• 제목/요약/키워드: Strand transfer

검색결과 59건 처리시간 0.031초

프리텐션 프리스트레스트 콘크리트 부재의 정착길이 평가 (Experimental study on development length of prestressing strand in pretensioned prestressed concrete members)

  • 김의성
    • 건설안전기술
    • /
    • 통권49호
    • /
    • pp.84-91
    • /
    • 2009
  • By bond mechanism between the prestressing strand and the concrete surrounding it, the effective force of prestressing must be transferred to the concrete entirely. The distance required to transfer the effective force of prestressing is called the transfer length, and the development length is the bond length required to anchor the strand as it resists external loads on the member. Transfer length was determined from the concrete strain profile at the level of the strands at transfer and development length was determined from various external loading lengths and compared with current code equation. Through the test results, bond failure is predicted based on the distress caused by cracks when they propagate within the transfer zone of prestressing strand. The current code equation was found to be conservative in comparison with the measured value.

  • PDF

프리텐션 프리스트레스트 콘크리트 부재의 정착길이 정가 (Experimental Study on Development Length of Prestressing Strand in Pretensioned Prestressed Concrete Members)

  • 김의성
    • 한국안전학회지
    • /
    • 제23권6호
    • /
    • pp.115-121
    • /
    • 2008
  • By bond mechanism between the prestressing strand and the concrete surrounding it, the effective force of prestressing must be transferred to the concrete entirely. The distance required to transfer the effective force of prestressing is called the transfer length, and the development length is the bond length required to anchor the strand as it resists external loads on the member. Transfer length was determined from the concrete strain profile at the level of the strands at transfer and development length was determined from various external loading lengths and compared with current code equation. Through the test results, bond failure is predicted based on the distress caused by cracks when they propagate within the transfer zone of prestressing strand. The current code equation was found to be conservative in comparison with the measured value.

Bond mechanism of 18-mm prestressing strands: New insights and design applications

  • Dang, Canh N.;Marti-Vargas, Jose R.;Hale, W. Micah
    • Structural Engineering and Mechanics
    • /
    • 제76권1호
    • /
    • pp.67-81
    • /
    • 2020
  • Pretensioned concrete (PC) is widely used in contemporary construction. Bond of prestressing strand is significant for composite-action between the strand and concrete in the transfer and flexural-bond zones of PC members. This study develops a new methodology for quantifying the bond of 18-mm prestressing strand in PC members based on results of a pullout test, the Standard Test for Strand Bond (STSB). The experimental program includes: (a) twenty-four pretensioned concrete beams, using a wide range of concrete compressive strength; and (b) twelve untensioned pullout specimens. By testing beams, the transfer length, flexural-bond length, and development length were all measured. In the STSB, the pullout forces for the strands were measured. Experimental results indicate a significant relationship between the bond of prestressing strand to the code-established design parameters, such as transfer length and development length. However, the code-predictions can be unconservative for the prestressing strands having a low STSB pullout force. Three simplified bond equations are proposed for the design applications of PC members.

Analytical model for transfer length prediction of 13 mm prestressing strand

  • Marti-Vargas, J.R.;Arbelaez, C.A.;Serna-Ros, P.;Navarro-Gregori, J.;Pallares-Rubio, L.
    • Structural Engineering and Mechanics
    • /
    • 제26권2호
    • /
    • pp.211-229
    • /
    • 2007
  • An experimental investigation to determine the transfer length of a seven-wire prestressing strand in different concretes is presented in this paper. A testing technique based on the analysis of bond behaviour by means of measuring the force supported by the prestressing strand on a series of specimens with different embedment lengths has been used. An analytical bond model to calculate the transfer length from an inelastic bond stress distribution along the transfer length has been obtained. A relationship between the plastic bond stress for transfer length and the concrete compressive strength at the time of prestress transfer has been found. An equation to predict the average and both the lower bound and the upper bound values of transfer length is proposed. The experimental results have not only been compared with the theoretical prediction from proposed equations in the literature, but also with experimental results obtained by several researchers.

압축강도 및 피복두께에 따른 프리텐션 부재의 전달길이 변화에 관한 연구 (An Experimental Study on Influence of Concrete Strength and Cover Size on Transfer Length of Prestressing Strand in Pretensioned Prestressed Concrete Members)

  • 오병환;김동백;김의성;최영철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.355-358
    • /
    • 1999
  • In recent times, large strands have become increasingly popular in the pretensioned prestressed industry and have found wide applications in varying geometries of sections. However, use of such elements and their behavior in several situations have been questioned with respect to anchoring of these strands in concrete. In addition, the experimental results available on bond are limited and information relating to large strands is rare. This study was conducted to determine the influence of some of the inadequately examined properties on transfer length of prestressing strand. The principle variables considered were strand size, concrete strength and clear bottom cover. The experimental results indicate clearly that concrete strength at transfer and cover size influence transfer length significantly. An attempt was made to suggest prediction equation for transfer length including above parameters.

  • PDF

고강도 프리텐션 프리스트레스트 콘크리트 부재 단부 영역에서의 PS 강연선 부착특성 연구 (Bond Characteristics of PS Strand around the End Zones of High Strength Pretensioned Prestressed Concrete Members)

  • 김동백;김의성
    • 한국안전학회지
    • /
    • 제15권3호
    • /
    • pp.102-107
    • /
    • 2000
  • The extensive use of pretensioned prestressed concrete in the modem construction industry, together with wider application of pretensioned components for structural purposes requires some important consideration on the adequate transfer of prestress force into the concrete, especially around the end zones of pretensioned member. The main objective of this paper is to study the effects of various important parameters on the bond characteristics of prestressing strand around the end zone of high strength pretensioned concrete members. To this end, a comprehensive experimental program has been set up. The principal test variables considered were strand diameter, concrete strength, concrete cover size. The present study provides valuable test data for the realistic and accurate determination of transfer length, which can be efficiently used for improving the design equation of transfer length in pretensioned prestressed concrete members.

  • PDF

한국형 PS정착구의 하중전달성능에 관한 연구 (Experimental Study on the Performance of Korean PS Anchorage System in terms of Load Transfer Test)

  • 김진국;이필구;장석윤
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2009년도 춘계 학술대회 제21권1호
    • /
    • pp.37-38
    • /
    • 2009
  • 이 논문은 한국형 PS정착구의 하중전달 성능에 관한 실험적 연구로 기존에 사용하고 있는 1860MPa 강연선과 포스코, 고려제강등을 통해 새로 개발되는 2200MPa급 강연선에 대하여 이루어졌다. 하중전달성능은 ETAG 기준에 따라 이루어졌으며 실험결과 1860MPa 강연선이 적용되는 구조물의 경우 모든 시험체가 실험기준을 만족하고 있음을 확인하였다. 한편, 2200MPa급 강연선이 적용될 경우 일부 정착구의 경우 허용기준을 만족하였지만 대부분은 적합하지 않은 것으로 나타났다. 따라서 2200MPa급 이상의 강연선에 대해서는 전용 정착구의 개발이 요구된다.

  • PDF

인장을 가하지 않은 PS강연선의 정착길이에 대한 실험적 연구 (An Experimental Study on Development Length of Untensioned Prestressing Strand)

  • 최준영;하상수;김승훈;최창식;이리형
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.331-334
    • /
    • 2005
  • The nature of bond of untensioned prestressed strand in concrete differs from that of plain or deformed reinforcing bar as well as tensioned prestressed strand. There is a very limited amount of published research information regarding bonding of this type reinforcing. In order to use and design untensioned strand as reinforcing, relationships defining the load transfer characteristics of the strand are necessary. A program based upon pullout tests was designed to develop data relating the critical parameters for determining load transfer behavior of the untensioned strand. The purpose of this study is to investigate the characteristics of bond and development length between untensioned strand and concrete. The test variables include diameter of strands (9.3mm, 12.7mm) and development lengths. The maximum bond stress at the 9.3mm and 12.7mm strands decreases with the increase of the rate of development length. The untensioned prestressed strands displayed bond performance when secure development length more than 80$\%$ according to the development of deformed bars equation.

  • PDF

Biochemical characteristics of functional domains using feline foamy virus integrase mutants

  • Yoo, Gwi-Woong;Shin, Cha-Gyun
    • BMB Reports
    • /
    • 제46권1호
    • /
    • pp.53-58
    • /
    • 2013
  • We constructed deletion mutants and seven point mutants by polymerase chain reaction to investigate the specificity of feline foamy virus integrase functional domains. Complementation reactions were performed for three enzymatic activities such as 3'-end processing, strand transfer, and disintegration. The complementation reactions with deletion mutants showed several activities for 3'-end processing and strand transfer. The conserved central domain and the combination of the N-terminal or C-terminal domains increased disintegration activity significantly. In the complementation reactions between deletion and point mutants, the combination between D107V and deletion mutants revealed 3'-end processing activities, but the combination with others did not have any activity, including strand transfer activities. Disintegration activity increased evenly, except the combination with glutamic acid 200. These results suggest that an intact central domain mediates enzymatic activities but fails to show these activities in the absence of the N-terminal or C-terminal domains.

프리텐션 부재의 휨부착에 의한 강연선 정착길이 연구 (An Experimental Study on Development Length of Strand in Pretensioned Concrete Members)

  • 오병환;최영철;김의성
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.367-370
    • /
    • 1999
  • An experimental study was carried out to estimate development lengths of the prestressing strand in pretensioned beams. Recent studies had indicated that current desing provision were inadequate. Objective of this investigation is to determine the effect of strand diameter and concrete cover in pretensioned beams. Strand of the 1.52cm diameter is more useful and economic than that of the 12.7mm diameter, but current provision does not include 15.2mm diameter strand in experimental data. Because the property of strand has been developed, current provision need to be improved. Based on the experimental data, it was determined that bond failure would be prevented if no cracking occured in transfer zone of a pretensioned strand.

  • PDF