• 제목/요약/키워드: Step pulse

검색결과 365건 처리시간 0.031초

어군탐지기용 저주파.고출력 음향 변환기의 설계 (Design of a low frequency, high power acoustic transducer to use in the echo sounder)

  • 이대재
    • 수산해양기술연구
    • /
    • 제36권1호
    • /
    • pp.1-11
    • /
    • 2000
  • A low frequency, high power hydroacoustic transducer with 7 tonpilz piston elements assembled in a circular array suitable for marine application, such as the transmission of underwater information and the development of new fisheries resources in the deep sea zone was designed. A modified Mason's model was applied to monitor and to simulate the transducer behavior at each step during the fabrication. The in air, and in water constructed tonpilz transducer was tested experimentally and numerically by changing the size and the type of the material for head, tail and acoustic window. Also, the developed transducer was excited by pulse signals and the received waveform was analyzed. The resonance peaks in the transmitting voltage response(TVR) of a single tonpilz element without housing were observed at 11.33kHz in air and 10.93kHz in air and 10.93 kHz in water, respectively, with the overall electrical-acoustic efficiency of 43.7%. The value of TVR of single tonpilz element with aluminum housing in water was 129.87dB re 1 $\mu$Pa/V at 12.25 kHz with the frequency bandwith of 2.15 kHz and half beam angle of 30.2$^{\circ}$at -3dB.The resonance peaks in the transmitting voltage response of the 7 element circular transducer were observed at 11.50 kHz in air and 11.45 kHz in water, respectively. The value of TVR in water 144.84 dB re 1$\mu$Pa/V at 11.5kHz with the frequency bandwith of 4.25 kHz and the half beam angle of $22.3^{\circ} $ at -3dB.Reasonable agreement between the experimental measurements and the theoretical predictions for the directivity patterns, TVRs and the impedance characteristics of the designed transducer was achieved.

  • PDF

단핵 및 이핵성 시프염기리간드 Cu(II) 착물의 특성과 Ascorbic Acid에 대한 산화반응 (Properties of Mononuclear and Binuclear Cu(II) Schiff Base Complexes and Oxidation of Ascorbic Acid)

  • 김선덕;이영석;박정은
    • 분석과학
    • /
    • 제13권5호
    • /
    • pp.558-564
    • /
    • 2000
  • 단핵성 네자리 시프염기인 N,N'-bissalicylidene-1,2-phenylenediamine(BSPD)와 이핵성 네자리 시프 염기 리간드인 N,N',N'',N'''-tetrasalicylidene-3,3',4,4'-tetraaminodiphenyl-methane (TSTM) 및 N, N',N'',N'''-tetrasalicylidene-3,3'-diaminobenzidine (TSDB)을 합성하고, 이들 리간드의 양성자 해리상수를 전위차법으로 구하였다. 합성된 시프염기 리간드들과 Cu(II) 이온을 이용해 착물을 합성하여 순환전압-전류법으로 착물의 특성을 측정한 결과 $Cu(II)_2$-TSTM 착물은 순환전압-전류법에서 두 과정 두 단계의 환원과정으로 두 전자의 확산 지배적인 과정으로 일어남을 알았다. 또한 단핵성 착물 Cu(II)-BSPD와 이핵성 착물 $Cu(II)_2$-TSDB 및 $Cu(II)_2$-TSTM을 ascorbic acid의 산화반응에 이용한 결과, 반응속도는 $Cu(II)_2$ -TSTM>$Cu(II)_2$-TSDB>Cu(II)-BSPD의 순으로 이핵성인 $Cu(II)_2$-TSTM 착물이 가장 큰 값을 가짐을 알았다.

  • PDF

Heat transfer monitoring between quenched high-temperature superconducting coated conductors and liquid nitrogen

  • Rubeli, Thomas;Colangelo, Daniele;Dutoit, Bertrand;Vojenciak, Michal
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제17권1호
    • /
    • pp.10-13
    • /
    • 2015
  • High-temperature superconducting coated conductors (HTS-CCs) are good candidates for resistive superconducting fault current limiter (RSFCL) applications. However, the high current density they can carry and their low thermal diffusivity expose them to the risk of thermal instability. In order to find the best compromise between stability and cost, it is important to study the heat transfer between HTS-CCs and the liquid nitrogen ($LN_2$) bath. This paper presents an experimental method to monitor in real-time the temperature of a quenched HTS-CC during a current pulse. The current and the associated voltage are measured, giving a precise knowledge of the amount of energy dissipated in the tape. These values are compared with an adiabatic numerical thermal model which takes into account heat capacity temperature dependence of the stabilizer and substrate. The result is a precise estimation of the heat transfer to the liquid nitrogen bath at each time step. Measurements were taken on a bare tape and have been repeated using increasing $Kapton^{(R)}$ insulation layers. The different heat exchange regimes can be clearly identified. This experimental method enables us to characterize the recooling process after a quench. Finally, suggestions are done to reduce the temperature increase of the tape, at a rated current and given limitation time, using different thermal insulation thicknesses.

Concentric Reducer와 Eccentric Reducer를 사용한 EMP 차폐 100dB급 급수관의 유동특성 평가 (Evaluation of Flow Characteristics in Water Supply Pipes Shielding Electromagnetic Pulse of 100 dB with Concentric and Eccentric Reducers)

  • 방승기;안혜린
    • 한국지열·수열에너지학회논문집
    • /
    • 제13권1호
    • /
    • pp.1-6
    • /
    • 2017
  • In this paper, the flow characteristics of water in the water supply pipes of a WBC array were evaluated. We simulated the flow velocities and pressures for a standard pipe, an expansion pipe with a concentric reducer, and an expansion pipe with an eccentric reducer using computational fluid dynamics. In the case of the standard pipe, when the inlet flow velocities were 0.5 m/s and 2.0 m/s, the maximum flow velocities at the center of the WBC array were 0.54 m/s and 2.74 m/s, respectively, which were the greatest values among those of all the pipe models considered. In the case of the expansion pipe, the maximum flow velocities at the center of the WBC array were almost the same under the same conditions regardless of the type of reducer. The pressure losses in the pipe due to the concentric and eccentric reducers were found to be (165.09 ${\times}$ inlet $velocity^{1.6677}$) and (210.98 ${\times}$ inlet $velocity^{1.6478}$), respectively. The coefficient of determination at this time was greater than 0.99 and was the same for both the models. As a simulation result, it was found that in order to reduce the pressure loss when pipe with WBC array is connected with a conventional pipe, diameter of the pipe with WBC array at that section should be enlarged by one step, and then connected to the conventional pipe with a concentric reducer.

Multi-Secondary Transformer: A Modeling Technique for Simulation - II

  • Patel, A.;Singh, N.P.;Gupta, L.N.;Raval, B.;Oza, K.;Thakar, A.;Parmar, D.;Dhola, H.;Dave, R.;Gupta, V.;Gajjar, S.;Patel, P.J.;Baruah, U.K.
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권1호
    • /
    • pp.78-82
    • /
    • 2014
  • Power Transformers with more than one secondary winding are not uncommon in industrial applications. But new classes of applications where very large number of independent secondaries are used are becoming popular in controlled converters for medium and high voltage applications. Cascade H-bridge medium voltage drives and Pulse Step Modulation (PSM) based high voltage power supplies are such applications. Regulated high voltage power supplies (Fig. 1) with 35-100 kV, 5-10 MW output range with very fast dynamics (${\mu}S$ order) uses such transformers. Such power supplies are widely used in fusion research. Here series connection of isolated voltage sources with conventional switching semiconductor devices is achieved by large number of separate transformers or by single unit of multi-secondary transformer. Naturally, a transformer having numbers of secondary windings (~40) on single core is the preferred solution due to space and cost considerations. For design and simulation analysis of such a power supply, the model of a multi-secondary transformer poses special problem to any circuit analysis software as many simulation softwares provide transformer models with limited number (3-6) of secondary windings. Multi-Secondary transformer models with 3 different schemes are available. A comparison of test results from a practical Multi-secondary transformer with a simulation model using magnetic component is found to describe the behavior closer to observed test results. Earlier models assumed magnetising inductance in a linear loss less core model although in actual it is saturable core made-up of CRGO steel laminations. This article discusses a more detailed representation of flux coupled magnetic model with saturable core properties to simulate actual transformers very close to its observed parameters in test and actual usage.

아세토니트릴 용매 중에서 Copper-1,5,9,13-Tetrathiacyclohexadecane착물의 전기화학적 거동과 그 분석적 응용 (Electrochemical Behaviors and Analytical Application of Copper-1,5,9,13-Tetrathiacyclohexadecane Complex in Acetonitrile)

  • 서무룡;이부영;최명자;배준웅;박태명
    • 대한화학회지
    • /
    • 제36권3호
    • /
    • pp.412-418
    • /
    • 1992
  • 비수용매인 아세토니트릴 중에서 Cu(Ⅱ)와 1,5,9,13-tetrathiacyclohexadecane[16-ane-$S_4$]의 착물에 대한 전기화학적 거동으로서 직류폴라로그램과 미분펄스폴라로그램으로부터 환원전류의 유형과 가역성을 조사하고, 이들 화합물의 분석적 응용으로서 수용액에 있는 Cu(Ⅱ) 이온을 염석추출법으로 정량하였다. 또한 아세토니트릴 용매 중에서 착물의 안정도 상수를 구하고, 분석적 응용으로 수용액 중의 Cu(Ⅱ)를 염석추출법으로 정량하기 위하여 추출조건, 곧 킬레이트와 염석제의 효과, pH 범위를 구하고 또한 Cu(Ⅱ) 이온을 정량하는데 있어서의 검량성과 공존이온 효과를 조사하였다. 실험결과로부터 환원 과정은 비가역적이었으며 환원전류는 확산지배적임을 알았다. 또한 아세토닐트릴 용매 중에서 착물의 log $K_f$의 값은 3.51이었으며 Cu(Ⅱ) 이온을 정량하는데 있어 공존하는 이온의 영향을 별로 받지 않아 선택성이 좋았으며 본 실험방법에 의한 정량한계는 60ppb 이었다.

  • PDF

Acetonitrile 용액중에서 살충제 O, O-Dimethyl-O-(3-Methyl-4-Nitrophenyl)-Phosphorothioate (Fenitrothion)의 전기화학적 환원 (On the Electrochemical Reduction of O, O-Dimethyl-O-(3-Methyl-4-Nitrophenyl)-Phosphorthioate (Fenitrothion) Pesticide in Acetonitrile Solution)

  • 김일광;김윤근;천현자
    • 대한화학회지
    • /
    • 제32권3호
    • /
    • pp.186-194
    • /
    • 1988
  • 계면활성 micelle을 형성하는 acetonitrile 용액을 O,O-dimethyl-O-(3-methyl-4-nitrophenyl)-phosphorothioate (Fenitrothion)의 전기화학적 환원을 direct current 및 differential pulase polarography, cyclic voltammetry 그리고 controlled potential coulometry 방법으로 연구하였다. Fenitrothion의 환원과정은 1단계로 4 전자 이동에 의한 부분 가역적 전자이동 화학반응(EC, EC)기구로 O,O-dimethyl-O-(3-methyl-4-hydroxyaminophenyl)-phosphorothioate를 형성하고, 더 높은 음전위에서 2 전자 이동에 따른 양성자 반응으로 phosphorus 원자와 phenoxy group의 단일 결합이 끊어지면서 주 생성물인 p-amino-m-cresol과 dimethyl thiophosphinic acid를 생성하였다. Sodium lauryl sulfate micelle 용액에서 polarography 환원파는 전체적으로 억제 되었으며 특히 1차 환원파는 음이온 micelle의 선택적 작용으로 2단계로 분리되었다.

  • PDF

22.9 kV-y 배전선로의 전압계측방법 개선에 관한 연구 (A Study on the Improvement of Voltage Measuring Method of 22.9 kV-y Distribution Lines)

  • 길경석;송재용
    • 센서학회지
    • /
    • 제7권4호
    • /
    • pp.293-299
    • /
    • 1998
  • 본 연구의 목적은 22.9 kV-y 특별고압 배전선로상에서 가스절연개폐기를 이용한 전압측정장치의 개발에 있다. 본 논문에서 제안한 전압측정장치는 일종의 광대역 용량성 분압기로, 가스개폐기의 절연붓싱에 설치한 검출전극, 임피던스 정합회로 및 전압버퍼로 구성되며, 기설의 가스절연개폐기에 구조 변경 없이 설치될 수 있다. 제작된 전압측정장치는 교정과 적용성 평가를 위하여 25.8 kV, 400 A 가스절연개폐기에 설치되었으며, 5 ns의 상승시간을 갖는 직각파 발생기로 주파수 응답특성을 조사하였다. 실험결과로부터 본 전압측정장치의 주파수 대역은 1.35 Hz에서 약 13 MHz이었으며, 60 Hz 상용주파수 전압에서 분압비 오차는 0.2% 이하였다. 또한 상용주파수 전압과 비진동성 충격전압에 대한 분압비와의 편차는 0.7% 이하로 나타났다.

  • PDF

세포증식을 위한 LED 조사 시스템 개발 (Development of LED Irradiation System for Cell Proliferation)

  • 천민우;박용필;이호식;김태곤;김영표
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2010년도 춘계학술대회
    • /
    • pp.581-582
    • /
    • 2010
  • 광 의료 분야 중 저출력레이저 치료에 사용되는 레이저와 같은 특정 파장을 발생하고 레이저보다 안정적으로 사용이 가능한 고휘도 LED를 조사하여 광 의료 분야에 적용할 수 있는 시스템을 개발하였다. 광조사 시스템은 마이크로 컨트롤러, FPGA, TLC5941 및 고휘도 LED를 이용하여 설계 및 제작하였으며 광조사 시간, 강도, 주기 등 세포 증식에 영향을 칠 수 있는 다양한 변수들의 제어가 가능하도록 하였다. 또한 세포 배양에 사용되는 인큐베이터 내부의 조사가 용이하도록 탈부착이 가능한 모듈화 된 LED를 설계 제작하여 세포 증식에서 발생 가능한 생물학적 변수를 최소화하였다.

  • PDF

Digitally Controlled Single-inductor Multiple-output Synchronous DC-DC Boost Converter with Smooth Loop Handover Using 55 nm Process

  • Hayder, Abbas Syed;Park, Young-Jun;Kim, SangYun;Pu, Young-Gun;Yoo, Sang-Sun;Yang, Youngoo;Lee, Minjae;Hwang, Keum Choel;Lee, Kang-Yoon
    • Journal of Power Electronics
    • /
    • 제17권3호
    • /
    • pp.821-834
    • /
    • 2017
  • This paper reports on a single-inductor multiple-output step-up converter with digital control. A systematic analog-to-digital-controller design is explained. The number of digital blocks in the feedback path of the proposed converter has been decreased. The simpler digital pulse-width modulation (DPWM) architecture is then utilized to reduce the power consumption. This architecture has several advantages because counters and a complex digital design are not required. An initially designed unit-delay cell is adopted recursively for the construction of coarse, intermediate, and fine delay blocks. A digital limiter is then designed to allow only useful code for the DPWM. The input voltage is 1.8 V, whereas output voltages are 2 V and 2.2 V. A co-simulation was also conducted utilizing PowerSim and Matlab/Simulink, whereby the 55 nm process was employed in the experimental results to evaluate the performance of the architecture.