• Title/Summary/Keyword: Step-down method

Search Result 183, Processing Time 0.025 seconds

A Study on Changes in Trends of Disease of Residents Who Received Treatment at Nam Jeju County Primary Health Care Post(1997~2003) (남제주군 보건진료소 이용 주민의 상병양상변화 고찰(1997년~2003년))

  • Kang, Na-Yon
    • Journal of Korean Academy of Rural Health Nursing
    • /
    • v.2 no.2
    • /
    • pp.133-144
    • /
    • 2007
  • Purpose: The purpose of this study was to examine the trends of disease of residents who had treatment in primary health care posts in N-county over the past seven years (1997-2003). The data will assist in planning responses to changes in the health care environment and in planning health promotion programs. Method: A retrospective descriptive survey was conducted of the computerized records of primary health care done by community health practitioners over the last seven years. Cross analysis was conducted among the data using SAS, and the results were displayed in frequencies and percentages. The data were collected from May to September 2004. Results: The results of the study are as follows: 1. The six most frequent diseases were ranked as follows: diseases of the 1) respiratory system, 2) musculoskeletal system and connective tissue, 3) digestive system, 4) skin and subcutaneous tissue, 5) circulatory system, and 6) symptoms, signs and abnormal clinical and laboratory findings. Especially in 2002, circulatory system related disease rose two steps in the ranking and digestive system related disease went a step down. 2. The patients' use of primary health care posts over the past seven years continued to increase on the whole. Conclusions: According to these results, each primary health care post should carry out special health promotion programs that fit the local society of N- county and are in accordance with changes in health care needs.

Development of an Exercise Program for Postmastectomy Patient (유방절제술 환자를 위한 운동프로그램 개발)

  • Lee, Ja-Hyung;Cho, Jae-Kyung;Oh, Ji-Na;Kim, Sung-Hee;Ahn, Hye-Im
    • Women's Health Nursing
    • /
    • v.10 no.4
    • /
    • pp.301-310
    • /
    • 2004
  • Purpose: The purpose of this study was to develop an exercise program for postmastectomy patients. Method: This study was conducted from October, 2003 to June, 2004. The exercise program was developed based on literature review and needs assessment using focus group interviews. The subjects for the focus group interview consisted of 11 patients, 13 recovering patients, and 20 nurses from 3 hospitals. Development of the program was proceeded with analysusm design and development steps. Result: The results of the needs assessment using the focus group interview showed that the exercise program was imperative for postmastectomy patients. Based on the results, a home video tape containing 3 steps, was developed. Each step includes warming-up, stretching, the main exercise, and cool-down. Steps 2 and 3 include exercises with an elastic band, and an elastic ball. The program was modified after conducting a pre-test. A self-checklist including shoulder mobility, hand strength, arm volume and subjective comments on how they feel will be used before and after the exercise program. Conclusion: The exercise program will improve breast cancer patients' quality of life and their physical well-being. Further studies are recommended to test the effectiveness of the exercise program.

  • PDF

MBE growth of topological insulator $Bi_2Se_3$ films on Si(111) substrate

  • Kim, Yong-Seung;Bansa, Namrata;Edrey, Eliav;Brahlek, Mathew;Horibe, Yoichi;Iida, Keiko;Tanimura, Makoto;Li, Guo-Hong;Feng, Tian;Lee, Hang-Dong;Gustafsson, Torgny;Andrei, Eva;Cheong, Sang-Wook;Oh, Seong-Shik
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.59-59
    • /
    • 2011
  • We will report atomically sharp epitaxial growth of $Bi_2Se_3$ three-dimensional topological insulator films on Si(111) substrate with molecular beam epitaxy (MBE). It was achieved by employing two step growth temperatures to prevent any formation of second phase, like as $SiSe_2$ clusters, between $Bi_2Se_3$ and Si substrate at the early stage of growth. The growth rate was determined completely by Bi flux and the Bi:Se flux ratio was kept ~1:15. The second-phase-free atomically sharp interface was verified by RHEED, TEM and XRD. Based on the RHEED analysis, the lattice constant of $Bi_2Se_3$ relaxed to its bulk value during the first quintuple layer implying the absence of strain from the substrate. Single-crystalline XRD peaks of $Bi_2Se_3$ were observed in films as thin as 4 QL. TEM shows full epitaxial structure of $Bi_2Se_3$ film down to the first quintuple layer without any second phases. This growth method was used to grow high quality epitaxial $Bi_2Se_3$ films from 3 QL to 3600 QL. The magneto-transport properties of these thin films show a robust 2D surface state which is thickness independent.

  • PDF

An Experimental Study on the Ventilation Performance to Enhance Removal Efficiency of Indoor Hamful Gases (실내 유해가스 제거효율 향상을 위한 환기성능에 관한 실험적 연구)

  • Ku, Jae-Hyun
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.117-124
    • /
    • 2009
  • The objective of this research is to analyze the ventilation performance of mechanical ventilation systems to enhance removal efficiency of indoor hamful gases. The ventilation performance is evaluated using a step-down method based on ASTM Standard E741-83. The ventilation performance is evaluated as a function of the ventilation rate and supply/extract locations using a tracer gas ($CO_2$) technique. As a result, the $CO_2$ concentration as a function of time is decayed exponentially and the ventilation performance is found to increase with increased the ventilation rate. The ventilation performance of the second type ventilation system is better than that of the first type or the third type. The ventilation performance without human occupancy increases up to 55% and the ventilation performance with one person increases up to 25% at the supply air of 570Lpm comparing with a natural reduction after one hour in the test chamber. The ventilation performance is better than 15% comparing with natural decay at the supply of 570Lpm in an office room.

A Simulation Investigation on the Spurious Emission Reduction of the Automotive DC-DC Converter (자동차용 DC-DC 컨버터의 전자파 방사 감소 방법에 대한 시뮬레이션 연구)

  • Chae, Gyoo-Soo
    • Journal of Convergence for Information Technology
    • /
    • v.10 no.8
    • /
    • pp.47-52
    • /
    • 2020
  • In this study, a simulation investigation was conducted on the method of reducing switching noise and spurious emission among design methods for step-down DC-DC converter modules for automotive. A typical 4-layer converter circuit using a PMIC(Power Management Integrated Circuit) chip was presented, and the simulation results of conductive emissions at two input terminals (+, -) and the point between the input filter and the PMIC was performed in the 1.0~5.0MHz band and the 100MHz band. The results for the conducted and radiated emissions in the HF(3~30MHz) and VHF(30-300MHz) bands were presented. It showed an improvement of about 10dB over the bands by routing the output terminal placed on the 3 or 4-layer in the opposite direction to the input terminal. The result of this study is expected to be useful in the design of the DC-DC converter modules in the future because it gives a better improvement compared to the existing methods.

Nipple Reconstruction with the Double Opposing Plow Flap: A Case Report (이중 대립 쟁기피판을 이용한 유두 재건술: 증례보고)

  • Heo, Chan Yeong;Eun, Seok Chan;Baek, Rong Min;Minn, Kyung Won
    • Archives of Plastic Surgery
    • /
    • v.34 no.4
    • /
    • pp.490-492
    • /
    • 2007
  • Purpose: Nipple reconstruction is an important step in breast reconstruction after mastectomy. There are considerable number of reconstructive methods developed over the past years. Each of these has not only its own special advantages, but also limitations. Therefore, no single method has become the overwhelming favorite. Sometimes it seems to be compromised when the nipple must be located directly over a linear scar. Methods: A 48-year-old female patient received a central lumpectomy with circumareolar resection of the nipple areolar complex 4 months ago. The newly designed nipple must be positioned directly astride a scar. We drew two equal-sized rectangular flaps sharing a common limb on a transverse scar and the result was two opposing plow form. Each flap size was about 1.3 cm wide and 2.5 cm long. First we elevated the flap from the distal part at a deep dermal plane, then deepened the level of dissection to raise the dermal-fat flaps. The donor site could be closed directly without any dog-ear deformity. Then we folded down the elevated flaps and loosely sutured skin with nonabsorbable materials. Each flap inner side was approximated side by side. Finally we made new natural nipple with 6 mm projection. We applied tattooing in the areola area with micropigmentation device after three months. Results: After ten months of follow-up periods, the nipple projection was stable and symmetric. The nipple projection was 3.1 mm, compared with 2.8 mm for the opposite nipple. Conclusion: Our experiences shows that this double opposing plow flap is a particularly useful and simple technique when there is a traverse scar crossing the center of the proposed nipple area.

Correlation Analysis of Pelvic Tilt and Gait according to the Paralytic Side of Stroke Patients (뇌졸중 환자의 마비쪽에 따른 골반의 기울임과 보행의 상관관계 분석)

  • Yong Seon, Lee;Jong-Hyuk, Yun
    • Korean Journal of Applied Biomechanics
    • /
    • v.32 no.4
    • /
    • pp.111-120
    • /
    • 2022
  • Objective: This study investigated the effect of pelvic tiltng according to the paralytic side on gait in stroke patients during a 10 m functional movement timed up and go (TUG) test. Method: In this study, gait parameters were measured using a gait analyzer for 20 stroke patients and their gait was analyzed during a 10 m TUG test. For statistical analysis, an independent sample t-test were performed for age, height, and weight among general characteristics of subjects and homogeneity was tested by performing a chi-square test for gender, paralysis side, period of onset, and K-MMSE score. In order to understand the relationship between each variable, Pearson correlation analysis was performed on the variables. Results: First, the right-hand paralyzed group showed correlations in cadence and gait velocity in the up and down tilt of the pelvis, and the left-hand paralyzed group showed correlations in cadence and step length in the anterior and posterior tilt of the pelvis. Second, the tilt of the pelvis was correlated with the Sit to stand, walk forward, walk backwards, turn around at the end point, sit on a chair and the total TUG time in the right hemiplegic group compared to the left hemiplegic group. Conclusion: In this study, a significant correlation was confirmed as a result of gait analysis of right-handed stroke patients divided into a right paraplegic group and a left paraplegic group. In the future, it is suggested that treatment for improving gait of stroke patients should be treated differently for the right and left paralyzed side.

The Effect of Mask Patterns on Microwire Formation in p-type Silicon (P-형 실리콘에서 마이크로 와이어 형성에 미치는 마스크 패턴의 영향)

  • Kim, Jae-Hyun;Kim, Kang-Pil;Lyu, Hong-Kun;Woo, Sung-Ho;Seo, Hong-Seok;Lee, Jung-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.418-418
    • /
    • 2008
  • The electrochemical etching of silicon in HF-based solutions is known to form various types of porous structures. Porous structures are generally classified into three categories according to pore sizes: micropore (below 2 nm in size), mesopore (2 ~ 50 nm), and macropore (above 50 nm). Recently, the formation of macropores has attracted increasing interest because of their promising characteristics for an wide scope of applications such as microelectromechanical systems (MEMS), chemical sensors, biotechnology, photonic crystals, and photovoltaic application. One of the promising applications of macropores is in the field of MEMS. Anisotropic etching is essential step for fabrication of MEMS. Conventional wet etching has advantages such as low processing cost and high throughput, but it is unsuitable to fabricate high-aspect-ratio structures with vertical sidewalls due to its inherent etching characteristics along certain crystal orientations. Reactive ion dry etching is another technique of anisotropic etching. This has excellent ability to fabricate high-aspect-ratio structures with vertical sidewalls and high accuracy. However, its high processing cost is one of the bottlenecks for widely successful commercialization of MEMS. In contrast, by using electrochemical etching method together with pre-patterning by lithographic step, regular macropore arrays with very high-aspect-ratio up to 250 can be obtained. The formed macropores have very smooth surface and side, unlike deep reactive ion etching where surfaces are damaged and wavy. Especially, to make vertical microwire or nanowire arrays (aspect ratio = over 1:100) on silicon wafer with top-down photolithography, it is very difficult to fabricate them with conventional dry etching. The electrochemical etching is the most proper candidate to do it. The pillar structures are demonstrated for n-type silicon and the formation mechanism is well explained, while such a experimental results are few for p-type silicon. In this report, In order to understand the roles played by the kinds of etching solution and mask patterns in the formation of microwire arrays, we have undertaken a systematic study of the solvent effects in mixtures of HF, dimethyl sulfoxide (DMSO), iso-propanol, and mixtures of HF with water on the structure formation on monocrystalline p-type silicon with a resistivity with 10 ~ 20 $\Omega{\cdot}cm$. The different morphological results are presented according to mask patterns and etching solutions.

  • PDF

The Design of 32 Bit Microprocessor for Sequence Control Using FPGA (FPGA를 이용한 시퀀스 제어용 32비트 마이크로프로세서 설계)

  • Yang, Oh
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.40 no.6
    • /
    • pp.431-441
    • /
    • 2003
  • This paper presents the design of 32 bit microprocessor for a sequence control using a field programmable gate array(FPGA). The microprocessor was designed by a VHDL with top down method, the program memory was separated from the data memory for high speed execution of sequence instructions. Therefore it was possible that sequence instructions could be operated at the same time during the instruction fetch cycle. In order to reduce the instruction decoding time and the interface time of the data memory interface, an instruction code size was implemented by 32 bits. And the real time debug operation was implemented for easeful debugging the designed processor with a single step run, PC break point run, data memory break point run. Also in this designed microprocessor, pulse instructions, step controllers, master controllers, BM and BCD type arithmetic instructions, barrel shift instructions were implemented for sequence logic control. The FPGA was synthesized under a Xilinx's Foundation 4.2i Project Manager using a V600EHQ240 which contains 600,000 gates. Finally simulation and experiment were successfully performed respectively. For showing good performance, the designed microprocessor for the sequence logic control was compared with the H8S/2148 microprocessor which contained many bit instructions for sequence logic control. The designed processor for the sequence logic showed good performance.

TALEN Constructs and Validation for Targeting of SETDB1 Genomic DNA (SETDB1 genomic DNA 를 표적하는 TALEN construct 제작 및 분석)

  • Noh, Hee-Jung;Kang, Yoonsung;Kim, Keun-Cheol
    • Journal of Life Science
    • /
    • v.24 no.12
    • /
    • pp.1269-1275
    • /
    • 2014
  • TALEN is a newly developed gene engineering method to knock out specific genes. It contains a DNA binding domain and a Fok1 nuclease domain in the TALEN plasmid. Therefore, the engineered TALEN construct can bind to any region of genomic DNA and cut the target nucleotide, thereby inducing mutation. In this study, we constructed two TALEN constructs targeted to a protein initiation codon (DBEX2) or the 25th upstream region (DBPR25) to enable mRNA synthesis of SETDB1 HMTase. We performed the TALEN cloning in two steps. The first step was from module vectors to pFUS array vectors. We confirmed successful cloning with a colony PCR experiment and Esp31 restriction enzyme digestion, which resulted in a smear band and a 1 Kb insert band, respectively The second step of the cloning was from a pFUS array vector to a mammalian TALEN expression vector. The engineered TALEN construct was sequenced with specific primers in an expression vector. As expected, a specific array from the module vectors was shown in the sequencing analysis. The specific module sequences were regularly arrayed in every 100 bp, and SETDB1 expression totally disappeared in the TALEN-DBEX2 transfection. PCR amplification targeting of DBEX2 was performed, and the PCR product was digested with a T7E1 restriction enzyme. The expression of SETDB1 was down-regulated in the TALEN-DBPR25 transfection. Morphological changes were also observed in the two TALEN constructs with transfected HeLa cells. These results suggest that the engineered TALEN constructs in two strategic approaches are very useful to knock-out of the SETDB1 gene and to study gene function.