• 제목/요약/키워드: Structure Flaw

검색결과 52건 처리시간 0.029초

구조체 균열 하자 저감을 위한 균열 저감형 콘크리트의 기초적 연구 (A Basic Studies of the Concrete Crack Reduction-type Structure for Crack Reduction Flaw)

  • 박희곤;이지환;박기홍
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 춘계 학술논문 발표대회
    • /
    • pp.197-198
    • /
    • 2016
  • The root cause of the crack flaw occurred in construction. This crack is represented by a construction flaw occurs in the concrete structure. Therefore, we introduce the basic properties for the type of concrete to crack reduction measures to minimize the causes flaw this paper.

  • PDF

ECA 기법을 이용한 해양구조물의 결함 평가 (Flaw Assessment on an Offshore Structure using Engineering Criticality Analysis)

  • 강범준;김유일;류철호;기혁근;박성건;오영태
    • 대한조선학회논문집
    • /
    • 제52권6호
    • /
    • pp.435-443
    • /
    • 2015
  • Offshore structure may be considerably vulnerable to fatigue failure while initial flaw propagates under cyclic loading, so crack propagation analysis/fracture/yield assessments about initial flaw detected by NDT are necessarily required. In this paper, case studies have been conducted by flaw assessment program using engineering criticality analysis (ECA) approach. Variables such as flaw geometry, flaw size, structure geometry, dynamic stress, static stress, toughness, crack growth rate, stress concentration factor (SCF) affected by weld are considered as analysis conditions. As a result, the safety of structure was examined during fatigue loading life. Also, critical initial flaw size was calculated by sensitivity module in the developed program. The flaw assessments analysis using ECA approach can be very useful in offshore industries owing to the increasing demand on the engineering criticality analysis of potential initial flaws.

피로하중을 받는 구조물의 결함분포에 대한 확률론적 해석 (Probabilistic Analysis of Flaw Distribution on Structure Under Cyclic Load)

  • 곽상록;최영환;김효정
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.604-609
    • /
    • 2003
  • Flaw geometries, applied stress, and material properties are major input variables for the fracture mechanics analysis. Probabilistic approach can be applied for the consideration of uncertainties within these input variables. But probabilistic analysis requires many assumptions due to the lack of initial flaw distributions data. In this study correlations are examined between initial flaw distributions and in-service flaw distributions on structures under cyclic load. For the analysis, LEFM theories and Monte Carlo simulation are applied. Result shows that in-service flaw distributions are determined by initial flaw distributions rather than fatigue crack growth rate. So initial flaw distribution can be derived from in-service flaw distributions.

  • PDF

충격탄성파법을 이용한 콘크리트 내부의 결함탐상 기술개발 (The Development of Flaw Detection in Concrete by the Impact-Echo Testing Method)

  • 박선균;임창덕
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1991년도 봄 학술발표회 논문집
    • /
    • pp.105-110
    • /
    • 1991
  • The conventional high-frequency testing method is difficult to detect flaw in concrete because the high frequency stress wave is strongly attenuated due to the large grain size and heterogeneous structure. For restoration of this problem, we develop the stu요 of flaw detection in large concrete block containing various artificial flaws by low frequency spectrum anlysis of impact-echo waveforms. This impact-echo testing method is possible to determine the flaw size, shape and location in large concrete block even if required some attention in case of containing reinforcing steel bar.

  • PDF

회전익 항공기용 주 로터 작동기에 대한 손상허용 평가 연구 (A Study on Flaw Tolerance Evaluation of a Main Rotor Actuator for Rotorcraft)

  • 박주원;정정래
    • 항공우주시스템공학회지
    • /
    • 제14권spc호
    • /
    • pp.1-6
    • /
    • 2020
  • 미국 연방항공규정(FAR) §29.571 Amendment 55에서 다루고 있는 손상허용 평가 내용은 2012년에 개념 정립이 되었다. 최근 정립된 개념임에 따라 손상허용 평가 개념을 도입하여 입증 절차를 수행한 이력이 많지 않다. 본 논문은 회전익 항공기에서 주요 구조 요소(PSE; Principal Structure Element)로 분류된 주 로터 작동기 개발품을 FAR §29.571 요건의 손상허용 평가를 바탕으로 인증을 위해 수행한 일련의 과정 및 평가 방법들을 소개하고자 한다. 주 로터 작동기는 초기결함을 생성한 후 설계 목표수명의 2배수에 해당하는 손상허용 시험을 수행하였다. 이를 바탕으로 회전익 항공기 주 로터 작동기는 충분한 손상허용능력을 확보하고 있음을 입증하였다.

STS304 스테인리스강 용접부 결함평가에 대한 Pulse-echo법과 TOFD법의 비교연구 (A Comparative Study of Pulse-echo Method and TOFD Method for the Defect in the Welding Joint of the STS304 Stainless Steel)

  • 길두송;최원두
    • 동력기계공학회지
    • /
    • 제6권4호
    • /
    • pp.68-72
    • /
    • 2002
  • For the evaluation of a flaw in a welded stainless steel by the Time of Flight Diffraction(TOFD) Method, we have made the reference specimen for experimentation. As a result, we could analyze a specific character and the inner state of the structure in a welded stainless steel and we came to the conclusion as followed. (1) For analyze the structure state of a section in a welded stainless steel through the optical microscope, we could have analyzed the generated shape and the location of a flaw and the inner parts of the structure state through the microscope of eighty magnification and two hundred magnification about the soundness, the heat affected zone(HAZ) and the welded part. (2) Through the comparison with the shape and the size of a flaw in the welded part about the conventional ultrasonic test and the TOFD Method, we could make an observation the special character of the TOFD Method and principles. (3) We analyzed and collected the merit of the TOFD Method on the basis of the experimental result by the shape and the size of a flaw in the inner welded parts. So, we made up a base that we could use as a basic data for a similar flaw like that. Through the study as mentioned above, we could make an observation the flaw detective method and principles used in the TOFD Method.

  • PDF

Yield and Fracture of Paper

  • Park, Jong-moon;James L. Thorpe
    • 펄프종이기술
    • /
    • 제31권5호
    • /
    • pp.57-72
    • /
    • 1999
  • Traditional theories of the tensile failure of paper have assumed that uniform strain progresses throughout the sheet until an imperfection within the structure causes a catastrophic break. The resistance to tensile elongation is assumed to be elastic , at first, throughout the structure, followed by an overall plastic yield. However, linear image strain analysis (LISA) has demonstrated that the yield in tensile loading of paper is quite non-uniform throughout the structure, Traditional theories have failed to define the flaws that trigger catastrophic failure. It was assumed that a shive or perhaps a low basis weight area filled that role. Studies of the fracture mechanics of paper have typically utilized a well-defined flaw around which yield and failure could be examined . The flaw was a simple razor cut normal to the direction of tensile loading. Such testing is labeled mode I analysis. The included fla in the paper was always normal to the tensile loading direction, never at another orientation . However, shives or low basis weight zones are likely to be at random angular orientations in the sheet. The effects of angular flaws within the tensile test were examined. The strain energy density theory and experimental work demonstrate the change in crack propagation from mode I to mode IIas the initial flaw angle of crack propagation as a function of the initial flaw angle is predicted and experimentally demonstrated.

  • PDF

파괴확률 산정을 위한 검측 데이터의 확률적 업데이트 (Updating Inspection Data to Estimate Probability of Failure)

  • 정태영;박흥민;이학;공정식
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2007년도 정기 학술대회 논문집
    • /
    • pp.645-650
    • /
    • 2007
  • According to most studies, assessment of aging structure is trend to detect flaw size by sensor than using existing subjective evaluation by expert for objective evaluation. But Uncertainties existing in the sensor make difference between measured flaw size and actual flaw size, In this paper, Probability of Detection(POD) have been used to quantify the uncertainties and POD is updated by relationship measured flaw size and actual flaw size (Heasler, 1990), also we proposed probabilistic updating approach method to improve measurement accuracy(the difference of measured PDF and actual PDF) by using updated POD.

  • PDF

충격반향시험에 의한 콘크리트 터널 라이닝 내부결함 및 두께 조사 (Inspection for Internal Flaw and Thickness of Concrete Tunnel Lining Using Impact Echo Test)

  • 김영근;이용호;정한중
    • 터널과지하공간
    • /
    • 제7권3호
    • /
    • pp.230-237
    • /
    • 1997
  • As concrete structure is getting old and decrepit, its inspection and diagnosis is getting important. Therefore, it is necessary to estimate the soundness of structure using non-destructive tests for effective repairs and maintenances. But, applications of non-destructive tests in tunnel have been used restrictively, due to accessibility only from one side in tunnel lining and presence of tunnel installations. Recently, the various non-destructive techniques have been studied. Especially, ground penetrating radar(GPR) and impact echo (IE) methods have been researched for tunnel inspection. In this study, the applicability of impact echo test in tunnel lining inspection has been investigated. This paper described the tunnel inspection for lining thickness and internal flaw using impact echo tests. Model tests were carried out using impact echo test systems on two concrete models, Model I is measuring for lining thickness, Model II is detecting for internal flaw. Also, the test were applied for lining inspections in a tunnel constructed by NATM. From the results of impact echo tests, we have concluded that impact echo test is a very useful and effective technique for inspecting the concrete tunnel linings.

  • PDF

Application of the Leak Before Break(LBB) Concept to a Heat Exchanger in a Nuclear Power Plant

  • Kwon, Jae-Do;Lee, Choon-Yeol;Lee, Yong-Son;Sul, Il-Chan
    • Journal of Mechanical Science and Technology
    • /
    • 제15권1호
    • /
    • pp.10-20
    • /
    • 2001
  • The leak before break(LBB) concept is difficult to apply to a structure with a thin tube that is immersed in a water environment. A heat exchanger in a nuclear power plant is such a structure. The present paper addresses an application of the LBB concept to a heat exchanger in a nuclear power plant. The minimum leaked coolant amount(approximately 37.9 liters) containing the radioactive material which can activate the radiation detector device installed in near the heat exchanger is assumed. A postulated initial flaw size that can not grow to a critical flaw size within the time period to activate the radiation detector is justified. In this case, the radiation detector can activate the warning signal caused by coolant leakage from initially postulated flaws of the heat exchanger. The nuclear plant can safely shutdown when this occurs. Since the postulated initial flaw size can not grow to the critical flaw size, the structural integrity of the heat exchanger is not impeded. Particularly the informational scenario presented in this paper discusses an actual nuclear plant.

  • PDF