• 제목/요약/키워드: Structural Analyses

검색결과 3,146건 처리시간 0.036초

폐쇄단조용 복동링크유압식 다이세트의 링크의 정역학적 해석과 구조해석 (Static and Structural Analyses of the Link of a Double-Action Link-Type Hydraulic Die Set)

  • 엄재근;전병윤;전만수
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.93-94
    • /
    • 2006
  • This paper presents the mechanics of the link of a double-action link-type hydraulic die set for the enclosed die forging. The force exerted on the link is statically investigated and its structural analysis is carried out.

  • PDF

원자력발전소 보호시스템 캐비넷의 내진검증 (Seismic Qualification of Plant Protection System Cabinet for Nuclear Power Plant)

  • 정명조;박근배;황원걸
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1992년도 가을 학술발표회 논문집
    • /
    • pp.148-155
    • /
    • 1992
  • A method to verify seismic qualification of the plant protection system cabinet for a nuclear power plant is presented. A finite element model of the cabinet is developed and correlated to the dynamic properties observed during in-situ vibration test of the actual structure. The results of the modal analysis provide insight into the fundamental dynamic properties of the structure. Techniques for verifying structural integrity and operability are exemplified by summarizing response spectrum and time history analyses of the structure.

  • PDF

극저온 물성을 고러한 콘크리트 구조물의 비선형 해석 (Nonlinear Analysis of Concrete Structure at Extremely Low Temperature)

  • 곽효경;송종영;이병국;이광모
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2000년도 가을 학술발표회논문집
    • /
    • pp.174-181
    • /
    • 2000
  • A brief review of previous studies on the behaviour of concrete at extremely low temperature is presented in this paper. In addition, to describe temperature dependent behaviour of concrete, simple piecewise linear stress-strain relation is introduced. The proposed curve shows good agreement with experimental stress-strain curves at various temperature conditions. Moreover, numerical analyses for two PC beams are conducted to verify the influence of extremely low temperature to the structural behaviour.

  • PDF

Structural robustness of RC frame buildings under threat-independent damage scenarios

  • Ventura, Antonio;De Biagi, Valerio;Chiaia, Bernardino
    • Structural Engineering and Mechanics
    • /
    • 제65권6호
    • /
    • pp.689-698
    • /
    • 2018
  • This study focuses on a novel procedure for the robustness assessment of reinforced concrete (RC) framed structures under threat-independent damage scenarios. The procedure is derived from coupled dynamic and non-linear static analyses. Two robustness indicators are defined and the method is applied to two RC frame buildings. The first building was designed for gravity load and earthquake resistance in accordance with Eurocode 8. The second was designed according to the tie force (TF) method, one of the design quantitative procedures for enhancing resistance to progressive collapse. In addition, in order to demonstrate the suitability and applicability of the TF method, the structural robustness and resistance to progressive collapse of the two designs is compared.

구조최적화를 위한 병렬유전자 알고리즘 (Parallel Genetic Algorithm for Structural Optimization on a Cluster of Personal Computers)

  • 이준호;박효선
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2000년도 가을 학술발표회논문집
    • /
    • pp.40-47
    • /
    • 2000
  • One of the drawbacks of GA-based structural optimization is that the fitness evaluation of a population of hundreds of individuals requiring hundreds of structural analyses at each CA generation is computational too expensive. Therefore, a parallel genetic algorithm is developed for structural optimization on a cluster of personal computers in this paper. Based on the parallel genetic algorithm, a population at every generation is partitioned into a number of sub-populations equal to the number of slave computers. Parallelism is exploited at sub-population level by allocationg each sub-population to a slave computer. Thus, fitness of a population at each generation can be concurrently evaluated on a cluster of personal computers. For implementation of the algorithm a virtual distributed computing system in a collection of personal computers connected via a 100 Mb/s Ethernet LAN. The algorithm is applied to the minimum weight design of a steel structure. The results show that the computational time requied for serial GA-based structural optimization process is drastically reduced.

  • PDF

Seismic response of masonry infilled RC frames: practice-oriented models and open issues

  • Lima, Carmine;De Stefano, Gaetano;Martinelli, Enzo
    • Earthquakes and Structures
    • /
    • 제6권4호
    • /
    • pp.409-436
    • /
    • 2014
  • Although it is widely accepted that the interaction -between masonry infill and structural members significantly affects the seismic response of reinforced concrete (RC) frames, this interaction is generally neglected in current design-oriented seismic analyses of structures. Moreover, the role of masonry infill is expected to be even more relevant in the case of existing frames designed only for gravitational loads, as infill walls can significantly modify both lateral strength and stiffness. However, the additional contribution to both strength and stiffness is often coupled to a modification of the global collapse mechanisms possibly resulting in brittle failure modes, generally related to irregular distributions of masonry walls throughout the frame. As a matter of principle, accurate modelling of masonry infill should be at least carried out by adopting nonlinear 2D elements. However, several practice-oriented proposals are currently available for modelling masonry infill through equivalent (nonlinear) strut elements. The present paper firstly outlines some of the well-established models currently available in the scientific literature for modelling infill panels in seismic analyses of RC frames. Then, a parametric analysis is carried out in order to demonstrate the consequences of considering such models in nonlinear static and dynamic analyses of existing RC structures. Two bay-frames with two-, three- and four-storeys are considered for performing nonlinear analyses aimed at investigating some critical aspects of modelling masonry infill and their effects on the structural response. Particularly, sensitivity analyses about specific parameters involved in the definition of the equivalent strut models, such as the constitutive force-displacement law of the panel, are proposed.

하나로 유동관의 동적유체질량 (Hydrodynamic Masses of HANARO Flow Tubes)

  • 류정수;김두기
    • 한국전산구조공학회논문집
    • /
    • 제14권4호
    • /
    • pp.413-422
    • /
    • 2001
  • 본 연구에서는 수중에 잠긴 하나로 유동관에 작용하는 유체에 의한 동적유체질량이 유동관의 동적 거동과 지진응답에 미치는 영향에 대해서 연구하였다. 우선 구조물의 주변 유체를 유한요소로 모형화하여 수중에 잠긴 유동관의 단위길이당 작용하는 동적유체질량을 구하였다. 유한요소법으로 구한 동적유체질량을 사용하여 수중에 잠긴 실제의 육각형 유동관에 관하여 동특성 해석과 지진응답스펙트럼 해석을 한 후에, 유동관의 동적특성실험으로부터 계측한 결과와 비교/검증하였다. 여러가지 방법을 사용하여 유동관에 작용하는 유체의 동적유체질량을 구한 후에, 이를 사용하여 수중에 잠긴 유동관을 동적 해석하였다. 여기서 구한 결과들을 비교/검토하여 실제의 하나로 유동관의 동적 해석에 사용할 수 있는 적합한 기준을 제시하였다.

  • PDF

통합된 CAD/CAE 자동화 System을 이용한 구조강도해석 및 설계최적화에 관한 연구 (A Study on the Structural Analysis & Design Optimization Using Automation System Integrated with CAD/CAE)

  • 윤종민;원준호;김종수;최주호
    • 한국CDE학회논문집
    • /
    • 제11권2호
    • /
    • pp.128-137
    • /
    • 2006
  • In this paper, a CAD/CAE integrated optimal design system is developed, in which design and analysis process is automated using CAD/CAE softwares for a complex model in which the modeling by parametric feature is not easy to apply. Unigraphics is used for CAD modeling, in which the process is automated by using UG/Knowledge Fusion for modeling itself and UG/Open API function for the other functions respectively. Structural analyses are also carried out automatically by ANSYS using the imported parasolid model. The developed system is applied for the PLS(Plasma Lighting System) consisting of more than 20 components, which is a next generation illumination system that is used to illuminate stadium or outdoor advertizing panel. The analyses include responses by static, wind and impact loads. As a result of analyses, tilt assembly, which is a link between upper and lower body, is found to be the most critical component bearing higher stresses. Experiment is conducted using MTS to validate the analysis result. Optimization is carried out using the software Visual DOC for the tilt assembly to minimize material volume while maintaining allowable stress level. As a result of optimization, the maximum stress is reduced by 57% from the existing design, though the material volume has increased by 21%.

가스발생기 산화제 개폐밸브 주름관 구조 평가 (Structural Evaluations of the Bellows for a Gas-generator Lox Shut-off Valve)

  • 유재한;이중엽;이수용;임형태
    • 항공우주기술
    • /
    • 제11권1호
    • /
    • pp.91-97
    • /
    • 2012
  • 가스발생기 산화제 개폐 밸브에 사용되는 주름관의 구조 해석 및 시험이 수행되었다. 이 주름관은 극저온에서 압축 변위와 높은 외압 하중을 받는다. 구조 해석은 상온 및 극저온에서 EJMA (Expansion Joint Manufacturing Association) 표준 및 상용 유한 요소 해석프로그램인 Abaqus v6.9를 이용하여 수행되었다. 스프링 강성, 응력 및 피로 수명 해석 결과들이 비교되었고 유한 요소 해석 결과에서 접촉 및 재질의 소성에 의한 영향을 살펴보았다. 또한 파열 시험과 관련된 유한 요소 해석 결과도 제시되었다.

Effective buckling length of steel column members based on elastic/inelastic system buckling analyses

  • Kyung, Yong-Soo;Kim, Nam-Il;Kim, Ho-Kyung;Kim, Moon-Young
    • Structural Engineering and Mechanics
    • /
    • 제26권6호
    • /
    • pp.651-672
    • /
    • 2007
  • This study presents an improved method that uses the elastic and inelastic system buckling analyses for determining the K-factors of steel column members. The inelastic system buckling analysis is based on the tangent modulus theory for a single column and the application is extended to the frame structural system. The tangent modulus of an inelastic column is first derived as a function of nominal compressive stress from the column strength curve given in the design codes. The tangential stiffness matrix of a beam-column element is then formulated by using the so-called stability function or Hermitian interpolation functions. Two inelastic system buckling analysis procedures are newly proposed by utilizing nonlinear eigenvalue analysis algorithms. Finally, a practical method for determining the K-factors of individual members in a steel frame structure is proposed based on the inelastic and/or elastic system buckling analyses. The K-factors according to the proposed procedure are calculated for numerical examples and compared with other results in available references.