References
- Weiner, B. K., Fraser, R. D. and Peterson, M., 1999, 'Spinous Process Osteotomies to Facilitate Lumbar Decompressive Surgery,' Spine, Vol. 24, No. 1, pp. 62-66 https://doi.org/10.1097/00007632-199901010-00015
- Park, S. Y., Kim. H. J., Moon, S. Y. and Lee, H. M., 2008, 'Decompression for Lumbar Spinal Stenosis a Degenerative Spondylolisthesis Using Spinous Process Osteotomy Technique,' ISSLS, p. 265
- Kim, Y. and Vanderby, R., 2000, 'Finite Element Analysis of Interbody Cages in a Human Lumbar Spine,' Computer Methods in Biomechanics and Biomedical Engineering, Vol. 3, pp. 257-272 https://doi.org/10.1080/10255840008915270
- Goel, V. K., Grauer, J. N., Patel, T., Biyani, A., Sairyo, K., Vishnubhotla, S., Matyas, A., Cowgill, I., Shaw, M., Long, R., Dick, D., Panjabi, M. M. and Serhan, H., 2005, 'Effects of Charite Artificial Disc on the Implanted and Adjacent Spinal Segments Mechanics Using a Hybrid Testing Protocol,' Spine, Vol. 30, No. 24, pp. 2755-2764 https://doi.org/10.1097/01.brs.0000195897.17277.67
- Palm, W. J., Rosenberg, W. S. and Keaveny, T. M, 2002, 'Load Transfer Mechanisms in Cylindrical Interbody Cage Constructs,' Spine, Vol. 27, No. 19, pp. 2101-2107 https://doi.org/10.1097/00007632-200210010-00005
- Shirazi-Adl, S. A., Shrivastava, S. C. and Ahmed, A. M., 1984, 'Stress Analysis of the Lumbar Disc-Body Unit in Compression. a Three-Dimensional Nonlinear Finite Element Study,' Spine, Vol. 9, No. 2, pp. 120-134 https://doi.org/10.1097/00007632-198403000-00003
- Guan, Y., Yoganandan, N., Zhang, J., Pintar, F., Cusick, J., Wolfla, C. E. and Maiman, D. J., 2006, 'Validation of a Clinical Finite Element Model of the Human Lumbosacral Spine,' Medical and Biological Engineering and Computing, Vol. 44, No. 8, pp. 633-641 https://doi.org/10.1007/s11517-006-0066-9
- Wagner, D. and Lotz, J., 2004, 'Theoretical Model and Experimental Results for the Nonlinear Elastic Behavior of Human Annulus Fibrosus,' Journal of Orthopaedic Research, Vol. 22, No. 4, pp. 901-909 https://doi.org/10.1016/j.orthres.2003.12.012
- Pintar, F. A., Yoganandan, N., Myeres, T., Elhagediab, A. and Sances Jr, A., 1992, 'Biomechanical Properties of Human Lumbar Spine Ligaments,' Journal of Biomechanics, Vol. 25, No. 11, pp. 1351-1356 https://doi.org/10.1016/0021-9290(92)90290-H
- Goel, V. K., Kim, Y. E., Lim, T. H. and Weinstein, J. N., 1988, 'An Analytical Investigation of the Mechanics of Spinal Instrumentation,' Spine, Vol. 13, No. 9, pp. 1003-1011 https://doi.org/10.1097/00007632-198809000-00007
- Yamamoto, I., Panjabi, M. M., Crisco, T. and Oxland, T., 1989, 'Three-Dimensional Movement of the Whole Lumbar Spine and Lumbosacral Joint,' Spine, Vol. 14, pp. 1256-1260 https://doi.org/10.1097/00007632-198911000-00020
- Chen, C. S., Cheng, C. K., Liu, C. L. and Lo, W. H., 2001, 'Stress Analysis of the Disc Adjacent to Interbody Fusion in Lumbar Spine,' Medical Engineering & Physics, Vol. 23, No. 7, pp. 483-489 https://doi.org/10.1016/S1350-4533(01)00076-5
- Shirazi-Adl, A., 1994, 'Biomechanics of the Lumbar Spine in Sagittal/Lateral Moments,' Spine, Vol. 19, No. 21, pp. 2407-2414 https://doi.org/10.1097/00007632-199411000-00007
- Cardoso, M. J., Dmitriev, A. E., Helgeson, M., Lehman, R. A., Kuklo, T. R. and Rosner, M. K., 2008, 'Does Superior-Segment Facet Violation or Laminectomy Destabilize the Adjacent Level in Lumbar Transpedicular Fixation? An in Vitro Human Cadaveric Assessment,' Spine, Vol. 33, No. 26, pp. 2868 https://doi.org/10.1097/BRS.0b013e31818c63d3
- Yoganandan, N., Myklebust, J. B., Ray, G. and Sances, A. Jr, 1987, 'Mathematical and Finite Element Analysis of Spine Injuries,' Critical Reviews in Biomedical Engineering, Vol. 15, No. 1, pp. 29-93
- Yoganandan, N., Kumaresan, S., Voo, L. and Pintar, F., 1996, 'Finite Element Applications in Human Cervical Spine Modeling,' Spine, Vol. 21, No. 15, pp. 1824-1834 https://doi.org/10.1097/00007632-199608010-00022
- Yoganandan, N., Kumaresan, S., Voo, L. and Pintar, F. A., 1997, 'Finite Element Model of the Human Lower Cervical Spine: Parametric Analysis of the C4-C6 Unit,' Journal of Biomechanical Engineering, Vol. 119, No. 1, pp. 87-92 https://doi.org/10.1115/1.2796070
- Yoganandan, N., Kumaresan, S. and Pintar, F. A., 2001, 'Biomechanics of the Cervical Spine. Part 2. Cervical Spine Soft Tissue Responses and Biomechanical Modeling,' Clinical Biomechanics, Vol. 16, No. 1, pp. 1-27 https://doi.org/10.1016/S0268-0033(00)00074-7
- Goel, V. K., Kong, W. Z., Han, J. S., Weinstein, J. N. and Gilbertson, L. G., 1993, 'A Combined Finite Element and Optimization Investigation of Lumbar Spine Mechanics with and Without Muscles,' Spine, Vol. 18, pp. 1531-1541 https://doi.org/10.1097/00007632-199318110-00019
- Ivanov, A., Faizan, A., Sairyo, K., Ebranheim, N., Biyani, A. and Goel, V. K., 2007, 'Minimally Invasive Decompression for Lumbar Spinal Canal Stenosis in Younger Age Patients Could Lead to Higher Stresses in the Remaining Neural Arch-A Finite Element Investigation,' Minimally Invasive Neurosurgery, Vol. 50, No. 1, pp. 18-22 https://doi.org/10.1055/s-2006-947996
- Rosen, C., Rothman, S., Zigler, J. and Capen, D., 1991, 'Lumbar Facet Fracture as a Possible Source of Pain After Lumbar Laminectomy,' Spine, Vol. 16, pp. 234-238 https://doi.org/10.1097/00007632-199106001-00011
Cited by
- Mechanical Evaluation of Posterior Dynamic Omega-wire Stabilization System vol.36, pp.11, 2012, https://doi.org/10.3795/KSME-B.2012.36.11.1099