• Title/Summary/Keyword: Step-Down Method

검색결과 184건 처리시간 0.029초

Measurement of Indoor Air Quality for Ventilation with the Existence of Occupants in Schools

  • Shin Hee-Soo;Lee Jai-Kwon;Ahn Young-Chull;Yeo Chang-Shin;Byun Sang-Hyun;Lee Jae-Keun;Kang Tae-Wook;Lee Kam-Gyu;Park Hyo-Soon
    • Journal of Mechanical Science and Technology
    • /
    • 제19권4호
    • /
    • pp.1001-1005
    • /
    • 2005
  • This paper evaluates the performance of ventilation for the removal of indoor pollutants as a function of ventilation rate and the number of occupants in a test room and school classroom. An experimental apparatus consists of a test room, a tracer gas supply system, a gas detector, and a fan for ventilation air supply with a controller. The ventilation performance is evaluated in a step-down method based on ASTM Standard E741-83 using $CO_{2}$ gas as a tracer gas in the test room of 35 $m^{3}.$ For the ventilation air flow rate of 1.0 ACH, a recommended ventilation flow rate of Korea school standard for acceptable indoor air quality in the case of one person, CO_{2}$ gas concentration decreases up to $55{\%}$ within 50 minutes without occupancy and increases up to $75{\%}$ in the case of one occupant. Also indoor air quality at the school classroom is investigated experimentally.

남제주군 보건진료소 이용 주민의 상병양상변화 고찰(1997년~2003년) (A Study on Changes in Trends of Disease of Residents Who Received Treatment at Nam Jeju County Primary Health Care Post(1997~2003))

  • 강나연
    • 한국농촌간호학회지
    • /
    • 제2권2호
    • /
    • pp.133-144
    • /
    • 2007
  • Purpose: The purpose of this study was to examine the trends of disease of residents who had treatment in primary health care posts in N-county over the past seven years (1997-2003). The data will assist in planning responses to changes in the health care environment and in planning health promotion programs. Method: A retrospective descriptive survey was conducted of the computerized records of primary health care done by community health practitioners over the last seven years. Cross analysis was conducted among the data using SAS, and the results were displayed in frequencies and percentages. The data were collected from May to September 2004. Results: The results of the study are as follows: 1. The six most frequent diseases were ranked as follows: diseases of the 1) respiratory system, 2) musculoskeletal system and connective tissue, 3) digestive system, 4) skin and subcutaneous tissue, 5) circulatory system, and 6) symptoms, signs and abnormal clinical and laboratory findings. Especially in 2002, circulatory system related disease rose two steps in the ranking and digestive system related disease went a step down. 2. The patients' use of primary health care posts over the past seven years continued to increase on the whole. Conclusions: According to these results, each primary health care post should carry out special health promotion programs that fit the local society of N- county and are in accordance with changes in health care needs.

유방절제술 환자를 위한 운동프로그램 개발 (Development of an Exercise Program for Postmastectomy Patient)

  • 이자형;조재경;오진아;김성희;안혜임
    • 여성건강간호학회지
    • /
    • 제10권4호
    • /
    • pp.301-310
    • /
    • 2004
  • Purpose: The purpose of this study was to develop an exercise program for postmastectomy patients. Method: This study was conducted from October, 2003 to June, 2004. The exercise program was developed based on literature review and needs assessment using focus group interviews. The subjects for the focus group interview consisted of 11 patients, 13 recovering patients, and 20 nurses from 3 hospitals. Development of the program was proceeded with analysusm design and development steps. Result: The results of the needs assessment using the focus group interview showed that the exercise program was imperative for postmastectomy patients. Based on the results, a home video tape containing 3 steps, was developed. Each step includes warming-up, stretching, the main exercise, and cool-down. Steps 2 and 3 include exercises with an elastic band, and an elastic ball. The program was modified after conducting a pre-test. A self-checklist including shoulder mobility, hand strength, arm volume and subjective comments on how they feel will be used before and after the exercise program. Conclusion: The exercise program will improve breast cancer patients' quality of life and their physical well-being. Further studies are recommended to test the effectiveness of the exercise program.

  • PDF

MBE growth of topological insulator $Bi_2Se_3$ films on Si(111) substrate

  • Kim, Yong-Seung;Bansa, Namrata;Edrey, Eliav;Brahlek, Mathew;Horibe, Yoichi;Iida, Keiko;Tanimura, Makoto;Li, Guo-Hong;Feng, Tian;Lee, Hang-Dong;Gustafsson, Torgny;Andrei, Eva;Cheong, Sang-Wook;Oh, Seong-Shik
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.59-59
    • /
    • 2011
  • We will report atomically sharp epitaxial growth of $Bi_2Se_3$ three-dimensional topological insulator films on Si(111) substrate with molecular beam epitaxy (MBE). It was achieved by employing two step growth temperatures to prevent any formation of second phase, like as $SiSe_2$ clusters, between $Bi_2Se_3$ and Si substrate at the early stage of growth. The growth rate was determined completely by Bi flux and the Bi:Se flux ratio was kept ~1:15. The second-phase-free atomically sharp interface was verified by RHEED, TEM and XRD. Based on the RHEED analysis, the lattice constant of $Bi_2Se_3$ relaxed to its bulk value during the first quintuple layer implying the absence of strain from the substrate. Single-crystalline XRD peaks of $Bi_2Se_3$ were observed in films as thin as 4 QL. TEM shows full epitaxial structure of $Bi_2Se_3$ film down to the first quintuple layer without any second phases. This growth method was used to grow high quality epitaxial $Bi_2Se_3$ films from 3 QL to 3600 QL. The magneto-transport properties of these thin films show a robust 2D surface state which is thickness independent.

  • PDF

실내 유해가스 제거효율 향상을 위한 환기성능에 관한 실험적 연구 (An Experimental Study on the Ventilation Performance to Enhance Removal Efficiency of Indoor Hamful Gases)

  • 구재현
    • 한국화재소방학회논문지
    • /
    • 제23권5호
    • /
    • pp.117-124
    • /
    • 2009
  • 본 연구의 목적은 실내 유해가스의 제거효율 향상을 위하여 기계 환기시스템의 환기성능을 분석하는 것이다. 환기성능은 ASTM E741-83 기준에 의거하여 체강법을 사용하여 평가하였다. 추적가스($CO_2$) 기법을 사용하여 환기율과 급기/배기구 위치에 따른 환기성능이 평가되었다. 결과적으로 $CO_2$ 농도는 환기율 증가에 따라 지수적으로 감소하며 환기농도가 증가함을 파악하였다. 2종 환기방식 시스템의 환기성능이 1종 환기방식 또는 3종 환기방식 보다 더 우수하였다. 환경공조챔버에서 자연감쇠의 경우와 비교하여 급기량 570Lpm에서 1시간 후에 재실자가 없는 경우의 환기성능은 55%까지 증가하였고 1인 재실자가 있는 경우의 환기성능은 25%까지 증가하였다. 사무실에서 급기량 570Lpm인 경우 환기성능은 자연감쇠와 비교하여 15% 이상 크게 나타났다.

자동차용 DC-DC 컨버터의 전자파 방사 감소 방법에 대한 시뮬레이션 연구 (A Simulation Investigation on the Spurious Emission Reduction of the Automotive DC-DC Converter)

  • 채규수
    • 융합정보논문지
    • /
    • 제10권8호
    • /
    • pp.47-52
    • /
    • 2020
  • 본 연구에서는 자동차용 강압 DC-DC 컨버터 모듈 설계 방법 중 변조 스위칭 잡음과 전자파 방사의 감소방법에 대한 시뮬레이션 연구가 수행되었다. PMIC(Power Management Integrated Circuit) 칩을 이용한 4층 PCB 기본 회로가 제시되었고, 컨버터 모듈의 두 입력단자(+, -) 및 입력 필터와 PMIC 사이에서의 전자파 잡음과 전자기 방사 특성에 대한 시뮬레이션이 1.0~5.0MHz 대역과 100MHz 대역에서 수행되었다. 전도성 방사 특성은 3.0MHz와 104MHz에 대한 결과를 제시하였고, 입력포트로 되돌아오는 전도성 방사를 줄이기 위해 컨버터 출력 단자를 PCB의 3층 혹은 4층에 입력단의 전류 흐름과 반대되는 방향으로 배치하여 평균 10dB 이상의 개선효과가 나타났다. 본 연구 결과는 지금까지 제시된 불요 전자파 감소 방법에 비해 개선효과가 높아 향후 컨버터 모듈 설계에 유용하게 활용될 것으로 기대된다.

이중 대립 쟁기피판을 이용한 유두 재건술: 증례보고 (Nipple Reconstruction with the Double Opposing Plow Flap: A Case Report)

  • 허찬영;은석찬;백롱민;민경원
    • Archives of Plastic Surgery
    • /
    • 제34권4호
    • /
    • pp.490-492
    • /
    • 2007
  • Purpose: Nipple reconstruction is an important step in breast reconstruction after mastectomy. There are considerable number of reconstructive methods developed over the past years. Each of these has not only its own special advantages, but also limitations. Therefore, no single method has become the overwhelming favorite. Sometimes it seems to be compromised when the nipple must be located directly over a linear scar. Methods: A 48-year-old female patient received a central lumpectomy with circumareolar resection of the nipple areolar complex 4 months ago. The newly designed nipple must be positioned directly astride a scar. We drew two equal-sized rectangular flaps sharing a common limb on a transverse scar and the result was two opposing plow form. Each flap size was about 1.3 cm wide and 2.5 cm long. First we elevated the flap from the distal part at a deep dermal plane, then deepened the level of dissection to raise the dermal-fat flaps. The donor site could be closed directly without any dog-ear deformity. Then we folded down the elevated flaps and loosely sutured skin with nonabsorbable materials. Each flap inner side was approximated side by side. Finally we made new natural nipple with 6 mm projection. We applied tattooing in the areola area with micropigmentation device after three months. Results: After ten months of follow-up periods, the nipple projection was stable and symmetric. The nipple projection was 3.1 mm, compared with 2.8 mm for the opposite nipple. Conclusion: Our experiences shows that this double opposing plow flap is a particularly useful and simple technique when there is a traverse scar crossing the center of the proposed nipple area.

뇌졸중 환자의 마비쪽에 따른 골반의 기울임과 보행의 상관관계 분석 (Correlation Analysis of Pelvic Tilt and Gait according to the Paralytic Side of Stroke Patients)

  • Yong Seon, Lee;Jong-Hyuk, Yun
    • 한국운동역학회지
    • /
    • 제32권4호
    • /
    • pp.111-120
    • /
    • 2022
  • Objective: This study investigated the effect of pelvic tiltng according to the paralytic side on gait in stroke patients during a 10 m functional movement timed up and go (TUG) test. Method: In this study, gait parameters were measured using a gait analyzer for 20 stroke patients and their gait was analyzed during a 10 m TUG test. For statistical analysis, an independent sample t-test were performed for age, height, and weight among general characteristics of subjects and homogeneity was tested by performing a chi-square test for gender, paralysis side, period of onset, and K-MMSE score. In order to understand the relationship between each variable, Pearson correlation analysis was performed on the variables. Results: First, the right-hand paralyzed group showed correlations in cadence and gait velocity in the up and down tilt of the pelvis, and the left-hand paralyzed group showed correlations in cadence and step length in the anterior and posterior tilt of the pelvis. Second, the tilt of the pelvis was correlated with the Sit to stand, walk forward, walk backwards, turn around at the end point, sit on a chair and the total TUG time in the right hemiplegic group compared to the left hemiplegic group. Conclusion: In this study, a significant correlation was confirmed as a result of gait analysis of right-handed stroke patients divided into a right paraplegic group and a left paraplegic group. In the future, it is suggested that treatment for improving gait of stroke patients should be treated differently for the right and left paralyzed side.

P-형 실리콘에서 마이크로 와이어 형성에 미치는 마스크 패턴의 영향 (The Effect of Mask Patterns on Microwire Formation in p-type Silicon)

  • 김재현;김강필;류홍근;우성호;서홍석;이정호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 추계학술대회 논문집 Vol.21
    • /
    • pp.418-418
    • /
    • 2008
  • The electrochemical etching of silicon in HF-based solutions is known to form various types of porous structures. Porous structures are generally classified into three categories according to pore sizes: micropore (below 2 nm in size), mesopore (2 ~ 50 nm), and macropore (above 50 nm). Recently, the formation of macropores has attracted increasing interest because of their promising characteristics for an wide scope of applications such as microelectromechanical systems (MEMS), chemical sensors, biotechnology, photonic crystals, and photovoltaic application. One of the promising applications of macropores is in the field of MEMS. Anisotropic etching is essential step for fabrication of MEMS. Conventional wet etching has advantages such as low processing cost and high throughput, but it is unsuitable to fabricate high-aspect-ratio structures with vertical sidewalls due to its inherent etching characteristics along certain crystal orientations. Reactive ion dry etching is another technique of anisotropic etching. This has excellent ability to fabricate high-aspect-ratio structures with vertical sidewalls and high accuracy. However, its high processing cost is one of the bottlenecks for widely successful commercialization of MEMS. In contrast, by using electrochemical etching method together with pre-patterning by lithographic step, regular macropore arrays with very high-aspect-ratio up to 250 can be obtained. The formed macropores have very smooth surface and side, unlike deep reactive ion etching where surfaces are damaged and wavy. Especially, to make vertical microwire or nanowire arrays (aspect ratio = over 1:100) on silicon wafer with top-down photolithography, it is very difficult to fabricate them with conventional dry etching. The electrochemical etching is the most proper candidate to do it. The pillar structures are demonstrated for n-type silicon and the formation mechanism is well explained, while such a experimental results are few for p-type silicon. In this report, In order to understand the roles played by the kinds of etching solution and mask patterns in the formation of microwire arrays, we have undertaken a systematic study of the solvent effects in mixtures of HF, dimethyl sulfoxide (DMSO), iso-propanol, and mixtures of HF with water on the structure formation on monocrystalline p-type silicon with a resistivity with 10 ~ 20 $\Omega{\cdot}cm$. The different morphological results are presented according to mask patterns and etching solutions.

  • PDF

FPGA를 이용한 시퀀스 제어용 32비트 마이크로프로세서 설계 (The Design of 32 Bit Microprocessor for Sequence Control Using FPGA)

  • 양오
    • 대한전자공학회논문지SD
    • /
    • 제40권6호
    • /
    • pp.431-441
    • /
    • 2003
  • 본 논문은 FPGA를 이용하여 시퀀스 제어용 32비트 마이크로프로세서를 설계하였다. 이를 위해 VHDL을 이용하여 톱-다운 방식으로 마이크로프로세서를 설계하였으며, 고속처리의 문제점을 해결하기 위해 프로그램 메모리부와 데이터 메모리부를 분리하여 설계함으로써 인스트럭션을 페치 하는 도중에 시퀀스 명령을 실행할 수 있는 Harvard 구조로 설계하였다. 또한 마이크로프로세서의 명령어들을 시퀀스제어에 적합하도록 RISC형태의 32 비트 명령어로 고정하여 명령어의 디코딩 시간과 데이터 메모리의 인터페이스 시간을 줄였다. 특히 설계된 마이크로프로세서의 실시간 디버깅 기능을 구현하기 위해 싱글 스텝 런, 일정 프로그램 카운터 브레이크, 데이터 메모리와 일치시 정지 기능 등을 구현함으로써 구현된 프로세서의 디버깅을 쉽게 하였다. 또한, 시퀀스제어에 적합한 펄스명령, 스텝 콘트롤 명령, 마스터 콘트롤 명령 등과 같은 비트 조작 명령과, BIN형과 BCD형 산술명령, 배럴 쉬프트명령 등을 구현하였다. 이와 같은 기능들을 FPGA로 구현하기 위하여 자이링스(Xilinx)사의 V600EHQ240(60만 게이트)과 Foundation 4.2i를 사용하여 로직을 합성하였다. Foundation 합성툴 환경에서 시뮬레이션과 실험에서 성공적으로 수행되었다. 본 논문에서 구현된 시퀀스 제어용 마이크로프로세서의 우수성을 보이기 위해 시퀀스제어용 명령어를 많이 가지고 있는 Hitachi사의 마이크로프로세서인 H8S/2148과 성능을 비교하여 본 논문에서 설계된 시퀀스 제어용 프로세서가 우수함을 확인하였다.