생체내 혈관조형술을 이용한 관상동맥의 3차원 형상화 및 혈류특성 해석 (Three-Dimensional Model Construction and Blood Flow Analysis of Coronary Artery using In-vivo Angiography)

  • 노형운;서상호;권혁문;이병권
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.753-758
    • /
    • 2003
  • The purpose of the present study was to establish the mechanism of the generation of atherosclerosis by analyzing the hemodynamic variables in the coronary artery where atherosclerosis occurs frequently. From the previous results, the stenosis phenomena due to atherosclerosis were related to not only biochemical reaction between blood and blood vessel but also the hemodynamic factors like flow separation and oscillatory wall shear stress. The present study aimed to investigate the causes of the generation and progression of atherosclerosis in the coronary artery. This study also aimed to develop the softwares which generate automatically three dimensional vascular models obtained by the angiogram images and the computer vision techniques. In the present study, the flow patterns for full three-dimensional hemodynamic characteristics were analyzed. To understand the three-dimensional hemodynamic characteristics, the wall shear stress distributions and secondary flows were investigated quantitatively.

  • PDF

Dynamic response of heat and mass transfer in blood flow through stenosed bifurcated arteries

  • Charkravarty S.;Sen S.
    • Korea-Australia Rheology Journal
    • /
    • 제17권2호
    • /
    • pp.47-62
    • /
    • 2005
  • The present study deals with a mathematical model describing the dynamic response of heat and mass transfer in blood flow through bifurcated arteries under stenotic condition. The geometry of the bifurcated arterial segment possessing constrictions in both the parent and the daughter arterial lumen frequently appearing in the diseased arteries causing malfunction of the cardiovascular system, is formulated mathematically with the introduction of the suitable curvatures at the lateral junction and the flow divider. The blood flowing through the artery is treated to be Newtonian. The nonlinear unsteady flow phenomena is governed by the Navier-Stokes equations while those of heat and mass transfer are controlled by the heat conduction and the convection-diffusion equations respectively. All these equations together with the appropriate boundary conditions describing the present biomechanical problem following the radial coordinate transformation are solved numerically by adopting finite difference technique. The respective profiles of the flow field, the temperature and the concentration and their distributions as well are obtained. The influences of the stenosis, the arterial wall motion and the unsteady behaviour of the system in terms of the heat and mass transfer on the blood stream in the entire arterial segment are high­lighted through several plots presented at the end of the paper in order to illustrate the applicability of the present model under study.

요추부 극돌기간 고정기구의 생체역학적 해석과 소형화 및 유연성 향상 설계 (Biomechanical Analysis of Lumbar Interspinous Process Fixators and Design of Miniaturization and Advanced Flexibility)

  • 박정홍;허순;이성재;손권
    • 대한기계학회논문집A
    • /
    • 제30권12호
    • /
    • pp.1509-1517
    • /
    • 2006
  • The intervertebral fusion was reported to increase the degeneration of the neighboring region. Recently, a new technique of inserting an interspinous process fixator has been introduced to minimize the degenerative change in the lumbar spine. This study analyzed biomechanical effects of the fixator in the lumbar spine, and designed a new prototype to improve flexibility of the fixator with a reduced size. The evaluation was based on the displacement, stiffness and von-Mises stress obtained from the mechanical test and finite element analysis. A finite element lumbar model of L1 to L5 was constructed. The finite element model was used to analyze intervertebral fusion, insertion of a commercial fixator and a new prototype. The range of motion of intervertebral segments and pressures at vertebral discs were calculated from FEA. The results showed that the stiffness of the prototype was reduced by 32.9% than that of the commercial one.

췌담관 합류이상의 실험동물 모델 (An Experimental Animal Model of Anomalous Pancreaticobiliary Duct Union)

  • 한석주;장항석;김종성;한진수;김호근;황의호
    • Advances in pediatric surgery
    • /
    • 제4권2호
    • /
    • pp.100-109
    • /
    • 1998
  • The anomalous pancreaticobiliary duct union (APBDU) might cause the formation of choledochal cyst and malignancies of hepatopancreaticobiliary system. The purpose of this study is to make an experimental animal model of APBDU similar to that of human. One to two-month-old Mongrel dogs (n=12) were divided into two groups; the control group (n=2) had a sham operation performed, and in the experimental group (n=10) the end of distal ' common bile duct (CBD) was anastomosed to the side of the dorsal pancreatic duct making APBDD. Serum was obtained for chemical analysis on the 10th postoperative day. The dogs were sacrificed at the 5th week (n=3), the 6th week (n=3), the 7th week (n=2), the 8th week (n=2) and the 6th month (n=2) after the experimental surgery. With sacrifice, operative cholangiogram was taken, and bile juice was obtained for chemistry and bacterial culture. The en-bloc specimens of the hepatopancreaticobiliary system were removed for microscopic examination. Serum and bile juice amylase levels were elevated in the experimental group(n=10), but not in the control group(n=2). Operative cholangiograms of control group revealed no evidence of bile duct dilatation.. On the other hand, the bile duct in the experimental group was markedly dilated without any evidence of stenosis at the anastomosis site (n=10). Histologic examination of the hepatopancreaticobiliary system in the experimental group resembled the findings of choledochal cyst in human. The APBDU of this animal model can produce bile duct dilatation by pancreaticobiliary reflux. We think that this animal model can be potentially promising for the research about the APBDU associated hepatopancreaticobiliary diseases.

  • PDF

NaOH 용액을 이용한 부식성 식도 협착 동물모델 형성에 관한 연구 (Corrosive Stricture Model Induced-Esophageal Burn : Animal Pilot Data)

  • 김민태
    • 한국방사선학회논문지
    • /
    • 제15권5호
    • /
    • pp.643-647
    • /
    • 2021
  • 본 연구의 목적은 부식성 식도 협착 모델을 만들어 전임상연구 모델로서의 가능성과 활용성을 알아보고자 한다. 20마리의 백서를 Healthy group / Corrosive group으로 나누고, 부식성 화상은 하부 식도에 30% NaOH를 사용하여 모델링하였다. 수술 후 행동 및 체중 변화를 매주 모니터링했습니다. 수술 후 3주 뒤에 식도조영술을 시행한 후 모든 쥐를 안락사 희생시키고 병리학적 분석을 위해 하부식도를 파라핀블럭 제작하였다. 부식성 협착에 대한 기술적 성공은 100%였습니다. 총 2마리의 백서가 연하곤란과 관련된 부식성 화상으로 Corrosive group에서 14일 이내에 사망했다. 식도 협착 비율은 Corrosive group이 Healthy group보다 유의하게 높았다(각각 40.1 ± 9.2% 및 1.4 ± 7.2%; p = 0.001). 조직 증식 비율도 Corrosive group에서 유의하게 더 높았다(각각 62.5 ± 9% 및 22.08 ± 6%; p = 0.001). 결론적으로, 30% 농도의 NaOH를 이용한 백서 부식성 모델은 전임상 연구 평가 툴로서 다양한 부식성 식도 협착 치료 전임상 연구를 수행할 수 있을 것이라 사료된다.

Computational Study on the Hemodynamics of the Bypass Shunt Directly Connecting the left Ventricle to a Coronary Artery

  • Shim Eun Bo;Lee Byung Jun;Ko Hyung Jong
    • Journal of Mechanical Science and Technology
    • /
    • 제19권5호
    • /
    • pp.1158-1168
    • /
    • 2005
  • A shunt from the left ventricle to the left anterior descending artery is being developed for coronary artery occlusive disease, in which the shunt or conduit connects the the left ventricle (LV) with the diseased artery directly at a point distal to the obstruction. To aid in assessing and optimizing its benefit, a computational model of the cardiovascular system was developed and used to explore various design conditions. Computational fluid dynamic analysis for the shunt hemodynamics was also done using a commercial finite element package. Simulation results indicate that in complete left anterior descending artery (LAD) occlusion, flow can be returned to approximately 65% of normal, if the conduit resistance is equal for forward and reverse flow. The net coronary flow can increase to 80% when the backflow resistance is infinite. The increases in flow rate produced by asymmetric flow resistance are enhanced considerably for a partial LAD obstruction, since the primary effect of resistance asymmetry is to prevent leakage back into the ventricle during diastole. Increased arterial compliance has little effect on net flow with a symmetric shunt, but considerably augments it when the resistance is asymmetric. The computational results suggest that an LV-LAD conduit will be beneficial when the resistance due to artery stenosis exceeds 27 PRU, if the resistance is symmetric. Fluid dynamic simulations for the shunt flow show that a recirculating region generated near the junction of the coronary artery with the bypass shunt. The secondary flow is induced at the cutting plane perpendicular to the axis direction and it is in the attenuated of coronary artery.

극돌기 절골술과 추궁판 절제술에 대한 생역학적 비교 (The Comparison of Biomechanical Changes between Spinous Process Osteotomy and Conventional Laminectomy)

  • 강경탁;손주현;전흥재;김호중
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1651-1654
    • /
    • 2008
  • Previous reports have introduced the technique of spinous process osteotomy to decompress spinal stenosis, a procedure which aims to afford excellent visualization while minimizing destruction of tissures not directly involved in the pathologic process. However, bio-mechanically it has not been investigated whether the sacrifice of posterior spinous process might have potential risk of spinal instability or not, even though supra-spinous and inter-spinous ligament are preserved. Therefore the aim of this study is to evaluate the bio-mechanical properties after spinous process osteotomiy, using finite element analysis. In the model of spinous process osteotomy the increase of stress in the disc and segmental rangesof motions were not changed significantly. It is due to the fact that the instability of lumbar spine has been maintained by the two-types of ligaments compared with the prior surgical technique. Therefore, according to the finite element result on this study, these osotetomy was considered to be a clinicallysafe surgical procedure and could not cause the instability of patient.

  • PDF

초음파 영상 분석을 위한 3D 프린팅 기반 미세유체소자 (Microfluidic Device for Ultrasound Image Analysis based on 3D Printing)

  • 강동국;홍현지;염은섭
    • 한국가시화정보학회지
    • /
    • 제16권1호
    • /
    • pp.15-20
    • /
    • 2018
  • For the measurement of biophysical properties related with cardiovascular diseases (CVD), various microfluidic devices were proposed. However, many devices were monitored by optical equipment. Ultrasound measurement to quantify the biophysical properties can provide new insights to understand the cardiovascular diseases. This study aims to check feasibility of microfluidic device for ultrasound image analysis based on 3D printer. To facilitate acoustic transmission, agarose solution is poured around 3D mold connected with holes of the acrylic box. By applying speckle image velocimetry(SIV) technique, flow information in the bifurcated channel was estimated. Considering that ultrasound signal amplitude is determined by red blood cell (RBC) aggregation, RBC aggregation in the bifurcated channel can be estimated through the analysis of ultrasound signal. As examples of microfluidic device which mimic the CVD model, velocity fields in microfluidic devices with stenosis and aneurysm were introduced.

극돌기 절골술과 추궁판 절제술에 대한 생체역학적 비교 (The Comparison of Biomechanical Changes between Spinous Process Osteotomy and Conventional Laminectomy)

  • 강경탁;전흥재;손주현;김호중;문성환;이환모;김가연
    • 대한기계학회논문집A
    • /
    • 제33권7호
    • /
    • pp.645-651
    • /
    • 2009
  • Previous studies have introduced the technique of spinous process osteotomy to decompress spinal stenosis, a procedure which aims to afford excellent visualization while minimizing destruction of tissues not directly involved in the pathologic process. However, biomechanically it has not been investigated whether the sacrifice of posterior spinous process might have potential risk of spinal instability or not, even though supra-spinous and inter-spinous ligaments are preserved. Therefore the aim of this study is to evaluate the biomechanical properties after spinous process osteotomy, using finite element analysis. The model of spinous process osteotomy exhibited no significant increase in disc stress or change in segmental range of motion. It is due to the fact that the instability of lumbar spine has been maintained by the two-types of ligaments compared with the prior surgical technique. Therefore, according to the finite element result on this study, this osotetomy was considered to be a clinically safe surgical procedure and could not cause the instability of the lumbar spine.

타액선 도관세포의 관류 배양 기술 개발 (Development of the Three-Dimensional Perfusion Culture Technology for the Salivary Ductal Cells)

  • 김지원;김정미;최정석
    • International journal of thyroidology
    • /
    • 제11권2호
    • /
    • pp.160-166
    • /
    • 2018
  • Background and objectives: Salivary hypofunction is one of the common side effects after radioiodine therapy, and its pathophysiology is salivary ductal stenosis resulting from ductal cell injury. This study aimed to develop the functional culture environment of human parotid gland ductal cells in in vitro three-dimensional perfusion culture system. Materials and Methods: We compared plastic dish culture method and three-dimensional culture system containing Matrigel and nanofiber. Morphogenesis of reconstituted salivary structures was assessed by histomorphometry. Functional characteristics were assessed by immunohistochemistry and reverse transcription polymerase chain reaction (aquaporin 5, CK7, CK18, connexin 43, and p21). In addition, we designed the media perfusion culture system and identified higher rate of cell proliferation and expression of connexin 43 in perfusion system comparing to dish. Results: Human parotid ductal cells were well proliferated with the ductal cell characters under environment with Matrigel. In the presence of Matrigel, aquaporin 5, CK18 and connexin 43 were more expressed than 2D dish and 3D nanofiber setting. In the media perfusion culture system, ductal cells in 3D culture media showed higher cells count and connexin 43 expression compared to 2D dish. Conclusion: This in vitro ductal cell perfusion culture system using Matrigel could be used to study for radioiodine induced sialadenitis model in vivo.