• 제목/요약/키워드: Structural Members

검색결과 2,393건 처리시간 0.042초

차체구조용 CFRP 사이드부재의 정적 압궤특성에 관한 연구 (A Study on the Static Collapse Characteristics of CFRP Side Member for Vehicle)

  • 이길성;양인영
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2005년도 추계학술발표대회 논문집
    • /
    • pp.83-86
    • /
    • 2005
  • The front-end side members of automobiles, such as the hat-shaped section member, absorb most of the energy during the front-end collision. The side members absorb more energy in collision if they have higher strength and stiffness, and stable folding capacity (local buckling). Using the above characteristics on energy absorption, vehicle should be designed light-weight to improve fuel combustion ratio and reduce exhaust gas. Because of their specific strength and stiffness, CFRP are currently being considered for many structural (aerospace vehicle, automobiles, trains and ships) applications due to their potential for reducing structural weight. Although CFRP members exhibit collapse modes that are significantly different from the collapse modes of metallic materials, numerous studies have shown that CFRP members can be efficient energy absorbing materials. In this study, the CFRP side members were manufactured using a uni-directional prepreg sheet of carbon/Epoxy and axial static collapse tests were performed for the members. The collapse mode and the energy absorption capability of the members were analyzed under the static load.

  • PDF

직교이방성 판의 좌굴 및 압축재의 국부좌굴에 대한 해석적 연구 (An Analytical Study on the Buckling of Orthotropic Plates and Local Buckling of Compression Members)

  • 최진우;이강연;박정환;윤순종
    • 복합신소재구조학회 논문집
    • /
    • 제3권1호
    • /
    • pp.21-28
    • /
    • 2012
  • 이 연구에서는 직교이방성 판의 좌굴 및 직교이방성 판요소로 구성된 구조용 압축재의 국부좌굴에 대한 해석적 연구를 수행하였다. 섬유보강 폴리머 플라스틱 재료는 높은 비강도 및 비강성, 높은 부식저항성, 경량성 등 강재나 콘크리트와 비교해서 많은 장점을 가지고 있다. 특히, 펄트루젼 생산 방식은 섬유보강 폴리머 플라스틱 재료의 여러가지 생산방법 중 구조용 플라스틱 부재를 대량으로 생산하기에 가장 적합한 방법이다. 펄트루젼 생산방식은 부재의 축을 따라 주요 보강섬유가 배치되기 때문에 이 재료는 직교이방성으로 간주된다. 그러나, 펄트루젼 섬유보강 플라스틱 부재는 낮은 탄성을 갖고 있고 얇은 판요소로 구성되어 있기 때문에 압축하중이 재하될 경우 좌굴이 발생할 수 있다. 따라서, 이 부재를 설계하는데 안정성은 매우 중요한 문제가 된다. 이 연구에서는 기존의 연구를 따라서 직교이방성 판 및 직교이방성 판요소로 구성된 압축재의 국부좌굴에 대하여 검토하였으며, 국내에서 생산된 직교이방성 판요소로 구성된 압축재의 국부좌굴강도를 계산하였다.

보강된 철근콘크리트 벽체의 구조적 성능 (Structural Performance of Retrofitted Reinforced Concrete Walls)

  • 신영수;홍기섭
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제2권3호
    • /
    • pp.212-222
    • /
    • 1998
  • In several structural problems, the low concrete strength of compression members has the severest influence on the structural safety. However, the repairing and strengthening techniques for compression members are not established and evaluated. This study aimed to develop and evaluate the rehabilitation techniques to obtain proper structural strength of wall with low concrete strength. The specimens with low strength of concrete were retrofitted with commonly using section increase method and epoxy bonded glass fiber techniques. The tests were executed to failure under concentric and eccentric loads. In this paper, the structural behavior and failure modes were investigated to evaluate the strengthening effects of walls subjected to compression and out-of-plane bending.

  • PDF

대형 해상크레인의 구조 기본 설계 (A Basic Structural Design for Large Floating Crane)

  • 박찬후;김병우;하문근;전민성
    • 한국해양공학회지
    • /
    • 제19권1호
    • /
    • pp.71-76
    • /
    • 2005
  • This paper describes basic structural design for the large floating crane barge of fixed undulation type. Structural analysis was performed separately after dividing the floating crane into two parts, The crane part was composed of jib boom, back stay and back tower and the barge part supported the crane part. The structural strength for jib boom structural members are in compliance with JIS B 8821 and scantling of all barge structural members are in compliance with the requirement of KR (Korean Register of Shipping) Steel Barges and Rules for Classification of Steel Ships. For the structural analysis of large floating crane, MSC/NASTRAN and MSC/PATRAN software were used.

전단벽식 공동주택의 부재 물성치 및 크기 변화에 따른 슬래브 수직진동 저감 효과 (Vertical Vibration Decrease Effect of Slab in Shear-Wall Structures According to Property and Size of Structural Members)

  • 전호민;유승민
    • 한국주거학회논문집
    • /
    • 제17권3호
    • /
    • pp.61-69
    • /
    • 2006
  • Vertical vibrations on the slab of buildings are affected by types of vibration sources, transfer paths, and the material property and the size of members. Among these parameters, the vibration sources and the transfer path can not be controlled, but the property and the size of members can be controlled in the phase of design the members. In this study, the vibration responses according to the property and size of members were obtained by using a prediction program based on dynamic-stiffness matrix. Three parameters which are not usually considered as major factors for architecral planning were selected fur these analyses. They are the strength of materials, the thickness of wall and the thickness of slab. The ground vibration source located near a building was used as vibration input data in the analyses. This study has its originality on presenting appropriate property and size of structural members in order to reduce vertical vibration of slab in shear-wall structures. Analysing the results from the vibration estimation program according to the variations of parameters, the appropriate ratio among the sizes of structural members were proposed. From these results, the vibration level on the slab which is not constructed yet would be predicted and the vibration peak level can be reduced or shifted into the desirable frequency range. Therefore, the vertical vibration could be controlled in the phase of designing buildings.

The Use of Advanced Optical Measurement Methods for the Mechanical Analysis of Shear Deficient Prestressed Concrete Members

  • Wilder, K. De;Roeck, G. De;Vandewalle, L.
    • International Journal of Concrete Structures and Materials
    • /
    • 제10권2호
    • /
    • pp.189-203
    • /
    • 2016
  • This paper investigates on the use of advanced optical measurement methods, i.e. 3D coordinate measurement machines (3D CMM) and stereo-vision digital image correlation (3D DIC), for the mechanical analysis of shear deficient prestressed concrete members. Firstly, the experimental program is elaborated. Secondly, the working principle, experimental setup and corresponding accuracy and precision of the considered optical measurement techniques are reported. A novel way to apply synthesised strain sensor patterns for DIC is introduced. Thirdly, the experimental results are reported and an analysis is made of the structural behaviour based on the gathered experimental data. Both techniques yielded useful and complete data in comparison to traditional mechanical measurement techniques and allowed for the assessment of the mechanical behaviour of the reported test specimens. The identified structural behaviour presented in this paper can be used to optimize design procedure for shear-critical structural concrete members.

3D finite element analysis of the whole-building behavior of tall building in fire

  • Fu, Feng
    • Advances in Computational Design
    • /
    • 제1권4호
    • /
    • pp.329-344
    • /
    • 2016
  • In this paper, a methodology to simulate the whole-building behaviour of the tall building under fire is developed by the author using a 3-D nonlinear finite element method. The mechanical and thermal material nonlinearities of the structural members, such as the structural steel members, concrete slabs and reinforcing bars were included in the model. In order to closely simulate the real condition under the conventional fire incident, in the simulation, the fire temperature was applied on level 9, 10 and 11. Then, a numerical investigation on the whole-building response of the building in fire was made. The temperature distribution of the floor slabs, steel beams and columns were predicted. In addition, the behaviours of the structural members under fire such as beam force, column force and deflections were also investigated.

규칙파중 항력을 고려한 TLP의 동적응답해석 (A Dynamic Response Analysis of Tension Leg Platforms Including Drag Forces in Regular Waves)

  • 하영록
    • 대한조선학회논문집
    • /
    • 제45권3호
    • /
    • pp.229-237
    • /
    • 2008
  • For predicting the motion and structural responses of tension leg platforms(TLPs) in regular waves, a numerical scheme is introduced. The numerical approach in this paper is based on a combination of the three dimensional source distribution method and the finite element method. The hydrodynamic interactions among TLP members, such as columns and pontoons, are included in the motion and structural response analysis. The drag forces on the submerged slender members, which are proportional to the square of relative velocity, are newly included in order to estimate the responses of members with better accuracy. Comparisons with other's results verifies the works in this paper.

Strengthening of capacity deficient RC beams - An experimental approach

  • Dar, M. Adil;Subramanian, N.;Dar, A.R.;Rather, Amer Iliyas;Atif, Mir;Syed, Sayeeda
    • Structural Engineering and Mechanics
    • /
    • 제70권3호
    • /
    • pp.303-310
    • /
    • 2019
  • Any revision of seismic codes usually demands a higher capacity from structural members, making existing structures unsafe particularly from strength considerations. Retrofitting of capacity deficient members is very suitable for tackling such situations. This paper presents an experimental study on different retrofitting measures adopted for strengthening a series of reinforced concrete (RC) beams. Four identical RC beam specimens were casted, out of which three specimens were strengthened by different schemes (viz., bolted hot rolled flat, bolted cold-formed steel channel, and carbon fibre reinforced polymer (CFRP) laminate, respectively) on their tension face and tested under four-point monotonic loading. This study focuses on the investigation of the flexural behaviour of these retrofitted beams, observed in terms of strength and stiffness. It was concluded that all retrofitting measures improved the structural performance of these beams. However, the cost involved with each strengthening mode was proportional to the improvement in the performance achieved.

Study on the bearing capacity of cold-formed steel under different boundary conditions in transmission towers

  • Han, Junke;Zhao, Xu;Tang, Zhenyun;Ma, Hua;Li, Zhenbao
    • Earthquakes and Structures
    • /
    • 제12권6호
    • /
    • pp.665-672
    • /
    • 2017
  • Cold-formed steel is widely used in steel structures, especially in transmission towers, because of advantages such as low weight, high strength, excellent mechanical properties, etc. However, there is not a special design code for cold-formed steel use in transmission towers in China. For this study, a total of 105 compression members were tested statically to investigate the bearing capacity of cold-formed steel members under different boundary conditions in transmission towers. The test results were compared to the results predicted by the current design codes. For deeper insight, additional coupled members were simulated using finite element analysis. An improved design method was developed based on the experimental and analytical results.