• Title/Summary/Keyword: Storage Strategy

Search Result 429, Processing Time 0.034 seconds

Workshop Method Adaptation of SI Theory for Applying Closed Schools (SI(Skeleton/Infill)이론을 적용한 폐교활용의 워크숍 방법론)

  • Yi, Yong Kyu
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.13 no.2
    • /
    • pp.63-70
    • /
    • 2011
  • Despite the high historical and topological values, closed schools are rarely reutilized. The reason can be likely explained by integrity of the building structure and unawareness of the operation and maintenance for closed schools. The purpose of this study is finding a possibility of reusing closed schools by deploying SI (Skeleton and Infill) theory. SI theory is separating the "skeleton" like structure from "infill" such as interior furnishings to extend building life without complete demolishing of the building. It will allow satisfying various local community demands by alternating infill without demolishing of historical and topological value of the building. The experimental test was undertaken with closed school for this study. The local community's demands or opinions were reflected to develop a strategy for deploying infill system especially movable storage furniture to closed school. The study finds possibilities that SI theory can assist local community to 1) construct potential demand for utilizing closed school and 2) suggest strategy for operating and maintaining closed school.

A Numerical Modelling of Cogeneration Systems for the Short-Term Operation Strategy (열병합발전시스템의 단기운전계획을 위한 수리적모델 수립에 관한 연구)

  • Lyu, Seung-Heon;Lee, Jong-Bum;Kim, Joon-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.198-201
    • /
    • 1993
  • In this paper a numerical model of the industrial cogeneration system which have a thermal storage tank is proposed for the short-term operation strategy. Short-term operation costs of towing cycle and bottoming cycle are calculated by using the proposed model of a thermal storage tank. Simulation results of four cases are compared and analyzed each other. By these simulations which are similar to real operation circumstances, the validity of the proposed model is verified.

  • PDF

A Strategy for Balanced Power Regulation of Energy Storage Systems in a Distribution System during Closed-Loop Operation

  • Han, Yoon-Tak;Oh, Joon-Seok;Cha, Jae-Hun;An, Jae-Yun;Hyun, Seung-Yoon;Lee, Jong-Kwan;Seo, In-Yong;Kim, Jae-Eon
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.6
    • /
    • pp.2208-2218
    • /
    • 2017
  • To resolve overload in a distribution system, a distribution system operator (DSO) often performs a load transfer using normally open tie points and switches in the distribution line. During this process, the distribution system is momentarily operated in closed-loop operation. A closed-loop current in the distribution system can cause a power failure due to excess breaking current in the circuit breakers and reclosers. Therefore, it is necessary to calculate the closed-loop current exactly. However, if there are a large number of distributed generation (DG) systems in the distribution system, such as energy storage systems (ESS), they might obstruct the closed-loop operation based on bidirectional power flow. For quick and precise operation of a closed-loop system, the ESS has to regulate the power generation while satisfying closed-loop operation in the worst cases. We propose a strategy for balanced power regulation of an ESS. Simulations were carried out using PSCAD/EMTDC, and the results were compared with calculation results.

Dynamic Economic Dispatch and Control of a Stand-alone Microgrid in DongAo Island

  • Ma, Yiwei;Yang, Ping;Guo, Hongxia;Wang, Yuewu
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.1432-1440
    • /
    • 2015
  • A dynamic economic dispatch and control method is proposed to minimize the overall generating cost for a stand-alone microgrid in DongAo Island, which is integrated with wind turbine generator, solar PV, diesel generator, battery storage, the seawater desalination system and the conventional loads. A new dispatching strategy is presented based on the ranking of component generation costs and two different control modes, in which diesel generator and battery storage alternate to act as the master power source to follow system power fluctuation. The optimal models and GA-based optimization process are given to minimize the overall system generating cost subject to the corresponding constraints and the proposed dispatch strategy. The effectiveness of the proposed method is verified in the stand-alone microgrid in DongAo Island, and the results provide a feasible theoretical and technical basis for optimal energy management and operation control of stand-alone microgrid.

Coordinated Control Strategies with and without Circulating Current in Unified Power Quality

  • Feng, Xing-tian;Zhang, Zhi-hua
    • Journal of Power Electronics
    • /
    • v.15 no.5
    • /
    • pp.1348-1357
    • /
    • 2015
  • Under traditional unified power quality conditioner (UPQC) control, a UPQC series converter (SC) is mainly used to handle grid-side power quality problems while its parallel converter (PC) is mainly used to handle load-side power quality problems. The SC and PC are relatively independent. The SC is usually in standby mode and it only runs when the grid voltage abruptly changes. In this paper, novel UPQC coordinated control strategies are proposed which use the SC to share the reactive power compensation function of the PC especially without grid-side power quality problems. However, in some cases, there will be a circulating current between the SC and the PC, which will probably influence the compensation fashion, the compensation capacity, or the normal work of the UPQC. Through an active power circulation analysis, strategies with and without a circulating current are presented which fuses the reactive power allocation strategy of the SC and the PC, the composite control strategy of the SC and the compensation strategy of the DC storage unit. Both of the strategies effectively solve the SC long term idle problem, limit the influence of the circulating current, optimize all of the UPQC units and reduce the production cost. An analysis, along with simulation andexperimental results, is presented to verify the feasibility and effectiveness of the proposed control strategies.

Optimal Configuration Algorithm for ESS with Renewable Energy Resources Considering Peak-shaving Effects (신재생 에너지가 도입된 전력저장장치의 첨두부하절감 효과를 고려한 최적 구성 알고리즘)

  • Lee, Na-Eun;Kim, Wook-Won;Kim, Jin-O
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.9
    • /
    • pp.1199-1205
    • /
    • 2014
  • A power system configuration has been increasingly advanced with a number of generating units. In particular, renewable energy resources are widely introduced due to the environmental issues. When applying the renewable energy sources with the ESS (Energy Storage System), the ESS is the role of a potential generating resource in the power system while mitigating the output volatility of renewable energy resources. Thus, for applications of the ESS, the surrounding environment of it should be considered, which means that capacity and energy of the ESS can be affected. Moreover, operation strategy of the ESS should be proposed according to the installation purpose as well as the surrounding environment. In the paper, operation strategy of the ESS is proposed considering load demand and the output of renewable energy resources on a hourly basis. Then, the cost of electrical energy is minimized based on the economic model that consists of capital cost, operation cost, fuel cost, and grid cost for a year. It is sure that peak-shaving effects can be achieved while satisfying the minimum cost of electrical energy.

Optimal Load Control Method for Solar-Powered House with Energy Storage System (전력저장장치를 이용한 태양광주택의 최적부하제어기법)

  • Jeon, Jeong-Pyo;Kim, Kwang-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.5
    • /
    • pp.644-651
    • /
    • 2014
  • The renewable energy system and the real-time pricing can provide the significant economic advantage for end-user of residential house. However, according to recent studies, high initial cost of renewable energy system such as photovoltaic (PV) system and lack of suitable load control methods adjusting electric power consumption in response to time-varying price are regarded as the major obstruction for introduction of renewable energy system and real-time pricing in residental household. In this paper, we propose automated optimal load control strategy which aim to achieve not only minimizing the electricity cost but also the increase in the utilization rates of PV generation power of residential PV house in real-time pricing environment. Simulation results show that our proposed optimal load control strategy leads to significant reduction in the electricity costs and increase in the utilization rates of power generated by PV system in comparison with the conventional PV house. Therefore, the proposed optimal load control strategy can provide more economic benefit to end-user.

RDP: A storage-tier-aware Robust Data Placement strategy for Hadoop in a Cloud-based Heterogeneous Environment

  • Muhammad Faseeh Qureshi, Nawab;Shin, Dong Ryeol
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.9
    • /
    • pp.4063-4086
    • /
    • 2016
  • Cloud computing is a robust technology, which facilitate to resolve many parallel distributed computing issues in the modern Big Data environment. Hadoop is an ecosystem, which process large data-sets in distributed computing environment. The HDFS is a filesystem of Hadoop, which process data blocks to the cluster nodes. The data block placement has become a bottleneck to overall performance in a Hadoop cluster. The current placement policy assumes that, all Datanodes have equal computing capacity to process data blocks. This computing capacity includes availability of same storage media and same processing performances of a node. As a result, Hadoop cluster performance gets effected with unbalanced workloads, inefficient storage-tier, network traffic congestion and HDFS integrity issues. This paper proposes a storage-tier-aware Robust Data Placement (RDP) scheme, which systematically resolves unbalanced workloads, reduces network congestion to an optimal state, utilizes storage-tier in a useful manner and minimizes the HDFS integrity issues. The experimental results show that the proposed approach reduced unbalanced workload issue to 72%. Moreover, the presented approach resolve storage-tier compatibility problem to 81% by predicting storage for block jobs and improved overall data block placement by 78% through pre-calculated computing capacity allocations and execution of map files over respective Namenode and Datanodes.

Supercooling Pretreatment Improves the Shelf-Life of Freeze-Dried Leuconostoc mesenteroides WiKim32

  • Seul-Gi Jeong;In Seong Choi;Ho Myeong Kim;Ji Yoon Chang;Hae Woong Park
    • Journal of Microbiology and Biotechnology
    • /
    • v.32 no.12
    • /
    • pp.1599-1604
    • /
    • 2022
  • Storage stability of freeze-dried lactic acid bacteria is a critical factor for their cost-effectiveness. Long-term storage of lactic acid bacteria enables microbial industry to reduce distribution costs. Herein, we investigated the effect of cold adaptation under supercooling conditions at -5℃ on the viability of Leuconostoc mesenteroides WiKim32 during the freeze-drying process and subsequent storage. Cold adaptation increased the thickness of exopolysaccharides (EPS) and improved the viability of freeze-dried Leu. mesenteroides WiKim32. Compared to non-adapted cells, cold-adapted cells showed a 35.4% increase in EPS thickness under supercooling conditions. The viability of EPS-hydrolyzed cells was lower than that of untreated cells, implying that EPS plays a role in protection during the freeze-drying process. Cold adaptation increased the storage stability of freeze-dried Leu. mesenteroides WiKim32. Fifty-six days after storage, the highest viability (71.3%) was achieved with cold adaptation at -5℃. When EPS-containing broth was added prior to the freeze-drying process, the viability further increased to 82.7%. These results imply that cold adaptation by supercooling pretreatment would be a good strategy for the long-term storage of Leu. mesenteroides WiKim32.