• 제목/요약/키워드: Strength development factor

검색결과 324건 처리시간 0.029초

초기 고온이력이 시멘트 모르터의 강도발현에 미치는 영향에 관한 연구 (An Experimental Study on the Characteristics of Compressive Strength in Cement Mortar under High Temperature conditions in an Early Age)

  • 김영주;최맹기;공민호;박희곤;김광기;정상진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2005년도 춘계 학술기술논문발표대회 논문집
    • /
    • pp.45-48
    • /
    • 2005
  • This study is basic experiment for estimating influence of strength by curing temperature of concrete's heat of hydration and estimate relationship of compressive strength development by initial curing temperature factor, and then asume temperature factor which influence compressive strength development and for showing basic document of qualify control. According to the result of cement mortar by the curing temperature factor high-curing temperature shows high strength on 3 day compare with low curing-temperature, shows higher strength than the piece of high curing temperature.

  • PDF

고온이력이 콘크리트의 강도발현에 미치는 영향에 관한 실험적 연구 (An Experimental Study on the Effects of High temperature Hysteresis on Concrete Strength Development)

  • 김학영;민홍준;장형준;공민호;안무영;정상진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계 학술발표회 논문집(II)
    • /
    • pp.433-436
    • /
    • 2006
  • This study is basic experiment for estimating influence of strength by curing temperature of concrete's heat of hydration and estimate relationship of compressive strength development by initial curing temperature factor, and then asume temperature factor which influence compressive strength development and for showing basic document of quality control. According to the result of managerial test pieces by the curing temperature factor high-curing temperature shows high strength on 3 day compare with low curing-temperature, shows higher strength than the piece of high curing temperature.

  • PDF

초기 고온이력을 받은 시멘트 모르타르의 강도 특성에 관한 실험적 연구 (An Experimental Study on the Characteristics of Strength in Mortar under High Temperature conditions in an Early Age)

  • 김영주;김한식;공민호;김제섭;이영도;정상진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(II)
    • /
    • pp.517-520
    • /
    • 2005
  • This study is basic experiment for estimating influence of strength by curing temperature of concrete's heat of hydration and estimate relationship of compressive strength development by initial curing temperature factor, and then asume temperature factor which influence compressive strength development and for showing basic document of quality control. According to the result of cement mortar by the curing temperature factor high-curing temperature shows high strength on 3 day compare with low curing-temperature, shows higher strength than the piece of high curing temperature.

  • PDF

모르터 압축강도 특성에 영향을 미치는 고온이력에 관한 실험적 연구 (An Experimental Study on the Characteristics of Strength in Mortar under High Temperature conditions in an Early Age)

  • 김영주;공민호;송인명;양동일;백민수;정상진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.703-706
    • /
    • 2004
  • This study is basic experiment for estimating influence of strength by curing temperature of concrete's heat of hydration and estimate relationship of compressive strength development by initial curing temperature factor, and then asume temperature factor which influence compressive strength development and for showing basic document of quality control. According to the result of cement mortar by the curing temperature factor high-curing temperature shows high strength on 3 day compare with low curing-temperature, shows higher strength than the piece of high curing temperature.

  • PDF

복합재 추진기관의 확률적 구조 설계 기법 (A Probabilistic Structural Design Method of Composite Propulsion System)

  • 황태경;김형근;김성은
    • 한국추진공학회지
    • /
    • 제17권5호
    • /
    • pp.80-85
    • /
    • 2013
  • 본 논문은 평균값과 Allowable 값 기준의 구조 안전율과 구조 신뢰도와 관계 비교를 통해 복합재 추진기관의 확률적 구조 설계 방법을 설명하였다. 일반적으로 복합재 압력용기의 평균 값 기준의 구조설계는 1.5 이상의 구조 안전율과 0.999 이상의 구조 신뢰도 값이 요구된다. 요구 압력 기준의 0.999의 구조 신뢰도를 만족하기 위해서 평균 값 기준의 구조설계는 섬유 강도의 변동률에 따라 다른 구조 안전율을 부여해야한다. 그러나 이미 섬유 강도 변동률이 고려된 Allowable 값을 이용할 때는 고정된 안전율이 부여된다. 이상의 해석 결과로 볼 때 섬유 강도는 복합재 압력용기 구조 설계에 가장 중요한 설계 변수이고, 우수한 성능의 복합재 추진기관을 개발하기 위해서는 섬유 강도의 변동률이 최소화되어야 함을 알 수 있었다.

고강도 콘크리트의 취도계수에 관한 실험적 연구 (An experimental study on the fragility factor of high strength concrete)

  • 김희두;양성환
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.148-149
    • /
    • 2014
  • In modern society, population overcrowding and concentration of facilities are happened because of the concentration on to city. So this phenomenon demands improvement of material's performance, technical development of structure analysis and design and improvement of constructing ability .High strength concrete has some merits. High strengthening makes the cross section reduced, and that cause decrease of structure weight. And using high durable and superplasticizer promote liquidity, thus high quality concrete can be produced. Because of these advantages, this study is for showing validity of using it by compression/tensile strength experiment. As this experiment's result, when concrete become stronger, interface intensity coefficient between cement and aggregate is different and they don't adhere to each other. So there is brittle failure. Fragility factor also steadily increase with strong concrete, it tells high strength concrete has problem. Therefore the sources used in high strength concrete like cement and aggregate must have great quality. So the source's performance must be supervised well because their quality decides performance criteria.

  • PDF

고강도철근(550MPa)의 원전구조물 적용을 위한 직선철근의 정착설계 (Development Length of High-Strength Straight Bars (550MPa) in Nuclear Power Plant Structures)

  • 이병수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 추계 학술논문 발표대회
    • /
    • pp.110-111
    • /
    • 2018
  • Because of the congestion problems, the high-strength reinforcements are expected to be used in nuclear power plant structures in the near future. According to ACI 349-13, it is permitted to use the high-strength(550MPa) straight bars in design of development length, but there is no special equation for high-strength bars. In order to reflect the anchorage capacity and behavior properties of high-strength straight bars with large-diameter(43 & 57mm), it is necessary to find the modified factor or develop the new development length equation for large-size and high-strength bars.

  • PDF

혼화재 종류 변화에 따른 저온조건하 콘크리트의 초기강도 발현 특성 (Strength Development of the Concrete at Early Age subjected to Low Temperature depending on Admixture Types)

  • 한민철
    • 한국건축시공학회지
    • /
    • 제7권4호
    • /
    • pp.145-151
    • /
    • 2007
  • In this paper, tests are carried out in order to investigate the strength development of concrete under various binder types, W/B and curing temperature ranged from $5{\sim}20^{\circ}C$. Fly ash and blast furnace slag were incorporated by as much as 30%, respectively. Strength development of concrete are estimated using Logistic model and strength ratio of concrete at 28days to that at early age are also investigated. According to experimental results, it is found that good agreements are obtained between measured values and calculated ones using logistic model below $20^{\circ}C$. Strength ratio of concrete at 28days to that at early age increases in case W/B decreases and curing temperature increases. Tables and graphs for strength ratio of concrete are provided in this paper. It is capable of obtaining and predicting the periods to attain design strength by considering increment factor of strength easily with the table and graphs presented in this paper. This paper presents the reference data to decide removal time of form, time to reach target strength and strength inspection of remicon whether the test specimens meet the specified criteria of compressive strength. Multi regression models with respect to the relationship between 7days compressive strength and 28 days compressive strength depending on W/B and admixture types are presented.

고강도 콘크리트 휨부재의 정착 및 겹침이음길이에 관한 실험적 연구 (Experimental Research on Development and Splices Length in High-Strength Concrete Flexural Members)

  • 이기열;김우;정기오
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.865-871
    • /
    • 2003
  • This paper presents the test results of 24 beam-end specimens to investigate the effect of concrete strength and cover thickness on the development resistance capacity in tensile lap splice length regions. The results showed that as higher strength concrete was employed, nor only development resistance capacity was influenced by cover thickness, but also more sufficient safety factor reserved shorter than the lap splice length provision in current design code. From experimental research results, high-strength concrete development length was not inverse ratio of ($\sqrt{f_{ck}}$) but directly inverse of $f_{ck}$, and it is also said that there is a certain limit length of the embedded steel over which the assumption of uniform bond stress distribution is valid specially for high-strength concrete not having a same embed length such as normal-strength concrete in current design criteria hypothesis.

  • PDF

외관불량 배전용 콘크리트전주 건전도 평가지표 개발 (A Development of Soundness Evaluation Index for Poor Appearance Distribution Concrete Poles)

  • 왕윤찬
    • 조명전기설비학회논문지
    • /
    • 제28권9호
    • /
    • pp.35-44
    • /
    • 2014
  • This study was to secure the safety of poor appearance distribution concrete poles effectively and to reduce the replacement costs of them by developing a soundness evaluation index. The researcher of this study investigated poor appearance types of concrete pole, collected 53 of test samples, and tested pole strength. As a result of strength test, only 17 percent of poor appearance concrete poles were below 2.0 of safety factor spec. As results of multiple regression analysis, it is verified that surface air void, horizontal crack, net-shaped crack, elapsed year, vertical crack, and deterioration in concrete compressive strength have statistically negative effects on safety factor of concrete poles in a significant level. The researcher set up a soundness evaluation index by using multiple regression equation, and suggested that poor appearance concrete poles should be replaced or reinforced only in case of soundness evaluation score of 150 or above.