• Title/Summary/Keyword: Step frequency

Search Result 1,427, Processing Time 0.039 seconds

Statistical Ranking Recommendation System of Hangul-to-Roman Conversion for Korean Names (한글-로마자 인명 변환의 통계적 순위 추천 시스템)

  • Lee, Jung-Hun;Kim, Minho;Kwon, Hyuk-Chul
    • Journal of KIISE
    • /
    • v.44 no.12
    • /
    • pp.1269-1274
    • /
    • 2017
  • This paper focuses on the Hangul-to-roman conversion of Korean names. The proposed method recognizes existing notation and provides results according to the frequency of use. There are two main reasons for the diversity in Hangul-to-roman name conversion. The first is the indiscreet use of varied notation made domestically and overseas. The second is the customary notation of current notation. For these reasons, it has become possible to express various Roman characters in Korean names. The system constructs and converts data from 4 million people into a statistical dictionary. In the first step, the person's name is judged through a process matching the last name. In the second step, the first name is compared and converted in the statistical dictionary. In the last step, the syllables in the name are compared and converted, and the results are ranked according to the frequency of use. This paper measured the performance compared to the existing service systems on the web. The results showed a somewhat higher performance than other systems.

Kinematic Analysis of Hurdle Clearance Technique for 110-m Men's Hurdlers at IAAF World Championships, Daegue 2011 (2011 대구세계육상선수권대회 110m 허들 선수의 허들링 기술 동작의 운동학적 분석)

  • Park, Young-Jin;Ryu, Jae-Kyun;Ryu, Ji-Seon;Kim, Tae-Sam;Hwang, Won-Seob;Park, Sang-Kyoon;Yoon, Suk-Hoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.21 no.5
    • /
    • pp.529-540
    • /
    • 2011
  • The purpose of this study was to evaluate the kinematic characteristics of $5^{th}$ and $6^{th}$ hurdle clearances during the final of the 110-m hurdles at the IAAF World Championships, Daegu 2011. To this end, the hurdling motions of the top 4 ranked male hurdlers in the competition were analyzed. A total of 12 cameras were used to record their motions, with a sampling frequency of 120 Hz. The cameras were calibrated using $11{\times}2{\times}1\;m$ control objects that covered all of the lanes (1st~8th lanes). After analyzing all the data, we arrived at the following results. In the take-off phase, all athletes revealed similar take-off times (CT), and similar distances from the take-off to hurdleto (L1) and hurdle to landing (L2). In particular, Turner, ranked $3^{rd}$, had an inconsistent L2 and may need further training to correct it. In the flight phase, Richardson, ranked $1^{st}$, showed the longest flight distance, whereas Xiang, who was ranked $2^{nd}$, showed the highest CG height from the hurdle. For the step patterns, to increase the pitch frequency, Richardson and Xiang used shorter 3-step lengths than Turner and Oliver.

Synthesis and Luminescence Properties of Sr/SmSi5N8:Eu2+ Phosphor for White Light-Emitting-Diode

  • Luong, Van Duong;Lee, Hong-Ro
    • Journal of the Korean institute of surface engineering
    • /
    • v.47 no.4
    • /
    • pp.192-197
    • /
    • 2014
  • Red-emitting nitride phosphors recently attracted considerable attention because of their high thermal stability and high color rendering index properties. For excellent phosphor of white light-emitting-diode, ternary nitride phosphor of $Sr/SmSi_5N_8:Eu^{2+}$ with different $Eu^{2+}$ ion concentration were synthesized by solid state reaction method. In this work, red-emitting nitride $Sr/SmSi_5N_8:Eu^{2+}$ phosphor was successfully synthesized by using multi-step high frequency induction heat treatment. The effects of molar ratio of component and experimental conditions on luminescence property of prepared phosphors have been investigated. The structure and luminescence properties of prepared $Sr/SmSi_5N_8:Eu^{2+}$ phosphors were investigated by XRD and photoluminescence spectroscopy. The excitation spectra of $Sr/SmSi_5N_8:Eu^{2+}$ phosphors indicated broad excitation wavelength range of 300 - 550 nm, namely from UV to visible area with distinct enhanced emission peaks. With an increase of $Eu^{2+}$ ion concentration, the peak position of emission in spectra was red-shifted from 613 to 671 nm. After via multi-step heat treatment, prepared phosphor showed excellent luminescence properties, such as high emission intensity and low thermal quenching, better than commercial phosphor of $Y_3Al_5O_{12}:Ce^{3+}$. Using $Eu_2O_3$ as a raw material for $Eu^{2+}$ dopant with nitrogen gas flowing instead of using commercial EuN chemical for $Sr/SmSi_5N_8:Eu^{2+}$ synthesis is one of characteristic of this work.

Development of Frequency Domain Matching for Automated Mosaicking of Textureless Images (텍스쳐 정보가 없는 영상의 자동 모자이킹을 위한 주파수영역 매칭기법 개발)

  • Kim, Han-Gyeol;Kim, Jae-In;Kim, Taejung
    • Korean Journal of Remote Sensing
    • /
    • v.32 no.6
    • /
    • pp.693-701
    • /
    • 2016
  • To make a mosaicked image, we need to estimate the geometric relationship between individual images. For such estimation, we needs tiepoint information. In general, feature-based methods are used to extract tiepoints. However, in the case of textureless images, feature-based methods are hardly applicable. In this paper, we propose a frequency domain matching method for automated mosaicking of textureless images. There are three steps in the proposed method. The first step is to convert color images to grayscale images, remove noise, and extract edges. The second step is to define a Region Of Interest (ROI). The third step is to perform phase correlation between two images and select the point with best correlation as tiepoints. For experiments, we used GOCI image slots and general frame camera images. After the three steps, we produced reliable tiepoints from textureless as well as textured images. We have proved application possibility of the proposed method.

RESONANCE FREQUENCY ANALYSIS IN NON-SUBMERGED, INTERNAL TYPE IMPLANT WITH SINUS AUGMENTATION USING DEPROTEINIZED BOVINE BONE MINERAL (이종골을 이용한 상악동 측벽거상술과 동시 식립한 임프란트에서 안정성에 대한 공진 주파수 분석)

  • Lee, Ju-Hyon;Min, Hyun-Gi;Lee, Jin-Sook;Kim, Myung-Rae;Kang, Na-Ra
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.6
    • /
    • pp.554-560
    • /
    • 2008
  • In posterior maxilla, it is difficult to achieve primary stability of implants due to sinus pneumatization, alveolar bone loss, and low bone quality. The accurate and objective primary stability assessment is important for good prognosis of implants. Purpose: The aim of this study was to assess the primary stability of the non-submerged, internal type implants with maxillary sinus augmentation using deproteinized bovine bone mineral by a resonance frequency analyzer, when residual alveolar bone height is under 8mm Materials and methods: A total of 20 implants was placed into 5 grafted maxillary sinuses in 5 patients. Deproteinized bovine bone mineral (Bio-$Oss^{(R)}$) was used as graft material. SS II implants (diameter 4.1mm, and length 11.5mm, SLA suface)) were placed. All of the patients received maxillary sinus graft procedure by 1-step technique. Residual bone height was $1.3{\sim}7.8mm$ (mean 4.4mm) measured by panorama radiography. After implant placement, RFA was measured at 4,8,12,20 weeks. The results were divided into 2 groups; RFA value under 4mm and over 5mm of bone height. It was statistically analyzed. Results: 1. The primary stability of implants was increased with time 2. The RFA value was above 65 ISQ at 12 weeks 3. There was no correlation between RFA and residual alveolar bone height in maxillary sinus augmentation by 1-step technique. Conclusion: 1-step surgical procedure is a feasible option for patients with as little as 4mm residual alveolar bone height, when utilizing non-submerged, internal type implants with xenografts.

Development of Ceramic Filter Using Non Radiative Microstrip Line In Millimeter-Wave (비방사 마이크로 스트립 선로를 이용한 밀리미터 대역의 세라믹 필터 개발)

  • Shin, Cheon-Woo;Kim, Tae-Heon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.6A
    • /
    • pp.648-656
    • /
    • 2007
  • This paper is about band pass filter, using Ceramics in the condition of center frequency 370Hz at milli-wave. The band pass filter is applied to Broadband Convergence Network, representing WLL(Wireless Local Loop) and LMDS(Local Multi-point Distribution Service). Sticking ceramic between strip line on a dielectric material substrate with which conductor's covers upper and basal surface, One will house the exterior by using structural resonance. In this Non Radiative Microstrip Line Filter structure, based upon simulations, generalized the two formulas finding resonant frequency of 1step ceramic resonator and bandwidth of 4step ceramic resonator. Also, As a result of experiment, using Network Analyzer, about created a experiment of structure based on the simulation result of 4-step ceramic resonator, It showed good characteristic of targeted bandwidth, comparing simulated result of 36.58GHz$\sim$37.650GHz with experimented result of 36.6GHz$\sim$37.65GHz.

Device and Piezoelectric Characteristics of Pb(Mn1/3Sb2/3) O3-PZT Ceramics for Piezoelectric Transformer

  • Sohn, Joon-Ho;Heo, Soo-Jeong;Sohn, Jeong-Ho;Lee, Joon-Hyung;Jung, Woo-Hwan;Kim, Dong-Bum;Cho, Sang-Hee
    • The Korean Journal of Ceramics
    • /
    • v.5 no.2
    • /
    • pp.171-177
    • /
    • 1999
  • In the $(Pb_{1-x}M_x)[(Mn_{1/3}Sb_{2/3})_{0.05}Zr_yTi_{0.95-y}]O_3$ system, where M=Ca and Sr, the piezoelectric properties were evaluated to examine the possibility of application to piezoelectric transformer. A Rosen-type piezoelectric transformer was formed, then the electrical properties of voltage step-up ratio, frequency characteristics etc. were analysed. The morphotropic phase boundary was determined to be y=0.475 in $Pb[(Mn_{1/3}Sb_{2/3})_{0.05}Zr_yTi_{0.95-y}]O_3$ system and the piezoelectric properties of this composition was kp=0.59, Qm=1600 and $\varepsilon_r$=1150. Moreover, when 1-2 mol% of Sr are substituted, enhanced piezoelectric properties of kp=0.61, Qm=1600 and $\varepsilon_r$=1400 were shown. The temperature rising (ΔT) of a piezoelectric transformer with $Pb[Mn_{1/3}Sb_{2/3})_{0.05}Zr_{0.475}Ti_{0.475})]O_3 $ composition was $10^{\circ}C$, and the voltage step-up ratio was 500 when the output voltage was 4000V, whereas the ΔT was below $3^{\circ}C$ and the resonant frequency variation ($\Delta f_r$) as a function of load resistance was below 5% when the output voltage was 2000 V. These characteristics are superior to the properties of materials, which were substituted by Ca or without substitution.

  • PDF

Analysis of Folded Dipole Antenna by Moment Methods (모멘트법에 의한 접힌 안테나의 특성해석)

  • 이상설
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.15 no.2
    • /
    • pp.15-18
    • /
    • 1978
  • The impedance step up ratio and variations of input admittances of the folded dipole antenna are calculated by the moment method. The results are compared with those calculated by Guertler's formula. The input admittance of the folded dipole antenna has the maximum value at the frequency somewhat lower than the resonance frequency and its susceptance which has periodic properly is null lot several different frequencies if radius ratio of two elements is not very large. Frequency characteristic of folded dipole antenna is improved when its radius ratio is increased.

  • PDF

Load Frequency Control of Power System Based on Fuzzy Inference Technique (피지 추론을 이용한 전력계통의 부하 주파수 제어)

  • Chung, D.I.;Kim, H.J.;Lee, J.T.;Chung, H.H.;Park, Y.S.
    • Proceedings of the KIEE Conference
    • /
    • 1991.11a
    • /
    • pp.75-79
    • /
    • 1991
  • This paper presents a Fuzzy Control Technique to improve the load frequency control dynamics of a power system for a given load perturbation(step-function waveform). A related simulation results follow and show that the optimized rules by the proposed technique are effective for reduction of overshoot and deviation of load frequency in stedy-state, and for minimization of settling time.

  • PDF

Flow-Induced Vibration Signal Analysis of the FIV Test Loop (FIV 시험루프의 유동기인 진동 신호분석)

  • Lee, Kang-Hee;Kang, Heung-Soek;Yoon, Kyung-Ho;Song, Kee-Nam
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.601-606
    • /
    • 2004
  • Vibration spectrums of the test loop according to flow conditions were analyzed in order to identify the sources of vibration at peak frequencies. While a flow condition of the sweep test was changed by varying pump rotational speed from 450 rpm to 1500 rpm by the step 150 rpm, midspan acceleration of the test section in width-direction and dynamic pressure perturbation in the test section were measured. Other sources of vibration due to the flow structure interactions, such as acoustic resonance, blade pulsing frequency and bellows wrinkles, were investigated. Pressure perturbation in the section and acoustic resonance due to branch pipe give major effects to the vibration of the test section in high frequency range of 1.5 kHz to 2.8 kHz.

  • PDF