• 제목/요약/키워드: Step-Up Structure

검색결과 229건 처리시간 0.031초

병원의 지식경영 도입방안에 관한 연구 -병원 지식경영 단계모델 구축- (A Study on the Implementation of Knowledge Management in Hospital)

  • 장익선;나정미
    • 경영과정보연구
    • /
    • 제23권
    • /
    • pp.75-97
    • /
    • 2007
  • In the meantime hospital system of Korea has institutionally performed its errand in stable circumstance, however the system now faces with new environment of change of customer's satisfaction, of regime, deepening of competition, and opening market. Under the rapidly and complicatedly changing circumstance, the hospital system is required to promote getting a dominant position in the competition, enhancing outcome, creating value added, and customer satisfaction in both internally and externally likewise other organizations, as they continuously introduce a knowledge management and originate, accumulate, and put the knowledge to practical use. This organization capacity of knowledge management involves a process of management that requires great change of all organizations and individuals and it is brought up through four steps which are Initiation, Propagation, Integration, and Networking. The main factors of successful knowledge management are intension of the chief executive officer(CEO), organizational culture, appraisal and compensation of work, knowledge controlling system, and organizational structure, and each of these five stage has got different characteristic. To be successful by introducing knowledge management, hospital organization should be based on these premises. Not only CEO or the director of a hospital, but also the constituent members should be fully aware of knowledge, the characteristic of knowledge management, and successful factors of this operation. Should understand step-by-step characteristic of knowledge management, therefore able to analyse a situation of specific hospital and see which step corresponds to that hospital. By analysing, constituents should make up for the weak points and ready to move on to next step. CEO or the director of a hospital should be aware of knowledge management as a strategic factor which is able to get a dominant position in the rapidly changing environment, and also it should be firm in the director's intention to introduce the knowledge management into the hospital. By continuously carrying out education and training constituent members, the director of a hospital should promote their interest and participation in knowledge management, and build an organization culture that ultimately creates, accumulates, shares, and put the knowledge to practical use. The hospital organization needs to systematize an institution of objective compensation that corresponds to objective appraisal of knowledge management outcome. The hospital ought to build knowledge controlling system in stages, in order to take the initiative in rapidly changing environment. By considering the characteristic of hospital system, it is required to change the organizational structure into self-managing team which is a sort of horizontal structure that allows members to make decisions and take the responsibility by themselves. The limitation of this study is experimental study. Positive investigation about successful factors of hospital knowledge management and characteristic of each steps is expected with following study.

  • PDF

고전압 변환비의 자려 발진 DC/DC Converter (Self Oscillation DC/DC Converter with High Voltage Step Up Ratio)

  • 정용준;한상규;홍성수;노정욱
    • 전력전자학회논문지
    • /
    • 제14권3호
    • /
    • pp.220-227
    • /
    • 2009
  • 본 논문은 고전압 DC 파워 서플라이 적용을 위한 높은 전환 비의 자려발진 DC/DC 전력 변환 회로에 관한 것으로써, 하나의 스위치, 하나의 인덕터, 그리고 다수개의 캐패시터와 다이오드로 구성된다. 기존의 극성 반전 형DC/DC 컨버터 회로와 비교하여, 고압 변환 트랜스포머 대신에 인덕터를 사용할 수 있어, 자기 소자의 부피 및 크기는 물론 원가저감이 가능하다. 또한 자려 발진(Self Oscillation) 방식을 사용하여 별도의 제어 IC가 필요 없으므로, 회로구성이 대단히 간단하고, 저가격의 전원 회로를 만들 수 있다. 또한 다이오드들의 전압 스트레스가 감소하여 저가격 고성능의 고압 변환장치 구현이 가능하다. 제안된 회로의 동작원리를 설명하고, 타당성을 Simulation 및 실험을 통하여 검증한다.

Novel Single Switch DC-DC Converter for High Step-Up Conversion Ratio

  • Hu, Xuefeng;Gao, Benbao;Huang, Yuanyuan;Chen, Hao
    • Journal of Power Electronics
    • /
    • 제18권3호
    • /
    • pp.662-671
    • /
    • 2018
  • This paper presents a new structure for a step up dc-dc converter, which has several advantageous features. Firstly, the input dc source and the clamped capacitor are connected in series to transfer energy to the load through dual voltage multiplier cells. Therefore, the proposed converter can produce a very high voltage and a high conversion efficiency. Secondly, a double voltage clamped circuit is introduced to the primary side of the coupled inductor. The energy of the leakage inductance of the coupled inductor is recycled and the inrush current problem of the clamped circuits can be shared equally by two synchronous clamped capacitors. Therefore, the voltage spike of the switch tube is solved and the current stress of the diode is reduced. Thirdly, dual voltage multiplier cells can absorb the leakage inductance energy of the secondary side of the coupled inductor to obtain a higher efficiency. Fourthly, the active switch turns on at almost zero current and the reverse-recovery problem of the diodes is alleviated due to the leakage inductance, which further improves the conversion efficiency. The operating principles and a steady-state analysis of the continuous, discontinuous and boundary conduction modes are discussed in detail. Finally, the validity of this topology is confirmed by experimental results.

High Density Silver Nanowire Arrays using Self-ordered Anodic Aluminum Oxide(AAO) Membrane

  • Kim, Yong-Hyun;Han, Young-Hwan;Lee, Hyung-Jik;Lee, Hyung-Bock
    • 한국세라믹학회지
    • /
    • 제45권4호
    • /
    • pp.191-195
    • /
    • 2008
  • Highly ordered silver nanowire with a diameter of 10 nm was arrayed by electroless deposition in a porous anodic aluminum oxide(AAO) membrane. The AAO membrane was fabricated electrochemically in an oxalic acid solution via a two-step anodization process, while growth of the silver nanowire was initiated by using electroless deposition at the long-range-ordered nanochannels of the AAO membrane followed by thermal reduction of a silver nitrate aqueous solution by increasing the temperature up to $350^{\circ}C$ for an hour. An additional electro-chemical procedure was applied after the two-step anodization to control the pore size and channel density of AAO, which enabled us to fabricate highly-ordered silver nanowire on a large scale. Electroless deposition of silver nitrate aqueous solution into the AAO membrane and thermal reduction of silver nanowires was performed by increasing the temperature up to $350^{\circ}C$ for 1 h. The morphologies of silver nanowires arrayed in the AAO membrane were investigated using SEM. The chemical composition and crystalline structure were confirmed by XRD and EDX. The electroless-deposited silver nanowires in AAO revealed a well-crystallized self-ordered array with a width of 10 nm.

단일 스위치와 전압 체배 회로를 이용하는 고변압비와 낮은 전압 스트레스를 가진 새로운 비절연형 DC-DC 컨버터 토폴로지 (Novel Non-Isolated DC-DC Converter Topology with High Step-Up Voltage Gain and Low Voltage Stress Characteristics Using Single Switch and Voltage Multipliers)

  • Tran, Manh Tuan;Amin, Saghir;Choi, Woojin
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2019년도 전력전자학술대회
    • /
    • pp.83-85
    • /
    • 2019
  • The use of high voltage gain converters is essential for the distributed power generation systems with renewable energy sources such as the fuel cells and solar cells due to their low voltage characteristics. In this paper, a high voltage gain topology combining cascode Inverting Buck-Boost converter and voltage multiplier structure is introduced. In proposed converter, the input voltage is connected in series at the output, the portion of input power is directly delivered to the load which results in continuous input current. In addition, the voltage multiplier stage stacked in proper manner is not only enhance high step-up voltage gain ratio but also significantly reduce the voltage stress across all semiconductor devices and capacitors. As a result, the high current-low voltage switches can be employed for higher efficiency and lower cost. In order to show the feasibility of the proposed topology, the operation principle is presented and the steady-state characteristic is analyzed in detail. A 380W-40/380V prototype converter was built to validate the effectiveness of proposed converter.

  • PDF

내식성 및 표면경도 향상을 위한 AISI 304L 스테인리스강의 저온 플라즈마질화 프로세스 (Low Temperature Plasma Nitriding Process of AISI 304L Austenitic Stainless Steels for Improving Surface Hardness and Corrosion Resistance)

  • 이인섭
    • 대한금속재료학회지
    • /
    • 제47권10호
    • /
    • pp.629-634
    • /
    • 2009
  • The effects of processing parameters on the surface properties of the hardened layers processed by the low temperature plasma nitrocarburizing and the low temperature two-step plama treatment (carburizing+nitriding) were investigated. The nitrogen-enriched expanded austenite structure (${\gamma}_N$) or S phase was formed on all of the treated surface. The surface hardness reached up to 1200 $HV_{0.025}$, which is about 5 times higher than that of untreated sample (250 $HV_{0.1}$). The thickness of hardened layer of the low temperature plasma nitrocarburized layer treated at $400^{\circ}C$ for 40 hour was only $15{\mu}m$, while the layer thicknesss in the two-step plama treatment for the 30 hour treatment increased up to about $30{\mu}m$. The surface thickness and hardness increased with increasing treatment temperature and time. In addition, the corrosion resistance was enhanced than untreated samples due to a high concentration of N on the surface. However, higher treatment temperature and longer treatment time resulted in the formation of $Cr_2N$ precipitates, which causes the degradation of corrosion resistance.

규칙파중 항공기 이.착륙시 초대형 부유식 해양구조물의 천이 응답 해석 (Transient Responses of an Airplane Taking off from and Landing on a Very Large Floating Structure in Regular Waves)

  • 신현경;이호영;임춘규;강점문;윤명철
    • 한국해양공학회지
    • /
    • 제15권1호
    • /
    • pp.26-30
    • /
    • 2001
  • Up to now, Most studies of hydroelasticity are about frequency domain analysis. Those aren't suited for analysis of the landing take-off, and dropping of aircraft on a structure. So, the concern of this paper is the transient behavior of a VLFS subjected to dynamic load, induced by airplane landing and take-off. To predict the added mass, damping coefficient, and wave exciting force, the source-dipole distribution method was used in the frequency domain. The responses are accomplished by using the FEM scheme. A time domain analysis method is based on the Newmark β method to pursue the time step procedure, taking advantage of memory effect function for hydrodynamic effects.

  • PDF

친환경농업 특화지역 농업인의 농업.농촌에 대한 의식조사 (Survey Results of the Organic Farmers' Attitude on Agriculture and Rural Area)

  • 허승욱
    • 한국유기농업학회지
    • /
    • 제15권3호
    • /
    • pp.257-275
    • /
    • 2007
  • The objectives of this study were to analysis the farmer's attitude on agriculture and rural area where is developed Environmentally Friendly Agriculture (EFA). To analysis satisfaction level and prospect about EFA, famer's survey were conducted. The sample size of the survey was 176 respectively. Of the famers surveyed, 85.9% thought their income is higher than general farmer in the same area. However, when asked how the future income change, 40.7% responded that will be decreasing step by step. 89.2% of the farmer respondent thought that they want dwelling in rural area and continuing agriculture in the future. However, 29.9% of the farmer respondent thought that rural area is not proper to their children as the future residence. In order to training of new lamer, it is very important to set up stable income structure, improving of welfare facilities, medical facilities and education infra and so on. In addition, it need to develop and spread of environmentally friendly agri-technology, price preservation of environmentally friendly agri-product and supply extension of environmentally friendly agri-material etc.

  • PDF

효과적인 RCM분석을 위한 조직체계에 관한 연구 (The research for organizational system with effective RCM analysis)

  • 김민호;송기태;백영구;이기서
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.2125-2129
    • /
    • 2008
  • In present, RCM has been hot issue in the domestic railway industry areas. Based on this circumstance, in this paper, for the purpose of an effective RCM system construction, a suitable organization structures which are to be applied to the railway system is proposed. Some examples and descriptions about the responsibilities and the roles which should be done by each RCM team, during the RCM analysis, as step by step for RCM analysis are also described. By using the formalized organization, the tasks for maintenance are allocated to each staff and the data for RCM analysis could be managed, systematically, as well. To sum up, it would be expected that based on the systematic organization structure for RCM analysis, the results of RCM analysis, that mean the maintenance methods and intervals for preventive maintenance, on specific railway system could be more reliable and accurate.

  • PDF

Dam-reservoir-foundation interaction effects on the modal characteristic of concrete gravity dams

  • Shariatmadar, H.;Mirhaj, A.
    • Structural Engineering and Mechanics
    • /
    • 제38권1호
    • /
    • pp.65-79
    • /
    • 2011
  • Concrete hydraulic structures such as: Dams, Intake Towers, Piers and dock are usually recognized as" Vital and Special Structures" that must have sufficient safety margin at critical conditions like when earthquake occurred as same as normal servicing time. Hence, to evaluate hydrodynamic pressures generated due to seismic forces and Fluid-Structure Interaction (FSI); introduction to fluid-structure domains and interaction between them are inevitable. For this purpose, first step is exact modeling of water-structure and their interaction conditions. In this paper, the basic equation involved the water-structure-foundation interaction and the effective factors are explained briefly for concrete hydraulic structure types. The finite element modeling of two concrete gravity dams with 5 m, 150 m height, reservoir water and foundation bed rock is idealized and then the effects of fluid domain and bed rock have been investigated on modal characteristic of dams. The analytical results obtained from numerical studies and modal analysis show that the accurate modeling of dam-reservoir-foundation and their interaction considerably affects the modal periods, mode shapes and modal hydrodynamic pressure distribution. The results show that the foundation bed rock modeling increases modal periods about 80%, where reservoir modeling changes modal shapes and increases the period of all modes up to 30%. Reservoir-dam-foundation interaction increases modal period from 30% to 100% for different cases.