• 제목/요약/키워드: Structure instability

검색결과 571건 처리시간 0.023초

Performances of non-dissipative structure-dependent integration methods

  • Chang, Shuenn-Yih
    • Structural Engineering and Mechanics
    • /
    • 제65권1호
    • /
    • pp.91-98
    • /
    • 2018
  • Three structure-dependent integration methods with no numerical dissipation have been successfully developed for time integration. Although these three integration methods generally have the same numerical properties, such as unconditional stability, second-order accuracy, explicit formulation, no overshoot and no numerical damping, there still exist some different numerical properties. It is found that TLM can only have unconditional stability for linear elastic and stiffness softening systems for zero viscous damping while for nonzero viscous damping it only has unconditional stability for linear elastic systems. Whereas, both CEM and CRM can have unconditional stability for linear elastic and stiffness softening systems for both zero and nonzero viscous damping. However, the most significantly different property among the three integration methods is a weak instability. In fact, both CRM and TLM have a weak instability, which will lead to an adverse overshoot or even a numerical instability in the high frequency responses to nonzero initial conditions. Whereas, CEM possesses no such an adverse weak instability. As a result, the performance of CEM is much better than for CRM and TLM. Notice that a weak instability property of CRM and TLM might severely limit its practical applications.

쉘형 스페이스 프레임 구조물의 하중 및 경계조건에 따른 불안정 거동에 관한 연구 (A Study on the Unstable behavior according to Lode and boundary condition of shelled space frame structure)

  • 김남석;손수덕;김승덕
    • 한국공간구조학회:학술대회논문집
    • /
    • 한국공간구조학회 2008년도 춘계 학술발표회 논문집
    • /
    • pp.80-85
    • /
    • 2008
  • 본 논문에서는 쉘형 스페이스 프레임 구조물의 구조 불안정 특성을 조사한다. 대공간 구조물은 대경간을 가볍게 만들기 위해 두께비를 얇게 만들어야 하므로, 구조설계시 구조불안정 검토가 중요하다. 쉘형 구조물의 구조불안정은 다양한 조건에 따라 민감하게 반응하며, 이는 대변형을 수반하는 비선형 문제에 귀착하게 된다. 따라서 본 연구에서는 기하학적 비선형을 고려한 수치해석 기법을 통하여 쉘형 스페이스 프레임 구조물의 하중 및 경계조건에 따른 불안정 거동을 비교하고, 불안정 현상에 미치는 영향을 파악하여 기초적인 붕괴 메커니즘을 규명한다.

  • PDF

Aerodynamic stability analysis of geometrically nonlinear orthotropic membrane structure with hyperbolic paraboloid in sag direction

  • Xu, Yun-ping;Zheng, Zhou-lian;Liu, Chang-jiang;Wu, Kui;Song, Wei-ju
    • Wind and Structures
    • /
    • 제26권6호
    • /
    • pp.355-367
    • /
    • 2018
  • This paper studies the aerodynamic stability of a tensioned, geometrically nonlinear orthotropic membrane structure with hyperbolic paraboloid in sag direction. Considering flow separation, the wind field around membrane structure is simulated as the superposition of a uniform flow and a continuous vortex layer. By the potential flow theory in fluid mechanics and the thin airfoil theory in aerodynamics, aerodynamic pressure acting on membrane surface can be determined. And based on the large amplitude theory of membrane and D'Alembert's principle, interaction governing equations of wind-structure are established. Then, under the circumstance of single-mode response, the Bubnov-Galerkin approximate method is applied to transform the complicated interaction governing equations into a system of second-order nonlinear differential equation with constant coefficients. Through judging the frequency characteristic of the system characteristic equation, the critical velocity of divergence instability is determined. Different parameter analysis shows that the orthotropy, geometrical nonlinearity and scantling of structure is significant for preventing destructive aerodynamic instability in membrane structures. Compared to the model without considering flow separation, it's basically consistent about the divergence instability regularities in the flow separation model.

3 성분 혼합연료의 분무특성 해명 (Analysis of Spray Characteristic for 3-Component Mixed Fuel)

  • 명광재
    • 대한기계학회논문집B
    • /
    • 제33권8호
    • /
    • pp.589-595
    • /
    • 2009
  • The instability wave formed near nozzle region grows to vortex with large scale in downstream region of spray. It plays an important role in the fuel-air mixing, combustion process and engine exhaust emissions in direct injection diesel engine. The objective of this study is to analyze effect of variant parameters (injection pressure, ambient gas density, etc.) and fuel properties on spray instability near nozzle region. Spray structure near nozzle region was investigated using a magnification photograph. A pulsed Nd-YAG laser was used as a light source, and image was taken by CCD camera. The following conclusions are drawn from this experimental analysis. In low ambient density, the effect of fuel properties on spray instability near nozzle region is dominant. In high ambient density, the effect of ambient gas on spray instability near nozzle region is dominant. High jet velocity has strong influence on spray instability.

접선 강성방정식과 비선형 강성방정식을 이용한 비선형 해의 정확성 비교에 관한 연구 (A study on the Accurate Comparison of Nonlinear Solution Which Used Tangent Stiffness Equation and Nonlinear Stiffness Equation)

  • 김승덕;김남석
    • 한국공간구조학회논문집
    • /
    • 제10권2호
    • /
    • pp.95-103
    • /
    • 2010
  • 본 논문에서는 비선형 강성방정식의 정확성 향상에 관해 연구한다. 대공간 구조물은 대경간을 가볍게 만들기 위해 두께비를 얇게 만들어야 하므로, 구조설계시 구조불안정 검토가 중요하다. 쉘형 구조물의 구조불안정은 초기 조건에 매우 민감하게 반응하며, 이는 대변형을 수반하는 비선형 문제에 귀착하게 된다. 따라서 구조불안정을 정확히 알아보기 위해 비선형 강성방정식의 정확성이 향상 되어야 한다. 본 연구에서는 스페이스 트러스를 해석 모델로 하며 접선 강성방정식과 비선형 강성방정식의 두 이론을 프로그램으로 작성하여 비선형 해석을 수행한다. 두 이론의 해석 결과를 비교 고찰하여 비선형 강성방정식의 정확성 및 수렴성 향상에 대해 검토 한다.

  • PDF

케이블 돔 구조물의 불안정 현상에 대한 브레이싱 보강 효과 (Effects by Bracing Reinforcement on the Instability Phenomenon of Cable Domes)

  • 김승덕;김형석;백인성
    • 한국공간구조학회논문집
    • /
    • 제1권2호
    • /
    • pp.75-83
    • /
    • 2001
  • The characteristics of structural behavior for a cable dome shows a strong nonlinearity and very sensitive by the initial imperfection. The instability phenomenon of Geiger-type cable dome structure is generated due to the in-plane twisting near the critical load level. In this study, therefore, the effect of bracing reinforcement resisting to the in-plane twisting is investigated for the Geiger-type model reinforced by bracing. The effect of initial imperfection is also studied because the structural instability phenomenon of shell-like structure is very sensitive according to the initial condition.

  • PDF

Advanced aerostatic stability analysis of suspension bridges

  • Xiao, Ru-Cheng;Cheng, Jin
    • Wind and Structures
    • /
    • 제7권1호
    • /
    • pp.55-70
    • /
    • 2004
  • Aerostatic instability of a suspension bridge may suddenly appears when the deformed shape of the structure produces an increase in the value of the three components of displacement-dependent wind loads distributed in the structure. This paper investigates the aerostatic stability of suspension bridges using an advanced nonlinear method based on the concept of limit point instability. Particular attention is devoted to aerostatic stability analysis of symmetrical suspension bridges. A long-span symmetrical suspension bridge (Hu Men Bridge) with a main span of 888 m is chosen for analysis. It is found that the initial configuration (symmetry or asymmetry) may affect the instability configuration of structure. A finite element software for the nonlinear aerostatic stability analysis of cable-supported bridges (NASAB) is presented and discussed. The aerostatic failure mechanism of suspension bridges is also explained by tracing aerostatic instability path.

Geiger형 케이블 돔 구조물의 외력에 따른 동적 불안정 특성 비교분석 (A Comparative Analysis of Dynamic Instability Characteristic of Geiger-Typed Cable Dome Structures by Load Condition)

  • 김승덕;신인아
    • 한국공간구조학회논문집
    • /
    • 제14권1호
    • /
    • pp.85-91
    • /
    • 2014
  • The purpose of this paper is to study comparative of dynamic instability characteristic of Geiger-typed cable dome structures by load condition, which is well-known among the cable dome structures that are the lightweight hybrid structure using compression and tension element continuously. Dynamic buckling process in the phase plane is very important thing for understanding why unstable phenomena are sensitively originated in nonlinear dynamic by various initial conditions. But there is no paper for the dynamic instability of hybrid cable dome by Sinusoidal Excitations, many papers which deal with the dynamic instability for shell-structures under the step load have been published. As a result of Geiger-typed cable dome, which shows chaotic behavior in dynamic nonlinear analysis with initial imperfection.

모형 가스터빈 연소기내 연소불안정성에 대한 실험적 연구 (An Experimental Study on Combustion Instability Mechanism in a Dump Gas Turbine Combustor)

  • 이연주;이종호;전충환;장영준
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.853-858
    • /
    • 2001
  • The knowledge of flame structure is essential for control of combustion instability phenomena. Some results of an experimental study on mechanism of naturally occurring combustion oscillations with a single dominant frequency are presented. Tests were conducted in a laboratory-scale dump combustor at atmospheric pressure. Sound level meter was used to track the pressure wave inside the combustor. The observed instability was a longitudinal mode with a frequency of $\sim341.8Hz$. Instability map was obtained at the condition of inlet temperature of $360^{\circ}C$, mean velocities of $8.5\sim10.8m/s$ and well premixed mixture. It showed that combustion instability was susceptible to occur in the lean conditions. In this study, unstable flame was observed from stoichiometric to 0.7 in overall equivalence ratio. At selected unstable conditions, phase-resolved OH chemiluminescence images were captured to investigate flame structure with various mean velocities. As mean velocity is increased, the flame grows and global heat release was changed. Due to these effects, combustion instability can be maintained at more lean air-fuel ratio. Also, these results give an insight to the controlling mechanism for an increasing heat release at maximum pressure.

  • PDF

Dynamic analysis of the agglomerated SiO2 nanoparticles-reinforced by concrete blocks with close angled discontinues subjected to blast load

  • Amnieh, Hassan Bakhshandeh;Zamzam, Mohammad Saber
    • Structural Engineering and Mechanics
    • /
    • 제65권1호
    • /
    • pp.121-128
    • /
    • 2018
  • Three structure-dependent integration methods with no numerical dissipation have been successfully developed for time integration. Although these three integration methods generally have the same numerical properties, such as unconditional stability, second-order accuracy, explicit formulation, no overshoot and no numerical damping, there still exist some different numerical properties. It is found that TLM can only have unconditional stability for linear elastic and stiffness softening systems for zero viscous damping while for nonzero viscous damping it only has unconditional stability for linear elastic systems. Whereas, both CEM and CRM can have unconditional stability for linear elastic and stiffness softening systems for both zero and nonzero viscous damping. However, the most significantly different property among the three integration methods is a weak instability. In fact, both CRM and TLM have a weak instability, which will lead to an adverse overshoot or even a numerical instability in the high frequency responses to nonzero initial conditions. Whereas, CEM possesses no such an adverse weak instability. As a result, the performance of CEM is much better than for CRM and TLM. Notice that a weak instability property of CRM and TLM might severely limit its practical applications.