• Title/Summary/Keyword: Stimulation parameter

Search Result 73, Processing Time 0.032 seconds

Improvement of Stimulus Pattern and Design of Discrimination System for Coincident ratio Elevation with Traditional Meridians (고전경락과의 부합율 향상을 위한 경혈자극방식의 개선 및 식별시스템의 설계)

  • Lee, Yong-Heum;Ko, Su-Bok;Jeong, Dong-Myong
    • Journal of IKEEE
    • /
    • v.7 no.1 s.12
    • /
    • pp.22-31
    • /
    • 2003
  • Conventional stimulus patterns have used DC for discrimination of acupoint and meridian which is the basic object of diagnosis and medical treatment in oriental medicine. Those discriminate conduction points by stimulation on body skin with DC. But, it is insufficient to reliability in discrimination ratio, coincident ratio, body effect, reproductivity. Therefore, this paper has extracted the optimal parameter of frequency and waveform in order to improve conventional pattern, and proposed the SPAC(Single Power Alternative Current) stimulus pattern applying that. Also, We proposes algorithm which is able to discriminate with low pressure of the electrode by displaying in the level meter both the absolution and relation value of the skin current. It can decrease pain and body effect by electrode pressure and discriminate acupoint regardless of skin current in difficult discrimination spot. We have compared the performance of system applying the extracted optimal parameter and algorithm. We have compared discrimination, coincident ratio of both conduction point and traditional acupoints by acupoint stimulation pattern. In the results, we confirmed reliability of SPAC stimulus pattern.

  • PDF

Study on the Characteristic of Eye Movement for Visual Improvement of the Elderly

  • Yu, Mi;Piao, Yong-Jun;Kim, Yong-Yook;Kwon, Tae-Kyu;Hong, Chul-Un;Kim, Nam-Gyun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.202-205
    • /
    • 2005
  • The purpose of this work is to identify the characteristic of eye movement for visual training of the elderly. This investigation is to examine the relationship between the head and the eye motor system for the localization of visual target direction in three-dimensional space. All experiments were performed in a soundproof chamber. Twenty-one red LEDs (Light-Emitting Diode, Brightness: 20cd/$m^2$) arrayed in three lines on a half circle-surrounding panel are used. LEDs are horizontally 30 degree apart and vertically 20 degree apart from each other. The condition of stimulation is random and anti-saccade. Physiological parameter such as EOG (Electro-Oculography) was measured by BIOPAC system. We measure the mean latency time, which is the time from the start of visual stimulation to the response of the human body. The result shows that the mean latency time is short in the case of the condition of anti-saccade, the fixed head and a quarter visual stimulation. This finding can be used in developing programs for various visual improvements for the elderly by analyzing the characteristic of eye movement.

  • PDF

The impact of functional brain change by transcranial direct current stimulation effects concerning circadian rhythm and chronotype (일주기 리듬과 일주기 유형이 경두개 직류전기자극에 의한 뇌기능 변화에 미치는 영향 탐색)

  • Jung, Dawoon;Yoo, Soomin;Lee, Hyunsoo;Han, Sanghoon
    • Korean Journal of Cognitive Science
    • /
    • v.33 no.1
    • /
    • pp.51-75
    • /
    • 2022
  • Transcranial direct current stimulation (tDCS) is a non-invasive brain stimulation that is able to alter neuronal activity in particular brain regions. Many studies have researched how tDCS modulates neuronal activity and reorganizes neural networks. However it is difficult to conclude the effect of brain stimulation because the studies are heterogeneous with respect to the stimulation parameter as well as individual difference. It is not fully in agreement with the effects of brain stimulation. In particular few studies have researched the reason of variability of brain stimulation in response to time so far. The study investigated individual variability of brain stimulation based on circadian rhythm and chronotype. Participants were divided into two groups which are morning type and evening type. The experiment was conducted by Zoom meeting which is video meeting programs. Participants were sent experiment tool which are Muse(EEG device), tdcs device, cell phone and cell phone holder after manuals for experimental equipment were explained. Participants were required to make a phone in frount of a camera so that experimenter can monitor online EEG data. Two participants who was difficult to use experimental devices experimented in a laboratory setting where experimenter set up devices. For all participants the accuracy of 98% was achieved by SVM using leave one out cross validation in classification in the the effects of morning stimulation and the evening stimulation. For morning type, the accuracy of 92% and 96% was achieved in classification in the morning stimulation and the evening stimulation. For evening type, it was 94% accuracy in classification for the effect of brain stimulation in the morning and the evening. Feature importance was different both in classification in the morning stimulation and the evening stimulation for morning type and evening type. Results indicated that the effect of brain stimulation can be explained with brain state and trait. Our study results noted that the tDCS protocol for target state is manipulated by individual differences as well as target state.

Computer simulation to determine system parameters of the square-wave adapted fast impedance analyzer for the electrode - electrolyte interface analysis (구형파를 이용한 전극계면 분석용 고속 임피던스 분석기의 설계변수 확정을 위한 컴퓨터 시뮬레이션)

  • Kim Gi-Ryon;Kim Gwang-Nyeon;Shim Yoon-Bo;Jeon Gye-Rok;Jung Dong-Keun
    • Journal of the Korea Society for Simulation
    • /
    • v.14 no.2
    • /
    • pp.45-55
    • /
    • 2005
  • There are electric double layer capacitance, polarization resistance and solution resistance in the interface between electrode and solution. Electrode process could be evaluated by the electrical impedance analysis. The necessities of the electrochemical cell analysis with high speed impedance analyzer are followings: minimization of the effects of electric stimulation on electrochemical cell and the concentration of reactive materials, and optimization of impedance signal resolution. This paper represents the design criteria for the selection and stimulation to develop fast impedance analyzer prototype for a electrochemical cell. It was suggested that the design of 470k sample/s sampling rate, 13 bit ABC resolution, and 140ms recording time is required for high speed impedance analysis system in frequency range between dc and 10kHz.

  • PDF

Fundamental Small-signal Modeling of Li-ion Batteries and a Parameter Evaluation Using Levy's Method

  • Zhang, Xiaoqiang;Zhang, Mao;Zhang, Weiping
    • Journal of Power Electronics
    • /
    • v.17 no.2
    • /
    • pp.501-513
    • /
    • 2017
  • The fundamental small-signal modeling of lithium-ion (Li-ion) batteries and a parameter evaluation approach are investigated in this study to describe the dynamic behaviors of small signals accurately. The main contributions of the study are as follows. 1) The operational principle of the small signals of Li-ion batteries is revealed to prove that the sinusoidal voltage response of a Li-ion battery is a result of a sinusoidal current stimulation of an AC small signals. 2) Three small-signal measurement conditions, namely stability, causality, and linearity, are proved mathematically proven to ensure the validity of the frequency response of the experimental data. 3) Based on the internal structure and electrochemical operational mechanism of the battery, an AC small-signal model is established to depict its dynamic behaviors. 4) A classical least-squares curve fitting for experimental data, referred as Levy's method, are introduced and developed to identify small-signal model parameters. Experimental and simulation results show that the measured frequency response data fit well within reading accuracy of the simulated results; moreover, the small-signal parameters identified by Levy's method are remarkably close to the measured parameters. Although the fundamental and parameter evaluation approaches are discussed for Li-ion batteries, they are expected to be applicable for other batteries.

The Effects of the Stimulation Intensity and Inter-Electrode Distance on the Parameters of the Measured Sensory Nerve Signal (전기자극의 강도와 측정전극의 간격이 감각신경신호의 파라미터에 미치는 영향 연구)

  • Lim, Kyeong Min;Song, Tongjin
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.6
    • /
    • pp.234-241
    • /
    • 2014
  • This study was designed to investigate the effects of stimulation intensity and inter-electrode distance on the parameters of the measured sensory nerve signal. 30 healthy subjects participated in this study. Sensory nerve signals were elicited by four different pulse amplitudes, i.e., 3, 6, 9, 12 mA, with the pulse width fixed at $500{\mu}s$. The sensory nerve signals elicited by the four different pulse amplitudes were measured by four different inter-electrode distances (20, 30, 40, and 50 mm). We extracted four parameters (pulse amplitude, pulse width, pulse area, and latency time from stimulation) from the sensory nerve signals. The measured pulse amplitude and pulse width were increased when the measuring inter-electrode distance was increased while the stimulating pulse amplitude was fixed. The measured pulse amplitude was saturated with the stimulating pulse amplitudes of over 6 mA while measuring inter-electrode distance. Under the same condition, measured pulse width was increased, and sensory nerve signal was initiated early. Sensory nerve signals, specially those of pulse amplitude, were distorted by a differential amplification method that commonly measures the human body signal. The experimental results indicate that the differential amplification method is required to be replaced when measuring nerve signals. Our observations suggested that the hyperpolarization of the action potential of the sensory nerve signal for preventing distortion could be used to clarify the correlation between the parameters of the sensory nerve signals and quantification of sensations.

Changes in Shoot and Root Growth of Tomato Seedlings Stimulated by Brushing (브러싱 자극 토마토 공정묘의 지상부와 지하부 생육 변화)

  • Hyeon Woo Jeong;Hee Sung Hwang;Seung Jae Hwang
    • Journal of Bio-Environment Control
    • /
    • v.32 no.3
    • /
    • pp.205-209
    • /
    • 2023
  • Mechanical stimulation induce the morphological changes in plants. In this study, we investigated the growth changes of tomato seedlings applicated to mechanical stimulation. The brushing treatment was used for mechanical stimulation. The brushing treatment interval was 2 hr using transfer device attached acrylic film from 10 days after sowing. Growth parameter of tomato seedlings were measured 3-day intervals to investigate the growth changes during brushing treatment. The plant height and leaf area were decreased in brushing treatment than the control, and the fresh and dry weights of shoot didn't have significant difference in the control and brushing treatment. The total root length and root surface area were increased in brushing treatment compared than the control, and root volume has no significant difference in the control and brushing treatment. In conclusion, these results suggest that the application of brushing treatment on tomato seedling make shorten plant height and well-development root morphological characteristics.

Extraction of Parameters for Acupoint Discrimination and Design of discrimination system (경혈식별을 위한 파라메터 추출 및 식별시스템의 설계)

  • 이용흠;박창규
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.1
    • /
    • pp.89-101
    • /
    • 2001
  • The conventional pattern-methods for discrimination of acupoint, meridian line which is the basic object of diagnosis and medical treatment in oriental medicine is discriminated the conduction point by the stimulation in body skin with DC. But, it is not sufficient to truth in discrimination ratio, coincident ratio, body effect, reproductivity. Therefore, this paper is extracting the optimal parameter of frequency and waveform in order to improve the conventional pattern, and proposing the SPAC(Single Power Alternative Current) stimulus pattern applying that. Also, this algorithm proposes to be able to discriminate with low pressure of the electrode by displaying in the level meter both the absolution and relation value of the skin current. It is able to decrease pain and body effect by electrode pressure and discriminate acupoint regardless of skin current in difficult discrimination spot. It is compared the performance of system applying the extracted optimal parameter and algorithm, and it is confirmed that there is difference in discrimination parameter of acupoint reacted to the individual and the meridian. It is compared that discrimination, coincident ratio of the traditional acupoints as the acupoint stimulation pattern. It is confirmed truth of optimal parameter and discrimination algorithm. Keyword: Meridian, Discrimination, Coincident, Body effect, Reproductivity, SPAC, Optimal parameter.

  • PDF

Simulation of the Effect of Protein Quality at the Different Protein Intake Level on Protein Metabolism (각기 다른 단백질섭취 수준에서 본 식이단백질의 질이 단백질대사에 미치는 영향 -Simulation Model을 이용하여-)

  • 이옥희
    • Journal of Nutrition and Health
    • /
    • v.26 no.9
    • /
    • pp.1033-1048
    • /
    • 1993
  • This study was designed to describe the effect of the protein quality at different intake level of protein on the protein metabolism in the whole body of growing pigs with a simulation model. Varying to the protein level in feeds, four simulations were conducted. The feed protein level, represented as proportions of digestible protein to the metabolic energy (DP/ME, g/MJ), were 6-8, 11-13, 17-19, and 23-25 DP/ME, respectively. Two protein quality and six weeks of growth time were used at each simulation. The objective function for the simulations was protein deposition in the whole body, which was calculated from the experimental results. The parameters in the simulation were determined by the parameter estimation technique. The results obtained from the simulation were as follows: The protein synthesis and breakdown rates(g/day) in the whole body was increased with the increase of protein quality only at lower or required level of protein intake. They showed a parallel behavior in the course of growth, irrespective of quality and level of feed protein intake. The simulated protein deposition and protein synthesis showed a linear relationship between them at different protein quality and level. The affinity parameter showed a linear relationship between them at different protein quality and level. The affinity parameter showed that arginine, tryptophan and isoleucine were more efficient in the stimulation ofbody protein synthesis. Lysine and phenylalanine+tyrosine were less efficient. The oxidation parameter showed that histidine, pheyalanine+tyrosine were less efficient. The oxidation parameter showed that histidine, phenyalanine+tyrosine, and methionine+cystine were oxidized in larger magnitude than lysine and threonine. The oxidation parameter of most amino acids increased with the increase of protein intake beyond the requirement level, but not any more at highest protein intake level. Finally it was found that the improvement of feed protein quality at the lower or required level of protein intake increase protein deposition through a parallel increase of protein synthesis and breakdown.

  • PDF

Development of Parameter for Measuring Quantitative Engineering Ergonomics Character (정량화된 감성지표 측정을 위한 파라미터 개발)

  • Yoo, Byong-Wook;In, Jun-Hwan;Kim, Seung-Keyum;Kim, Chang-Seok
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.37 no.1
    • /
    • pp.79-88
    • /
    • 2000
  • In this paper, assuming the ergonomics estimate index parameter from the evoked potential of the object stimulation by the continuance time and the amplitude of the ergonomics, the continuance time and the amplitude of the ergonomics were estimated by applying the Prony model to ergonomics. As a result of analyzing ergonomics, band characteristics could be classified, ergonomics of the impatient, rage and fear could be classified by assuming the continuance time and the amplitude of ergonomics, the estimated parameter could be practicable to the ergonomics estimate index.

  • PDF