• Title/Summary/Keyword: Step pulse

Search Result 365, Processing Time 0.025 seconds

Chemical Properties of Cu( II ) Compound Containing Endocrine Disrupter, Bis-Phenol A

  • Park, Chil-Nam
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.10 no.S_3
    • /
    • pp.121-126
    • /
    • 2001
  • The techniques of pulse and cyclic voltammetry were applied to the determination of (E$_{1}$2)$_2$-(E$_{1}$2)$_1$ for two-step electrochemical charge transfers. In addition, a simple amplitude was derived far the dependence of the differential pulse response on (E$_{l}$ 2/)$_1$ and (E$_{1}$2/)$_2$. and the use of peak to peak separation in cyclic voltammetry and differential pulse methods was evaluated. A comparison of the comproportionation constants(Ke) from differential pulse and cyclic voltammetry methods exhibited a good agreement within 5%.

  • PDF

On the Dynamic Response of Laminated Circular Cylindrical Shells under Dynamic Loads (동하중을 받는 복합재료 원통셸의 동적거동 해석)

  • 이영신;이기두
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.11
    • /
    • pp.2684-2693
    • /
    • 1993
  • The free vibration and dynamic response of cross-ply for CFRP and GFRP laminated circular cylindrical shells under dynamic loadings are investigated by using the first-order shear deformation shell theory. The modal analysis technique is used to develop the analytical solutions of simply supported cylindrical shells under dynamic load. The analysis is based on an expansion of the loads, displacements and rotations in a double Fourier series which satisfies the and boundary conditions of simply support. Analytical solution is assumed to be separable into a function of time and a function of position. In this paper, the considered load forces are step pulse, sine pulse, triangular(1, 2, 3) pulse and exponential pulse. The solution for a given loading pulse can be found by involving the convolution integral. The results show that the dynamic response are governed primarily by the natural period of the structure.

Development of the pulse analyzing system using FBG (FBG를 이용한 맥진 시스템 개발)

  • Jeon, Young-Ju;Lee, Jeon;Ryu, Hyun-Hee;Lee, Jae-Hoon;Lee, Si-Woo;Kim, Jong-Yeol
    • Korean Journal of Oriental Medicine
    • /
    • v.13 no.3
    • /
    • pp.105-110
    • /
    • 2007
  • This work reports the pulse diagnosis system using FBG sensors which can display pulse signals detected while oriental medical doctors are conducting pulse diagnoses and simultaneously pressing the sensors by three fingers. Each optical fiber has five FBG sensing units fabricated in 2 mm width and 2 mm inter-sensor spacing. Three optical fibers with the FBG units in the parallel line configuration are then placed on each finger-pressing region and thus overall 9 fibers are used for the pulse measurements on the so-called "chon", "gwan", and "ch대k". A fixture holding the optical fiber arrays is able to adjust the height of the FBG sensing units while placing the fibers on the wrist. The pulse signals detected by the FBG sensors from chon, kwan, and chuk have been analyzed using 4 channel spectrum analyzer connected to the optical fibers. The measured pulse signals exhibit variations due to the nonuniform pressure distributions applied. resulting in the differences in the detected pulse signals between fiber lines. However. this work is the first step towards objective and quantitative analyses of the pulse diagnosis in oriental medicine which has traditionally been performed on subjective basis. Future works will be devoted to improving sensor stability, developing the way applying pressure and algorithms reporting the objective classification of the pulse status from systemic measurements using the sensors instead of relying on the clinicians' diagnoses subjectively performed. A successful pulse diagnosis system emerging in the future is expected to contribute to education as well as promoting pulse diagnosis in oriental medicine to the scientific research area.

  • PDF

Sa-Am Acupuncture with Spleen Seung-gyuck induces an acute increase of radial pulse parameters related to arterial stiffness in healthy subjects: A comparative study of Jung-gyuck and Seung-gyuck

  • Yim, Yun-Kyoung
    • The Journal of Korean Medicine
    • /
    • v.35 no.2
    • /
    • pp.19-27
    • /
    • 2014
  • Objectives: To investigate the different effects of Sa-Am acupuncture with Spleen Jung-gyuck and Spleen Seung-gyuck on the radial pulse in healthy subjects. Methods: Sixty healthy volunteers (30 males and 30 females) participated in this study. The participants were randomly divided into three groups: control (C), Sa-Am acupuncture with Spleen Jung-gyuck (SP+) and Sa-Am acupuncture with Spleen Seung-gyuck (SP-). The radial pulse was measured using a multi-step tonometry system before, and 0, 30 and 60 minutes after acupuncture. Results: The heart rate adjusted radial augmentation index (RAI/HR) and high-tensioned pulse area (W area) significantly increased in the SP- group compared to the C and SP+ groups in males. The systolic pulse period (T4) increased significantly in the SP- group compared to the C and SP+ groups in females. The RAI/HR had positive correlations with W area and T4. Conclusion: The effects of Sa-Am acupuncture with Spleen Jung-gyuck and Spleen Seung-gyuck are different. Sa-Am acupuncture with Spleen Seung-gyuck induces acute increases of radial pulse parameters related to arterial stiffness in healthy subjects.

Development of 3 D.O.F parallel robot's simulator for education

  • Yoo, Jae-Myung;Kim, John-Hyeong;Park, Dong-Jin
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2290-2295
    • /
    • 2005
  • In this paper, it is developed simulator system of 3 D.O.F parallel robot for educate of expertness. This simulator system is composed of three parts ? 3 D.O.F parallel robot, controller (hardware) and software. First, basic structure of the robot is 3 active rotary actuator that small geared step motor with fixed base. An input-link is connected to this actuator, and this input-link can connect two ball joints. Thus, two couplers can be connected to the input-link as a pair. An end-plate, which is jointed by a ball joint, can be connected to the opposite side of the coupler. A sub-link is produced and installed to the internal spring, and then this sub-link is connected to the upper and bottom side of the coupler in order to prevent a certain bending or deformation of the two couplers. The robot has the maximum diameter of 230 mm, 10 kg of weight (include the table), and maximum height of 300 mm. Hardware for control of the robot is composed of computer, micro controller, pulse generator, and motor driver. The PC used in the controller sends commands to the controller, and transform signals input by the user to the coordinate value of the robot by substituting it into equations of kinematics and inverse kinematics. A controller transfer the coordinate value calculated in the PC to a pulse generator by transforming it into signals. A pulse generator analyzes commands, which include the information received from the micro controller. A motor driver transfer the pulse received from the pulse generator to a step motor, and protects against the over-load of the motor Finally, software is a learning purposed control program, which presents the principle of a robot operation and actual implementation. The benefit of this program is that easy for a novice to use. Developed robot simulator system can be practically applied to understand the principle of parallel mechanism, motors, sensor, and various other parts.

  • PDF

Design of Impulse generator Using Gain-Switched Semiconductor Laser for UWB (반도체 레이저의 이득스위칭을 이용한 UWB 임펄스 발생기 설계)

  • Kwon Soon-young;Kim Bum-in;Park Chong-dae
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.6 s.336
    • /
    • pp.61-66
    • /
    • 2005
  • In this paper, we implemented a impulse generator, the one of the part in UWB(Ultra Wide Band) system using step recovery diode(SRD) and gain-switced semiconductor laser. The impulse generator was consisted of four stages; The first stage used SRD to generate the first impulse for gain switching. The second stage controled current for the suitable gain switching condition. The third was the second impulse generator to generate gaussian pulse. For gain switching, the first impulse was applied to semiconductor laser. In the last stage the gain switched impulse was converted into mono-gaussian pulse. The measured mono-gaussian pulse was 360 psec pulse-width and $-70mV \~ +50mV$ amplitude in time domain. In frequency domain its magnitude and bandwidth was, respectively, -41dBm and 3.6GHz. Accordingly, the impulse generator that we suggested was suitable for UWB systems.

The high repetition operating characteristics of pulsed Nd:YAG laser by parallel mesh and alternating charge-discharge system (병렬 메쉬 및 교번 충.방전 방식에 의한 펄스형 Nd:YAG 레이저의 고반복 동작특성에 관한 연구)

  • Park, K.R.;Kim, B.G.;Hong, J.H.;Kim, W.Y.;Kim, H.J.;Cho, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1060-1062
    • /
    • 1999
  • Pulsed Nd:YAG laser is used widely for materials processing and instrumentation. It is very important to control the laser energy density in materials processing by a pulsed Nd:YAG laser. A pulse repetition rate and a pulse width are regarded as the most dominant factors to control the energy density of laser beam. In this study, the alternating charge-discharge system was designed to adjust a pulse repetition rate. And the parallel mesh is added to increase laser output power. This system is controlled by one chip microprocessor and allows to replace an expensive condenser for high frequency to a cheap condenser for low frequency. In addition, we have investigated the current pulse shape of flashlamp and the operating characteristics of a pulsed Nd:YAG laser. As a result, it is found that the laser output of the power supply using the parallel mesh and the alternating charge-discharge system is not less than that of typical power supply. As the pulse repetition rate rises from 10pps to 110pps by the step of 20pps at 1000V and 1200V, it is found that the laser efficiency decreases but the laser output power increases about 5W at each step.

  • PDF

The high repetition operating characteristics of pulsed Nd:YAG laser by alternating charge-discharge system (펄스형 Nd:YAG 레이저의 교번 충.방전 방식에 의한 고반복 동작특성)

  • Kim, W.Y.;Park, K.R.;Kim, B.G.;Hong, J.H.;Kang, U.;Kim, H.J.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2204-2206
    • /
    • 1999
  • Pulsed Nd:YAC laser is used widely for materials processing and instrumentation. It is very important to control the laser energy density in materials processing by a pulsed Nd:YAG laser. A pulse repetition rate and a pulse width are regarded as the most dominant factors to control the energy density of laser beam. In this study, the alternating charge-discharge system was designed to adjust a pulse repetition rate. This system is controlled by one chip microprocessor and allows to replace an expensive condenser for high frequency to a cheap condenser for low frequency. In addition. we have investigated the current pulse shape of flashlamp and the operating characteristics of a pulsed Nd:YAG laser. As a result, it is found that the laser output of the power supply using the alternating charge-discharge system is not less than that of typical power supply. As the pulse repetition rate rises from 30pps to 120pps by the step of 30pps at 1200V, it is found that the laser efficiency decreases but the laser output power increases about 6W at each step.

  • PDF

Precise open-loop positioning using LPM with error correction

  • Furuhashi, Hideo;Shingu, Hiroyasu;Hayashi, Niichi;Watanabe, Shigeo;Sumi, Tetsuo;Uchida, Yoshiyuki
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1995.10a
    • /
    • pp.211-214
    • /
    • 1995
  • A precise open-loop positioning system using linear pulse motor has been developed. The system is operated in a microstepping mode by controlling the electric current. One step of 508 .mu.m (tooth pitch of the linear pulse motor) is divided into 508 micro-steps equally. The displacement is measured with a system using a Fiezeau-type interferometer. Periodical positioning error with a period of the tooth pitch was observed in this system. Therefore, the position is corrected using the error. The error is stored into computer in advance, and the microstep current is corrected on basis of the stored data. Although the positioning error of the system without the correction was .+-.4.5 .mu.m, that with the correction was decreased to .+-.1.0 .mu.m.

  • PDF

Optimized Gate Driving to Compensate Feed-through Voltage for $C_{ST}-on-Common$

  • Jung, Soon-Shin;Yun, Young-Jun;Park, Jae-Woo;Roh, Won-Yeol;Choi, Jong-Sun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2000.01a
    • /
    • pp.73-74
    • /
    • 2000
  • In recent years, attempts have been made to greatly improve the display quality of active-matrix liquid crystal display devices, and many techniques have been proposed to solve such problems as gate signal delay, feed-through voltage and image sticking[1-3]. To improve these problems which are caused by the feed-through voltage, we have evaluated new driving methods to reduce the feed-through voltage. Two level gate-pulse was used for the gate driving of the cst-on-common structure pixels. These gate driving methods offer better feed-through characteristics than conventional simple gate pulse. Optimized step signal will compensate by step pulse time and voltage. The evaluation of the suggested driving methods were performed by using a TFT-LCD array simulator PDAST which can simulate the gate, data and pixel voltages of a certain pixel at any time and at any location on a TFT array. The effect of the new driving method was effectively analyzed.

  • PDF