• Title/Summary/Keyword: Storage section

Search Result 240, Processing Time 0.021 seconds

Environmental Impact Assessment of the Yangyang Pumped Storage Power Plant Construction on the Namdae-Chun River, Korea (남대천 양양 양수발전소의 환경영향과 대책)

  • Chun, Sang-Ki
    • Journal of Environmental Impact Assessment
    • /
    • v.6 no.1
    • /
    • pp.151-160
    • /
    • 1997
  • The Yangyang Pumped Storage Power Plant is being constructed by Korea Electric Power Corporation in Namdae-Chun River, Korea. The Yangyang Pumped Storage Power Plant has 1000MW capacity with upper reservior, lower reservior, hydrauric tunnel and underground power plant facilities. But NGO(Non Governmental Groups) and residents are worried about the power plant construction because of some problems, as follows. (1) Namdae-Chun River is principal salmon returning river in Korea. (2) Namdae-Chun River is main water supply source of the Yangyang country. So, brief explanation of Environmental Impacts Assessment executed by Korea Electric Power Corporation, main environmental impacts and countermeasures will be introduced.

  • PDF

Determination of Floodplain Restoration Area Based on Old Maps and Analysis on Flood Storage Effects of Flood Mitigation Sections (고지도를 활용한 홍수터 복원 구역 선정 및 홍수완충공간의 홍수 저류효과 분석)

  • Dong-jin Lee;Un Ji;Sanghyuk Kim;Hong-Kyu Ahn;Eun-kyung Jang
    • Ecology and Resilient Infrastructure
    • /
    • v.10 no.2
    • /
    • pp.40-49
    • /
    • 2023
  • To reduce the damage of extreme flooding caused by climate change and to create flood mitigation sections in a nature-friendly riparian area, it is necessary to restore the floodplain area by referring to the past floodplain section of the current inland waterfront area before the levee was built. This study proposed a method of selecting a location for floodplain restoration using old maps of the Geum River study section and analyzed the effect of flood level reduction through unsteady flow numerical simulations using the floodplain as a flood mitigation space. As a result of analyzing changes in the river areas using old maps, the river section was estimated to gradually reduce by 27.8% (1,059,380 m2) in 2020 compared to 1919, and it was found to have an effective storage capacity of 2,200,868 m3 when restored to offline storage. The flood level and discharge control effects analyzed based on HEC-RAS unsteady flow simulation were 16 cm and 219.01 m3/s, respectively, in the downstream cross-section. In the numerical simulation in this paper, the flood mitigation space was applied as an offline reservoir. The effect of reducing the flood level may differ if levee retreat/relocation is applied.

Changes of Protein Composition and Muscle Tissues in Top Shell Meat during Frozen Storage (바다방석고둥육의 동결저장중 단백질조성과 근육조직의 변화)

  • 송대진;김창용;박환준
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.22 no.6
    • /
    • pp.763-770
    • /
    • 1993
  • To investigate the quality changes during frozen storage, top shell, Omphalius pfeifferi capenteri, was stored at -18$^{\circ}C$, -$25^{\circ}C$ and -3$0^{\circ}C$ immediately after shelling and water holding capacity, protein composition and histological features were examined with the lapsed period of the storage. During the storage period, amount of free drip was increased with higher frozen temperature and longer frozen period, but with the longer storage period, the lower water holding capacity was observed. The extractability and composition of muscle protein, sarcoplasmic protein and stroma protein were rather stable regardless of frozen temperature and frozen storage period. However, the extractability of myofibrillar protein was decreased with higher frozen temperature and longer frozen storage period. On the changes of muscle tissue structure, following points were observed. 1) In the muscle tissue structure of fresh sample, fine muscle fiber was closely distributed all over the tissue regardless of cross and longitudinal section. 2) In tissue structure under frozen state, it was observed that ice crystals apparently grew with the higher storage temperature. Empty spaces between muscle bundles which wee formed by aggregations of muscle fiber were observed after 3 months storage at -18$^{\circ}C$ . 3) Tissue structure in thawed state was restored satisfactorily after 1 month storage regardless of storage temperature. After 3 months storage at -3$0^{\circ}C$, muscle tissue was well restored, but at -18$^{\circ}C$, empty spaces were apparent due to incomplete restoration.

  • PDF

A Study on the Architectural Planning of traditional herbal medicine distribution supporting facilities (한약재유통지원시설의 건축계획에 관한 연구)

  • Bae, Joa-Sup;Oh, Jong-Hee;Kang, Won-Pil
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.14 no.2
    • /
    • pp.53-64
    • /
    • 2008
  • This study is the architectural planning of 5 distribution supporting facilities for traditional herbal medicine cultivated in the rural areas. The main function of the facility consists of storage, pre-treatment/processing, loading/unloading and the assistant function consists of inspection, office, exhibition/sale, technical equipment etc. The planning shows the modular plan and the section plan of the storage space reflecting the shape and size of storage container, the action radius of carrier and the possibilities of space lease. The total floor area of the storage is 3,192$m^2$ consisting of 27 space. The total floor area of the pre-treatment/processing is 1,488$m^2$ consisting of 7 space. The total floor area of the loading/unloading is 329$m^2$ consisting of 4 space. The total floor area of each facility storage is 8,284$m^2$ including of public space 2,170$m^2$. Also this planning shows the preliminary design, "fundamental model design" for 5 rural government BTL project. Therefore, this result of planning will be the guidelines of the RFP(Request For Proposal) for the private sector company interested in this BTL project.

  • PDF

A Study on the Development of Design Model of Ecological Park as Stormwater Storage Facilities (저류지 생태공원 설계모형 개발에 관한 연구)

  • Byeon, Wooil
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.9 no.3
    • /
    • pp.1-16
    • /
    • 2006
  • The purpose of this study is to develop design model of ecological park as stormwater storage facilities. The results are as follows : First, the design model of ecological park as stormwater storage facilities consider ecological and landscape characteristics such as high efficiency of land use, function as disaster prevention, ecological water purification, formation of habitat for flora and fauna. Second, this study demonstrates two types of plane structure and eight types of designed section. They can be combined and designed depending on conditions of each site. The facilities of stormwater storage conduct disaster prevention system and ecological park. Retention pond in stormwater storage facilities for ecological park also should be made for ecological restoration in the site. Third, the ecological park provide the basis for ecological network from in-site to out-site. Therefore its conservation and restoration plan consider the ecosystems of the site. Fourth, the most important factor for maintenance and management for retention pond is keeping water quality. Sustainable Structured wetland Biotop system is suggested for ecological water purification system in the retention pond which is one of the constructed wetland system using multi-celled aquatic plant and pond. This system can also provide habitat for animals and plants, water friendly park for men, and beautiful landscape.

Case Study on Seepage Analysis and Countermeasure Against the Seepage Flow of In-ground LNG Storage Tank (LNG 지하저장탱크의 침투해석 및 용수 대책공법에 대한 사례분석)

  • 신은철;오영인;이상혁
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.03a
    • /
    • pp.65-72
    • /
    • 2001
  • Since Pyoungtaek thermal power plant began using natural gas in 1986, the annual using volume has rapidly increased and reached 12.7 million tons in 1999. When the natural gas is cooled to a temperature of approximately -162$^{\circ}$C at atmospheric pressure, it condenses to a liquid called liquefied natural gas(LNG). LNG has a special characters such as odorless, colorless, non-corrosive, and non-toxic. So, LNG storage tank, tanker ship, transfer pipelines are required the special storage and transportation systems and technology. The presently operating LNG terminals are Pyongtaek and Inchon terminals. A total of 19 above-ground LNG storage tanks(100 thousand ㎘ grade) are currently in operation with a sendout capacity of 4,360tons/hour. To meet the growing domestic demand of LNG supply, the Inchon receiving terminal is expanding(six in-ground tank) and constructing a third LNG terminal at Tongyong. In this paper, case study on seepage analysis and countermeasure against increasing the seepage volume of in-ground LNG storage tank excavation work is reported. The results of an additional seepage analysis are presented to verify the design seepage volume of assumption section and seepage volume after curtain-grouting in the slurry wall.

  • PDF

Design of a Solar Thermal Storage System Employing Heat Pipes and Molten Salts (히트파이프와 용융염을 사용하는 태양열 축열조의 설계)

  • Lee, Jung-Ryun;Boo, Joon-Hong
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.86-91
    • /
    • 2011
  • Thermal design was conducted for a solar thermal storage system in a medium-temperature range between $200^{\circ}C$ and $400^{\circ}C$. The system was composed of heat pipes as heat carrier and molten salts as phase-change storage material. Each heat pipe penetrated through the storage system and had two heat-exchanging sections at both ends to interact with high-and low-temperature steams, while it exchanged heat with molten salts in the middle section. During a heat-storage mode, the heat pipes transferred heat from the hot steam at one side to the molten salts and it transferred heat from the molten salt to the cold steam at the other side during the heat-dissipating mode. A tube-bank type heat exchanger theory was applied to this design task to meet the required inlet and outlet temperatures of the steams depending on the operation modes. Several design variables were considered including the lengths of evaporator and condenser of a heat pipe, traverse and longitudinal pitches of the pipe, and the number of rows of the heat pipes for two different molten salt baths. An optimum design results were presented with discussion.

  • PDF

A Study on Formation of Slurry Ice by using the Reversing Flow in a Bundle of Tube (역전 유동층을 이용한 관군 내에서의 슬러리아이스 생성에 관한 연구)

  • Oh, Cheol;Choi, Young-Gyu
    • Journal of Navigation and Port Research
    • /
    • v.35 no.5
    • /
    • pp.365-370
    • /
    • 2011
  • The ice-thermal energy storage cooling system has been applied to relief a significant portion of the peak demand of electricity during the daytime in summer. Slurry ice type system is one kind of ice-thermal storage cooling system utilizing cheaper off-peak electricity. This study is experimented to observe an influence of experimental conditions on production characteristics of slurry ice by using reversing flow, which is putting reversing material into test section to disturb ice adhesion. At this experiment, poly propylene ball of dimeter 10 mm was used as reversing material, and ethylene glycol-water solution of 20wt% concentration was used as flow material. The experimental apparatus was constructed of the slurry ice making and storage tank(test section), the brine tank, pumps for ethylene glycol-water solution and brine circulating, a mass flow-meter, data logger for fluid temperature measuring. The experiments were carried out under various conditions, with volumetric flow rate, ball filling rate and air filling rate.

토양 세정법을 이용한 실제 유류 오염 토양 및 지하수 정화

  • 강현민;이민희;정상용;강동환
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.04a
    • /
    • pp.418-421
    • /
    • 2003
  • Surfactant enhanced in-situ soil flushing was peformed to remediate the soil and groundwater at an oil contaminated site, and the effluent solution was treated by the chemical treatment process including DAF(Dissolved Air Flotation). A section from the contaminated site(4.5m$\times$4.5m$\times$6.0m) was selected for the research, which was composed of heterogeneous sandy and silt-sandy soils with average Hydraulic conductivity of 2.0$\times$10$^{-4}$ cm/sec. Two percent of sorbitan monooleate(POE 20) and 0.07% of iso-prophyl alcohol were mixed for the surfactant solution and 3 pore volumes of surfactant solution were injected to remove oil from the contaminant section. Four injection wells and two extraction wells were built in the section to flush surfactant solution. Water samples taken from extraction wells and the storage tank were analyzed by GC(gas-chromatography) for TPH concentration with different time. Five pore volumes of solution were extracted while TPH concentration in soil and groundwater at the section were below the Waste Water Discharge Limit(WWDL). Total 18.5kg of oil (TPH) was removed from the section. The concentration of heavy metals in the effluent solution also increased with the increase of TPH concentration, suggesting that the surfactant enhanced in-situ flushing be available to remove not only oil but heavy metals from contaminated sites. Results suggest that in-situ soil flushing and chemical treatment process including DAF could be a successful process to remediate contaminated sites distributed in Korea.

  • PDF

Added Mass Estimation of Square Sections Coupled with a Liquid Using Finite Element Method

  • Jeong, Kyeong Hoon;Jhung, Myung Jo
    • Nuclear Engineering and Technology
    • /
    • v.49 no.1
    • /
    • pp.234-244
    • /
    • 2017
  • Natural frequencies of immersed square sections decrease due to a contribution of added mass to the movement of square sections. In this study, natural frequencies of square sections are obtained as a function of gap size between the square section and a rigid square wall using the finite element method. Additionally, they are used to extract the added mass effect on translational and rotation motions. Published information and studies on the translational and torsional vibration of square beams are also examined for practical use. D coupling of a square section is also investigated for multiple square sections. The suggested added mass estimation can be applicable to the spent fuel storage design of a pressurized light water modulated nuclear power plant.