• Title/Summary/Keyword: Stress wave test

Search Result 224, Processing Time 0.022 seconds

Accelerated Life Testing and Validity Evaluation of Finger Strips Used for Electromagnetic Shielding Doors (전자파 차폐 도어용 핑거 스트립의 가속수명시험 및 유효성 평가)

  • Lee, Joo Hong;Kim, Do Sik;Chang, Mu Seong;Cho, Hae Yong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.9
    • /
    • pp.831-837
    • /
    • 2015
  • Many persons and electronic devices are exposed to electromagnetic (EM) waves generated from magnetic resonance imaging (MRI) equipment, EM pulses (EMPs), and many other kinds of EM wave devices. Finger strips are used to provide shielding from these EM waves. Because of the high thermal conductivity of finger strips, they are used in the design of specialized doors that are installed in shielded rooms. In this study, we perform an accelerated life test using the load acceleration stress, which affects the main failure mode of finger strips. We predict the life of the finger strip under normal usage conditions based on the results of the accelerated life test. We compare the results with those predicted from the life test under normal usage conditions to evaluate the validity of accelerated life testing.

Evaluation of Dynamic Rock Stiffness Using In-hole Seismic Technique (인홀 탄성파 시험을 이용한 암반의 동적 강성 평가)

  • Sun Chang-Guk;Kang Byung-Soo;Kim Young-Su;Mok Young-Jin
    • The Journal of Engineering Geology
    • /
    • v.15 no.3
    • /
    • pp.309-323
    • /
    • 2005
  • Dynamic stiffness of subsurface materials is one of the most important geotechnical parameters in predicting deformational behavior of structures as well as practicing seismic design and performance evaluation. In an effort to measure the parameter efficiently and accurately, various borehole seismic testing techniques have been, thus, developed and used during past several decades. Moreover, recent rush of underground-space projects and increasing size of structures put more stress on reliable site investigation techniques in estimating stiffness of rock mass. In this paper, a new technique called 'in-hole seismic test' has been implemented to measure the dynamic stiffness of rock masses at subsurface foundations and tunnel-faces. The reliance of in-hole seismic test was evaluated by comparing the testing results at several rock sites with those of other borehole techniques and the technique tunnls out to be an efficient and accurate in-situ testing technique.

Development of an Ultra-Slim System in Package (SiP)

  • Gao, Shan;Hong, Ju-Pyo;Kim, Jin-Su;Yoo, Do-Jae;Jeong, Tae-Sung;Choi, Seog-Moon;Yi, Sung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.15 no.1
    • /
    • pp.7-18
    • /
    • 2008
  • This paper reviews the current development of an ultra-slim SiP for Radio Frequency (RF) application, in which three flip chips, additional passive components and Surface Acoustic Wave (SAW) filters are integrated side-by-side. A systematic investigation is carried out for the design optimization, process and reliability improvement of the package, which comprises several aspects: a design study based on the 3D thermo-mechanical finite element analysis of the packaging, the determination of stress, warpage distribution, critical failure zones, and the figuration of the effects of material properties, process conditions on the reliability of package. The optimized material sets for manufacturing process were determined which can reduce the number of testing samples from 75 to 2. In addition the molded underfilling (MUF) process is proposed which not only saves one manufacturing process, but also improves the thermo-mechanical performance of the package compared with conventional epoxy underfilling process. In the end, JEDEC's moisture sensitivity test, thermal cycle test and pressure cooker tests have also been carried out for reliability evaluation. The test results show that the optimized ultra-slim SiP has a good reliability performance.

  • PDF

A Study of Engineering Properties of Rock Mass Weathered by Sea water (해수에 의한 암반 풍화의 공학적 특성 연구)

  • Choi Kang-Il;Kang Coo-Won;Go Chin-Surk
    • Explosives and Blasting
    • /
    • v.23 no.1
    • /
    • pp.9-17
    • /
    • 2005
  • This study is to clarify the comparative relationship and mechanical anisotropy of granite distributed in the Nam-weon on the subject of weathered rock mass sea water surroundings. Artificial weathering test is defined as a test, which controls the weathering rate and agents by controlling the weathering rate and agents by artificial environmental of salt water. Increased weathering degree is large indicated by weathering salt water, such as apparent specific gravity, absorption, porosity, uniaxial compression strength, P-wave velocity, slake durability, shore hardness, indirect tensile strength(brazilian test) and cohesion were measured. As the Weathering salt water proceeds, cracks develope increasingly. A number the cracks affect the rock deformation. Therefore, stress-strain curve of weathered salt water rock in one confined state are quite differ from weathered fresh water rock those. A reason of their deformation type is the formation of micro-cracks and potential porosity caused by artificial weathering test.

Experimental Investigation of Working Fracture in Silicon Steel Strip Occurring Due to Change in Roll-Gap Profile in Cold Rolling (실리콘 강판 냉간압연 중 발생하는 롤갭 형상변화에 의한 가공파손에 관한 실험적 분석)

  • Byon, Sang-Min;Lee, Jae-Hyeon;Kim, Sang-Rok;Choi, Hyeon-Sik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.9
    • /
    • pp.1299-1304
    • /
    • 2010
  • We examined the working fracture behavior of a silicon-steel strip caused by deformation deviation by performing a pilot rolling test. The deformation deviation resulted in the edges (or center portion) of the strip being stretched and the other parts being compressed in the rolling direction; this was because of different degrees of deformation in these parts. We designed roll grooves shape to reflect the role of roll bending, which generates waviness in the strip in an actual cold rolling process, into the pilot rolling test. The material used in the rolling test was highsilicon steel (about 3%). The results of the test showed that the type of fracture in the strip specimen varied with the magnitude of the deformation deviation. The tensile stress produced at the strip edges because of the center waviness in the rolling direction was a crucial factor that resulted in edge cracking and a zigzag-shaped fracture at the center.

A STUDY ON THE FRACTURE TOUGHNESS OF DENTAL COMPOSITE RESINS (치과용 복합레진의 파괴인성에 관한 실험적 연구)

  • Park, Jin-Hoon;Min, Byung-Soon;Choi, Ho-Young;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.15 no.2
    • /
    • pp.17-33
    • /
    • 1990
  • The purpose of this study was to evaluate the fracture toughness of dental composite resins and to investigate the filler factor affecting the fracture behaviour on which the degree of fracture toughness depends. Six kinds of commercially available composite resin;, including two of each macrofilled, microfilled, and hybrid type were used for this study, The plane strain fracture toughness ($K_{10}$) was determined by three-point bending test using the single edge notch specimen according to the ASTM-E399. The specimens were fabricated with visible light curing or self curing of each composite resin previously inserted into a metal mold, and three-point bending test was conducted with cross-head speed of 0.1mm/min following a day's storage of the specimens in $37^{\circ}C$ distilled water. The filler volume fractions were determined by the standard ashing test according to the ISO-4049. Acoustic Emission(AE), a nondestructive testing method detecting the elastic wave released from the localized sources In material under a certain stress, was detected during three-point bending test and its analyzed data was compared with, canning electron fractographs of each specimen. The results were as follows : 1. The filler content of composite resin material was found to be highest in the hybrid type followed by the macrofilled type, and the microfilled type. 2. It was found that the value of plane strain fracture toughness of composite resin material was in the range from 0.69 MPa$\sqrt{m}$ to 1 46 MPa$\sqrt{m}$ and highest In the macrofilled type followed by the hybrid type, and the microfilled type. 3. The consequence of Acoustic Emission analysis revealed that the plane strain fracture toughness increased according as the count of Acoustic Emission events increased. 4. The higher the plane strain fracture toughness became, the higher degree of surface roughness and irregularity the fractographs demonstrated.

  • PDF

Thermal Environment Transition of Response Climate Change and Heat Wave Application Evaporative Cooling System (기후변화 및 폭염대응 증발냉각시스템 적용에 따른 내·외부 열환경 변화 연구)

  • Kim, Jeong-Ho;Kim, Hak-Gi;Yoon, Yong-Han;Kwon, Ki-Uk
    • Journal of Environmental Science International
    • /
    • v.25 no.9
    • /
    • pp.1269-1281
    • /
    • 2016
  • This study evaporative cooling system a heat wave climate change and reduction of the inside and outside thermal environment change research. Measurement items included micro meteorological phenomena and measured comfort indices. A micro meteorograph of temperature, relative humidity, surface temperature, and the comfort indices of WBGT, UTCI, and PMV were measured. The difference in inside and outside temperatures were compared for different land types, with the largest difference found in Type A ($4.81^{\circ}C$), followed by Type B ($4.40^{\circ}C$) and Type C ($3.12^{\circ}C$). Relative humidity was about 10.43% higher inside due to water injection by the evaporative cooling system. Surface temperature was inside about $6.60^{\circ}C$ higher than the outside all types. WBGT were Type A ($3.50^{\circ}C$) > Type B ($2.71^{\circ}C$) > Type C ($1.88^{\circ}C$). UTCI was low heat stress inside than outside all types. PMV was analysed Type C for inside predicted percentage of dissatisfied 75%, other types was percentage of dissatisfied 100% by inside and outside. Correlation analysis between land cover type and temperature, surface temperature, pmv, utci. T-test analysed inside and outside temperature difference was significant in all types of land.

Evaluation of Consolidation Properties in Soft Soils Using Elastic and Electromagnetic Waves (전단파와 전자기파를 이용한 연약 지반의 실내 압밀 특성 평가)

  • Lee, Chang-Ho;Yoon, Hyung-Koo;Kim, Joon-Han;Lee, Jong-Sub
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.8
    • /
    • pp.25-34
    • /
    • 2008
  • A new hybrid oedometer cell is designed and manufactured to investigate a behavior of soft soils by using elastic and electromagnetic waves during consolidation test. Bender elements, which generate and detect shear waves, are placed in the top cap and the bottom plate and mounted on the oedometer wall. Double wedge type electrical resistance probe, which measures local void ratio change, is positioned onto the top cap of the oedometer cell. The bender elements and the electrical resistance probe are anchored into a nylon set screw with epoxy resin. The nylon set screw with epoxy resin minimizes directly transmited elastic waves through the oedometer cell due to impedence mismatch and allows for easy replacement of defected bender elements and electrical resistance probe. Primary consolidation time can be estimated from the slope of electrical resistance versus log time curve and the evolution of shear wave velocity. The shear wave velocity can be used to assess inherent anisotropy when disturbance effects are minimized because particle alignment affects the shear wave velocity. The void ratios evaluated by the electrical resistance probe are similar to those by the settlement during consolidation. This study suggests that the shear wave velocity and the electrical resistance can provide complementary imformations to understand consolidation characteristics such as primary consolidation, anisotropy, and void ratio.

Reliability Analysis and Fatigue Models of Concrete under Flexural or Split Tensional Cyclic Loadings (휨 또는 쪼갬인장 반복하중을 받는 콘크리트의 신뢰성 해석과 피로모델 제안)

  • Kim Dong-Ho;Sim Do-Sik;Kim Sung-Hwan;Yun Kyong-Ku
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.5 s.83
    • /
    • pp.581-589
    • /
    • 2004
  • This paper compares the fatigue behaviors of concretes subjected to flexural and split-tensional loadings, and proposes the fatigue reliability models based on experimental results and reliability analysis. The fatigue tests were performed for the specimens of $150 mm{\times}75 mm$ split tensional cylinders and $150 mm{\times}150 mm{\times}550 mm$ flexural beams under constant loadings at three levels (70, 80 and $90\%$) with 0.1 stress ratio, 20 Hz loading speed and sine wave. The reliability analysis on fatigue data was based on Weibull distribution of two-parameters. From fatigue test results, two criteria were proposed to reject the experimental fatigue data because of statistical variation of concrete fatigue data. Two parameters ($\alpha$and u) of Weibull distribution were obtained using graphical method, moment method and maximum likelihood method. The probability density function(P.D.F) and cumulative distribution function(C.D.F) of the Weibull distribution for fatigue life of pavement concrete were derived for various stress levels using parameters, $\alpha$ and u. The goodness-of-fit test by Kolmogorov-Smirnov test was acceptable at $5\%$ level of significance. Based on reliability analysis, a fatigue model for pavement concrete was proposed and compared from existing models.

Design and Fabrication of Split Hopkinson Pressure Bar for Dynamic Mechanical Properties of Self-reinforced Polypropylene Composite (폴리프로필렌 자기 보강 복합재의 동적 물성 구축을 위한 Split Hopkinson Pressure Bar의 설계 및 제작)

  • Kang, So-Young;Kim, Do-Hyoung;Kim, Dong-Hyun;Kim, Hak-Sung
    • Composites Research
    • /
    • v.31 no.5
    • /
    • pp.221-226
    • /
    • 2018
  • The Split Hopkinson Pressure Bar(SHPB) has been the most widely used apparatus to characterize dynamic mechanical behavior of materials at high strain rates between $100s^{-1}$ and $10,000s^{-1}$. The SHPB test is based on the wave propagation theory which was developed to give the stress, strain and strain rate in the specimen using the strains measured in the incident and transmission bars. In this study, the SHPB was directly designed and fabricated for the dynamic mechanical properties of fiber reinforced plastic (FRP) composites. In addition, this apparatus was verified for the validity by comparing the strain data obtained through the high speed camera and Digital Image Correlation(DIC) during the high strain rate compression test of the self-reinforced polypropylene composite (SRPP) specimen.