• Title/Summary/Keyword: Strategy for storage

Search Result 403, Processing Time 0.031 seconds

Optimal Load Control Method for Solar-Powered House with Energy Storage System (전력저장장치를 이용한 태양광주택의 최적부하제어기법)

  • Jeon, Jeong-Pyo;Kim, Kwang-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.5
    • /
    • pp.644-651
    • /
    • 2014
  • The renewable energy system and the real-time pricing can provide the significant economic advantage for end-user of residential house. However, according to recent studies, high initial cost of renewable energy system such as photovoltaic (PV) system and lack of suitable load control methods adjusting electric power consumption in response to time-varying price are regarded as the major obstruction for introduction of renewable energy system and real-time pricing in residental household. In this paper, we propose automated optimal load control strategy which aim to achieve not only minimizing the electricity cost but also the increase in the utilization rates of PV generation power of residential PV house in real-time pricing environment. Simulation results show that our proposed optimal load control strategy leads to significant reduction in the electricity costs and increase in the utilization rates of power generated by PV system in comparison with the conventional PV house. Therefore, the proposed optimal load control strategy can provide more economic benefit to end-user.

A Numerical Modelling of Cogeneration Systems for the Short-Term Operation Strategy (열병합발전시스템의 단기운전계획을 위한 수리적모델 수립에 관한 연구)

  • Lyu, Seung-Heon;Lee, Jong-Bum;Kim, Joon-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.198-201
    • /
    • 1993
  • In this paper a numerical model of the industrial cogeneration system which have a thermal storage tank is proposed for the short-term operation strategy. Short-term operation costs of towing cycle and bottoming cycle are calculated by using the proposed model of a thermal storage tank. Simulation results of four cases are compared and analyzed each other. By these simulations which are similar to real operation circumstances, the validity of the proposed model is verified.

  • PDF

Ride-Through Technique for PMSG Wind Turbines using Energy Storage Systems

  • Nguyen, Thanh Hai;Lee, Dong-Choon
    • Journal of Power Electronics
    • /
    • v.10 no.6
    • /
    • pp.733-738
    • /
    • 2010
  • This paper deals with a ride-through technique for permanent-magnet synchronous generator (PMSG) wind turbine systems using energy storage systems (ESS). A control strategy which consists of current and power control loops for the energy storage systems is proposed. By increasing the generator speed, some portion of the turbine power can be stored in the system inertia. Therefore, the required energy capacity of the ESS can be decreased, which results in a low-cost system. In addition, the power fluctuations due to wind speed variations can be smoothened by controlling the ESS appropriately. The effectiveness of the proposed method is verified not only by the simulation results for a 2[MW] PMSG wind turbine system, but also by the experiment results for a reduced-scale turbine simulator.

Development of Re8ervoirs Storage Management System(RESTOMS) (저수관리 시스템 개발)

  • 김현영;황철상;정건배;정종호유
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.35 no.2
    • /
    • pp.65-72
    • /
    • 1993
  • When a drought occurs in an area irrigated by multi-reservoirs, onerating a single reservoir separately to control the reservoir' storage is not a desirable solution. In order to reduce damages effectively for the areal drought, the storage of the reservoirs within the areal boundary should be managed as a group. Storage management procedures are as follows : 1. Collecting and checking the present storages of all reservoirs 2. Computing the drought frequency and depth; and finally, establishing a suitable storage saving strategy based on the estimated drought depth. For the purpose of this storage management, the RESTOMS(Reservoirs Storage Management System) was developed and the system was composed of the PRIME computer and the ORACLE as a distributed database management system, which was the host computer of Rural Development Corporation and would be on-lined with the regional offices throughout the country. Reservoirs operated by Farm Land Improvment Association were comprised in the DB system. Using the RESTOMS, the drought frequencies and drought depths were calculated with respect to the reservoir storage records(1967 to 1992). It was obvious that the results were closely corresponding to the real drought records.

  • PDF

Dynamic Economic Dispatch and Control of a Stand-alone Microgrid in DongAo Island

  • Ma, Yiwei;Yang, Ping;Guo, Hongxia;Wang, Yuewu
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.1432-1440
    • /
    • 2015
  • A dynamic economic dispatch and control method is proposed to minimize the overall generating cost for a stand-alone microgrid in DongAo Island, which is integrated with wind turbine generator, solar PV, diesel generator, battery storage, the seawater desalination system and the conventional loads. A new dispatching strategy is presented based on the ranking of component generation costs and two different control modes, in which diesel generator and battery storage alternate to act as the master power source to follow system power fluctuation. The optimal models and GA-based optimization process are given to minimize the overall system generating cost subject to the corresponding constraints and the proposed dispatch strategy. The effectiveness of the proposed method is verified in the stand-alone microgrid in DongAo Island, and the results provide a feasible theoretical and technical basis for optimal energy management and operation control of stand-alone microgrid.

Smooth Wind Power Fluctuation Based on Battery Energy Storage System for Wind Farm

  • Wei, Zhang;Moon, Byung Young;Joo, Young Hoon
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.6
    • /
    • pp.2134-2141
    • /
    • 2014
  • This paper addresses on a wind power system with BESS(Battery Energy Storage System). The concerned system consists of four parts: the wind speed production model, the wind turbine model, configure capacity of the battery energy storage, battery model and control of the BESS. First of all, we produce wind speed by 4-component composite wind speed model. Secondly, the maximum available wind power is determined by analyzing the produced wind speed and the characteristic curve of wind power. Thirdly, we configure capacity of the BESS according to wind speed and characteristic curve of wind speed-power. Then, we propose a control strategy to track the power reference. Finally, some simulations have been demonstrated to visualize the feasibility of the proposed methodology.

RDP: A storage-tier-aware Robust Data Placement strategy for Hadoop in a Cloud-based Heterogeneous Environment

  • Muhammad Faseeh Qureshi, Nawab;Shin, Dong Ryeol
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.9
    • /
    • pp.4063-4086
    • /
    • 2016
  • Cloud computing is a robust technology, which facilitate to resolve many parallel distributed computing issues in the modern Big Data environment. Hadoop is an ecosystem, which process large data-sets in distributed computing environment. The HDFS is a filesystem of Hadoop, which process data blocks to the cluster nodes. The data block placement has become a bottleneck to overall performance in a Hadoop cluster. The current placement policy assumes that, all Datanodes have equal computing capacity to process data blocks. This computing capacity includes availability of same storage media and same processing performances of a node. As a result, Hadoop cluster performance gets effected with unbalanced workloads, inefficient storage-tier, network traffic congestion and HDFS integrity issues. This paper proposes a storage-tier-aware Robust Data Placement (RDP) scheme, which systematically resolves unbalanced workloads, reduces network congestion to an optimal state, utilizes storage-tier in a useful manner and minimizes the HDFS integrity issues. The experimental results show that the proposed approach reduced unbalanced workload issue to 72%. Moreover, the presented approach resolve storage-tier compatibility problem to 81% by predicting storage for block jobs and improved overall data block placement by 78% through pre-calculated computing capacity allocations and execution of map files over respective Namenode and Datanodes.

Supercooling Pretreatment Improves the Shelf-Life of Freeze-Dried Leuconostoc mesenteroides WiKim32

  • Seul-Gi Jeong;In Seong Choi;Ho Myeong Kim;Ji Yoon Chang;Hae Woong Park
    • Journal of Microbiology and Biotechnology
    • /
    • v.32 no.12
    • /
    • pp.1599-1604
    • /
    • 2022
  • Storage stability of freeze-dried lactic acid bacteria is a critical factor for their cost-effectiveness. Long-term storage of lactic acid bacteria enables microbial industry to reduce distribution costs. Herein, we investigated the effect of cold adaptation under supercooling conditions at -5℃ on the viability of Leuconostoc mesenteroides WiKim32 during the freeze-drying process and subsequent storage. Cold adaptation increased the thickness of exopolysaccharides (EPS) and improved the viability of freeze-dried Leu. mesenteroides WiKim32. Compared to non-adapted cells, cold-adapted cells showed a 35.4% increase in EPS thickness under supercooling conditions. The viability of EPS-hydrolyzed cells was lower than that of untreated cells, implying that EPS plays a role in protection during the freeze-drying process. Cold adaptation increased the storage stability of freeze-dried Leu. mesenteroides WiKim32. Fifty-six days after storage, the highest viability (71.3%) was achieved with cold adaptation at -5℃. When EPS-containing broth was added prior to the freeze-drying process, the viability further increased to 82.7%. These results imply that cold adaptation by supercooling pretreatment would be a good strategy for the long-term storage of Leu. mesenteroides WiKim32.

Methods for an application of real-time network control on distributed storage facilities (분산형 저류시설의 실시간 네트워크 제어기술 적용시 고려 사항)

  • Beak, Hyunwook;Ryu, Jaena;Oh, Jeill;Kim, Tae-Hyoung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.6
    • /
    • pp.711-721
    • /
    • 2013
  • Optimal operation of a combined sewer network with distributed storage facilities aims to use the whole retention capacity of all reservoirs efficiently before overflows take place somewhere in the considered network system. An efficient real-time network control (RTNC) strategy has been emerging as an attractive approach for reducing substantially the overflows from a sewer network compared to the conventional fixed or manually adjusted gate setting method, but the related concrete framework for RTC development has not been throughly introduced so far. The main goal of this study is to give a detailed description of the RTNC systems via reviewing several guidelines published abroad, and finally to suggest methods for the proper application of RTNC on distributed storage facilities. Especially, this study is focused on emphasizing the importance of hierarchical structure of RTNC system that consists of three control layers (management, global control and local control). Further, with regard to the global control layer which is responsible for the central overall network control, the wide-ranging details of two components (adaption and optimization layers) are also presented. This study can provide the valuable basis for the RTNC implementation in the particular sewer network with distributed multiple storage facilities.

A Control Strategy for Flywheel Energy Storage / Recovery System with Induction Machine (유도기를 이용한 플라이휠 에너지 저장 및 재생 시스템 제어 기법)

  • Son Jang-Kyung;Lee Hong-Hee;Nho Eui-Cheol;Kim Heung-Gun;Chun Tae-Won
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.5
    • /
    • pp.494-500
    • /
    • 2005
  • The paper proposed a control strategy for flywheel energy/recovery system with induction machine at the dynamic UPS system using the flywheel stored mechanical energy. The performances for the vector controlled induction generator are compared with those for the induction generator using slip control method. The strategy to improve the transient responses for dc link capacitor voltage is suggested at the transition from the motoring mode to the generating mode. The strategy Proposed by the paper is verified with experiment results using 32bit DSP.