• Title/Summary/Keyword: Step-by-Step Measurement

Search Result 751, Processing Time 0.036 seconds

A Comparative Analysis between Manufacturing and Transactional/Service Processes of Six Sigma Quality Improvement (제조부문과 사무간접/서비스부문의 6시그마 프로세스 개선활동 비교분석)

  • Yoon, Jae-Wook;Kim, Bo-Hyoung
    • Journal of Korean Society for Quality Management
    • /
    • v.36 no.4
    • /
    • pp.37-46
    • /
    • 2008
  • There are big differences in six sigma projects between manufacturing processes and transactional/service processes. This paper analyzed the differences between the two areas by examining 18 six sigma case studies in Korean companies. To characterize six sigma case studies, step-by-step questions and check criteria were developed based on 12 step DMAIC methodology. On the basis of those characterized data, the differences between two areas were analyzed. Significant differences were found in the number of CTQs, validation of measurement systems, methods to determine improvement objectives, the methods to elicit improvement plans and types of control systems. The most significant difference was that statistical tools were widely used in manufacturing processes, but qualitative tools were used in transactional/service processes during improvement phase.

Experimental Study of Two-step Phase-shifting Digital Holography based on the Calculated Intensity of a Reference Wave

  • Li, Jun;Pan, Yang Yang;Li, Jiao sheng;Li, Rong;Zheng, Tao
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.3
    • /
    • pp.230-235
    • /
    • 2014
  • Two-step quadrature phase-shifting digital holography based on the calculated intensity of a reference wave is proposed. In the Mach-Zehnder interferometer (MZI) architecture, the method only records two quadrature-phase holograms, without reference-wave intensity or object-wave intensity measurement, to perform object recoding and reconstruction. When the reference-wave intensity is calculated from the 2D correlation coefficient (CC) method that we presented, the clear reconstruction image can be obtained by some specific algorithm. Its feasibility and validity were verified by a series of experiments with 2D objects and 3D objects. The presented method will be widely used in real-time or dynamic digital holography applications.

Measurement of Principal Stress Direction by Photoelastic Phase Shifting Method (광탄성 위상이동법을 이용한 주응력 방향 측정법)

  • 김명수;김환;백태현
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.12
    • /
    • pp.1982-1989
    • /
    • 2004
  • In photoelasticity, the directions of principal stresses are given by isoclinic fringe patterns. In this study, photoelastic theory is represented by Jones calculus and the photoelastic 8-step phase shifting method is described. A feasibility study using computer simulation is done to get isoclinics from photoelastic fringes of a circular disk under diametral compression. Fringe patterns of the disk are generated from the stress-optic law. The magnitudes of isoclinics obtained from the fringe patterns of computer simulation and experiment are compared with those of theory. The results are close between them. Then, the 8-step phase shifting method is applied to get distributions of isoclinics along the specified lines of a cuved beam plate under tensile load. Experimental results obtained from the phase shifting method were compared with those of finite element analysis (ANSYS). It is confirmed that measurement of isoclinic distributions is possible by use of photoelasitc phase shifting method.

Stress Measurement of a Squarely Perforated Plate by Photoelastic Phase Shifting Method (광탄성 위상이동법에 의한 사각형 구멍주위의 응력해석)

  • Lee C.T.;Park T.G.;Jung J.;Panganiban H.;Chung T.J.;Baek T.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.49-50
    • /
    • 2006
  • Photoelasticity is widely and conveniently used methods for whole field stress analysis. In this paper, 8-step photoelastic phase shifting method was performed by using a multi-purpose polariscope to measure the fringe orders along a specified line on the specimen containing a square hole. The material of the specimen is made of Polycarbonate. The measurement results by 8-step phase shifting method were compared with the those calculated by ABAQUS.

  • PDF

Characteristics of Flow Coefficients in an Engine Cylinder Head with a Quasi-steady Flow Condition by Continuous Variation of the Valve Lift (밸브 양정의 연속 변화에 의한 준정상 유동 조건에서의 엔진 실린더헤드 유량계수 특성)

  • Oh, Dae-San;Lee, Choong-Hoon
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.6
    • /
    • pp.22-27
    • /
    • 2010
  • Flow Coefficients of intake port in an engine cylinder head were measured by a newly designed flow rig. In measuring the flow coefficient with traditional method, the valve lift was manually varied by technician with adjusting a micrometer which is directly connected to the intake valve of the cylinder head. The cam shaft of the cylinder head is directly rotated by a step motor and the valve lift was automatically varied with cam shaft profile in the newly designed flow rig. The measurement of the flow coefficient was automated by rotating the cam shaft with the step motor. Automatic measurement of the flow coefficient could be safely measured by separating a technician from the noise and vibration of the traditional flow rig. Also, the automatic measurement of the flow coefficient reduce the measurement time and provide meaningful statistical data.

A Study on Powder Fire Extinguisher Design with RULA Technique Used (RULA 평가기법을 활용한 분말소화기 디자인 연구)

  • Kang, Chaewoo;Kim, Dueknam
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.2
    • /
    • pp.117-123
    • /
    • 2017
  • This study was intended to find methods of fire extinguishing system designs that can improve the equipment's usability. In this study, the fire suppression experiment through fire extinguishers and the data drawn through the experiment were analyzed, and then the guideline for the improvement of designs was presented. The procedure is as follows. A fire suppression experiment with the use of fire extinguishers was done by 43 average adults. The whole process of the fire suppression was videotaped, and then captured major scenes were analyzed with the use of RULA, a human engineering measurement tool. The analyzed data were divided into 4 steps, and then the guideline for design improvement was presented. The summary of the study is as follows. Step 1, Fire extinguisher distance step. To reduce overload occurring at the process of holding fire extinguishers suddenly, wheels are attached to the body of extinguishers, or pedestals are installed. Step 2, Fire extinguisher transportation step. The length of hose is extended, or fire fighting water is sprayed far, so that overload of legs occurring at the process of travel can be reduced. In addition, the weight of fire extinguisher shouldn't be over 2 kg. Step 3, Safety pin removal stage. Safety pins should be applied with button type, so that excessive posture of lower limbs and excessive twisting of wrists won't happen during safety pin removal process. Besides, safety pins should be designed for easy identification and operation. Step 4, Fire extinguishing agent spraying step. To reduce overload occurring at sudden spraying of fire fighting water, pressure should be increased gradually until high pressure. With the above study results applied to existing fire extinguisher design, it may contribute to reducing any fire damage.

Gate Data Gathering in WiFi-embedded Smart Shoes with Gyro and Acceleration Sensor

  • Jeong, KiMin;Lee, Kyung-chang
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.22 no.4
    • /
    • pp.459-465
    • /
    • 2019
  • There is an increasing interest in health and research on methods for measuring human body information. The importance of continuously observing information such as the step change and the walking speed is increasing. At a person's gait, information about the disease and the currently weakened area can be known. In this paper, gait is measured using wearable walking module built in shoes. We want to make continuous measurement possible by simplifying gait measurement method. This module is designed to receive information of gyro sensor and acceleration sensor. The designed module is capable of WiFi communication and the collected walking information is stored in the server. The information stored in the server is corrected by integrating the acceleration sensor and the gyro sensor value. A band-pass filter was used to reduce the error. This data is categorized by the Gait Finder into walking and waiting states. When walking, each step is divided and stored separately for analysis.

Measures to Generalize the Effect of u-Iearning (유러닝 효과성의 일반화 방안)

  • Ahn, Seong-Hun;Jeong, Young-Sik
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.7
    • /
    • pp.379-389
    • /
    • 2009
  • In this paper, we analyzed the effect of u-learning model school which have been in forced by the Ministry of Education. We suggested a plan which we generalized the effects of u-learning. To analyzed the effects of u-learning, first of all, we set up indexes of u-learning effect - satisfaction measurement, efficacy measurement, the scholastic achievements, possibility of generalization. After we reanalyzed reports of model school and papers of u-learning, we looked for suggestions of the effects u-learning. We draw up a plan which we generalized the effects of u-learning according to suggestions. We devide a plan by 3 steps - introduction step, diffusion step, fixation step and every step by 4 field - policy of u-learning, teaching & learning, quality control, technology. Because we suggested a concrete plan which we generalized the effects of u-learning, we expect to use usefully our plan at school in the future.

The Effectiveness of Ink Foot Print Analysis by Using Pre-post Oriental Medicine Music Therapy on Patient One Case with Cerebral Infarction (뇌경색 환자에게 실행한 한방음악치료 전후(前後)의 Ink foot print analysis 1례)

  • Lee, Seung-Hyun;Park, Kyoung-Su;Shin, Hyun-Dae
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.18 no.3
    • /
    • pp.147-156
    • /
    • 2008
  • Objectives : Oriental Medicine Music Therapy is a new way of treating and preventing various diseases and promoting health by means of music specially picked and designed to produce Qi(氣) fitting to an individual person in the areas of the structure of human body, physiological function, pathological change, diagnosis and treatment. Therefore, it can facilitate the efficiency of the treatment much better and faster than only with herb or acupuncture. Equilibrium between body and mind is its originality. Methods : A 38-year old man came to hospital suffering from left side weakness, dysarthria because of cerebral infarction. After one week's medication in the part of neurology, he was sent to the oriental medicine music therapy center, and he took ten times' medical treatments once a day. Before and after the treatments, implementing 'Ink foot print analysis', as for the movement capacity and walking of left side weakness, these results are acquired. Results and Conclusions : 1. Before the oriental medicine music therapy, except the acceleration and deceleration section, within three meters, a right foot's step was measured 30.55 cm and a left foot was measured 15.2 cm, and the step distance was 15.2 cm. After the 10 times treatments, the right foot's step was 112.6 cm, the left foot's step was 113 cm, and the step distance improved to 51.8 cm. 2. The normal person's average step is about 38 cm, and it could be decreased owing to a decreptitude, pain, fatigue, and the weakness of the legs. In spite of all, from the increased 50 cm step measurement with the patient's body condition, it means that his movement capacity is recovered. 3. In the measurement of walking time, before 10 times treatments, it took 46.35 seconds within 6M, but after the treatments, it increased to 7.47 seconds as same as a normal person's walking speed. 4. In insomnia, and the abnormality of a facial muscle, it shows lots of improvement, and even the accuracy of a pronunciation, but despite of the 10 times treatments, the 'ㄹ(r)' sound placed under a vowel is unclear. 5. Before the 10 times' treatments, he can move the left side shoulder with pain and cannot move below the left elbow. After the treatments, the pain was disappeared, and he was able to move over 60 cm without pain. And improving of the movement of fingers, he can beat over 8 times with a drumstick.

P(3HB) Accumulation in Alcaligenes eutrophus H16(ATCC 17699) under Nutrient-Rich Condition and Its Induced Production from Saccharides and Their Derivatives

  • Song, Jae-Jun;Shin, Yong-Chul
    • Journal of Microbiology and Biotechnology
    • /
    • v.3 no.2
    • /
    • pp.115-122
    • /
    • 1993
  • Poly(3-hydroxybutyrate)(P(3HB)) accumulation under nutrient-rich condition with various amounts of $(NH_4)_2 SO_4$ was systematically investigated. The results of the electron-microscopy and the solvent extraction showed that the P(3HB) accumulation is unavoidable even under nutrient-rich condition. This indicates that in a two-step culture of Alcaligenes eutrophus H16, the researches should be careful in interpreting the data of polyhydroxyalkanoates(PHAs) accumulation in terms of the carbon-source fed in the second step because the two-step culture product contains the P(3HB) produced under nutrient-rich condition. The polyester production capability in a two-step batch culture of A. eutrophus H16(ATCC 17699) was also investigated using various saccharides and their derivatives such as glucose, fructose, gluconic acid, glucaric acid, sorbitol, lactose, galactose, and mannose. The polyesters synthesized were characterized by 500 MHz$^{1}H-NMR$ spectroscopy, intrinsic viscosity$[\eta]$ measurement in chloroform and differential scanning calorimetry(DSC). 500 MHz $^{1}H-NMR$ analysis showed that all polyesters synthesized generally contained 1~2 mol% of 3HV. Another finding is that the glucose utilization can be increased by changing the autoclaving procedure of the substrate to enhance the P(3HB) production yield up to 46 wt% of P(3HB) in dry cells.

  • PDF