 7 T MRI 시스템에 다양한 RF 코일에 적용하여 각각의 $B_1^+$ 필드 값을 비교하여 그 성능을 파악하였다.

Structural nature of chemically inequivalent borons in the nonlinear optical material β-BaB2O4 studied using 11B MAS NMR and 11B single-crystal NMR

  • Kim, Woo Young;Lim, Ae Ran
    • 한국자기공명학회논문지
    • /
    • 제17권2호
    • /
    • pp.86-91
    • /
    • 2013
  • Detailed information about the structural nature of three-coordinate borons in ${\beta}-BaB_2O_4$ is obtained through $^{11}B$ MAS NMR and $^{11}B$ single-crystal NMR. The three-coordinate $BO_3$ of the two borons B(1) and B(2) in ${\beta}-BaB_2O_4$ were distinguished. The spin-lattice relaxation time in the laboratory frame $T_1$ for B(1) and B(2) slowly decreases with increasing temperature, whereas the spin-lattice relaxation time in the rotating frame $T_{1{\rho}}$ for B(1) and B(2), which differs from $T_1$, is nearly constant. The B(1) and B(2) of the two types were distinguished by $^{11}B$ MAS NMR and $^{11}B$ single-crystal NMR.

전도성 페이스트용 코어-쉘 TiO2/Ag 나노입자의 합성 및 특성 연구 (Core-shell TiO2/Ag Nanoparticle Synthesis and Characterization for Conductive Paste)

  • 심상보;한종대
    • 공업화학
    • /
    • 제34권1호
    • /
    • pp.36-44
    • /
    • 2023
  • 코어-쉘 TiO2/Ag 나노입자를 수정된 졸-겔 공정과 함께 acetoxime을 환원제로 사용한 물/dodecylbenzenesulfonic acid (DDBA)/cyclohexane의 역 미셀 방법으로 합성하였다. 합성된 TiO2/Ag 나노입자의 구조, 형태 및 크기를 XRD, UV-visible spectroscopy, SEM, TEM 및 TGA를 이용하여 조사하였다. TiO2/Ag 나노입자의 크기는 [물]/[DDBA]의 몰비를 조절하여 제어할 수 있었다. TiO2/Ag 나노입자의 크기와 다분산성은 [물]/[DDBA]의 몰비가 증가함에 따라 증가하였다. 아나타제 결정상의 TiO2 나노입자 위에 생성된 Ag 나노입자는 430 nm 주변에서 강한 표면 플라즈몬 공명(SPR) 흡수 특성을 나타내었다. SPR 피크는 나노입자 크기의 증가에 따라 장파장으로의 적색 이동이 나타났다. 70 wt% 조성으로 TiO2/Ag 나노입자를 분산시켜 전도성 페이스트를 제조하고, 스크린 인쇄법으로 PET 필름에 코팅하여 전도성을 조사하였다. TiO2/Ag 나노입자 페이스트로 코팅된 필름은 상용 Ag 페이스트의 경우보다 높은 405~630 μΩ/sq 영역의 표면저항을 나타내었다.

전자 사이클로트론 공명 플라즈마와 열 원자층 증착법으로 제조된 Al2O3 박막의 물리적·전기적 특성 비교 (Electrical Properties of Al2O3 Films Grown by the Electron Cyclotron Resonance Plasma-Enhanced Atomic Layer Deposition (ECR-PEALD) and Thermal ALD Methods)

  • 양대규;김양수;김종헌;김형도;김현석
    • 한국재료학회지
    • /
    • 제27권6호
    • /
    • pp.295-300
    • /
    • 2017
  • Aluminum-oxide($Al_2O_3$) thin films were deposited by electron cyclotron resonance plasma-enhanced atomic layer deposition at room temperature using trimethylaluminum(TMA) as the Al source and $O_2$ plasma as the oxidant. In order to compare our results with those obtained using the conventional thermal ALD method, $Al_2O_3$ films were also deposited with TMA and $H_2O$ as reactants at $280^{\circ}C$. The chemical composition and microstructure of the as-deposited $Al_2O_3$ films were characterized by X-ray diffraction(XRD), X-ray photo-electric spectroscopy(XPS), atomic force microscopy(AFM) and transmission electron microscopy(TEM). Optical properties of the $Al_2O_3$ films were characterized using UV-vis and ellipsometry measurements. Electrical properties were characterized by capacitance-frequency and current-voltage measurements. Using the ECR method, a growth rate of 0.18 nm/cycle was achieved, which is much higher than the growth rate of 0.14 nm/cycle obtained using thermal ALD. Excellent dielectric and insulating properties were demonstrated for both $Al_2O_3$ films.

New Classes of LC Resonators for Magnetic Sensor Device Using a Glass-Coated Amorphous CO83.2B3.3Si5.9Mn7.6 Microwire

  • Kim, Yong-Seok;Yu, Seong-Cho;Hwang, Myung-Joo;Lee, Hee-Bok
    • Journal of Magnetics
    • /
    • 제10권3호
    • /
    • pp.122-127
    • /
    • 2005
  • New classes of LC resonators for micro magnetic sensor device were proposed and fabricated. The first type LC resonator (Type I) consists of a small piece of microwire and two cylindrical electrodes at the end of the microwire without direct contact to its ferromagnetic core. In type I resonator the ferromagnetic core of the microwire and cylindrical electrodes act as an inductor and two capacitors respectively to form a LC circuit. The second type LC resonator (Type II) consists of a solenoidal micro-inductor with a bundle of soft magnetic microwires as a core. The solenoidal micro-inductors fabricated by MEMS technique were $500\sim1,000\;\mu{m}$ in length with $10\sim20$ turns. A capacitor is connected in parallel to the micro-inductor to form a LC circuit. A tiny glass coated $CO_{83.2}B_{3.3}Si_{5.9}Mn_{7.6}$ microwire was fabricated by a glass-coated melt spinning technique. A supergiant magneto-impedance effect was found in a type I resonator as much as 400,000% by precise tuning frequency at around 518.51 MHz. In type II resonator the changes of inductance as a function of external magnetic field in micro-inductors with properly annealed microwire cores were varied as much as 370%. The phase angle between current and voltage was also strongly dependent on the magnetic field. The drastic increments of magnetoimpedance at near the resonance frequency were observed in both types of LC resonators. Accordingly, the sudden change of the phase angle, as large as $180^{\circ}C$, evidenced the occurrence of the resonance at a given external magnetic field.

Simultaneous Estimation of the Fat Fraction and R2* Via T2*-Corrected 6-Echo Dixon Volumetric Interpolated Breath-hold Examination Imaging for Osteopenia and Osteoporosis Detection: Correlations with Sex, Age, and Menopause

  • Donghyun Kim;Sung Kwan Kim;Sun Joo Lee;Hye Jung Choo;Jung Won Park;Kun Yung Kim
    • Korean Journal of Radiology
    • /
    • 제20권6호
    • /
    • pp.916-930
    • /
    • 2019
  • Objective: To investigate the relationships of T2*-corrected 6-echo Dixon volumetric interpolated breath-hold examination (VIBE) imaging-based fat fraction (FF) and R2* values with bone mineral density (BMD); determine their associations with sex, age, and menopause; and evaluate the diagnostic performance of the FF and R2* for predicting osteopenia and osteoporosis. Materials and Methods: This study included 153 subjects who had undergone magnetic resonance (MR) imaging, including MR spectroscopy (MRS) and T2*-corrected 6-echo Dixon VIBE imaging. The FF and R2* were measured at the L4 vertebra. The male and female groups were divided into two subgroups according to age or menopause. Lin's concordance and Pearson's correlation coefficients, Bland-Altman 95% limits of agreement, and the area under the curve (AUC) were calculated. Results: The correlation between the spectroscopic and 6-echo Dixon VIBE imaging-based FF values was statistically significant for both readers (pc = 0.940 [reader 1], 0.908 [reader 2]; both p < 0.001). A small measurement bias was observed for the MRS-based FF for both readers (mean difference = -0.3% [reader 1], 0.1% [reader 2]). We found a moderate negative correlation between BMD and the FF (r = -0.411 [reader 1], -0.436 [reader 2]; both p <0.001) with younger men and premenopausal women showing higher correlations. R2* and BMD were more significantly correlated in women than in men, and the highest correlation was observed in postmenopausal women (r = 0.626 [reader 1], 0.644 [reader 2]; both p < 0.001). For predicting osteopenia and osteoporosis, the FF had a higher AUC in men and R2* had a higher AUC in women. The AUC for predicting osteoporosis was highest with a combination of the FF and R2* in postmenopausal women (AUC = 0.872 [reader 1], 0.867 [reader 2]; both p < 0.001). Conclusion: The FF and R2* measured using T2*-corrected 6-echo Dixon VIBE imaging can serve as predictors of osteopenia and osteoporosis. R2* might be useful for predicting osteoporosis, especially in postmenopausal women.

고배속 CD-ROM용 비대칭형 광픽업 미세구동기의 구동특성 (Actuating Characteristics of an Asymmetric Optical Pick-up Fine Actuator of a High Speed CD-ROM)

  • 고상선;류제하;박기환;정호섭
    • 소음진동
    • /
    • 제8권2호
    • /
    • pp.346-352
    • /
    • 1998
  • This paper presents actuating characteristics of an asymmetric high-speed optical pick-up fine actuator that can be installed in a small area such as a notebook personal computer. In the asymmetric actuator four points (mass center, actuation center, supporting point of wire suspension on a bobbin, and optical axis) are not coincident so that the proposed actuator suspension reveals undesirable suspension resonance in the pitch and yaw direction. Lumped parameter dynamic model in each direction is used to investigate the driving characteristics with respect to relative location of the four points. Some of desired design directions toward reducing resonance peaks are suggested by using sensitivity information. In order to avoid undesirable resonance, at least supporting point on the obbin must be located in the middle of the mass and actuation center of the asymmetric pick-up actuator.

  • PDF

Steady-State Analysis of Reactance Oscillators having Multiple Oscillations

  • Matsuo, K.;Matsuda, T.;Nishio, Y.;Yamagami, Y.;Ushida, A.
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 ITC-CSCC -1
    • /
    • pp.203-206
    • /
    • 2000
  • In this paper, we discuss an efficient steady-state analysis of reactance oscillators having multiple oscillations. Our oscillator is consisted of the Cauer or Foster reactance sub-circuit and a negative resistor such as tunnel diode. The reactance circuit has many resonance and antiresonance points on the frequency response curve. Such a circuit having the specified resonance and anti-resonance points can be easily synthesized with the fundamental circuit theory. In this case, the multiple oscillations may occur near at the anti-resonance points. We have developed a user friendly simulator for getting the exact steady state responses using the SPICE.

  • PDF