• Title/Summary/Keyword: Storage battery

Search Result 882, Processing Time 0.024 seconds

SOH Estimation and Feature Extraction using Principal Component Analysis based on Health Indicator for High Energy Battery Pack (건전성 지표 기반 주성분분석(PCA)을 적용한 고용량 배터리 팩의 열화 인자 추출 방법 및 SOH 진단 기법 연구)

  • Lee, Pyeong-Yeon;Kwon, Sanguk;Kang, Deokhun;Han, Seungyun;Kim, Jonghoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.5
    • /
    • pp.376-384
    • /
    • 2020
  • An energy storage system is composed of lithium-ion batteries in modern applications. Batteries are regarded as storage devices for renewable and residual energy. The failure of batteries can cause the performance reduction and explosion of battery systems. High maintenance cost is essential when dealing with the problem of battery safety. Therefore an accurate health diagnosis is required to ensure the high reliability of battery systems. A battery pack is a combination of single cells in series and parallel connections. A battery pack has to consider various factors to assess battery health. Battery health involves conventional factors and additional factors, such as cell-to-cell imbalance. For large applications, state-of-health (SOH) can be inaccurate because of the lack of factors that indicate the state of the battery pack. In this study, six characterization factors are proposed for improving the SOH estimation of battery packs. The six proposed characterization factors can be regarded as health indicators (HIs). The six HIs are applied to the principal component analysis (PCA) algorithm. To reflect information regarding capacity, voltage, and temperature, the PCA algorithm extracts new degradation factors by using the six HIs. The new degradation factors are applied to a multiple regression model. Results show the advancement and improvement of SOH estimation.

Grid-Connected Peak Load Compensation System Based on Lithium Polymer Battery Energy Storage System

  • Jung, Doo-Yong;Ji, Young-Hyok;Lee, Su-Won;Won, Chung-Yuen;Seo, Kwang-Duk;Jung, Yong-Chae
    • Proceedings of the KIPE Conference
    • /
    • 2009.11a
    • /
    • pp.265-267
    • /
    • 2009
  • we proposed a grid connected peak load compensation system with high discharge current characteristics based on lithium polymer battery for development of the next generation power-station. The lithium polymer battery has faster discharge current characteristics than conventional battery, so that can compensate high active power demanded by load in a short time using the low capacity battery bank. Therefore, it is possible to control power leveling of grid by measuring storage energy of battery and active power which is needed from load. The validity of proposed system was verified through the simulation and experiment.

  • PDF

Development of Battery Management System using Multiple Microcontroller (다중 마이크로콘트롤러를 사용한 배터리 관리 시스템의 개발)

  • Choi, Jeong-Won;Jang, WoonGeun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.21 no.6
    • /
    • pp.329-335
    • /
    • 2018
  • In an electric vehicle and Energy Storage System(ESS), a large number of batteries are connected in series or parallel to obtain high voltage and current. The battery management system(BMS) is needed because battery has a characteristic that explode in overcharging and overcurrent situations due to the nature of the battery material and the battery life is dramatically reduced when the battery is overdischarged below the specified voltage. In this paper, we proposed a system that can manage a large amount of batteries through the communication of master-slave type with multiple microcontroller. We confirmed the stable operation of the proposed system through the balancing-charging and storage mode experiments.

Online DCIR Estimation for Series-connected Battery Cells using Matrix-Switched Capacitor Converter

  • La, Phuong-Ha;Choi, Sung-Jin
    • Proceedings of the KIPE Conference
    • /
    • 2020.08a
    • /
    • pp.381-382
    • /
    • 2020
  • In the battery energy storage system, battery cells are connected in series to increase the operating voltage. Due to the difference in characteristics, the performance degradation of cells is dissimilar. This paper proposes an online DC internal impedance estimation for battery cells in the series string using a matrix-switched capacitor converter, which is already verified as useful for the series balancing of the cells. The simulation in the hardware in the loop test rig shows good accuracy and the feasibility of the proposed method.

  • PDF

A Coordinative Control Strategy for Power Electronic Transformer Based Battery Energy Storage Systems

  • Sun, Yuwei;Liu, Jiaomin;Li, Yonggang;Fu, Chao;Wang, Yi
    • Journal of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.1625-1636
    • /
    • 2017
  • A power electronic transformer (PET) based on the cascaded H-bridge (CHB) and the isolated bidirectional DC/DC converter (IBDC) is capable of accommodating a large scale battery energy storage system (BESS) in the medium-voltage grid, and is referred to as a power electronic transformer based battery energy storage system (PET-BESS). This paper investigates the PET-BESS and proposes a coordinative control strategy for it. In the proposed method, the CHB controls the power flow and the battery state-of-charge (SOC) balancing, while the IBDC maintains the dc-link voltages with feedforward implementation of the power reference and the switch status of the CHB. State-feedback and linear quadratic Riccati (LQR) methods have been adopted in the CHB to control the grid current, active power and reactive power. A hybrid PWM modulating method is utilized to achieve SOC balancing, where battery SOC sorting is involved. The feedforward path of the power reference and the CHB switch status substantially reduces the dc-link voltage fluctuations under dynamic power variations. The effectiveness of the proposed control has been verified both by simulation and experimental results. The performance of the PET-BESS under bidirectional power flow has been improved, and the battery SOC values have been adjusted to converge.

A Study on the Application Cases Analysis of ESS(Energy Storage System) to Electric Power System (에너지 저장 시스템의 전력계통 적용 사례 분석)

  • Ko, Yun-Seok
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.1
    • /
    • pp.53-58
    • /
    • 2016
  • Because a progressive tax of home electricity rates is charged and a continuous rise of industrial electricity rates is expected in order to solve the global warming, the high oil prices and the serious power shortage problem, the efforts to apply the energy storage systems which can significantly improve the energy usage efficiency to the smart grid are trying newly. In this study, characteristics of the secondary battery which can be used as energy storage devices, the structure and operation principle of a lithium-ion battery, and the concept of energy storage systems are research and analyzed. In addition, in this paper, the base technologies which are required to apply to the energy storage system to electric power system are established by studying about installation location and application methodology of energy storage system to electric power system.

The current status and direction of development of lead acid battey for electric energy storage system. (전력저장용 연축전지의 개발방향 및 현황)

  • Chon, M.H.;Kim, K.T.;Park, J.C.;Kim, H.Y.;Ko, Yo;Eom, Y.C.
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.277-283
    • /
    • 1989
  • For the battery energy storage system (BESS), battery is one of most important parts. Various new type batteries for load shifting are under developing. The lead acid battery technology status such as structure, charge and discharge characteristics, life cycle etc. is reviewed and research trend is also introduced.

  • PDF

Single-Phase Double-Conversion UPS with Energy Storage System (ESS 기능을 갖는 단상 이중변환 UPS)

  • Lim, Seung-Beom;Hong, Soon-Chan
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.137-138
    • /
    • 2013
  • This paper proposes the single-phase double-conversion UPS(Uninterruptible Power Supply) with ESS(Energy Storage System). The Proposed system is operating in three modes, which are normal mode, battery mode, and bypass mode. Not only in black-out but also in peak load times, the system is operating in battery mode which is using the stored energy of the battery to manage the power effectively. The validity of proposed system could be verified by simulations and experiments.

  • PDF

Sodium Sulfur Battery for Energy Storage System (대용량 에너지 저장시스템을 위한 나트륨 유황전지)

  • Kim, Dul-Sun;Kang, Sungwhan;Kim, Jun-Young;Ahn, Jou-Hyeon;Lee, Chang-Hui;Jung, Keeyoung;Park, Yoon-Cheol;Kim, Goun;Cho, Namung
    • Journal of the Korean Electrochemical Society
    • /
    • v.16 no.3
    • /
    • pp.111-122
    • /
    • 2013
  • Sodium sulfur (NAS) battery is a high energy storage system (ESS). These days, as the use of renewable green energy like wind energy, solar energy and ocean energy is rapidly increasing, the demand of ESS is increasing and NAS battery is considered to be one of the most promising ESS. Since NAS battery has a high energy density(3 times of lead acid battery), long cycle life and no self-charge and discharge, it is a good candidate for ESS. A NAS battery consists of sulfur as the positive electrode, sodium as the negative electrode and ${\beta}$"-alumina as the electrolyte and a separator simultaneously. Since sulfur is an insulator, carbon felt should be used as conductor with sulfur and so the composition and property of the cathode could largely influence the cell performance and life cycle. Therefore, in this paper, the composition of NAS battery, the property of carbon felt and sodium polysulfides ($Na_2S_x$, intermediates of discharge), and the effects of these factors on cycle performance of cells are described in detail.