• Title/Summary/Keyword: Structural Integrity Evaluation

Search Result 355, Processing Time 0.03 seconds

Study on Evaluation of Structural Integrity for Small Aircraft Tail (소형 항공기 미익부 구조 건전성 평가에 관한 연구)

  • Lee, Muhyoung;Park, Illkyung;Kim, Sungjoon;Ahn, Sukmin
    • Journal of Aerospace System Engineering
    • /
    • v.6 no.2
    • /
    • pp.28-34
    • /
    • 2012
  • Structural integrity evaluation is important item in the aircraft certification. Recently, it is designed for limit load, material weakness about fatigue and corrosion, damage by bird strike in flight to evaluate structural integrity of aircraft. And static/fatigue analysis are performed to secure structural integrity, it was verified by static and fatigue tests. To evaluate the structural integrity of small aircraft tail, structural integrity was calculated by the finite element analysis. In the present study, finite element analysis are performed to pick out load cases in flight occurrence, and secure margin of safety to evaluate structural integrity of KC-100 tail unit. The proprieties of finite element analysis results are compared with the static structure test results. The estimation process of structural integrity for small aircraft tail may help the design.

Evaluation of Structural Integrity of Three-axle Bogie Frame used in Railway Freight Cars (평판화차에 사용되는 3축 대차의 구조 안전성 평가)

  • Kang, Seung-Gu;Shin, Kwang-Bok;Im, Jae-Moon;Park, Jung-Joon;Jeon, Seung-Gie
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.26 no.4
    • /
    • pp.436-440
    • /
    • 2017
  • This study evaluated the design and structural integrity of a three-axle bogie frame in a railway freight car through a numerical analysis and an experimental evaluation. A three-axle bogie frame, which supports the weight of the car body and load, is required to transport heavier cargo because two-axle vehicles have structural limitations. Therefore, this study performed a structural analysis and static load tests to evaluate the design and structural integrity of a three-axle bogie frame. The results obtained from the numerical analysis were compared to those of the experiments. For the bogie frame used in the experiments, a failure evaluation was performed using non-destructive methods. The numerical analysis and experimental evaluation were satisfactory for the structural integrity evaluation.

Evaluation of Structural Integrity and Performance Using Nondestructive Testing and Monitoring Techniques

  • Rhim, Hong-Chul
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.2 no.3
    • /
    • pp.73-81
    • /
    • 1998
  • In this paper, the necessity of developing effective nondestructive testing and monitoring techniques for the evaluation of structural integrity and performance is described. The evaluation of structural integrity and performance is especially important when the structures and subject to abrupt external forces such as earthquake. A prompt and extensive inspection is required over a large area of earthquake-damaged zone. This evaluation process is regarded as a part of performance-based design. In the paper, nondestructive testing and monitoring techniques particularly for concrete structures are presented as methods for the evaluation of structural integrity and performance. The concept of performance-based design is first defined in the paper followed by the role of evaluation of structures in the context of overall performance=based design concept. Among possible techniques for the evaluation, nondestructive testing methods for concrete structures using radar and a concept of using fiber sensor for continuous monitoring of structures are presented.

  • PDF

Development of Integrity Evaluation Techniques for Concrete Structures (콘크리트 구조물의 건전성 평가 기법 개발)

  • 정연주;김도겸;이장화;조명석;송영철
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.623-626
    • /
    • 1999
  • Structural integrity in concrete structures are affected by materialistic and environmental factors. Therefore, to develop a objective integrity evaluation method is extremely difficult. In this study, preliminary integrity evaluation method for concrete structures was proposed by conducting by visual and detailed inspection for in-situ conditions based on the weighting factors for structural significance and integrity degrading factors of each element constituting concrete structures.

  • PDF

A Study on Evaluation of Structural Integrity and Fatigue Analysis for the Bogie Frame of Monorail (모노레일 대차프레임에 대한 구조 안전성 및 피로강도 평가에 관한 연구)

  • Ko, Hee-Young;Shin, Kwang-Bok;Lee, Kwang-Seop;Lee, Eun-Gyu
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.609-614
    • /
    • 2010
  • In this paper, the structural integrity and fatigue strength for the bogie frame of Monorail being developed in domestic was evaluated. Presently, the standard of evaluation for the bogie frame of monorail was not regulated. Therefore, the evaluation of the structural integrity and fatigue strength for the bogie frame was performed on the basis of the UIC 615-4 standard. The structural integrity of the designed bogie frame was evaluated by displacement and Von-Mises stress under each load conditions. And the fatigue strength was evaluated by combined main in-service load conditions specified at UIC 615-4 standard and it was compared with result of fatigue analysis using winLIFE v3.1 with the function of batch processing. The results shows that the structural integrity and fatigue strength of the designed bogie frame was satisfied, and the fatigue analysis using batch processing was more effective than conventional fatigue analysis using combined load conditions.

  • PDF

Evaluation of Structural Integrity about Structural Design for Internal Components of Aircraft Engine (항공기 엔진 구성품 내부 구조 설계에 대한 구조 안전성 평가)

  • Hyunbum Park
    • Journal of Aerospace System Engineering
    • /
    • v.17 no.5
    • /
    • pp.58-62
    • /
    • 2023
  • In this work, the structural integrity was investigated of the structural design results of internal components for the aircraft engine. The radiator and intercooler were combined with the internal components of the engine. Therefore, the safety of the radiator and intercooler was investigated during flight conditions. The structural integrity was evaluated through structural analysis, using the finite element analysis method. The acceleration load for structural design and analysis was considered. The structural safety evaluation found the structural design results to be valid.

Structural Integrity and Safety Margin Evaluation for Thinned Pipe Component (감육배관의 구조건전성 및 안전여유도 평가 기술)

  • Lee, Sung-Ho;Kim, Tae-Ryong;Kim, Bum-Nyun
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.264-267
    • /
    • 2004
  • Wall thinning of carbon steel pipe components due to Flow-Accelerated Corrosion (FAC) is one of the most serious threats to the integrity of steam cycle piping systems in Nuclear Power Plants (NPP). Since the mid-1990s, secondary side piping systems in Korean NPPs have experienced wall thinning, leakages and ruptures caused by FAC. Korea Electric power Research Institute (KEPRI) and Korea Hydro & Nuclear Power Co., LTD. (KHNP) have conducted a study to develop the methodology for systematic pipe management and established the Korean Thinned Pipe Management Program (TPMP). To effectively maintain the integrity of piping system, FAC engineer should understand the criterions of the structural integrity evaluation and the safety margin assessment for the thinned pipe component. This paper describes the technical items of TPMP, and shows the example of the integrity evaluation and safety margin assessment for three thinned pipe component of a NPP.

  • PDF

Study on Evaluation Method of Structural Integrity of Cylindrical Composite Lattice Structures (원통형 복합재 격자구조체의 구조안전성 평가 기법 연구)

  • Im, Jae-Moon;Kang, Seung-Gu;Shin, Kwang-Bok;Lee, Sang-Woo
    • Composites Research
    • /
    • v.30 no.6
    • /
    • pp.338-342
    • /
    • 2017
  • In this paper, evaluation method of structural integrity of cylindrical composite lattice structures was conducted. A finite element analysis was used to evaluate the structural integrity of composite lattice structures. In order to verify the optimal finite element in the evaluation of the structural integrity, finite element models for cylindrical composite lattice structure were generated using beam, shell and solid elements. The results of the finite element analyses with the shell and solid element models showed a good agreement. However, considerable differences were found between the beam element model and the shell and solid models. This occurred because the beam element does not take into account the degradation of the mechanical properties of the non-intersection parts of cylindrical composite lattice structures. It was found that the finite element analysis of evaluation of structural integrity for cylindrical composite lattice structures have to use solid element.

Study on Evaluation Method of Structural Integrity for Cone-Type Composite Lattice Structures with Hexagonal Cell (육각 격자구조를 갖는 콘형 복합재 격자구조체의 구조안전성 평가 기법 연구)

  • Im, Jae-Moon;Kang, Seung-Gu;Shin, Kwang-Bok;Lee, Sang-Woo
    • Composites Research
    • /
    • v.31 no.4
    • /
    • pp.156-160
    • /
    • 2018
  • In this paper, evaluation method of structural integrity for cone-type composite lattice structures with hexagonal cell was conducted. A finite element analysis was used to evaluate the structural integrity of cone-type composite lattice structure. The finite element model for evaluation of structural integrity was generated using solid element. In order to consider the difference in mechanical properties between intersection and non-intersection part, the mechanical properties were applied considering the fiber volume fraction of each part. Compression test of cone-type composite lattice structure were conducted for verification of evaluation method of structural integrity. The analysis result showed 2% errors in displacement and good agreement with test result.

An Evaluation of Structural Integrity and Fatigue Strength for the Bogie Frame of Monorail (모노레일 대차 프레임에 대한 구조 안전성 및 피로강도 평가)

  • Ko, Hee-Young;Shin, Kwang-Bok;Lee, Kwang-Seop;Lee, Eun-Gyu
    • Journal of the Korean Society for Railway
    • /
    • v.13 no.5
    • /
    • pp.469-475
    • /
    • 2010
  • In this paper, the structural integrity and fatigue strength for the bogie frame of Monorail being developed in domestic was evaluated. Presently, the standard of evaluation for the bogie frame of monorail was not regulated. Therefore, the evaluation of the structural integrity and fatigue strength for the bogie frame was performed on the basis of the UIC 615-4 standard. The structural integrity of the designed bogie frame was evaluated by displacement and Von-Mises stress under each load conditions. And the fatigue strength was evaluated by combined main in-service load conditions specified at UIC 615-4 standard and it was compared with result of fatigue analysis using winLIFE v3.1 with the function of batch processing. The results shows that the structural integrity and fatigue strength of the designed bogie frame was satisfied, and the fatigue analysis using batch processing was more effective than conventional fatigue analysis using combined load conditions.