• Title/Summary/Keyword: Stem Cup

Search Result 15, Processing Time 0.021 seconds

Dual Mobility Cup for Revision of Dislocation of a Hip Prosthesis in a Dog with Chronic Hip Dislocation

  • Jaemin Jeong;Haebeom Lee
    • Journal of Veterinary Clinics
    • /
    • v.39 no.6
    • /
    • pp.390-394
    • /
    • 2022
  • A 6-year-old, 36.5 kg castrated male Golden Retriever presented for revision surgery for left total hip replacement. The patient underwent removal of the cup and head implants due to unmanageable prosthetic hip dislocation, despite revision surgery. On physical examination, the dog showed persistent weight-bearing lameness after exercise of the left hindlimb with mild muscle atrophy. Radiographic examination revealed dorsolateral displacement of the femur with a remnant stem and bony proliferation around the cranial and caudal acetabulum rims. The surgical plan was to apply the dual mobility cup to increase the range of motion and jump distance to correct soft tissue elongation and laxity caused by a prolonged period of craniodorsal dislocation of the femur. The preparation of the acetabulum for cup fixation was performed with a 29-mm reamer, and the 29.5-mm outer shell was fixed with five 2.4-mm cortical screws. The head and medium neck of the dual-mobility system were placed on the cup, and the hip joint was reduced between the neck and stem. The dog exhibited slight weight bearing on a controlled leash walk the day after surgery. The patient was discharged 2 weeks postoperatively without any complications. Six months postoperatively, osseointegration and a well-positioned cup implant were observed, and the dog showed excellent limb function without hip dislocation until 18 months of phone call follow-up.

Surgeon's Experience and Accuracy of Preoperative Digital Templating in Primary Total Hip Arthroplasty

  • Maria Surroca;Silvia Miguela;Agusti Bartra-Ylla;Jorge H. Nunez;Francesc Angles-Crespo
    • Hip & pelvis
    • /
    • v.36 no.2
    • /
    • pp.129-134
    • /
    • 2024
  • Purpose: Preoperative planning has become essential in performance of total hip arthroplasty (THA). However, data regarding the effect of the planner's experience on the accuracy of digital preoperative planning is limited. The objective of this study was to assess the accuracy of digital templating in THA based on the surgeon's experience. Materials and Methods: A retrospective study was conducted. An analysis of 98 anteroposterior pelvic radiographs, which were individually templated by four surgeons (two hip surgeons and two orthopaedic residents) using TraumaCad® digital planning, was performed. A comparison of preoperatively planned sizes with implanted sizes was performed to evaluate the accuracy of predicting component size. The results of preoperative planning performed by hip surgeons and orthopaedic residents were compared for testing of the planner's experience. Results: Femoral stem was precisely predicted in 32.4% of cases, acetabular component in 40.3%, and femoral offset in 76.7%. Prediction of cup size showed greater accuracy than femoral size among all observers. No differences in any variable were observed among the four groups (acetabular cup P=0.07, femoral stem P=0.82, femoral offset P=0.06). All measurements showed good reliability (intraclass correlation coefficient [ICC] acetabular cup: 0.76, ICC femoral stem: 0.79). Conclusion: The results of this study might suggest that even though a surgeon's experience supports improved precision during the planning stage, it should not be restricted only to surgeons with a high level of experience. We consider preoperative planning an essential part of the surgery, which should be included in training for orthopaedics residents.

Avoidance of Internal Resonances in Hemispherical Resonator Assemblies from Fused Quartz Connected by Indium Solder

  • Sarapuloff, Sergii A.;Rhee, Huinam;Park, Sang-Jin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.835-841
    • /
    • 2013
  • Modern solid-state gyroscopes (HRG) with hemispherical resonators from high-purity quartz glass and special surface superfinishing and ultrathin gold coating become the best instruments for precise-grade inertial reference units (IRU) targeting long-term space missions. Designing of these sensors could be a notable contribution into development of Korea as a space nation. In participial, 40mm diameter thin-shell resonator from high-purity fused quartz, fabricated as a single-piece with its supporting stem has been designed, machined, etched, tuned, tested, and delivered by STM Co. (ATS of Ukraine) several years ago; an extremely-high Q-factor (upto 10~20 millions) has been shown. Understanding of the best way how to match such a unique sensor with inner glass assembly of the gyro means how to use the high potential in a maximal extent; and this has become the urgent task. Inner quartz glass assembly has a very thin indium (In) layer soldered the resonator and its silica base (case), but effects of internal resonances between operational modal pair of the shell-cup and its side (parasitic) modes can notable degrade the potential of the sensor as a whole, instead of so low level of resonator's intrinsic losses. Unfortunately, there are special combinations of dimensions of the parts (so-called, "resonant sizes"), when intensive losses of energy occurs. The authors proposed to use the length of stem's fixture as an additional design parameter to avoid such cases. So-called, a cyclic scheme of finite element method (FEM) and ANSYS software were employed to estimate different combinations of gyro assembly parameters. This variant has no mismatches of numerical origin due to FEM's discrete mesh. The optimum length and dangerous "resonant lengths" have been found. The special attention has been paid to analyses of 3D effects in a cup-stem transient zone, including determination of a difference between the positions of geometrical Pole of the resonant hemisphere and of its "dynamical Pole", i.e., its real zone of oscillation node. Boundary effects between the shell (cup) and 3D short "beams" (inner and outer stems) have been ranged. The results of the numerical experiments have been compared with the classic model of a quasi-hemispherical shell band with inextensional midsurface, and the solution using Rayleigh's functions of the $1^{st}$ and $2^{nd}$ kinds. To guarantee the truth of the recommended sizes to a designer of the real device, the analytical and FEM results have been compared with experimental data for a party of real resonators. The consistency of the results obtained by different means has been shown with errors less than 5%. The results notably differ from the data published earlier by different researchers.

  • PDF

The Wear Rate and Survivorship in Total Hip Arthroplasty Using a Third-generation Ceramic Head on a Conventional Polyethylene Liner: A Minimum of 15-year Follow-up

  • Bum-Jin Shim;Sung-Jin Park;Chan Ho Park
    • Hip & pelvis
    • /
    • v.34 no.2
    • /
    • pp.115-121
    • /
    • 2022
  • Purpose: The purpose of this study was to evaluate the wear and survival rates of third-generation ceramic heads on a conventional ultra-high molecular weight polyethylene liner. Materials and Methods: A total of 160 hips (147 patients with a mean age of 55.9 years) who underwent total hip arthroplasty using the third-generation ceramic head on a conventional polyethylene liner from March 1998 to August 2003 were reviewed retrospectively. Evaluation of the wear rate for 56 hips (49 patients) followed-up for at least 15 years was performed using the PolyWare program version 8 (Draftware Developers, USA). The Kaplan-Meier survivorship was also evaluated. Results: Linear wear and volumetric wear rates were 0.11±0.47 mm/year and 32.75±24.50 mm3/year, respectively. Nine revisions were performed during the follow-up period because of cup or stem loosening. The Kaplan-Meier survival rate, using cup revision or total revision total hip arthroplasty (THA) as the endpoint of analysis, was 93.7% at 15 years and 73.6% at 20 years. Conclusion: Because all revisions were performed between 15 and 20 years in our study, surgeons should pay greater attention to patients who underwent THA with ceramic-on-polyethylene bearing from 15 years postoperatively. Contemporary alumina ceramic on highly cross-linked polyethylene could certainly be a good alternative bearing couple providing better longevity.

A New Short Stem, Lodging Resistance and High Yielding Vegetable Peanut cultivar, "Jopyeong" (조숙 단경 내도복 다수성 풋땅콩 "조평")

  • Pae, Suk-Bok;Park, Chang-Hwan;Cheong, Young-Keun;Jung, Chan-Sik;Lee, Myung-Hee;Lee, Yu-Young;Hwang, Chung-Dong;Oh, Se-Kwan;Kim, Jung-Tae;Park, Keum-Yong;Kim, Wook-Han;Choi, Gyu-Hwan;Lee, Jae-Chul;Jeong, Byung-Joon;Kim, Ho-Young
    • Korean Journal of Breeding Science
    • /
    • v.40 no.1
    • /
    • pp.63-67
    • /
    • 2008
  • A new peanut cultivar "Jopyeong" (Arachis hypogaea ssp. hypogaea L.) was developed at the Yeongnam Agricultural Research Institute, NICS, in Milyang in 2006. It was developed from the cross between the very short stem cultivar "CUP brittle" and the high-yielding cultivar "Daekwang". "Jopyeong" which is Virginia plant type has 23 branch number per plant with early maturing and ellipse-shaped large kernel. Each pod has two grains with brown testa and 100 seed weight was 87g in the regional yield trials (RYT). This variety also showed more resistant to late leaf spots compared with check one. Especially it has resistance to lodging owing to short stem and erect plant type. In the regional yield trials "Jopyeong" was out-yielded than check variety by 11% with 8.37 ton/ha for fresh pod and by 4% with 3.95 ton/ha for grain.

Comparison of the Outcomes after Primary Total Hip Arthroplasty Using a Short Stem between the Modified Anterolateral Approach and Direct Anterior Approach with a Standard Operation Table (일반 수술 침대와 짧은 대퇴 주대를 이용한 인공 고관절 전 치환술의 직접 전방 도달법과 변형된 전 측방 도달법에 따른 결과 비교)

  • Park, Myung-Sik;Yoon, Sun-Jung;Choi, Seung-Min;Cho, Hong-Man;Chung, Woochull;Kang, Kyung-Rok
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.3
    • /
    • pp.244-253
    • /
    • 2019
  • Purpose: Total hip arthroplasty was performed using a direct anterior approach (DAA) on an ordinary operation table and a short femoral stem. The clinical radiographic results were evaluated by a comparison with those performed using the modified hardinge (anterolateral approach, ALA) method. Materials and Methods: From January 2013 to November 2015, 102 patients who underwent total hip arthroplasty using DAA (DAA group) and the same number of patients using ALA (ALA group), both performed by a single surgeon, were compared and analyzed retrospectively. The operation time and amounts of bleeding were compared, and the improvement in post-operative pain, ambulatory capacity and functional recovery of the hip joint were checked. The location of insertion of the acetabular cup and femoral stem were evaluated radiologically, and the complications that occurred in the two groups were investigated. Results: The amount of bleeding was significantly smaller in the DAA group (p=0.018). Up to 3 weeks postoperatively, recovery of hip muscle strength was significantly higher in the DAA group (flexion/extension strength p=0.023, abduction strength p=0.031). The Harris hip score was significantly better in the DAA group for up to 3 months (p<0.001) and the Koval score showed significantly better results in the DAA group up to 6 weeks (p≤0.001). The visual analogue scale score improvement was significantly higher in the DAA group by day 7 (p=0.035). The inclination angle (p<0.001) and anteversion angle (p<0.001) of the acetabular cup were located in the safe zone of the DAA group more than in the ALA group, and there was no statistically significant difference in the position of the femur stem and leg length difference. During surgery, two cases of greater trochanter fracture occurred in the DAA group (p=0.155). Conclusion: The DAA performed in the ordinary operation table using a short femoral stem showed post-operative early functional recovery. Because a simple to use fluoroscope was used during surgery with an anatomical position familiar to the surgeon, it is considered to be useful for the insertion of implants into the desired position and for an approach that is useful for the prevention of leg length differences.

Cementless Total Hip Arthroplasty Using Ceramic Femoral Head on Cross-Linked Ultra-High-Molecular Weight Polyethylene Liner in Patients Older than 65 Years: Minimum Five-Year Follow-Up Results (세라믹 대퇴 골두 및 교차결합 초고분자량 폴리에틸렌 라이너를 이용한 65세 이상 무시멘트형 인공 고관절 전치환술: 최소 5년 중기 추시 결과)

  • Yun, Ho Hyun;Cheong, Ji Young;Sim, Hyun Bo;Park, Jae Hong
    • Journal of the Korean Orthopaedic Association
    • /
    • v.53 no.6
    • /
    • pp.490-497
    • /
    • 2018
  • Purpose: To evaluate the utility of ceramic-on-polyethylene articular bearing surface when cementless total hip arthroplasty is performed in patients older than 65 years through an analysis of the minimum five-year follow-up results using the ceramic femoral head and cross-linked polyethylene liner. Materials and Methods: From March 2010 to September 2012, 51 patients (56 hips) who were older than 65 years were enrolled in this retrospective study. The mean age at surgery was $70.9{\pm}5.1years$ old. A clinical assessment was analyzed using the Harris hip score. For the radiographic assessment, the cup inclination and anteversion, stem alignment, and wear amount were measured. The postoperative complications were also determined. Results: The mean Harris hip score was improved from preoperative 48 points to postoperative 87 points (p<0.05). The mean cup inclination was $40.9^{\circ}{\pm}6.4^{\circ}$ and the mean cup anteversion was $20.3^{\circ}{\pm}8.1^{\circ}$. The mean cup anteversion of the elevated liner-used group (16 cases) was $14.3^{\circ}{\pm}7.9^{\circ}$ and the mean cup anteversion of the neutral liner used group (40 cases) was $22.4^{\circ}{\pm}9.1^{\circ}$ (p<0.05). The mean stem alignment angle was $0^{\circ}$ (range, varus $4^{\circ}$-valgus $4^{\circ}$). The mean linear wear amount was $0.458{\pm}0.041mm$ and the average annual linear wear rate was $0.079{\pm}0.032mm/yr$. Six cases (10.7%) of intraoperative periprosthetic femoral fractures were encountered. Conclusion: Based on these results, the use of a ceramic-on-polyethylene articular bearing surface in elderly patients with cementless total hip arthroplasty is beneficial. On the other hand, careful effort is needed to prevent intraoperative periprosthetic femoral fractures.

A New Cultivar of Gypsophila paniculata 'Double Shine' with Bright Colored Flower and Strong Stem (줄기가 강하고 밝은 화색의 절화용 안개꽃 '더블샤인' 육성)

  • Cheong, Dong-Chun;Choi, Chang-Hak;Song, Young-Ju;Lim, Hoi-Chun;Kim, Jeong-Man;Lee, Jin-Je;Lee, Jung-Soo
    • Horticultural Science & Technology
    • /
    • v.30 no.1
    • /
    • pp.93-96
    • /
    • 2012
  • 'Double Shine', a cultivar of Gypsophila paniculata was newly developed for the cut flowers by Jeollabuk-do Agricultural Research & Extension Services. It has morphological characteristics of the spreading plant type, double florets of many petals and two pistils, emarginate petal tip and cup shaped calyx. Also 'Double Shine' has several traits such as strong flower stalk, bright colored flower, narrow branching angle and more or less resistance to powdery mildew and pest injury. Furthermore, 'Double Shine' produced higher primary branches, and longer flower stalk length with internodal length and than did a check variety 'Bristol Fairy' during summer cultivation in subalpine areas. Blooming of 'Double Shine' was delayed by 16 days, its floret had broader width, compared to 'Bristol Fairy'. Moreover, 'Double Shine' produced normal flowers with two pistils and 8.5 stamens, with little production of malformed flowers in the high temperature condition.

Extracting 3D Geometry Parameters of Hip Joint for Designing a Custom-Made Hip Implant (맞춤형 인공관절 설계를 위한 인체 고관절의 3차원 형상 정보 추출)

  • Seo, Jeong-Woo;Jun, Yong-Tae
    • Korean Journal of Computational Design and Engineering
    • /
    • v.13 no.3
    • /
    • pp.200-208
    • /
    • 2008
  • Total Hip Replacement(THR) is a surgical procedure that replaces a diseased hip joint with a prosthesis. A plastic or metal cup forms the socket, and the head of the femur is replaced by a metal ball on a stem placed inside the femur. Due to the various types and shapes of human hip joint of every individual, a selected commercial implant sometimes may not be the best-fit to a patient, or it cannot be applied because of its discrepancy. Hence extracting geometry parameters of hip joint is one of the most crucial processes in designing custom-made implants. This paper describes the framework of a methodology to extract the geometric parameters of the hip joint. The parameters include anatomical axis, femoral head, head offset length, femoral neck, neck shaft angle, anteversion, acetabulum, and canal flare index. The proposed system automatically recommends the size and shape of a custom-made hip implant with respect to the patient's individual anatomy from 3D models of hip structures. The proposed procedure creating these custom-made implants with some typical examples is precisely presented and discussed in this paper.

A Basic Study on Functional Friction Surface of Artificial Joints (내마모성이 향상된 기능성 표면구조를 갖는 인공관절에 관한 기초적인 연구)

  • ;T. Yuhta
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.6
    • /
    • pp.519-526
    • /
    • 2001
  • At present. about 0.3 million and more THRs (Total Hip Replacement) in a rear are being done worldwide. The increase in mechanical failure with the increase in THR, required more revisions. Revisions compensate mainly the wear of the artificial joint frictional surface and the loosening of the cup and stem. According to recent researches, loosening is mainly due to wear debris UHMWPE (Ultra High Molecular Weight Polyethylene) from frictional surfaces . To overcome the wear problems associated with artificial joint materials , new surface structures with regular Patterns were designed and fabricated The lubrication Properties were examined to evaluate the wear of the frictional surfaces. The surface structure manifested a Pattern of "dents" with a 0.2-1.0 mm of diameter and 0.6-2.0 mm of Pitch. From the friction test of the SUS316L vs UHMWPE using the frictional tester, we found that the lubrication Performance was improved due to of drastically reduced amount of abrasion. There were optimum sizes for the diameter and the pitch of the Pattern. The results demonstrated that the lubrication properties could be improved by Patterning of the frictional surfaces. The surface Patterning was effective in preventing wear of the frictional surfaces, and the life of an artificial joint could be extended with such Patterning.

  • PDF