• Title/Summary/Keyword: Strain gauge experiment

Search Result 71, Processing Time 0.026 seconds

The Characteristics of the Milling Tool Deflection According to the Variation of Helix Angle (헬릭스각의 변화에 따른 밀링공구의 변위 특성 연구)

  • Maeng, Min-Jae;Chung, Joon-Ki
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.6
    • /
    • pp.860-866
    • /
    • 2004
  • In the end milling operation the deflection of the cutter is an important factor affecting the accuracy of machining, with implications on the selection of cutting parameters and economics of the operation. Several studies were devoted to the end mill deflection and its effects, notably, providing a useful insight into the problem. Although the deflection affects adversely the accuracy, the flexibility of the cutter is beneficial in attenuating the overload in a sudden transient situation, as well as in attenuating chatter. The deflection of the end mill was studied both experimentally with strain gauge, tool dynamometer, laser measuring apparatus and on a finite element model of the cutting using ANSYS software. The deflection of machining tool with various helix angles was studied with FEM simulation and experiment. ANSYS analysis performed on the finite element model of the end mill provides deflection results which agree within 15.0% with the experimental ones.

A Study on the Radial Pulse Detection System for the Total Macjin( I ) (총안 맥진을 위한 맥동검출기 개발에 관한 연구( I ))

  • Kim, K.S.;Yang, S.Y.;Han, S.C.;Park, Y.B.;Kim, J.K.;Huh, W.
    • Proceedings of the IEEK Conference
    • /
    • 1999.06a
    • /
    • pp.551-554
    • /
    • 1999
  • In this paper, we developed a radial pulse transducer that has strain-gauge cantilever type load cell for total pulse detection on chongu arterial. The transducer consist of load cell and driving electronic circuits. Load cell consist of cantilever and two metal film strain gauge. The Pressure signal from chongu artery is delivered to load cell using artery rider that attached to cantilever Therefore the pressure signal convert to voltage signals by the developed transducer As the results of experiment, the developed transducer has very good linearity at pressure to voltage conversion. The total pulse detection transducer can detected three kinds of chongu artery pulse with conveniently.

  • PDF

A study on the characteristics of torque transducer (토오크 변환기의 특성에 대한 연구)

  • 최만용;임동규;한응교
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.4 no.3
    • /
    • pp.48-55
    • /
    • 1982
  • In the present the strain gauge type torque transducers consist of solid shaft as sensor, slip ring, brush and bridge circuit as detecting circuit. So in the case of measuring the low-capacity torque, the error caused by technical mistake in mounting stain gauge on the small sensor and especially by contact resistance between slip ring and brush takes place more than the large sensor. Therefore in this study constant voltage in order to have no effect of contact resistance is supplied to the hollow shaft and Schrobron Bridge Circuit. Through the experiment good results were obtained as follows; linearity, hysterisis and zero drift as static characteristics is within 1% F.S respectively. Also when loading, zero drift is about 2% F.S.

  • PDF

Rubber-liked Biomaterial Experimental Setup based on Nonlinear Elasticity Theory (비선형 탄성이론에 기초한 혈관류 생체재료 실험장치)

  • Kang, Tae-Won
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.6
    • /
    • pp.90-97
    • /
    • 2010
  • In order to understand the biomaterial like the blood vessel of artery, there is a need to quantify the biomechanical behavior of the vessel. Using computer-controlled experimental system, the experiment can acquire data such as inner pressure, axial load, diameter and axial gauge length without contacting the specimen. Rubber-liked material which is similar to passive artery was selected as pseudo-biomaterial. Deformations are measured for pressure-diameter curves. The data were collected and stored online to be used in the feedback control of experimental protocols. Finally, the illustrative data obtained from the experimental system were presented and the system shows that strain invariants are controlled to understand the nonlinear elastic behavior of biomaterial which is involved with strain energy function.

STRAIN AND TEMPERATURE CHANGES DURING THE POLYMERIZATION OF AUTOPOLYMERIZING ACRYLIC RESINS

  • Ahn Hyung-Jun;Kim Chang-Whe;Kim Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.6
    • /
    • pp.709-734
    • /
    • 2001
  • The aims of this experiment were to investigate the strain and temperature changes simultaneously within autopolymerzing acrylic resin specimens. A computerized data acquisition system with an electrical resistance strain gauge and a thermocouple was used over time periods up to 180 minutes. The overall strain kinetics, the effects of stress relaxation and additional heat supply during the polymerization were evaluated. Stone mold replicas with an inner butt-joint rectangular cavity ($40.0{\times}25.0mm$, 5.0mm in depth) were duplicated from a brass master mold. A strain gauge (AE-11-S50N-120-EC, CAS Inc., Korea) and a thermocouple were installed within the cavity, which had been connected to a personal computer and a precision signal conditioning amplifier (DA1600 Dynamic Strain Amplifier, CAS Inc., Korea) so that real-time recordings of both polymerization-induced strain and temperature changes were performed. After each of fresh resin mixture was poured into the mold replica, data recording was done up to 180 minutes with three-second interval. Each of two poly(methyl methacrylate) products (Duralay, Vertex) and a vinyl ethyl methacrylate product (Snap) was examined repeatedly ten times. Additionally, removal procedures were done after 15, 30 and 60 minutes from the start of mixing to evaluate the effect of stress relaxation after deflasking. Six specimens for each of nine conditions were examined. After removal from the mold, the specimen continued bench-curing up to 180 minutes. Using a waterbath (Hanau Junior Curing Unit, Model No.76-0, Teledyne Hanau, New York, U.S.A.) with its temperature control maintained at $50^{\circ}C$, heat-soaking procedures with two different durations (15 and 45 minutes) were done to evaluate the effect of additional heat supply on the strain and temperature changes within the specimen during the polymerization. Five specimens for each of six conditions were examined. Within the parameters of this study the following results were drawn: 1. The mean shrinkage strains reached $-3095{\mu}{\epsilon},\;-1796{\mu}{\epsilon}$ and $-2959{\mu}{\epsilon}$ for Duralay, Snap and Vertex, respectively. The mean maximum temperature rise reached $56.7^{\circ}C,\;41.3^{\circ}C$ and $56.1^{\circ}C$ for Duralay, Snap, and Vertex, respectively. A vinyl ethyl methacrylate product (Snap) showed significantly less polymerization shrinkage strain (p<0.01) and significantly lower maximum temperature rise (p<0.01) than the other two poly(methyl methacrylate) products (Duralay, Vertex). 2. Mean maximum shrinkage rate for each resin was calculated to $-31.8{\mu}{\epsilon}/sec,\;-15.9{\mu}{\epsilon}/sec$ and $-31.8{\mu}{\epsilon}/sec$ for Duralay, Snap and Vertex, respectively. Snap showed significantly lower maximum shrinkage rate than Duralay and Vertex (p<0.01). 3. From the second experiment, some expansion was observed immediately after removal of specimen from the mold, and the amount of expansion increased as the removal time was delayed. For each removal time, Snap showed significantly less strain changes than the other two poly(methyl methacrylate) products (p<0.05). 4. During the external heat supply for the resins, higher maximum temperature rises were found. Meanwhile, the maximum shrinkage rates were not different from those of room temperature polymerizations. 5. From the third experiment, the external heat supply for the resins during polymerization could temporarily decrease or even reverse shrinkage strains of each material. But, shrinkage re-occurred in the linear nature after completion of heat supply. 6. Linear thermal expansion coefficients obtained from the end of heat supply continuing for an additional 5 minutes, showed that Snap exhibited significantly lower values than the other two poly(methyl methacrylate) products (p<0.01). Moreover, little difference was found between the mean linear thermal expansion coefficients obtained from two different heating durations (p>0.05).

  • PDF

The elastic strain analysis of forged product and die according to the forging mode (단조형식에 따른 단조품과 금형의 탄성 변형에 관한 연구)

  • Lee, D.K.;Lee, Y.S.;Kim, W.I.;Lee, J.H.
    • Proceedings of the KSME Conference
    • /
    • 2001.06c
    • /
    • pp.586-591
    • /
    • 2001
  • In the cold forging, elastic deformation of the die has been investigated to improve the accuracy of cold forged parts with F.E.M analysis using DEFORM, and with experiments using strain gauges. In the experiments, initial billet was selected to easily find the effect of elastic deformation according to the forging modes, extrusion and upsetting type, and only extrusion type. Elastic deformation of the die can be obtained by the signal from the strain gauges and this signal can be amplified by data acquisition system during the process. In the F.E.M analysis, two types of analysis are used to predict elastic strain of the die. To improve an accuracy of forged product and die dimension, this study compared with strain distribution between experiment and F.E.M analysis. As a result, the history of the deformation of the die and elastic recovery of forged product can be obtained by the elastic strain analysis of forged product and die according to the forging modes.

  • PDF

Performance evaluation of smart prefabricated concrete elements

  • Zonta, Daniele;Pozzi, Matteo;Bursi, Oreste S.
    • Smart Structures and Systems
    • /
    • v.3 no.4
    • /
    • pp.475-494
    • /
    • 2007
  • This paper deals with the development of an innovative distributed construction system based on smart prefabricated concrete elements for the real-time condition assessment of civil infrastructure. So far, two reduced-scale prototypes have been produced, each consisting of a $0.2{\times}0.3{\times}5.6$ m RC beam specifically designed for permanent instrumentation with 8 long-gauge Fiber Optic Sensors (FOS) at the lower edge. The sensing system is Fiber Bragg Grating (FBG)-based and can measure finite displacements both static and dynamic with a sample frequency of 625 Hz per channel. The performance of the system underwent validation in the laboratory. The scope of the experiment was to correlate changes in the dynamic response of the beams with different damage scenarios, using a direct modal strain approach. Each specimen was dynamically characterized in the undamaged state and in various damage conditions, simulating different cracking levels and recurrent deterioration scenarios, including cover spalling and corrosion of the reinforcement. The location and the extent of damage are evaluated by calculating damage indices which take account of changes in frequency and in strain-mode-shapes. The outcomes of the experiment demonstrate how the damage distribution detected by the system is fully compatible with the damage extent appraised by inspection.

Study on FBG Sensors for Hull Stress Monitoring (선체 응력 모니터링을 위한 FBG 센서에 대한 연구)

  • Kim, Yu-Mi;Lee, Nam-Kwon;Lee, Seung-Hwan;Bae, Dong-Myung;Yu, Yun-Sik
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.4
    • /
    • pp.276-282
    • /
    • 2012
  • Vessels receive stress during their navigations as well as during their cargo operations. This stress may cause damages to the hull and may result in accidents. So the hull stress monitoring system(HSMS) is recommended in order to prevent these accidents. In this paper, we manufactured fiber Bragg grating(FBG) sensor and the model ship for towing tank experiments. The strain characteristics of the model ship on the water wave were measured through the towing tank experiment. The FBG sensors and electric strain gauges were attached on the connection jig, and then the characteristics of the FBG sensor were compared with those of the electric strain gauge. The strain of model ship was increased according to the increment of the amplitude of water wave. In particular, the largest strain was measured in the center of the model ship. As the wave period increased, the strain of model ship was decreased.

Development of Fiber Optic Total Reflected Extrinsic Fabry-Perot Interferometric Sensor for Structural Strain Measurement (구조물의 변형률 측정을 위한 광섬유 TR-EFPI 센서의 개발)

  • Kwon, In-Bum;Choi, Man-Yong;Moon, Hahn-Gue;Kim, Min-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.2
    • /
    • pp.96-105
    • /
    • 2000
  • Fiber optic TR-EFPI(total reflected extrtinsic Fabry-Perot interferometric) sensor was developed to measure the strain of structures, such as building, bridge, aircraft, etc. It has been difficult to distinguish the increase and decrease of the strain from the conventional fiber optic EFPI sensor because their signals only have a sinusoidal wave pattern related to the change of strain. Also, the absolute strain could not be measured by the simple fiber optic EFPI sensor. In this study, in order to measure the magnitude of strain with the direction of strain, the fiber optic sensor was simply constructed with the total reflected EFPI sensor probe. This probe was manufactured with a single mode fiber and a mirror coated fiber in a silica glass capillary tube. The output signal of this fiber optic TR-EFPT sensor can give the information about the magnitude and the direction of strain. The loading-unloading test was performed by the universal testing machine with alluminum beam specimen to compare the strain from fiber optic TR-EFPI sensor with the value from electrical strain gauge. In the result of this experiment. the strain from fiber optic TR-EFPI sensor had a good agreement with the values from the electrical strain gauge.

  • PDF

Damage characterization in fiber reinforced polymer via Digital Volume Correlation

  • Vrgoc, Ana;Tomicevic, Zvonimir;Smaniotto, Benjamin;Hild, Francois
    • Coupled systems mechanics
    • /
    • v.10 no.6
    • /
    • pp.545-560
    • /
    • 2021
  • An in situ experiment imaged via X-ray computed tomography was performed on a continuous glass fiber mat reinforced epoxy resin composite. The investigated dogbone specimen was subjected to uniaxial cyclic tension. The reconstructed scans (i.e., gray level volumes) were registered via Digital Volume Correlation. The calculated maximum principal strain fields and correlation residual maps exhibited strain localization areas within the material bulk, thus indicating damage inception and growth toward the specimen surface. Strained bands and areas of elevated correlation residuals were mainly concentrated in the narrowest gauge section of the investigated specimen, as well as on the specimen ligament edges. Gray level residuals were laid over the corresponding mesostructure to highlight and characterize damage development within the material bulk.