• 제목/요약/키워드: Strontium-containing

검색결과 29건 처리시간 0.024초

Perovskite-Like Strontium Titanium Zirconium Oxide Solid Solutions Prepared at Atmospheric Pressure

  • Choy, Jin-Ho;Kim, Ha-Suck;Kwon, Young-Uk;Kim Chong Hee
    • Bulletin of the Korean Chemical Society
    • /
    • 제6권6호
    • /
    • pp.344-347
    • /
    • 1985
  • Perovskite type oxides of $SrTiO_3,SrZrO_3,and\;SrTi_{1-x}Zr_xO_3$ have been systematically synthesized at $1250^{\circ}C$and $1550^{\circ}C$ with specimens containing additions of up to x=0.9 of zirconium by solid state reactions and characterized by X-ray diffraction. X-ray diffraction studies showed that the compound $SrTi_{1-x}Zr_xO_3$ has cubic structure. The lattice paramters of $SrTi_{1-x}Zr_xO_3$ solid solutions obey the Vegard's law and fairly large increase in volume can acompany the formation of this solution with increasing Zr content(X). Assuming the lattice constants of perovskite type compounds $A(B_{1-x}B'_x)O_3$where $B_{1-x}B'_x$ is $Ti_{1-x}Zr_x$, to be a linear function of the ionic radii of B and B' ions, the disordered ion pair of $Ti^{4+}$and $Zr^{4+}$ was verified from the lattice constants of a series compounds varying x=0,0.05, 0.25, 0.5, 0.75, 0.9, and 1.0 with known isovalent pairs.

민감성 치아에 대한 수산화인회석 함유 치약의 임상적 효과 (The clinical effects of a hydroxyapatite containing toothpaste for dentine hypersensitivity)

  • 김수환;박준범;이철우;구기태;김태일;설양조;이용무;구영;정종평;류인철
    • Journal of Periodontal and Implant Science
    • /
    • 제39권1호
    • /
    • pp.87-94
    • /
    • 2009
  • Purpose: The aim of this study was to compare the effectiveness of hydroxyapatite containing toothpaste with positive control toothpastes in reducing dentine hypersensitivity. Materials and methods: This clinical trial was a double-blind, randomized, parallel group comparison of two, namely hydroxyapatite containing toothpaste and strontium chloride containing toothpaste. A total of 55 subjects were included in this study. The subjects were given randomly assigned one of the two toothpastes after received tooth brushing instruction at baseline. Some clinical indices(PI, GI, PD), verbal rating score(VRS) for sensitivity to stimulus, the effect in relieving sensitivity and visual analogue scale(VAS) for sensitivity at baseline, week 2, week 4 and week 8 were assessed. All data were evaluated by intention-to-treat analysis. Results: Overall, PI and GI scores were significantly reduced compare baseline in all groups(p<0.05). In addition, there was significant difference in PI at 4 weeks and in GI at 4, 8 weeks between groups. The proportions of subjects relieved sensitivity were 70.4% in experimental group and 57.1% in control group at 8 weeks respectively. The VRS for sensitivity to three kinds of stimuli and VAS for sensitivity decreased according to time, there was no overall difference between two groups(p>0.05). Conclusion: This study demonstrated that the new hydroxyapatite containing toothpaste was similarly effective in reducing dentine hypersensitivity with pre-existing benchmark toothpaste.

Electrochemical characteristics of Ca, P, Sr, and Si Ions from PEO-treated Ti-6Al-4V Alloy Surface

  • Yu, Ji-Min;Choe, Han-Cheol
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2017년도 춘계학술대회 논문집
    • /
    • pp.154-154
    • /
    • 2017
  • Ti-6Al-4V alloys are widely used as metal-lic biomaterials in dentistry and orthopedics due to its excellent biocompatibility and me-chanical properties. However, because of low biological activity, it is difficult to form bone growth directly on the surface of titanium implants. For this reason, surface treatment of plasma electrolytic oxidation(PEO) was used for dental implants. To enhance bioac-tivity on the surface, strontium(Sr) and sili-con(Si) ions can be added to PEO treated sur-face in the electrolyte containing these ions. The presence of Sr in the coating enhances osteoblast activity and differentiation, where-as it inhibits osteoclast production and prolif-eration. And Si has been found to be essen-tial for normal bone, cartilage growth, and development. In this study, electrochemical characteristics of Ca, P, Sr, and Si ions from PEO-treated Ti-6Al-4V alloy surface was re-searched using various experimental instruments. DC power is used and Ti-6Al-4V al-loy was subjected to a voltage of 280 V for 3 minutes in the electrolyte containing 5, 10, 20M% Sr ion and 5M% Si ion. The morphol-ogies of PEO-treated Ti-6Al-4V alloy by electrochemical anodization were examined by field-emission scanning electron micro-scopes (FE-SEM), energy dispersive x-ray spectroscopy (EDS), x-ray diffraction (XRD) and corrosion analysis using AC impedance and potentiodynamic polarization test in 0.9% NaCl solution at similar body tempera-ture using a potentiostat with a scan rate of 1.67mV/s and potential range from -1500mV to + 2000mV.

  • PDF

NH4F 융제가 바륨 스트론튬 실리케이트계 형광체의 특성에 미치는 영향 (Effect of NH4F Flux on the Characteristics of Barium Strontium Silicate Phosphor Particles)

  • 강희상;구혜영;정대수;주서희;홍승권;강윤찬;정경열;박승빈
    • 한국재료학회지
    • /
    • 제15권6호
    • /
    • pp.408-412
    • /
    • 2005
  • [ $Ba_{1.5}Sr_{0.5}SiO_4:Eu$ ] phosphor particles with high photoluminescence intensity under long wavelength ultraviolet were prepared by spray pyrolysis. We investigated the effect of $NH_4F$ flux added into starting solution on the morphology and photoluminescence intensity of $Ba_{1.5}Sr_{0.5}SiO_4:Eu$ phosphor prepared by spray pyrolysis. $Ba_{1.5}Sr_{0.5}SiO_4:Eu$ phosphor particles prepared from starting solution containing $NH_4F$ flux had the maximum photoluminescence intensity at the post-treatment temperature of $1200^{\circ}C$ and the maximum photoluminescence intensity of $Ba_{1.5}Sr_{0.5}SiO_4:Eu$ phosphor particles prepared from the starting solution containing $NH_4F$ flux was $137\%$ of that of the phosphor particles prepared from the starting solution without flux material. $Ba_{1.5}Sr_{0.5}SiO_4:Eu$ phosphor particles prepared from starting solution containing $NH_4F$ flux had larger size and more aggregated morphology than those prepared from starting solution without flux material. The photoluminescence intensity of $Ba_{1.5}Sr_{0.5}SiO_4:Eu$ phosphor particles prepared from starting solution containing $NH_4F$ flux above $3wt.\%$ had high photoluminescence intensities. The addition amount of $NH_4F$ flux showing the maximum photoluminescence intensity was $12wt.\%$. The optimum amount of $NH_4F$ flux was $5wt.\%$ when we considered the morphological and photoluminescence characteristics of $Ba_{1.5}Sr_{0.5}SiO_4:Eu$ ohosphor particles prepared by spray pyrolysis.

기질레진의 조성에 따른 복합레진의 물리적 성질에 관한 연구 (EFFECT OF RESIN MATRIX ON DEGREE OF CONVERSION AND FRACTURE TOUGHNESS OF DENIAL COMPOSITES)

  • 이연신;최경규;박상진
    • Restorative Dentistry and Endodontics
    • /
    • 제27권1호
    • /
    • pp.77-86
    • /
    • 2002
  • Current composites are made with dimethacrylate monomers and silane-treated silica microfillers, either alone or with silane treated glass fillers The main reasons for clinical failure of dental composites are secondary caries, wear and fracture. Most of practitioner want to get a composite which is more tougher under occlusal stress, less polymerization contraction, and better handling properties in application clinically. The aim of this study was to investigate the influence of resin matrix with various flows on the physical proper-ties such as fracture toughness and degree of conversion of the experimental resins. It was hypothesized that flexible or tough resin composites can be designed by judicious choice of monomer composition Various flow resin matrices containing Bis-GMA, UDMA, and TEG-DMA were made by altering the pro-portion of the monomers. After the unfilled resins were light-cured for different light intensity, the fracture toughness(K$_{1c}$) was measured according to ASTM standard using the single edge notched geometry, and degree of conversion(DC) was measured by FTIR. And experimental composites were formulated with variations in the proportion of silanated quartz and strontium glass fillers as 60, 75, and 77wt%. Also, the physical properties of composites with various filer contents were evaluated as same manner. All resulting data were compared by ANOVA/Tukeys test at 0.05 level. The results were as follows; 1. The degree of conversion of high flow resin containing less Bis-GMA was higher than that of low flow unfilled resin 2. While the degree of conversion of unfilled resin was increased according to light intensity for polymerization, there was no significant increase with moderate and high light intensity. Also, the fracture toughness was not increased by high light intensity. 3. The fracture toughness was high in the low flow unfilled resin containing higher contents of Bis-GMA. 4. There was a significant increase for fracture toughness and a tendency for degree of conversion to be reduced when the content of fillers was increased. 5. In the experimental composites, the flow of resin matrix did not affected on the fracture toughness, even, which was decreased as increase of viscosity. These results showed that the physical properties of a dental composite could be attributed to the flow of resin matrix with relative content of monomers. Specific combination of resin monomers should be designed to fulfil the needs of specific indication for use.

Vitrification of Highly Active Liquid Waste(I) (Thermal Decomposition of Nitrates and Additives for Glass-making)

  • Chun, Kwan-Sik;Lee, Sang-Hoon
    • Nuclear Engineering and Technology
    • /
    • 제9권4호
    • /
    • pp.211-222
    • /
    • 1977
  • 고준위 방사성 폐액의 고화처리 방법들 중 하나인 Vitrification Process의 연구로서 핵연료 재처리 과정에서 유출되는 가상적인 비활성폐액 중에 함유되어 있는 분열 및 부식 생성물들의 질산화물과 유리화시키기 위해 사용되는 첨가제의 열분해에 관하여 연구 조사되었다. 결정수를 갖고 있는 화합물들의 열분해시점은 75$^{\circ}C$이하였지만, 무수화합물들은 비교적 높은 분포를 보였다. 110$0^{\circ}C$까지 가열하여 얻어진 질량손실율을 이론치와 비교하였을 때, 대부분의 화합물은 릴치하거나 근사하였지만, Sodium, Cesium, Lithium, Ruthenium 등의 질산화물의 질량손실율은 이론치 보다 훨씬 높았다. 여기서 얻어진 결과는 고준위 폐액의 가소처리과정 또는 조사된 화합물들의 혼합에 따른 열분해를 분석하는데도 이용될 수 있을 것이다.

  • PDF

VUV 이오나이저용 Ca-Sr-Ba계 산화물 캐소드에 낮은 일함수를 갖는 금속산화물 첨가의 영향 (Effects on Addition of Metal Oxides with Low Workfunctions on the Ca-Sr-Ba Oxide Cathodes for VUV Ionizers)

  • 박승규;이종혁;김란희;정주형;한완규;이수현;전성우;김대준;김도윤;이광섭
    • 한국재료학회지
    • /
    • 제29권4호
    • /
    • pp.241-251
    • /
    • 2019
  • There are several manufacturing techniques for developing thermionic cathodes for vacuum ultraviolet(VUV) ionizers. The triple alkaline earth metal emitters(Ca-Sr-Ba) are formulated as efficient and reliable thermo-electron sources with a great many different compositions for the ionizing devices. We prepare two basic suspensions with different compositions: calcium, strontium and barium. After evaluating the electron-emitting performance for europium, gadolinium, and yttrium-based cathodes mixed with these suspensions, we selected the yttrium for its better performance. Next, another transition metal indium and a lanthanide metal neodymium salt is introduced to two base emitters. These final composite metal emitters are coated on the tungsten filament and then activated to the oxide cathodes by an intentionally programmed calcination process under an ultra-high vacuum(${\sim}10^{-6}torr$). The performance of electron emission of the cathodes is characterized by their anode currents with respect to the addition of each element, In and Nd, and their concentration of cathodes. Compared to both the base cathodes, the electron emission performance of the cathodes containing indium and neodymium decreases. The anode current of the Nd cathode is more markedly degraded than that with In.

A rapid separation of Cs, Sr and Ba using gas pressurized extraction chromatography with inductively coupled plasma-mass spectrometry

  • Sojin Jeong;Jihye Kim;Hanul Cho;Hwakyeung Jeong;Byungman Kang;Sang Ho Lim
    • 분석과학
    • /
    • 제37권2호
    • /
    • pp.123-129
    • /
    • 2024
  • We present a rapid method for the determination of Cs, Sr, and Ba, heat generators found in highly active liquid wastes, by gas-pressurized extraction chromatography (GPEC) using a column containing a cation-exchange resin. GPEC is a microscale column chromatographic technique that uses a constant flow rate of solvent (0.07 mL/min) with pressurized nitrogen gas supplied through a valve. In particular, because this method uses a small sample volume (a few hundred microliters), it produces less chemical waste and allows for faster separation compared to traditional column chromatography. In this study, we evaluated the separation of Cs, Sr, and Ba using GPEC. The eluate from the column (GPEC or conventional column chromatography) was quantitatively analyzed using inductively coupled plasma-mass spectrometry to measure the column recovery and precision. The column reproducibility of the proposed GPEC system (RSDs of recoveries) ranged from 2.7 to 4.1 %, and the column recoveries for the three elements ranged from 72 to 98% when aqueous HCl was used as the eluent. The GPEC results are slightly different in efficiency and separation resolution compared to those of conventional column chromatography because of the differences in the eluent flow rate as well as the internal diameter and length of the column. However, the two methods had similar recoveries for Cs and Sr, and the precision of GPEC was improved by two-fold. Remarkably, the solvent volume required for GPEC analysis was five times lower than that of the conventional method, and the total analysis time was 11 times shorter.

$SrAl_{12}O_{19}:Mn^{4+}$ 적색 형광체의 플럭스와 Mn 농도에 따른 영향 및 발광특성 (Photoluminescence properties of $SrAl_{12}O_{19}:Mn^{4+}$ red phosphor depending on Mn concentration and fluxes)

  • 박우정;정몽권;문지욱;윤대호
    • 한국결정성장학회지
    • /
    • 제17권4호
    • /
    • pp.156-159
    • /
    • 2007
  • 본 연구에서는 장파장 UV 영역하에서 비교적 우수한 발광강도를 가지는 적색 형광체를 얻기 위하여 고상법으로 합성하여 발광특성을 관찰하였다. $SrAl_{12}O_{19}:Mn^{4+}$ 적색 형광체의 발광강도는 $Mn^{4+}$$^2E\to^4A_2$ 천이 때문에 643, 656, 666, 671 nm에서 4개의 sharp한 peak이 $600{\sim}700 nm $의 영역에서 발생하였으며, 여기 스펙트럼은 $250{\sim}550 nm$ 넓은 영역에서 338, 398, 468nm 3개의 peak이 발생하였다. 또한 $SrAl_{12}O_{19}:Mn^{4+}$에 0.67mol% MgO를 함유한 $SrAl_{12}O_{19}:Mn^{4+}$의 상대적인 발광강도는 $SrAl_{12}O_{19}:Mn^{4+}$ 보다 약 30% 정도 증가하였는데, 이러한 원인은 MgO가 첨가되어 $Al_2O_3$ 부분에 대체되어진 것으로 사료된다. 또한, 발광강도를 향상시키기 위하여 0.67mol% MgO를 함유한 $SrAl_{12}O_{19}:Mn^{4+}$ 시료에 $CaF_2$를 첨가하였다. 0.67mol% $CaF_2$와 0.67mol% MgO를 함유한 $SrAl_{12}O_{19}:Mn^{4+}$의 656nm에서의 상대적인 발광강도는 융제를 첨가하지 않은 $SrAl_{12}O_{19}:Mn^{4+}$보다 약 48% 이상 증가하였다.