Study on the bearing capacity of cold-formed steel under different boundary conditions in transmission towers  

Han, Junke (Beijing Key Lab of Earthquake Engineering and Structural Retrofit, Beijing University of Technology)
Zhao, Xu (Beijing Key Lab of Earthquake Engineering and Structural Retrofit, Beijing University of Technology)
Tang, Zhenyun (Beijing Key Lab of Earthquake Engineering and Structural Retrofit, Beijing University of Technology)
Ma, Hua (Beijing Key Lab of Earthquake Engineering and Structural Retrofit, Beijing University of Technology)
Li, Zhenbao (Beijing Key Lab of Earthquake Engineering and Structural Retrofit, Beijing University of Technology)
Publication Information
Earthquakes and Structures / v.12, no.6, 2017 , pp. 665-672 More about this Journal
Abstract
Cold-formed steel is widely used in steel structures, especially in transmission towers, because of advantages such as low weight, high strength, excellent mechanical properties, etc. However, there is not a special design code for cold-formed steel use in transmission towers in China. For this study, a total of 105 compression members were tested statically to investigate the bearing capacity of cold-formed steel members under different boundary conditions in transmission towers. The test results were compared to the results predicted by the current design codes. For deeper insight, additional coupled members were simulated using finite element analysis. An improved design method was developed based on the experimental and analytical results.
Keywords
bearing capacity; instability; cold-formed steel; transmission tower; boundary condition;
Citations & Related Records
Times Cited By KSCI : 5  (Citation Analysis)
연도 인용수 순위
1 Bathon, L., Mueller, W.H. and Kempner, L. (1993), "Ultimate load capacity of single steel angles", J. Struct. Eng., 119(1), 279-300.   DOI
2 CMC. (2002), Technical code of cold-formed thin-wall steel structures(GB 50018-2002), China Ministry of Construction. (in Chinese)
3 Dhanalakshmi, M. and Shanmugam, N.E. (2001), "Design for openings in equal-angle cold-formed steel stub columns", Thin-Wall. Struct., 39(2), 167-187.   DOI
4 DL/T5154-2002 (2002), Technical Regulation of design for tower and pole structures of overhead transmission line, China Electric Power Press, Beijing. (in Chinese)
5 Elgaaly, M., Dagher, H. and Davids, W. (1991), "Behavior of single-angle-compression members", J. Struct. Eng., 117(12), 3720-3741.   DOI
6 Feng, P., Zhang, Y.H., Hu, L.L. and Gong, D. (2017), "Buckling of piecewise member composed of steel and high-strength materials in axial compression", Thin-Wall. Struct., 110, 62-74.   DOI
7 Huang, Y.N. and Young, B. (2013), "Experimental and numerical investigation of cold-formed lean duplex stainless steel flexural members", Thin-Wall. Struct., 73, 216-228.   DOI
8 Jackman, D.E. (1984), Guideline for Transmission Line Structural Loading, Committee on Electrical Transmission Structures, American Society of Civil Engineers, ASCE, New York.
9 Jiang, J., Sun, H.F., An, N., Shi, Y., Zhang, Z.Y. and Jing, Y.M. (2014), "Study on applicable conditions of transmission line tower foundation natural grounding in less thunderstorm days region in northwest China", International Conference on Lightning Protection, Shanghai, China, October.
10 Kennedy, J.B. and Murty, M.K.S. (1972), "Buckling of steel angle and tee struts", J. Struct. Div., 98(ST11), 2507-2522.
11 Li, T.J., Li, G.Q., Chan, S.L. and Wang, Y.B. (2016), "Behavior of Q690 high-strength steel columns: Part 1: Experimental investigation", J. Constr. Steel Res., 123, 18-30.   DOI
12 Li, Z., He, M.J., Li, M.H. and Lam, F. (2014), "Damage assessment and performance-based seismic design of timbersteel hybrid shear wall systems", Earthq. Struct., 7(1), 101-117.   DOI
13 Narayanan, S. and Mahendran, M. (2003), "Ultimate capacity of innovative cold-formed steel columns", J. Constr. Steel Res., 59(4), 489-508.   DOI
14 Nashid, H., Clifton, C., Ferguson, G., Hodgson, M., Seal, C. and Choi, J.H. (2015), "Relationship between hardness and plastically deformed structural steel elements", Earthq. Struct., 8(3), 619-637.   DOI
15 Pournara, A.E., Karamanos, S.A., Mecozzi, E. and Lucci, A. (2017), "Structural resistance of high-strength steel CHS members", J. Constr. Steel Res., 128, 152-165.   DOI
16 Wang, F.Y., Xu, Y.L. and Zhan, S. (2016), "Multi-scale model updating of a transmission tower structure using Kriging metamethod", Struct. Control Hlth. Monit., 1-16.
17 Qin, Y. and Chen, Z.H. (2016), "Research on cold-formed steel connections: A state-of-the-art review", Steel Compos. Struct., 20(1), 21-41.   DOI
18 Rosario-Galanes, O. and Godoy, L.A. (2014), "Modeling of windinduced fatigue of cold-formed steel sheet panels", Struct. Eng. Mech., 49(2), 237-259.   DOI
19 Schafer, B.W. and Pekoz, T. (1998), "Computational modeling of cold-formed steel: characterizing geometric imperfections and residual stresses", J. Constr. Steel Res., 47(3), 193-201.   DOI
20 Shahi, R., Lam, N., Gad, E. and Wilson, J. (2013), "Protocol for testing of cold-formed steel wall in regions of low-moderate seismicity", Earthq. Struct., 4(6), 629-647.   DOI
21 Yang, F.L., Han, J.K., Yang, J.B. and Li, Z. (2009), "Study on the application of weathering and cold-formed steel in transmission tower", Asia-Pacific Power and Energy Engineering Conference, Wuhan, China, December.
22 Yang, F.L., Han, J.K., Yang, J.B. and Li, Z.B. (2011), "Study on the buckling behaviour of cold-formed angles in transmission towers", Int. J. Steel Struct., 11(4), 495-508.   DOI
23 Yang, S., Li, H., Zhou, W.J. and Yu, J.H. (2014), "Lightning current waveform observed on transmission line and lightning tower in China", International Conference on Lightning Protection, Shanghai, China, October.
24 Young, B. and Rasmussen, K.J.R. (1999), "Behaviour of coldformed singly symmetric columns", Thin-Wall. Struct., 33(2), 83-102.   DOI
25 Zhou, F. and Young, B. (2007), "Experimental and numerical investigations of cold-formed stainless steel tubular sections subjected to concentrated bearing load", J. Constr. Steel Res., 63(11), 1452-1466.   DOI