• Title/Summary/Keyword: Structural safety standard

Search Result 293, Processing Time 0.026 seconds

A Study on Double Bottom Structural Criterion of Oil Tanker under DWT 500 (재화중량 500톤 미만 유조선의 이중저구조기준 연구)

  • Lee, Sang-Gab;Yoon, Yeo-Hoon;Bae, Jun-Yong
    • Journal of Korea Ship Safrty Technology Authority
    • /
    • s.23
    • /
    • pp.2-13
    • /
    • 2007
  • With the effectuation of the amendment of MARPOL 73/78 on 5 April 2005, enforcement regulations of Marine Pollution Prevention Act were revised in domestic on 12 March 2005 that double hull structure was required to the small single bottom oil tankers under DWT(deadweight tonnage) 500 ton for the protection of the marine pollution casualties. The objective of this study is to develop the double bottom structure of small oil tanker under DWT 500 ton with superior crashworthiness and to establish its suitable standard to double bottom structure. The promoting strategy of this R&D is classified into the crashworthy structural analysis of small oil tankers using LS/DYNA3D code and the examination of their damage stabilities according to tonnage. It could be thought that the desirable inner bottom height should be above the B/7.5 and its minimum height 0.65m for the domestic small oil tanker under DWT 500ton.

  • PDF

A Study on the Fire Risk of Urban type housing constructed by pilotis structures, -In the case of Uijeongbu fire- (필로티구조 도시형생활주택의 화재위험성에 관한 연구 -의정부사례를 바탕으로-)

  • Hwang, Eu-Cheong;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.50-51
    • /
    • 2017
  • The Urban-type building is an building that it relaxed the construction standard and subsidiary facility standard. The most of the urban-type buildings are pilotis, the main case of representing these building's fire risk is the Uijeongbu fire this study investigated to piloti urban type housing risk on the basis of Uijeongbu fire, and we checked structural problem that unable to escape from the rooftop inside the piloti. also, there was confirmed limit to the evacuation of the occupants because the smoke was rapidly transferred to the top layer through inside the electric duct. and when we analyzed smoke flow use of Fire simulation, it was confirmed Available Safety Egress Time that is four minutes of CO.

  • PDF

Performance-based seismic design of reinforced concrete ductile buildings subjected to large energy demands

  • Teran-Gilmore, Amador;Sanchez-Badillo, Alberto;Espinosa-Johnson, Marco
    • Earthquakes and Structures
    • /
    • v.1 no.1
    • /
    • pp.69-91
    • /
    • 2010
  • Current seismic design codes do not contemplate explicitly some variables that are relevant for the design of structures subjected to ground motions exhibiting large energy content. Particularly, the lack of explicit consideration of the cumulative plastic demands and of the degradation of the hysteretic cycle may result in a significant underestimation of the lateral strength of reinforced concrete structures built on soft soils. This paper introduces and illustrates the use of a numerical performance-based methodology for the predesign of standard-occupation reinforced concrete ductile structures. The methodology takes into account two limit states, the performance of the non-structural system, and in the case of the life safety limit state, the effect of cumulative plastic demands and of the degradation of the hysteretic cycle on the assessment of structural performance.

Optimum Design of Reinforced Concrete frames Considering Serviceability (사용성을 고려한 RC뼈대 구조물의 최적설계)

  • 김기대;박성규
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2002.10a
    • /
    • pp.279-286
    • /
    • 2002
  • This study is concerned wiか the practical optimum design of concrete framed structures considering serviceability - deflection, crack, fatigue. The optimizing problems of framed structure are formulated with the objective function and the constraints which take the section properties as the design variables. The objective functions are formulated as the total cost of the structures and the constraints are derived by using the criteria with respect to safety and serviceability based on the part of concrete bridge in the Korea standard code of road bridge. The SLP method is introduced to solve the formulated nonlinear programming problems in this study and tested out through the numerical examples. This developed optimizing algorithm is tested out and examined through the numerical examples for the practical use of design on the concrete framed structures. And their results are compared and analyzed to examine the possibility of optimization, the applicability and the convergency of this algorithm.

  • PDF

A study of the triangular cross section type greenhouse using fluid-structure interaction (유체-구조 연성해석을 통한 삼각단면 형상의 비닐하우스에 관한 연구)

  • Lee, GyuHan;Kim, Jeong Jae;Kim, Jeongju;Lee, Sang Joon;Ha, Hojin;Kang, TaeWon
    • Journal of the Korean Society of Visualization
    • /
    • v.17 no.2
    • /
    • pp.17-24
    • /
    • 2019
  • The purpose of this study is to study the fluid-dynamic and structural characteristics of the conventional greenhouse and to find possible improvement on the current greenhouse. The greenhouse is required to have enough rigidity of the structure while the installation and reinforcement should be as easy as possible. In this study, the structural stability to the snow load was tested through the computational structure analysis based on the building structure standard, and the wind load was computed by computational fluid-structure interaction analysis. The current analysis can be used as a reference data for a new greenhouse and it will be economically viable by reducing installation and maintenance costs.

Shape Extraction of Stiffeners of H-beam using Topologically Structural Optimization (위상최적설계를 이용한 H형강 부재의 스티프너 형상탐색)

  • Jung, Wonsik;Banh, Thien Thanh;Lee, Dongkyu
    • Journal of Korean Association for Spatial Structures
    • /
    • v.23 no.1
    • /
    • pp.15-23
    • /
    • 2023
  • In this work, we deal with the feasibility of structural topology optimization for beam designs using retrofits that optimally allocates the reinforcement to the web under the condition that designers set bolt regions for H-beams of different dimensions. Mean compliance or minimal strain energy is considered for the optimization. Volume fraction is given to the design space to assign appropriate steel material quantities. The purpose of this study is to evaluate optimal shapes of stiffeners with the maximum rigidity that improves the axial and shear performance of the H-beam and to satisfy a given safety design standard of H-beam and stiffeners in case arbitrary load effect and resistances. Finally, the effectiveness of stiffness-based topology optimization on stiffeners is verified with several practical applicable examples.

Development of Wide Prestressed Concrete Sleeper for Asphalt Concrete Track (아스팔트 콘크리트 궤도용 광폭 PSC침목 개발)

  • Bae, Young-Hoon;Lee, Seong-Hyeok;Kim, Eung-Rok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.2
    • /
    • pp.34-42
    • /
    • 2018
  • In order to minimize the deformation of asphalt concrete track(ACT) and ensure the structural safety, a wide type concrete sleeper is necessary to distribute vehicle loading and reduce the exposure of the asphalt roadbed. In this research, the wide prestressed concrete(PSC) sleeper for ACT was developed through the shape design and the structural safety was reviewed using finite element analysis. Furthermore, static test, dynamic test and fatigue test were carried out according to EN13230-2 to verify the design appropriateness of the wide PSC sleepers for ACT. The performance test showed that the developed wide PSC sleeper for ACT meets all the performance requirements by European standard.

A Study on the Mechanical Properties of SM490A by FCAW Welding Attitude (SM490A의 FCAW 용접 자세별 형상에 관한 기계적 특성 연구)

  • Lim, Kwang Mook;Lee, Sung Ill
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.6
    • /
    • pp.7-12
    • /
    • 2019
  • Flux Cored Arc Welding (FCAW), which has been widely used in many industries, was developed in the 1950s to supplement shortcomings of the Shielded Metal Arc Welding (SMAW). FCAW has an advantage in that it can weld regardless of postures and give good quality results in the filed with many different working conditions. In this study, SM490A (rolled steel for welding structural purpose) with different thicknesses (L:25T+R:30T) were welded using FCAW. Then the mechanical properties (tension test, bending test, hardness test, impact test and macro test) were analyzed and the following conclusions were drawn. In the tensile test, it exceeds the KS standard tensile strength range (400~510) in all welding positions, which means there is a problem in the tensile force transmission performance. In the bending test, it was found that most of the specimens did not exhibit surface rupture or other defects during bending test and they exhibit sufficient toughness even after plastic deformation. In the hardness test, all the results were lower than the standard value of 350 Hv of KS B 0893, which means they have good hardness. In the impact test, all results were larger than the KS reference value of 27J. In the macro test, they showed uniform structure state by the shape of the weld, and there was risk of lamination because no internal defects, bubbles, or impurities were found on the surface of the weld.

An Ergonomic Study of School Environment and Desks/chairs in Incheon Metropolitan Area (인천지역 초 · 중 · 고등학교의 학교환경 및 책걸상에 대한 인간공학적 연구)

  • Kim, Cheol-Hong;Mun, Myeong-Guk;Jang, An-Seok
    • Journal of the Ergonomics Society of Korea
    • /
    • v.25 no.2
    • /
    • pp.173-180
    • /
    • 2006
  • An ergonomic study of school environment and school desks and chairs was conducted in Incheon metropolitan area. Total of 1,145 students from 11 schools participated in questionnaire survey and ergonomic evaluation of school desks and chairs was performed to study structural appropriateness and usability. Results of the study revealed that overall levels of school environment in terms of noise and dust density in the air were higher than safety standard. Desks and chairs were not properly designed with consideration of student's anthropometric characteristics. Prompt improvement of school environment and re-designing of school furniture are required in order to prevent reduced performance in study and physical disorders such as musculoskeletal disorders.

Evaluation of Total Serviceable Life of Bogie Frame of Electric Multiple Unit by Dynamic Strain Measurement (실동응력 측정을 통한 전동차 대차프레임의 내구수명 평가)

  • Kim, Seung-Sub;Han, Seong-Uk;Park, Geun-Soo;Woo, Kwan-Je
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.277-282
    • /
    • 2011
  • Bogie frame is typical safety part of railway vehicle. Total serviceable life of bogie frame will be evaluated by Cumulative Damage Approach Method that is defined by dynamic strain measurement during revenue service under the actual track conditions. As a result of the standardization process developed in British Standard Institution, BS 7608 defines for fatigue design and test method of steel structure by fatigue test results over the long period. This paper evaluates the total serviceable life applying BS 7608 for the bogie frame of Electric Multiple Unit to verify structural safety of the bogie frame.

  • PDF