• Title/Summary/Keyword: Stripping efficiency

Search Result 94, Processing Time 0.027 seconds

Ammonia Removal Characteristics in Membrane Contactor System Using Tubular PTFE Membrane (관형 PTFE 분리막을 이용한 막 접촉기(Membrane Contactor) 시스템에서 암모니아의 제거 특성)

  • Ahn, Yong-Tae;Hwang, Yu-Hoon;Shin, Hang-Sik
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.5
    • /
    • pp.353-358
    • /
    • 2011
  • In this study, ammonia removal characteristics in membrane contactor system under various operating conditions were evaluated. The mass transfer coefficient was used to quantitatively compare the effect of various operation conditions on ammonia removal efficiency. Effective removal of ammonia was possible with the tubular PTFE membrane contactor system at all tested conditions. Among the various operation parameters, contact time and solution pH showed significant effect on ammonia removal mechanism. Overall ammonia removal rate was not significantly affected by influent suspended solution concentration unlike other pressure driven membrane filtration processes. Also the osmotic distillation phenomena which deteriorate the mass transfer efficiency can be minimized by preheating of strip solution. Membrane contactor system can be a possible alternative to treat high strength nitrogen wastewater by optimizing operation conditions such as stripping solution flow rate, influent wastewater temperature, and influent pH.

Fabrication of High Purity Ga-containing Solution using MOCVD dust (유기금속화학증착 분진(MOCVD dust)을 이용한 갈륨 함유 고순도 수용액 제조 연구)

  • Lee, Duk-Hee;Yoon, Jin-Ho;Park, Kyung-Soo;Hong, Myung-Hwan;Lee, Chan-Gi;Park, Jeung-Jin
    • Resources Recycling
    • /
    • v.24 no.4
    • /
    • pp.50-55
    • /
    • 2015
  • In this study, we have investigated solvent extraction of Ga and recovery of high pure Ga solution from MOCVD dust for manufacturing of LED chip. Effect of extractan, concentration of extractant were examined for choosing the more effective extractant and high pure Ga solution was fabricated by multi-stage extraction/stripping process. For extraction/separation of Ga based on the analysis of raw-material in previous study, 3 different extractants PC 99A, DP-8R, Cyanex 272 has been investigated and the extraction efficiency of 1.5 M Cyanex 272 was 43.8%. It was conformed that extraction efficiency of Ga was 83% in multi-stage extraction and 5N high purity Ga stripping solution without impurities also obtained.

Effective Treatment System for the Leachate from a Small-Scale Municipal Waste Landfill (소규모 쓰레기 매립장 침출수의 효율적인 처리 방안에 관한 연구)

  • Cho Young-Ha;Kwon Jae Hyun
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.1
    • /
    • pp.51-65
    • /
    • 2002
  • This study was carried out to apply some basic physical and chemical treatment options including Fenton's oxidation, and to evaluate the performances and the characteristics of organic and nitrogen removal using lab-scale biological treatment system such as complete-mixing activated sludge and sequencing batch reactor(SBR) processes for the treatment of leachate from a municipal waste landfill in Gyeongnam province. The results were as follows: Chemical coagulation experiments using aluminium sulfate, ferrous sulfate and ferric chloride resulted in leachate CO $D_{Cr}$ removal of 32%, 23% and 21 % with optimum reaction dose ranges of 10,000~15,000 mg/$\ell$, 1,000 mg/$\ell$ and 500~2,000 mg/$\ell$, respectively. Fenton's oxidation required the optimum conditions including pH 3.5, 6 hours of reaction time, and hydrogen peroxide and ferrous sulfate concentrations of 2,000 ~ 3,000 mg/$\ell$ each with 1:1 weight ratio to remove more than 50% of COD in the leachate containing CO $D_{Cr}$ between 2,000 ~ 3,000 mg/$\ell$. Air-stripping achieved to remove more than 97% of N $H_3$-N in the leachate in spite of requiring high cost of chemicals and extensive stripping time, and, however, zeolite treatment removing 94% of N $H_3$-N showed high selectivity to N $H^{+}$ ion and much faster removal rate than air-stripping. The result from lab-scale experiment using a complete-mixing activated sludge process showed that biological treatability tended to increase more or less as HRT increased or F/M ratio decreased, and, however, COD removal efficiency was very poor by showing only 36% at HRT of 29 days. While COD removal was achieved more during Fenton's oxidation as compared to alum treatment for the landfill leachate, the ratio of BOD/COD after Fenton's oxidation considerably increased, and the consecutive activated sludge process significantly reduced organic strength to remove 50% of CO $D_{Cr}$ and 95% of BO $D_{5}$ . The SBR process was generally more capable of removing organics and nitrogen in the leachate than complete-mixing activated sludge process to achieve 74% removal of influent CO $D_{Cr}$ , 98% of BO $D_{5}$ and especially 99% of N $H_3$-N. However, organic removal rates of the SBR processes pre-treated with air-stripping and with zeolite were not much different with those without pre-treatment, and the SBR process treated with powdered activated carbon showed a little higher rate of CO $D_{Cr}$ removal than the process without any treatment. In conclusion, the biological treatment process using SBR proved to be the most applicable for the treatment of organic contents and nitrogen simultaneously and effectively in the landfill leachate.e.

Recovery of Copper from Synthetic Leaching Solution of Manganese Nodule Matte by Solvent Extraction-electrowinning Process (망간단괴 매트상 모의 침출용액으로부터 용매추출-전해채취 공정에 의한 구리의 회수)

  • Kim, Hyun-Ho;Park, Kyung-Ho;Nam, Chul-Woo;Yoon, Ho-Sung;Kim, Min-Seuk;Kim, Chul-Joo;Park, Sang-Woon
    • Resources Recycling
    • /
    • v.25 no.1
    • /
    • pp.60-67
    • /
    • 2016
  • A scale-up test with a continuous solvent extraction and electro-winning system was carried out to separate and recover copper from a synthetic sulfuric acid solution (Cu 10.5 g/L, Co 2.0 g/L, Ni 15.0 g/L, Fe 0.2 g/L). The solution was introduced into mixer-settlers with four stages of extraction and two stages of stripping for continuous countercurrent solvent extraction to separate copper from nickel and cobalt. The loading was carried out using 40% LIX 84-I(v/v) as extractant with a phase ratio of A : O = 1 : 1. Meanwhile, the stripping was undertaken at a phase ratio of A : O = 1 : 1.5 using depleted electrolyte containing 35.0 g/L Cu and 180 g/L $H_2SO_4$ as stripping solution. The extraction and stripping efficiencies were found to be 96.7% and 91.0%, respectively. The copper composition of the stripped solution (pregnant electrolyte) was 50.0 g/L Cu with impurities of 25 ppm nickel, 5 ppm cobalt and 3 ppm iron. In the electro-winning process, copper metal of 99.833 purity was yielded with current efficiency of 98.9% and current density of $1.50A/dm^2$.

The Removal of Carbon Dioxide using AMP+HMDA in Absorption/Regeneration Continuous Process (흡수/재생 연속공정에서 AMP+HMDA를 이용한 이산화탄소의 제거)

  • Choi, Won-Joon;Cho, Ki-Chul;Oh, Kwang-Joong
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.5
    • /
    • pp.507-513
    • /
    • 2005
  • Increasing amounts of anthropogenic $CO_2$ emitted to the atmosphere are believed to be a significant factor in global climate change. Hence, the method of chemical absorption has been suggested to separate and recover acid gases such as $CO_2$. In this study, the characteristics of absorption and regeneration of $CO_2$ for the absorbent which adding HMDA (hexamethylenediamine) into AMP (2-amino-2-methyl-1-propanol), hindered amine, was investigated in lab-scale absorption/regeneration reactor. As a result of this study, the removal efficiency of $CO_2$ increased when adding $5.9\%,\;11.7\%\;and\;23.4\%$ HMDA into $30\%$ AMP respectively. Also, the removal efficiency of $CO_2$ increased $6.5\%,\;8.4\%,\;10.3\%$ respectively as compared to AMP alone when the gas flow rate was 7.5 SL/min. In addition, all absorbents used in the study revealed the high stripping efficiency, which was almost $99\%$, at the temperature of $110^{\circ}C$. Thus, the regeneration tower should be operated at $110^{\circ}C$. At this time, the concentration of exhausted $CO_2$ was higher than $99\%$.

Emulsion liquid membranes for cadmium removal: Studies of extraction efficiency

  • Ahmad, A.L.;Kusumastuti, Adhi;Derek, C.J.C.;Ooi, B.S.
    • Membrane and Water Treatment
    • /
    • v.4 no.1
    • /
    • pp.11-25
    • /
    • 2013
  • Emulsion liquid membrane (ELM) process suffers from emulsion instability problem. So far, emulsion produced by mechanical methods such as stirrer and homogenizer has big size and high emulsion breakage. This paper discussed the application of emulsion produced by sonicator to extract cadmium in a batch ELM system. The emulsions consist of N,N-Dioctyl-1-octanamine (trioctylamine/TOA), nitrogen trihydride (ammonia/NH4OH), sorbitan monooleate (Span 80), and kerosene as carrier, stripping solution, emulsifying agent, and organic diluent, respectively. Effects of comprehensive parameters on extraction efficiency of Cd(II) such as emulsification time, extraction time, stirring speed, surfactant concentration, initial feed phase concentration, carrier concentration, volume ratio of the emulsion to feed phase, and pH of initial feed phase were evaluated. The results showed that extraction efficiencies of Cd(II) greater than 98% could be obtained under the following conditions: 15 minutes of emulsification time, 4 wt.% of Span 80 concentration, 4 wt.% of TOA concentration, 15 minutes of extraction time, 250 rpm of stirring speed, 100 ppm of initial feed concentration, volume ratio of emulsion to feed phase of 1:5, and initial feed pH of 1.53.

In-situ Methane Enrichment System Coupled with External $CO_2$ Stripper in Mesophilic Anaerobic Digestion (중온혐기성소화조에서 외부 $CO_2$ Stripping을 이용한 In-situ 고순도 메탄회수 공정 개발)

  • Kang, Ho;Jeong, Ji-Hyun;Lim, Seon-Ae;Lee, Hye-Mi
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.3
    • /
    • pp.155-161
    • /
    • 2012
  • A simple in-situ methane enrichment system in mesophilic anaerobic digestion was developed to take advantage of the differing solubilities of $CO_2$ and methane. The methane enhancement systems consisted of low solids plug-flow maize digester coupled with a leachate recycle loop to an external $CO_2$ stripper. The effects of leachate recycle rate (LRR) and reactor alkalinity on the resulting offgas $CH_4$ contents, biogas productivity and TVS removal efficiency were quantitively evaluated. The results showed that offgas $CH_4$ contents of over 94% was achieved at 3 volume of leachate recycle per volume of reactor per day (3 v/v-d) and at the reactor alkalinity of 4 g/L as $CaCO_3$, as the optimum operating conditions. The TVS removal efficiency of the methane enhancement system was 79% which corresponds to 94% of the control reactor and the methane productivity appeared to be 0.71 v/v-d. Offgas methane contents correlated well with LRR. However excessively high LRR led to the decrease in TVS removal efficiency.

Electrorefining Characteristics of Uranium by Using a Graphite Cathode (흑연 전극을 이용한 우라늄 전해정련 특성)

  • Kang, Young-Ho;Lee, Jong-Hyeon;Hwang, Sung-Chan;Shim, Joon-Bo;Kim, Eung-Ho
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.5 no.1
    • /
    • pp.1-7
    • /
    • 2007
  • Electrorefining experiments were successfully carried out in LiCl-KCl eutectic molten salt with a graphite cathode. It was found that the formation of Uranium-Graphite intercalation compound(U-GIC) helped the self-scraping mechanism of the uranium dendrite and the efficiency of the electrorefiner increased due to an elimination of the stripping step. The contaminations of the uranium deposit by rare earth elements was negligible while about 300 ppm of carbon was observed. The carbon contamination is believed to be eliminated by further purification by yttrium reaction. The morphology characteristics of the recovered U deposit was compared to that of steel cathode. These are only qualitative preliminary experimental results, but we believe that further research on this type of activity change the direction of the electrorefining research on spent nuclear fuel.

  • PDF

A Study on the Extraction of Alkaline Protease from Bacillus licheniformis Fermentation Broth using Reverse Micelle (역미셀을 이용한 Bacillus licheniformis 발효액으로 부터 알카리성 단백질 분해효소의 추출에 관한 연구)

  • 권성필;구윤모홍성안
    • KSBB Journal
    • /
    • v.6 no.1
    • /
    • pp.105-109
    • /
    • 1991
  • In separating alkaline protease from the bacteria (Bacillus licheniformis) fermentation broth using reverse micelle, effects of various factors;ionic strength, pH and surfactant concentration, on separation efficiency were studied. KCl controls the ionic strength. The lower KCl concentration was in the feed solution, the more protein and activity was recovered. The higher KCl concentration was in the stripping solution, the more protein and activity was recovered. Using sodium-di-2-ethylhexyl sulfosuccinate(Aerosol-OT or AOT) as a surfactant, the higher AOT concentration in the solvent, the more activity and protein were recovered. 0.1N NaOH and IN HCl were used to adjust pH. Maximum recovery of protein mass and activity were obtained at feed solution of pH 5.3. Maximum activity was recovered at stripping solution of pH 7.5

  • PDF

Recycling of rayon industry effluent for the recovery and separation of Zn/Ca using Thiophosphinic extractant

  • Jha, M.K.;Kumar, V.;Bagchi, D.;Singh, R.J.;Lee, Jae-Chun
    • Proceedings of the Korean Institute of Resources Recycling Conference
    • /
    • 2006.05a
    • /
    • pp.78-85
    • /
    • 2006
  • In textile industries, waste effluent containing zinc is generated during the manufacture of rayon yarn from the wood pulp or cotton linters. Due to the strict environmental regulations and the presence of toxic metallic and other constituents, the discharge of industrial effluents in the sewage or disposal of solid sludge as landfill is restricted. Before recycling of zinc as zinc sulphate solution to the spinning-bath of the rayon manufacturing plant the zinc sulphate solution must be free from calcium, which is deleterious to the process as gypsum precipitates with the increase in concentration and forms scale in the bath. In the present work an attempt has been made to develop a process following solvent extraction technique using thiophosphinic extractants, Cyanex 272 and 302 modified with isodecanol and diluted in kerosene to recover zinc from rayon effluent. Various process parameters viz. extraction of zinc from different concentration of solution, distribution ratio, selective extraction, O/A ratio on extraction and stripping from the loaded organic, complex formation in the organic phase etc. have been studied to see the feasibility of the process. The extractant Cyanex 302 has been found selective for the recovery of 99.99% of zinc from the effluent above equilibrium pH 3.4 maintaining the O/A ratio of 1/30 leaving all the calcium in the raffinate. It selectively extracted zinc in the form of complex $[R_{2}Zn.3RH]_{org}$ and retained all the calcium in the aqueous raffinate. The zinc from the loaded Cyanex 302 can be stripped with 10% sulphuric acid at even O/A ratio of 10 without affecting the stripping efficiency. The stripped solution thus obtained could be recycled in the spinning bath of the rayon plant. The raffinate obtained after the recovery of zinc could be disposed safely without affacting environment.

  • PDF