• 제목/요약/키워드: Still Fluid

검색결과 266건 처리시간 0.022초

Chorioamnionitis: Is a major player in the development of bronchopulmonary dysplasia?

  • Choi, Chang Won
    • Clinical and Experimental Pediatrics
    • /
    • 제60권7호
    • /
    • pp.203-207
    • /
    • 2017
  • Chorioamnionitis is an inflammation in the fetal membranes or placenta. When chorioamnionitis develops, fetal lungs are exposed to inflammatory cytokines and mediators via amniotic fluid. Because inflammation plays a pivotal role in the development of bronchopulmonary dysplasia (BPD), a chronic lung disease of prematurity, fetal lung inflammation induced by chorioamnionitis has been considered to be one of the major pathogenetic factors for BPD. Although there have been a number of studies that demonstrated the relationship between chorioamnionitis and BPD, there are still controversies on this issue. The controversies on the relationship between chorioamnionitis and BPD arise from not-unified definitions of chorioamnionitis and BPD, different study populations, and the proportion of contribution between inflammation and infectious microorganisms. The publication bias also contributes to the controversies. Clinical trials targeting chorioamnionitis or microorganisms that cause chorioamnionitis will answer on the actual relationship between chorioamnionitis and BPD and provide a novel prophylactic strategy against BPD based on that relationship.

무장분리 안전성을 위한 전산해석 (CFD ANALYSIS ON AIRCRAFT STORE SEPARATION VALIDATION)

  • 정형석;윤용현;이상현
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2007년도 춘계 학술대회논문집
    • /
    • pp.14-16
    • /
    • 2007
  • A critical problem in the integration of stores into new and existing aircraft is the safe separation of the stores from the aircraft at a variety of flight conditions representative of the aircraft flight regime. Typically, the certification of a particular store/aircraft/flight condition combination is accomplished by a flight test. Flight tests are very expensive and do expose the pilot and aircraft to a certain amount of risk. Wind tunnel testing, although less expensive than flight testing, is still expensive. Computational Fluid Dynamics(CFD) has held out the promise of alleviating expensive and risk by simulating weapons separation computationally. The forces and moments on a store at carriage and at various points in the flow field of te aircraft can be computed using CFD applied to the full aircraft and store geometry. This study needs full dynamic characteristics study and flow analysis for securing store separation safety. Present study performs dynamic simulation of store separation with flow analysis using Chimera grid scheme which is usually used for moving simulations.

  • PDF

유체 슬로싱모드가 탱크의 진동에 미치는 영향에 대한 연구 (A Study on Vibration Characteristics with Sloshing Mode Effect in Water Tank Structure)

  • 배성용
    • 대한조선학회논문집
    • /
    • 제40권6호
    • /
    • pp.88-95
    • /
    • 2003
  • Liquid storage rectangular tank structures are used in many fields of airplane and marine engineering. Fatigue damages are sometimes observed in these tanks which seem to be caused by resonance. Therefore it is essentially important to estimate vibration characteristics of tank structures. Many Investigators studied the vibration of cylindrical and rectangular tank structures containing still fluid. In general, the eigenbehavior of interior liquid is characterized by the sloshing mode while that of the structure by the bulging mode. However, the structure deformation to the sloshing mode and the liquid free-surface fluctuation to the bulging mode have been neglected in the classical added-mass computation. in the present paper, we study the vibration characteristics with sloshing mode effect.

부압을 이용한 매연저감장치의 실험적 연구 (An Experimental Study of Smoke Reduction System using Vacuum)

  • 함성훈;권영웅;오세훈;박성천
    • 한국철도학회논문집
    • /
    • 제12권5호
    • /
    • pp.714-718
    • /
    • 2009
  • 지난 수년간 디젤엔진의 성능을 지배하는 인자를 도출하기 위한 많은 연구가 이루어 졌다. 디젤엔진의 배출물은 대기 환경오염의 주원인으로 많은 나라에서 관심의 대상이 되고 있다. 본 연구에서는 새로운 디젤엔진의 매연 저감 시스템을 제안하고자 한다. 이 새로운 시스템은 매연을 포집하기 위해 부압장치와 수분이 포함된 필터를 사용하였다. 새로운 시스템을 검증하기 위하여 디젤 차량의 실차 성능실험을 하였고, 그 결과 매연저감을 확인 할 수 있었다.

말의 활액 및 혈청 분석을 통한 관절질환의 생화학적 예측 인자 (The Investigation of Synovial Fluid and Serum for Biochemical Markers of Joint Diseases in the Horse)

  • 배종환;김갑수;유영춘;이회영;이경복
    • 한국임상수의학회지
    • /
    • 제18권3호
    • /
    • pp.304-310
    • /
    • 2001
  • The joint disease including osteoarthris (OA) and rheumatoid arthritis (RA) are common in the horse. Many studies have been performed to develop biochemical markers reflecting the abnormalities of cartilage and synovial membrane. However, no specific, sensitive and clinically well established assay systems have been yet available to characterize the severity of joint diseases. Indeed, radiography is still doctor's best choice of assessing joint damage in OA/RA. This review focuses on biochemical molecules such as proteoglycan, collagen, matrix metalloproteinases (MMPs), lectin and cytokine to assess their potential value for not only predicting stage of joint disease but also monitoring treatment efficacy.

  • PDF

A case of Kawasaki disease with coexistence of a parapharyngeal abscess requiring incision and drainage

  • Choi, Se-Hyun;Kim, Hyun-Jung
    • Clinical and Experimental Pediatrics
    • /
    • 제53권9호
    • /
    • pp.855-858
    • /
    • 2010
  • Kawasaki disease (KD) causes multisystemic vasculitis but infrequently manifests with deep neck infections, such as a peritonsillar abscess, peritonsillar or deep neck cellulitis, suppurative parapharyngeal infection, or retropharyngeal abscess. As its etiology is still unknown, the diagnosis is usually made based on typical symptoms. The differential diagnosis between KD and deep neck infections is important, considering the variable head and neck manifestations of KD. There are several reports on KD patients who were initially diagnosed with retropharyngeal abscess on on computed tomography scans (CT). However, the previously reported cases did not have abscess or fluid collection on retropharyngeal aspiration. Therefore, false-positive neck CT scans have been obtained, until recently. In this case, suspected neck abscess in patients with KD unresponsive to intravenous immunoglobulin could signal the possible coexistence of suppurative cervical lymphadenitis.

Pathophysiological Roles of AMP in Hypertrophied Heart

  • Chunhua Cao;Han, Jeong-Hee;Kim, Sung-Zoo;Cho, Kyung-Woo;Kim, Suhn-Hee
    • 한국생물물리학회:학술대회논문집
    • /
    • 한국생물물리학회 2003년도 정기총회 및 학술발표회
    • /
    • pp.31-31
    • /
    • 2003
  • Cardiac atrium is now well-known as an endocrine organ which secretes atrial natriuretic peptide (AMP), participating in the regulation of body fluid and blood pressure. ANP is released mainly from cardiac muscle cells in response to various physiological and pathological conditions to induce atrial stretch. Ca$\^$2+/ may be one of the most important factors affecting ANP secretion even though controversy still persists. The aim of the present study is to investigate the effect of lysophosphatidylcholines (LPCs) and moxonidine on atrial hemodynamics and ANP secretion in hypertrophied atria. LPC is an endogenous phospholipid released from cell membrane during ischemia, and moxonidine is a imidazoline 1 (Il) receptor agonoist.

  • PDF

DMA를 이용한 나노 입자의 크기 분류법에 대한 이해와 성능개선 (Understanding Size Selection of Nanoparticles Using a Differential Mobility Analyzer (DMA) and Its Performance Enhancement)

  • 김석환;김상욱;이동근
    • 한국입자에어로졸학회지
    • /
    • 제10권1호
    • /
    • pp.33-43
    • /
    • 2014
  • A differential mobility analyzer (DMA) has been widely used as a standard tool for classifying nanoparticles with a certain size. More recently, several new types of DMA have been tested in an attempt to produce size-monodisperse nanoparticles. It is a bit surprise to see how simple the working theory of the DMA is. Although the theory was demonstrated quite successful, no one can guarantee whether the theory still works in another geometry of the DMA. In this regard, we first investigated the validity of the theory under various working conditions and then moved to check the validity upon minor change in its design. For the valid test, we compared the results with those obtained from a computational fluid dynamics.

토크모터의 정특성과 동특성 해석 (An Analysis of Static and Dynamic Characteristics of Torque Motor)

  • 허준영;박창순
    • 드라이브 ㆍ 컨트롤
    • /
    • 제12권1호
    • /
    • pp.9-14
    • /
    • 2015
  • In the early of 1950, the high response magnetic torque motor was developed for driving electro-hydraulic servo valves. Since then it has been broadly used for industrial application and the research of development or improvement of the torque motor is still being conducted. The purpose of this study is to present useful design criteria for the torque motor design. For this, torque motor is modelled and linearized. The static characteristics of the torque motor are investigated by direct computation of the derived linearlized equations. The dynamic characteristics of the torque motor are investigated with the derived transfer function by using Matlab and compared with the results of the linearlized analysis by using AMESim simulation with actual values of the physical parameters. Finally, the design criteria obtained from the analysis are reviewed.

드레인 오리피스를 갖는 포펫 밸브의 상대 안정도에 관한 연구 (A Study on Relative Stability for Poppet Valve with Drain Orifice)

  • 윤소남;정황훈;서정균;함영복
    • 유공압시스템학회:학술대회논문집
    • /
    • 유공압시스템학회 2010년도 춘계학술대회
    • /
    • pp.12-17
    • /
    • 2010
  • The poppet valve had used every field area due to high quality of leakage property and response characteristic. But this valve still has terrible disadvantage that is self-exited vibration. This problem affects stability of total system and raises noise. The researcher tries to reduce that self-exited vibration when valve was designed. The stability discriminant is the typical study to improve the performance of the poppet valve. This paper concerns about stability discriminant that uses poppet valve with a drain orifice. At the first, the mathematical model is computed from poppet valve. After that, the limitation of stability is calculated that based on Nyquist criterion. At the final, the stability discriminant is selected in each condition and the graph that shows stability in the system is drown by dimensionless quantity.

  • PDF