• Title/Summary/Keyword: Storage Strategy

Search Result 429, Processing Time 0.027 seconds

Energy Management Strategy and Adaptive Control for SMES in Power System with a Photovoltaic Farm

  • Kim, Seung-Tak;Park, Jung-Wook
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.1182-1187
    • /
    • 2014
  • This paper proposes an energy management strategy and adaptive control for superconducting magnetic energy storage (SMES) in a distribution power system with a grid-connected photovoltaic (PV) farm. Application of the SMES system can decrease the output power fluctuations of PV system effectively. Also, it can control the real and reactive powers corresponding to the scheduled reference values with adequate converter capacity, which are required at a steady-state operating point. Therefore, the adaptive control strategy for SMES plays a key role in improving the system stability when the PV generation causes uncertain variations due to weather conditions. The performance of proposed energy management strategy and control method for the SMES is then evaluated with several case studies based on the PSCAD/EMTDC$^{(R)}$ simulation.

An Evaluation of Chiller Control Strategy in Ice Storage System for Cost-Saving Operation (운전비 절감을 위한 빙축열시스템 냉동기 운전기법 평가)

  • Lee, Kyoung-Ho;Choi, Byoung-Youn;Lee, Sang-Ryoul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.2
    • /
    • pp.97-105
    • /
    • 2008
  • This paper presents simulated and experimental test results of optimal control algorithm for an encapsulated ice thermal storage system with full capacity chiller operation. The algorithm finds an optimal combination of a chiller and/or a storage tank operation for the minimum total operation cost through a cycle of charging and discharging. Dynamic programming is used to find the optimal control schedule. The conventional control strategy of chiller-priority is the baseline case for comparing with the optimal control strategy through simulation and experimental test. Simulation shows that operating cost for the optimal control with chiller on-off operation is not so different from that with chiller part load capacity control. As a result from the experimental test, the optimal control operation according to the simulated operation schedule showed about 14 % of cost saving compared with the chiller-priority control.

A Bidirectional Single-Stage DC/AC Converter for Grid Connected Energy Storage Systems

  • Chen, Jianliang;Liao, Xiaozhong;Sha, Deshang
    • Journal of Power Electronics
    • /
    • v.15 no.4
    • /
    • pp.1026-1034
    • /
    • 2015
  • In this paper, a unified control strategy using the current space vector modulation (CSVM) technique is proposed and applied to a bidirectional three-phase DC/AC converter. The operation of the converter changes with the direction of the power flow. In the charging mode, it works as a buck type rectifier; and during the discharging mode, it operates as a boost type inverter, which makes it suitable as an interface between high voltage AC grids and low voltage energy storage devices. This topology has the following advantages: high conversion efficiency, high power factor at the grid side, tight control of the charging current and fast transition between the charging and discharging modes. The operating principle of the mode analysis, the gate signal generation, the general control strategy and the transition from a constant current (CC) to a constant voltage (CV) in the charging mode are discussed. The proposed control strategy has been validated by simulations and experimental results obtained with a 1kW laboratory prototype using supercapacitors as an energy storage device.

A Numerical Modelling of Cogeneration Systems for the Short-Term Operation Strategy (열병합발전시스템의 단기운전계획을 위한 수리적 모델 수립에 고나한 연구)

  • 류승헌;이종범;김준현
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.5
    • /
    • pp.721-729
    • /
    • 1994
  • In this paper an optimization of the industrial congeneration system which have a thermal storage tank is proposed for the short-term operation strategy. Short-term operation costs of topping cycle and bottoming cycle are calculated by using the proosed model of a thermal storage tank. Simulation result of four cases are compared and analyzed each other.By these simulations which are similar to real operation circumstances. the validity of the proposed model is verified.

A Study on the Optimal Control Strategy of Air-Conditioning System with Slab Thermal Storage - The Difference by the Presence of Radiant Heat as a Criterion Factor - (슬래브축열의 최적제어방책에 관한 연구 -평가요소로 복사열의 고려 유무에 의한 차이-)

  • Jung Jae-Hoon;Shin Young-Gy
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.4
    • /
    • pp.287-296
    • /
    • 2006
  • In this paper, optimal control strategy of the air-conditioning system with slab thermal storage was investigated based on the optimal control theory. An optimal heat output to the plenum chamber and the air-conditioned room was determined based on two kinds of criterion functions. The first one requires small deviation in room air temperature from a set-point value and low energy consumption. It is shown that the optimized control is to store heat through the whole storage time and to increase storage rate gradually with time. As the second case, a criterion that both a deviation of operative temperature from a set-point temperature and the energy consumption should be minimized was adopted. The room air temperature was a little high and the cooling load during storage time was reduced, compared with the results when a criterion function considering only the room air temperature is used.

Underground Space Development and Strategy in Korea (국내 지하공간 개발 및 대책)

  • Shin, Hee-Soon
    • Tunnel and Underground Space
    • /
    • v.23 no.5
    • /
    • pp.327-336
    • /
    • 2013
  • Approximately 70% of the Korean peninsula is composed of mountains, around 99,274 $km^2$. Even worse, population rate of Korea is the No.3 in the world now. Accordingly, it is necessary to develop the potential underground space actively with the concept of another territory to be utilized. The development of underground space should be considered not a choice but an indispensable issue. Since 1970s, many large-scale underground structures have been constructed like as crude-oil storage bins, liquefied petroleum gas storage caverns, and underground pumped storage powerplants. Also, In urban area, the underground facilities such as subway networks, underground shopping mall, underground pedestrian network, electric power tunnels, and car parking lots have been used extensively. The scale of Yeosu oil and gas underground storage facility and Seoul subway systems are one of the massive scale in the world. Recently, the trend of the development of underground space becomes more diverse and larger scale. The current status of Korean underground space developments and strategy are described in this paper.

Temporal Data Migration Strategies by Time Granularity and LST-GET (시간단위와 LST-GET에 의한 시간지원 데이터의 이동 기법)

  • 윤홍원;김경석
    • Journal of Korea Multimedia Society
    • /
    • v.2 no.1
    • /
    • pp.9-21
    • /
    • 1999
  • This paper presents the time-segmented storage structure in order to increment search performance and the two data migration strategies: migration by Time Granularity and migration by LST-GET. In the migration strategy by Time Granularity, we describe how to assign entity version to the past, current segment, and future segments. We also describe searching and moving processes for data validity at a granularity level. In the migration strategy by LST-GET, we describe how to computer the value of dividing criterion. We simulate the search performance of the proposed segmented storage structure in comparison with the conventional storage structure in comparison with the conventional storage structure in relational database system. Finally, extensive simulation studies are performed in order to compare the search performance of the migration strategies with the time-segmented storage structure.

  • PDF

Design and Implementation of a Viewer for Class Components Retrieval (클래스 부품 검색을 위한 Viewer의 설계 및 구현)

  • 정미정;송영재
    • Proceedings of the IEEK Conference
    • /
    • 1999.11a
    • /
    • pp.426-429
    • /
    • 1999
  • Many similar class components are stored in object-storage but the object-storage has needed the retrieval function of correct component for reuse. Accordingly this paper designed the class component retrieval viewer of the object-storage by using the improved spreading activation strategy. Object-storage has made up of information of inheritance relation, superclass, subclass, and we defined the queries about each class function. Also we specified connectionist relaxation of the each class and query, finally we gained retrieval result which showed highest activation value order of class component information including the query function.

  • PDF

Power Management Strategy and Performance Evaluation for OpenStack Object Storage (오픈스택 기반 객체 스토리지를 위한 전력관리 기법과 성능 평가)

  • Ahn, Cheong-Jin;Song, Tae-Gun;Lee, Byeong-Hyeon;Kim, Deok-Hwan
    • KIISE Transactions on Computing Practices
    • /
    • v.22 no.6
    • /
    • pp.296-301
    • /
    • 2016
  • Object-based storage is an efficient storage solution that can handle unstructured data and shows better security and scalability than traditional block-based storage. However, in terms of power management, Object-based storage writes multiple copies in storage cluster, hence many servers consume unnecessary power in idle state. In order to resolve this problem, it is necessary to apply power management strategy by adjusting power mode of servers in idle state according to their workloads. In this paper, we proposed a new dynamic power management (DPM) method to transform power mode of storage servers dynamically according to workload information sent from proxy server. The experimental result shows that the proposed power management technic reduces total power consumption by 12% in the OpenStack based Swift object storage.

Assessment of Carbon Storage Capacity of Stands in Abandoned Coal Mine Forest Rehabilitation Areas over time for its Development of Management Strategy (폐탄광 산림복구지 관리방안 도출을 위한 산림복구 후 시간경과에 따른 임분탄소저장량 평가)

  • Mun Ho Jung;Kwan In Park;Ji Hye Kim;Won Hyun Ji
    • Journal of Environmental Science International
    • /
    • v.32 no.4
    • /
    • pp.233-242
    • /
    • 2023
  • The objective of this study was to develop a management strategy for the recovery of carbon storage capacity of abandoned coal mine forest rehabilitation area. For the purpose, the biomass and stand carbon storage over time after the forest rehabilitation by tree type for Betula platyphylla, Pinus densiflora, and Alnus hirsuta trees which are major tree species widely planted for the forest rehabilitation in the abandoned coal mine were calculated, and compared them with general forest. The carbon storage in abandoned coal mine forest rehabilitation areas was lower than that in general forests, and based on tree species, Pinus densiflora stored 48.9%, Alnus hirsuta 41.1%, and Betula platyphylla 27.0%. This low carbon storage is thought to be caused by poor growth because soil chemical properties, such as low TOC and total nitrogen content, in the soil of abandoned coal mine forest rehabilitation areas, were adverse to vegetation growth compared to those in general forests. DBH, stand biomass, and stand carbon storage tended to increase after forest rehabilitation over time, whereas stand density decreased. Stand' biomass and carbon storage increased as DBH and stand density increased, but there was a negative correlation between stand density and DBH. Therefore, after forest rehabilitation, growth status should be monitored, an appropriate growth space for trees should be maintained by thinning and pruning, and the soil chemical properties such as fertilization must be managed. It is expected that the carbon storage capacity the forest rehabilitation area could be restored to a level similar to that of general forests.