• Title/Summary/Keyword: Stitch

Search Result 241, Processing Time 0.034 seconds

The Effective Reduction Method of Unstable Zygomatic Arch Fracture with Thermo-Splint (Thermo-splint를 이용한 불안정한 관골궁골절에 대한 효과적인 고정방법)

  • Kim, Sun Heum;Lee, Soo Hyang;Choi, Hyun Gon;Shin, Dong Hyeok;Uhm, Ki Il;Song, Wu Chul
    • Archives of Plastic Surgery
    • /
    • v.35 no.1
    • /
    • pp.110-115
    • /
    • 2008
  • Purpose: The objective of this study is to propose an effective management of unstable zygomatic arch fracture. The reduction methods of arch fracture were relatively simple but the maintenance of reduction state is very troublesome. On this, authors introduce an effective management method of unstable zygomatic arch fracture. Methods: Authors experienced 23 cases of unstable segmental zygomatic arch fractures and used Thermo-splint in all cases. All the arch fractures were reduced through Gillies' approach under the general anesthesia. After the reduction, the most effective suspension points were marked on the covering skin of the fractured arch. A needle of heavy nonabsorbable suture material was inserted toward the marking site under the reduced zygomatic arch. And then Therm-splint was dipped in the hot water, and we got the splint pattern of patient face. Reshaped Thermo-splint was trimmed and fixated with previous suspension suture materials. More additive suspension was done if necessary. The splint was applied for in two to three weeks postoperatively. Results: In all the cases, good cosmetic and functional results were observed without severe complications. There were 4 cases of incomplete reductions but they also had no specific problems. There were no facial nerve symptom and scar(stitch mark). Postoperative slight tenderness and trismus were completely subsided after removal of the splint. Conclusion: The Thermo-splint safely protect and maintain the postoperative reduction state. The application, maintenance and removal were easy and simple. It could be reformed to any contour of face and had enough rigidity for supporting. Above all these things, effective prevention of displacement and easy manipulation were significant merit. Authors experienced good results with Thermo-splint, and would introduce it for another method of management of zygomatic arch fracture.

Visual Sensibility Evaluation of Fancy Yarns for Hand Knitting of using Computer Knitting Simulation -Application of SDS-ONE Paint Function- (Computer Knitting Simulation을 활용한 장식사 니트소재의 시각적 감성평가 -SDS-ONE의 Paint 기능 활용-)

  • Kim, Mi-Jin;Lee, Yoon-Mi;Kim, Young-Joo;Park, Myung-Ja
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.32 no.9
    • /
    • pp.1333-1342
    • /
    • 2008
  • This study intended to evaluate the visual sensibility of textiles of knitting simulation through the painting function of SDS-ONE, a computer knitting system, with the use of various fancy yarns for hand knitting. For this study, six kinds of fancy yarns with difference manufacturing style and form were selected: loop yarn, tamtam yarn, fur1 yarn, fur2 yarn, ladder yarn, and tape yarn. In order to create a computer knitting simulation, paint function of SDS-ONE was employed to scan the fancy yarns for hand knitting with a scanner. Then, after the registration of the yarns as data, the yarn was brought in for knitting simulation in plain stitch with 3 gauge. After that a survey was conducted involving 60 female experts in their twenties. Using SPSS 12.0, factor analysis, reliability, Pearson correlation coefficient, ANOVA, Duncan test, and regression analysis were performed to analyze the collected data. First, according to the result of analyzing the visual sense factor, three factors of the 'inflexibleness/ruggedness sense', 'lightweight sense', and 'smoothness sense' was extracted. According to the result of analyzing the visual sensibility factor, three factors of the 'activity', 'grace', and 'purity' was extracted. Second, With regard to preference and purchase intention, the knitted fabric with tamtam yarn(H2) was preferred than the other samples, indicating that the respondents had intention to purchase it. As for word-of-mouth intention, H2 ranked the first place, implying the respondents had intention to recommend it to other people. Third, the examination of the use of products each knitting simulation knit found that sweater and muffler are the most appropriate knit products. And H2 was the most suitable sample for sweater and muffler products. This study tried to prove that knit textile can be visually evaluated through a computer knitting simulation without the actual knitting and then to provide accurate data to related companies or the academic circle.

Effect of Stitching on Mechanical and Impact Properties of Glass Fiber Reinforced Composite (스티칭에 의한 유리섬유강화 복합재료의 물성 및 충격거동 변화)

  • Park, Jae-Yong;Kang, Tae-Jin;Yuk, Jong-Il
    • Korean Journal of Materials Research
    • /
    • v.2 no.5
    • /
    • pp.366-374
    • /
    • 1992
  • Mechanical and impact properties of stitched S2 glass fiber reinforced polyester woven laminates composites have been studied. Laminates were stitched using Kevlar 49 thread with 1/2, 1, and 2 inch stitch spacing. Tensile and 3-point bending tests haute been performed to evaluate the mechanical properties of stitched and unstitched laminates. Impact tests at applied energy of 234.7J were performed to examine the impact behavior and toughness changes of the specimen. The same specimens were also tested repeatedly at low impact energy level of 110.2J for 3 times to evaluate damage tolerance properties. The tensile and 3-point bending test results showed that one inch spacing specimen had the highest tensile and flexural strength. It also showed the highest energy absorption capability and the best damage tolerance property at the repeated impact test. The half inch spacing specimen showed the lowest tensile strength and energy absorption property at the impact energy level of 234.7J, even though it had the highest frequency of stitching thread.

  • PDF

FunRank: Finding 1-Day Vulnerability with Call-Site and Data-Flow Analysis (FunRank: 함수 호출 관계 및 데이터 흐름 분석을 통한 공개된 취약점 식별)

  • Jaehyu Lee;Jihun Baek;Hyungon Moon
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.33 no.2
    • /
    • pp.305-318
    • /
    • 2023
  • The complexity of software products led many manufacturers to stitch open-source software for composing a product. Using open-source help reduce the development cost, but the difference in the different development life cycles makes it difficult to keep the product up-to-date. For this reason, even the patches for known vulnerabilities are not adopted quickly enough, leaving the entire product under threat. Existing studies propose to use binary differentiation techniques to determine if a product is left vulnerable against a particular vulnerability. Despite their effectiveness in finding real-world vulnerabilities, they often fail to locate the evidence of a vulnerability if it is a small function that usually is inlined at compile time. This work presents our tool FunRank which is designed to identify the short functions. Our experiments using synthesized and real-world software products show that FunRank can identify the short, inlined functions that suggest that the program is left vulnerable to a particular vulnerability.

Conservation Treatment and Scientific Investigation of Daehye Bogakseonsaseo (Letters of Master Bogak) in the Goryeo Dynasty (고려시대 대혜보각선사서의 보존처리 및 과학적 조사)

  • Jang Yeonhee
    • Conservation Science in Museum
    • /
    • v.29
    • /
    • pp.47-64
    • /
    • 2023
  • Daehye Bogakseonsaseo (Letters of Master Bogak) in the possession of the National Museum of Korea is a Goryeo-era book produced in 1387, which was acquired in 2005 in a state of severe general damage. Subsequently, its production techniques and materials were examined using bibliographical characteristics and scientific analysis, based on which an overall conservation treatment was carried out. Janghwang(mounting) in bibliographical characteristics is a five-hole-stitch binding (五針眼線裝本), a single-lined rectangular box (四周單邊), and no column lines. The conservation treatment was examined in two aspects: the basic form and the conservation treatment process. The book is composed of the outer cover, original cover, end paper, and inner paper of 0.04-0.07mm thick, which is significantly thinner than general book paper. The conservation treatment was applied after the entire book was disassembled, based on the assessment that both the cover and the inner sheets of paper were in a dire condition due to deterioration. The conservation treatment comprised of the process of disassembly, cleaning, reinforcement of defective parts, scanning, and binding, with a paulownia box made for its storage. At the time of disassembly, samples were made for the inner sheets and the book string in order to conduct fiber identification. The fibers were identified using Safranin and C-stains. Safranin staining identified a thick fiber wall, in addition to cross-marking, dislocation, and transparent membranes. C-stain staining identified the fiber as mulberry, given the dark red residue. The book strap has a flat, circular cross-section, and was identified as cotton fiber, since a lumen was observed in the center.

Arthroscopic Transosseous Suture Repair for Bankart Lesion with a Flexible Drill Device - An Experimental and Preliminary Clinical Report - (유연성 천공기를 이용한 Bankart 병변의 골관통식 봉합 - 동물 실험 및 예비 임상 결과 보고 -)

  • Park, Jin-Su;Won, Ye-Yeon;Yoo, Jung-Han;Park, Yong-Wook;Noh, Kyu-Chul;Chung, Kuk-Jin;Kim, Hong-Kyun;Hwang, Ji-Hyo;Lee, Young-Bum;Suh, Il-Woo
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.1
    • /
    • pp.72-78
    • /
    • 2010
  • Purpose: Too develop a flexible drill device that can be inserted into the shoulder joint so that arthroscopic transosseous suture repair for Bankart lesion is possible. Materials and Methods: We created a device composed of a flexible drill unit and a guide pipe unit. The flexible drill unit was made of flexible multifilament wires (1.2 mm in diameter) that was twisted into one cord so that it can flex in any direction and a drill bit (1.2 mm in diameter) that is attached onto one end of the flexible wire. The guide pipe unit was a 150 mm long metal pipe (2.0 mm in inner diameter and 3.0 mm in outer diameter), with one end bent to 30 degrees. The flexible drill set was inserted into the shoulder joint through the posterior portal of the joint. The guide pipe component was placed onto the medial wall of the glenoid so that the pipe was placed 5 mm posterior to the margin of the anterior glenoid rim. The flexible drill was driven through the glenoid by the power drill so that holes were made in the glenoid. A non- absorbable suture was passed through the hole. Tying of a sliding knot tying was accomplished over the capsule and labrum after making a stitch through the capsule and labrum with a suture hook loaded with suture passer. The same procedures were done at the 2 and 4 O'Clock positions of the glenoid. Results: Five cases with Bankart lesion received arthroscopic transosseous repair with our flexible drill device. There were no intraoperative problems. Neither redislocation nor subluxation was reported at final follow-up. Conclusion: Arthroscopic transosseous suture repair without suture anchors and easy tying of a sliding knot are possible with a flexible drill set.

The Results of Arthroscopic Double-Row Rotator Cuff Repairs with Combined Knot-tying and Knotless Suture Anchors (매듭 결속과 비매듭 봉합나사를 이용한 관절경적 이열 회전근개 봉합술의 결과)

  • Ku, Jung-Hoei;Lee, Choon-Key;Cho, Hyung-Lae;Choi, Seung-Hyun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.3
    • /
    • pp.172-179
    • /
    • 2008
  • Purpose: To evaluate the functional and structural results of arthroscopic double-row repair using combined knot-tying and knotless suture anchors in rotator cuff tears. Materials and Methods: From March 2006 to June 2007, twenty-one patients (15 males, 6 females; mean age 55.6 years; range 48 to 67) were included who underwent arthroscopic double-row repair for full-thickness tears of the rotator cuff following conservative treatment for a mean of 6.5 months (range 3 to 11). The tear size was carefully inspected arthroscopically and we found 2 small, 13 medium and 6 large-sized rotator cuff tears, with a mean tear size of 2.5cm(range 1.8 to 3.2). The repair constructs were consisted of horizontal mattress sutures using conventional knot-tying suture anchors medially and simple suture at the same level of medial row stitch with Bioknotless RC anchors (DePuy Mitek, Norwood, MA) as lateral row. Clinical and functional evaluations were made according to the range of motion, the ASES, UCLA scale and the isokinetic strength testing. Postoperative cuff integrity was determined through magnetic resonance imaging. The mean follow-up was 15 months (range 13 to 24). Results: The average clinical outcome scores and strength were all improved significantly at the time of the final follow-up (p < 0.01). Nineteen patients (90%) were satisfied with the result of the treatment. In 17 of 21 patients (81%) were judged to reveal healed tendon on magnetic resonance imaging at a mean of 7 months postoperatively. There were no significant functional differences according to the preoperative tear size (p<0.01), but large-sized tear shows less favorable structural results in 3 out of 6 cases(50%). Conclusion: Our results document the usefulness and variability of arthroscopic double-row rotator cuff repairs comparable to the results of the other types of double-row repairs.

  • PDF

Effects of Cnidium officinale Makino and Tabanus bovinus in a CAM and Rat Corneal anti-angiogenesis (장요막과 흰쥐 각막에서의 신생혈관 억제를 위한 약재(Cnidium officinale Makino와 Tabanus bovinus) 효과 규명)

  • Han, Sun Hee;Kim, Dae Nyoun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.1
    • /
    • pp.39-43
    • /
    • 2002
  • This study was investigated the anti-angiogenic activities of Cnidium officinale Makino and Tabanus bovinus by using Chorioallantoic membrane (CAM) and rat cornea. First experiment, the fertilized chicken eggs were kept in a humidified egg incubator at $37^{\circ}C$. After 4 days incubation, about 3 ml of albumin was aspirated from eggs with an hypodermic needles through a small hole drilled at the narrow end of the eggs, and the shell membrane on the floor of the air sac was peeled away. Embryos with chorioallantois of 3~5 mm in diameter were employed for the assay of antiangiogenic activity. Retinoic acid was used as a positive control for this experiment. After 48 h of treatment. branching pattern of blood vessels below coverslip containing retinoic acid ($10{\mu}g/egg$) was dramatically decreased. A simiar angiogenic inhibition was observed in the CAM treated with $50{\mu}g/egg$ of Cnidium omcinale Makino and Tabanus bovinus extracts. Second experiment, rat corneal neovascularization was induced by suturing (one stitch) the cornea with 10-0 nylon, and terramycin was applied on the cornea for I week to prevent corneal inflammation. In the cornea of rats untreated with herbal extracts, numerous vessels were usually seen invading the cornea by day 2 or 3 after suture, and reaching the lesion area within 5~6 days. Corneal neovascularization was gradually increased and peaked at 3 weeks. In contrast to this, herbal extracts conspicuously inhibited the angiogenesis, Oral administration of herbal extracts (20 mg/kg body weight/day) for 4 weeks significantly inhibited the rat corneal angiogenesis induced by suture, and the length of blood vessels in herbal medicine-treated rat cornea was conspicuously lower than that in control animals. A similar phenomenon was also observed in the rat cornea treated with thalidomide (200 mg/kg body weight/day). These findings indicate the anti-angiogenic properties of Cnidium officinale Makino and Tabanus bovinus, suggesting that these properties may be one of the pharmacological mechanisms underlying the anti-tumor and anti-metastatic activities of herbal extracts tested in this study.

  • PDF

The Use of Arthroscopic UU Stich for Rotator Cuff Tear and Clinical Results (회전근 개 파열의 관절경하 봉합에서 새로운 봉합 방법의 이용)

  • Ko, Sang-Hun;Shin, Seung-Myeong;Choi, Young-Jin;Cha, Jae-Ryong;Park, Han-Chang
    • Clinics in Shoulder and Elbow
    • /
    • v.14 no.1
    • /
    • pp.67-72
    • /
    • 2011
  • Purpose: There are various known methods for arthroscopic rotator cuff repair. The purpose of this retrospective study is to report on the clinical results and anatomical results of UU repair surgery, which is a new repair method. Materials and Methods: We enrolled 156 patients (88 men and 68 women) who underwent UU repair for rotator cuff tears from January 2009 to May 2010 in our hospital. Their average age was 55 years old (range: 38~75 years old) and the average follow-up period was 12 months (range: 6~23 months). For determining the results, we evaluated the VAS for pain, the daily living index (ADL) in the ASES scores, the UCLA and KSS scores, and all these tests were conducted at the first hospital visit and 6 months and 1 year after surgery and at the final follow-up. During the follow-up period, MRI was performed 3 and 6 months after surgery only in the patients who consented to MRI scans to confirm the presence of re-rupture. Results: The average scores of the VAS as a pain indicator decreased from 7.0 before surgery to 2.7 after surgery (p<0.05). The UCLA and KSS scores increased from 22.2 to 32.5 and from 83.7 to 91.5, and the changes was significant (p<0.05). For the active joint range of motion, the average forward flexion was improved from 125 to 175 degrees, the average lateral external rotation was improved from 38 to 58 degrees, and the average abduction was improved from 104 to 169 degrees. Out of a total of 156 patients, re-rupture was observed in 4 cases (3%) of 117 cases (75%) for which MRI was performed (with consent) between 3 and 6 months after surgery. Conclusion: UU repair surgery as arthroscopic repair of rotator cuff tear is a good repair method that shows excellent clinical results and a low re-rupture rate.

3D analysis of soft tissue around implant after flap folding suture (Flap folding suture를 활용한 판막의 고정에 따른 임플란트 주변 연조직 3차원 부피 변화 관찰)

  • Jung, Sae-Young;Kang, Dae-Young;Shin, Hyun-Seung;Park, Jung-Chul
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.37 no.3
    • /
    • pp.130-137
    • /
    • 2021
  • Purpose: The various suture techniques can be utilized in order to maximize the keratinized tissue healing around dental implants. The aim of this study is to compare the soft tissue healing pattern between two different suture techniques after implant placement. Materials and Methods: 15 patients with 18 implants were enrolled in this study. Simple implant placement without any additional bone graft was performed. Two different suture techniques were used to tug in the mobilized flap near the healing abutment after paramarginal flap design. Digital intraoral scan was performed at baseline, post-operation, stitch out, and 3 months after operation. The scan data were aligned using multiple points such as cusp, fossa of adjacent teeth, and/or healing abutment. After subtracting scan data at baseline with other time-point results, closed space indicating volume increment of peri-implant mucosa was selected. The volume of the close space was measured in mm3. The volume between two suture techniques at three time-points was compared using nonparametric rank-based analysis. Results: Healing was uneventful in both groups. Both suture technique groups showed increased soft tissue volume immediately after surgery. The amount of volume increment significantly decreased after 3 months (P < 0.001). Flap folding suture group showed higher median of volume increment than interrupted suture group after 3 months without any statistical significance (P > 0.05). Conclusion: After paramarginal flap reflection, the raised flaps stabilized by flap folding suture showed relatively higher volume maintenance after 3-month healing period. However, further studies are warranted.