• Title/Summary/Keyword: Structural Vibration Criteria

Search Result 102, Processing Time 0.026 seconds

A system of multiple controllers for attenuating the dynamic response of multimode floor structures to human walking

  • Battista, Ronaldo C.;Varela, Wendell D.
    • Smart Structures and Systems
    • /
    • v.23 no.5
    • /
    • pp.467-478
    • /
    • 2019
  • Composite floor structures formed by continuous slab panels may be susceptible to excessive vibrations, even when properly designed in terms of ultimate limit state criteria. This is due to the inherent vibration characteristics of continuous floor slabs composed by precast orthotropic reinforced concrete panels supported by steel beams. These floor structures display close spaced multimode vibration frequencies and this dynamic characteristic results in a non-trivial vibration problem. Structural stiffening and/or insertion of struts between floors are the usual tentative solution applied to existing vibrating floor structures. Such structural alterations are in general expensive and unsuitable. In this paper, this vibration problem is analyzed on the basis of results obtained from experimental measurements in typical composite floors and their theoretical counterpart obtained with computational modeling simulations. A passive control system composed by multiple synchronized dynamic attenuators (MSDA) was designed and installed in these floor structures and its efficiency was evaluated both experimentally and through numerical simulations. The results obtained from experimental tests of the continuous slab panels under human walking dynamic action proved the effectiveness of this control system in reducing vibrations amplitudes.

Development of finite element model updating program (유한요소 모델 개선 프로그램 개발)

  • Wang, S.M.;Ko, C.S.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1633-1640
    • /
    • 2000
  • The finite element analysis (FEA) is widely used in modem structural dynamics because the performance of structure can be predicted in early stage. However, due to the difficult in determination of various uncertain parameters, it is not be easy to obtain a reliable finite element model. To overcome these difficulties, updating program of FE model is developed by consisting of pretest, correlation and updating. In correlation, it calculates modal assurance criteria, cross orthogonality, mixed orthogonality and coordinate modal assurance criteria. For the model updating, the continuum sensitivity analysis and design optimization tool (DOT) are used. The SENSUP program is developed for model updating to obtain physical parameter sensitivity. The developed program is applied to practical examples such as the base plate of HDD, BLDC spindle motor, and upper housing of induction motor. And the sensor placement for the square plate is compared using several methods.

  • PDF

Estimation of Stiffness Limit for Railway Bridge Vibration Serviceability (진동사용성을 고려한 철도교량구조물의 강성한계 분석)

  • Jeon, Bub-Gyu;Kim, Nam-Sik;Kim, Sung-Il
    • Journal of the Korean Society for Railway
    • /
    • v.11 no.5
    • /
    • pp.489-498
    • /
    • 2008
  • In general, deflection limit criteria of bridge design specifications have been considered based on static serviceability and structural stability. Dynamic serviceability induced from bridge vibration actually has not been included in the criteria. Thus, it is necessary for deflection limit to be considered in order to check dynamic service- ability on bridge vibration. In this study, The allowable displacement of Korea Railway Bridge Design Specifications is compared to the frequency domain comfort limit and analyzed france code and japanese code. Korea Railway Bridge Design Specifications is regulated based on the train speed. Such is because the vibration time duration is partly considered. but this criteria is not satisfied with comfort limit. and, it is estimated to be capable to provide deflection limit considering dynamic serviceability. In order to evaluate the dynamic serviceability of various types of railway bridges in current public were selected and their dynamic signals were measured. and the result of the bridge-train interaction analysis according to the changes in bridge stiffness was compared to the comfort limit to suggest the stiff-ness limit to the dynamic serviceability, which should conveniently be applied at the field.

Structural Vibration Control Using Semiactive Tuned Mass Damper (건물의 내진성능을 향상시키기 위한 반능동 동조질량감쇠 시스템)

  • Moon, Yeong-Jong;Ji, Han-Rok;Jung, Hyung-Jo;Lee, In-Won
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2006.03a
    • /
    • pp.645-650
    • /
    • 2006
  • This paper presents the results of a study to verify the sufficient control performance of semiactive tuned mass damper and to identify suitable control methods for semiactive tuned mass damper in structural vibration control. In this study, four control algorithms are considered: on-off displacement based groundhook, on-off velocity based groundhook, clipped optimal and maximum energy dissipation algorithm. For semiactive tuned mass damper, MR damper is considered as a controllable damping device and the command voltage is calculated by the control algorithms. Each of the control theory is applied to the three story shear building excited by three earthquakes. The performance of each algorithm is compared with that of conventional tuned mass damper system using evaluation criteria. The simulation results indicate that semiactive tuned mass damper has control efficiency. Among the control algorithms, on-off displacement based control theory shows the best efficacy and robustness.

  • PDF

Design of a Dynamic Absorber for the Large-Size Pressure Vessel of the Petrochemical Plant (석유화학 플랜트의 대형 압력용기에 대한 동흡진기의 설계)

  • Kim, Min-Chul;Lee, Boo-Youn;Kim, Won-Jin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.743-749
    • /
    • 2005
  • In this work, two dynamic absorbers are introduced and designed to reduce the vibration of the large-size pressure vessel of a reactor for a petrochemical plant. The vibration modes and harmonic responses of the vessel are firstly analyzed by the finite element method. On the basis of the analyzed results, two dynamic absorbers are designed by a simple design theory. Furthermore, an optimization process is executed and an optimal design of the dynamic absorber is obtained to improve performance and structural safety of the vessel. As a result, the maximum displacement and stress of the vessel is decreased about 85% and 65% respectively, the design criteria being satisfied.

  • PDF

Optimal Design of a Dynamic Absorber for the Large-size Pressure Vessel of the Petrochemical Plant (석유화학 플랜트의 대형 압력용기에 대한 동흡진기의 최적설계)

  • Kim, Min-Chul;Lee, Boo-Youn;Kim, Won-Jin
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.5 s.98
    • /
    • pp.612-619
    • /
    • 2005
  • In this work. two dynamic absorbers are introduced and designed to reduce the vibration of the large-size pressure vessel of a reactor for a petrochemical plant. The vibration modes and harmonic responses of the vessel are firstly analyzed by the finite element method. On the basis of the analyzed results, two dynamic absorbers are designed by a simple design theory. Furthermore, an optimization process is executed and an optimal design of the dynamic absorber is obtained to improve performance and structural safety of the vessel. As a result, the maximum displacement and stress of the vessel is decreased about $85\%$ and $65\%$ respectively, the design criteria being satisfied.

Vibration Characteristics of a Dummy Fuel Rod Supported by Spacer Grids (지지격자로 지지된 모의 연료봉의 진동특성)

  • Choi, Myoung-Hwan;Kang, Heung-Seok;Yoon, Kyung-Ho;Kim, Hyung-Kyu;Song, Kee-Nam
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.3
    • /
    • pp.424-431
    • /
    • 2003
  • The spacer grid is one of the main structural components in the fuel assembly, which supports the fuel rods and maintains coolable geometry from an external load. A vibration test and a finite element analysis using ABAQUS on a dummy fuel rod continuously supported by Optimized H type(OHT) and New Doublet (ND) spacer grids arc performed to obtain the vibration characteristics such as natural frequencies and mode shapes an(1 to verify a finite element model. The results from the test and the finite element analysis are compared by modal assurance criteria (MAC) values. It is resulted that MACs for the first, the third and the fifth mode shapes are relatively good as compared with those of the second an(1 fourth ones. The natural frequency differences between two methods as well as the mode comparison results for the rod with OHT spacer grid are better than those with ND spacer grid. It is judged that the FE model for the ND spacer grid spring should be modified to consider the long contact length which actually happen when the spring supports the rod.

An Experimental Study on Structural Safety Assesment of Wet Type Floor Heating System with Insulation (완충재 적용에 따른 습식온돌의 구조안전성 평가를 위한 실험연구)

  • Ahn, Jae-Won;Jun, Myoung-Hoon;Lee, Bum-Sik;Lee, Do-Heun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.287-290
    • /
    • 2005
  • Housing is demanded to convert simple dwelling space into delightful one by improving of standard of living by economic development It is interested in the impact noise of the apartment housing that is revised to housing construction criteria at 29 March 2005 and then regulated the level of floor impact noise by the rule. The plan, which is actively investigated by counterplan for the reduction of impact noise, is application of sound insulation. In generally, first target by using insulation is the reduction of floor thermal transmittance in floor heating system of apartment housing. It is recently proposed soft materials that reduce the impact noise. However, it is a fact that the application of soft sound insulation includes some problem about structural performance. In this study, we made wet-heating specimen with various sound insulations, and carried out structralexperiment for evaluating the structural safety of it.

  • PDF

Effects of Expansion of Sleeper Span at the Deck End of a Long Continuous Bridge on Train Safety and Track Stability (장대교량 신축부에서 침목간격 확대가 차량의 주행안전성 및 궤도의 구조안정성에 미치는 영향)

  • Yang, Sin-Chu
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.9
    • /
    • pp.620-627
    • /
    • 2015
  • Long continuous bridge deck can become contracted considerably as temperature drops, which can lead to a large expansion of sleeper span at the end of it. Since this huge sleeper span then can cause problems both with safety of train operation and structural stability of tracks, it is necessary to take the issue into consideration systematically in the designing process of the bridge. In this paper, an evaluation process through the analysis of train-track interaction was presented which can basically review the effects of the expansion of sleeper span at the end of long continuous bridge deck on the safety of the train and the structural stability of the track. The analyses of the interaction between the light rail train and tracks were carried out targeting the sleeper span as a main parameter. The safety of train operation and structural stability of tracks in a light rail system due to the expansion of the sleeper span were evaluated by comparing the numerical results with the related criteria.

Stochastic optimum design of linear tuned mass dampers for seismic protection of high towers

  • Marano, Giuseppe Carlo;Greco, Rita;Palombella, Giuseppe
    • Structural Engineering and Mechanics
    • /
    • v.29 no.6
    • /
    • pp.603-622
    • /
    • 2008
  • This work deals with the design optimization of tuned mass damper (TMD) devices used for mitigating vibrations in high-rise towers subjected to seismic accelerations. A stochastic approach is developed and the excitation is represented by a stationary filtered stochastic process. The effectiveness of the vibration control strategy is evaluated by expressing the objective function as the reduction factor of the structural response in terms of displacement and absolute acceleration. The mechanical characteristics of the tuned mass damper represent the design variables. Analyses of sensitivities are carried out by varying the input and structural parameters in order to assess the efficiency of the TMD strategy. Variations between two different criteria are also evaluated.