• Title/Summary/Keyword: Stress Acceleration

Search Result 375, Processing Time 0.031 seconds

Acceleration Life Prediction of the Capacitor on a Traction Inverter for a High-Speed Train (고속철도차량용 견인 인버터 커패시터의 가속수명 예측)

  • Maeng, Heeyoung;Jung, Si-Kyo
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.24 no.6
    • /
    • pp.653-659
    • /
    • 2015
  • The aim of this study is to develop a technique for the accelerated life test of the capacitor in a propulsion control device of a traction inverter used for a high-speed train. Using this technique, the accelerated life test can possibly estimate the life cycle of a capacitor under various temperature conditions and irregularly applied voltage. The accelerated life test is conducted for the capacitor of the traction inverter. The common proceedings of this test are selection of failure mechanism, determination of accelerated stress, range determination of the accelerated stress, determination of the test condition, and distribution and determination of the sample. From this result, the continuous applied voltage was not considered for the acceleration factors anymore. Therefore, the final result having an acceleration factor of 9.4 (= 13,626/1,445) was observed. Furthermore, the life-shortening acceleration effect for the irregular applied voltage condition can be applied to various situations.

Investigation into the Worst Stress Condition for an Accelerated Life Test of a Compressor in Refrigerators - Acceleration Factor and the Reducible Test Time under High Temperature - (냉장고용 압축기의 가속수명시험을 위한 가혹조건 탐색 - 고온 가혹조건에서의 가속계수와 단축 시험기간 -)

  • Jung, Y.M.;Joo, W.J.;Jeong, S.K.
    • Journal of Power System Engineering
    • /
    • v.16 no.3
    • /
    • pp.44-50
    • /
    • 2012
  • The reliability qualification test is essential in order to ensure the life time of the product under the normal operation conditions when a new product is developed. The reliability qualification test period has an important impact on the development time of new product. Therefore, some researches to reduce the test time of reliability qualification test have been actively studied. Generally, accelerated life test is well known as one method that can save the test time of the reliability qualification test. This test is conducted under the higher stress condition than normal condition. So we need to investigate what factor affects to the higher stress condition. This paper shows the relationship between the acceleration factor and reliability qualification test period. Especially, we focused on the method to obtain effective acceleration factors under the high temperature condition. Through some experiments for a refrigerator's compressor, we were able to confirm how to increase acceleration factors and how to reduce the reliability qualification test period with minimum samples.

The effects of high sustained +Gz under different seat back angles (조종석 각도변화가 양성 가속도에 미치는 영향에 관한 연구)

  • 이창민;박세권
    • Journal of the Ergonomics Society of Korea
    • /
    • v.15 no.1
    • /
    • pp.69-78
    • /
    • 1996
  • Current fighter pilots, flying new generation aircrafts with high performance, are under severe stress during aerial combat maneuvering when they are exposed to high sustained +Gz(Head-to-foot) acceleration stress. Two major factor limiting performance during high sustaied +Gz acceleration stress are loss of vision-greyout or blackout, and loss of consciousness (LOC). These symptoms are believed to occur as a result of insuff- icient blood flow to the retina and the brain. This study was conducted to evaluate the effects of high sustained +Gz stress under different seat back angle. The results. obtained by the biodvanmic computer simulations using the ATB(articulated total body) model, are represented with respect to three variables, such as HIC(head injury criterion) value, average G, and maximum G. The results demonstrate that the seat back angle(over $30^{\circ}C$) had a significant effect to decrease +Gz stress on the head segment and had no significant effect on HIC.

  • PDF

Suggested Accelerated Life Test Method of SMPS for Outdoor Lighting LED (실외조명 LED용 SMPS의 가속수명시험법 제안)

  • Lim, Seong-Yong;Hyong, Jae-Phill;Lim, Hong-Woo;Oh, Geun-Tae
    • Journal of Applied Reliability
    • /
    • v.18 no.1
    • /
    • pp.8-19
    • /
    • 2018
  • Purpose: This study has developed the accelerated lifetime test method for smps for outdoor lighting LED through two factors of temperature and humidity. Methods: Acceleration condition was confirmed for each stress and model, and acceleration life test model was estimated according to acceleration condition. Results: As a result of confirming the accelerated life test model, in the case of humidity, acceleration was established only in the foreign products. Therefore, it is confirmed that the acceleration condition is insufficient. However, the estimated parameters for temperature are relatively constant. It is therefore suitable for power supply acceleration tests for outdoor lighting LEDs. Conclusion: The SMPS acceleration test for outdoor lighting LED can improve the availability of the product by developing an accelerated life test method that guarantees the reliability of the product.

Accelerated Degradation Stress of High Power Phosphor Converted LED Package (형광체 변환 고출력 백색 LED 패키지의 가속 열화 스트레스)

  • Chan, Sung-Il;Jang, Joong-Soon
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.17 no.4
    • /
    • pp.19-26
    • /
    • 2010
  • We found that saturated water vapor pressure is the most dominant stress factor for the degradation phenomenon in the package for high-power phosphor-converted white light emitting diode (high power LED). Also, we proved that saturated water vapor pressure is effective acceleration stress of LED package degradation from an acceleration life test. Test conditions were $121^{\circ}C$, 100% R.H., and max. 168 h storage with and without 350 mA. The accelerating tests in both conditions cause optical power loss, reduction of spectrum intensity, device leakage current, and thermal resistance in the package. Also, dark brown color and pore induced by hygro-mechanical stress partially contribute to the degradation of LED package. From these results, we have known that the saturated water vapor pressure stress is adequate as the acceleration stress for shortening life test time of LED packages.

Study on Acceleration Factor Model with Accelerated Stress Interactions (가속 스트레스의 교호작용을 고려한 가속계수 모델에 대한 연구)

  • Kim, Hyoung-Eui;Kang, Bo-Sik;Cho, You-Hee
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.7
    • /
    • pp.751-757
    • /
    • 2012
  • An accelerated life test (ALT) is a test method that forces components to fail more quickly than they would under use conditions by applying higher overstresses. When two or more accelerating stresses are involved in an ALT, an interaction effect may occur. In previous studies, mostly ALTs without considering an interaction of accelerated stresses and accelerated life models were proposed. The life data obtained are extrapolated using a life-stress relationship to estimate the life distribution at use conditions. We use the general log-linear relationship to model the dependence of life in the Weibull distribution on stress. Therefore, this study suggests the acceleration factor model between the lives at use conditions and accelerated conditions by using mechanical component life data considering an interaction effect. Further, the accelerated life test method and acceleration factor model proposed in this paper will be the basis for adopting an accelerated life test with accelerated stress interactions.

Analysis of Diffuse Brain Injury due to Accelerations (가속도에 의한 뇌의 미만성 부상에 관한 연구)

  • Nam, D.H.;Kim, Y.E.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.213-217
    • /
    • 1997
  • In this study, three-dimensional inite element model was developed and analyzed or DAI using ABAQUS. To verify the developed FE model, simulated results were compared to experimental results of human cadaver by Nahum et. al. (1977). The effect of acceleration pattern and accelerating duration time or DAI was analyzed by means of maximum shear stress and pressure distribution. DAI was favored or angular acceleration rather than linear acceleration, and occured in brain stem, pons and midbrain easily as accelerating duration time was increased.

  • PDF

A Study on Accelerated Photo-Degradation Test for Lifetime Estimation of Ink-jet Ink (잉크젯 잉크의 수명예측을 위한 광열화 가속시험법에 관한 연구)

  • Koo, Hyun-Jin;Cho, Hang-Won;Ji, Byung-Chul
    • Journal of Applied Reliability
    • /
    • v.15 no.3
    • /
    • pp.154-162
    • /
    • 2015
  • We have performed accelerated photo-degradation test using a 10-Sun level high irradiance $Weather-Ometer^{(R)}$ (10-Sun Ci5000) in an attempt to study acceleration and correlation between accelerated and service conditions for ink-jet ink. The accelerated test was used to predict lifetimes of ink-jet ink through the calculation of scaling factor for intensity of irradiance and duration of usage combined with estimation of lifetime distribution and inverse power model as a life-stress model. The lifetimes and acceleration factors for foreign and domestic inks were compared with each other. The results showed that the failure mechanisms and life-stress models for ink-jet ink were different among the color of ink which means that we might be in need of further study by color of inks.

The Study on the High Acceleration Life Test Method for the Automotive Electric and Electronic Parts (자동차 전장부품의 초 가속 실뇌성 수명시험 방법에 관한 연구)

  • Lee, Jong-Beom;Cho, Jai-Rip
    • Journal of Korean Society for Quality Management
    • /
    • v.28 no.4
    • /
    • pp.16-28
    • /
    • 2000
  • Recently days, High Accelerated Life Test of electrical and electronic parts is increasing its importance. This study set the hypothesis to develop the method that was analysis and application of HALT for the automotive electrical and electronic parts, it used Arrhenius's Model and Eyring's Model, and ESS theory. Validity of application is proved by other test data. Especially, this study emphasis on utility of acceleration to temperature, humidity, voltage, mechanical stress and other stress. In this study set the pattem of practical application. Therefore, this study emphasis on the application of the HALT and the use of other parameter by acceleration reliability test data. The result of this study is as follows. 1) There is relationship between molar weight and material constant. 2) Characteristic of material is operating acceleration factor as well as parts failure factors. Of course, according to the characteristic of material, activation energy is often more important than molar weight. But it will be defined by more testing and improvements in practical application.

  • PDF

A Study on the Measurement of the Pipeline Displacement Vibration Using Accelerometers (가속도계를 이용한 배관 변위 진동 계측에 관한 연구)

  • Suh, Jin Sung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.6
    • /
    • pp.476-482
    • /
    • 2014
  • The stress analysis of the pipeline is required in any kind of plant for its safe operation. For this, the displacement vibration data measured at many locations of the pipeline should be provided. In reality, the installation of the non-contact type displacement sensors such as laser displacement sensors or eddy current type proximity sensors in a narrow and confined region in the vicinity of the pipeline is almost impracticable. In this work, the general purpose piezo-ceramic accelerometers were attached on the measuring points on the pipeline and the acceleration vibration signal was acquired. The measured acceleration signal was low pass filtered and then downsampled. The resulting acceleration signal was transformed into both the time-domain and frequency-domain displacement signal utilizing the fast Fourier transform techniques. All the procedures are presented in detail. It is demonstrated that the measurement of the pipeline acceleration by using contact type accelerometers can be made for the purpose of providing the required displacement data for the stress analysis of the pipeline.