• 제목/요약/키워드: Steel bar corrosion

검색결과 142건 처리시간 0.024초

Corrosion Characteristics of Reinforced Steel Bar Emedded in Multiple Mortar Specimen(W/C:0.5) Aged 5 Years in Seawater

  • Moon, Kyung-Man;Takeo, Oki;Won, Jong-Pil;Park, Dong-Hyun;Kim, Yun-Hae
    • International Journal of Ocean System Engineering
    • /
    • 제3권1호
    • /
    • pp.33-37
    • /
    • 2013
  • Reinforced concrete structures have been increasingly widely used in numerous industrial fields. These structures are often exposed to severely corrosive environments such as seawater, contaminated water, acid rain, and the seashore. Thus, the corrosion problems that occur with the steel bars embedded in concrete are very important from the safety and economic points of view. In this study, the effects of the cover thickness on the corrosion properties of reinforced steel bars embedded in multiple mortar test specimens immersed in seawater for 5 years were investigated using electrochemical methods such as the corrosion potentials, polarization curves, cyclic voltammograms, galvanostat, and potentiostat. The corrosion potentials shifted in the noble direction, and the value of the AC impedance also exhibited a higher value with increasing cover thickness. Furthermore, the polarization resistance increased with increasing cover thickness, which means that the oxide film that is deposited on the surface of a steel bar surrounded by alkali environment exhibits better corrosion resistance because the water, chloride ions and dissolved oxygen have difficulty penerating to the surface of the steel bar with increasing cover thickness. Consequently, it is considered that the corrosion resistance of reinforced steel can be improved by increasing the cover thickness. However, the corrosion resistance values of a steel bar estimated by measuring the corrosion potential, impedance and polarization resistance were not in good agreement with its corrosion resistance obtained by polarization curves.

GGBFS 콘크리트에 매립된 Notch를 가진 FRP Hybrid Bar의 부식저항성 평가 (Evaluation of Anti-Corrosion Performance of FRP Hybrid Bar with Notch in GGBFS Concrete)

  • 오경석;박기태;권성준
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제20권4호
    • /
    • pp.51-58
    • /
    • 2016
  • 콘크리트 구조물은 내구성과 경제성이 확보된 건설재료이지만, 매립된 철근의 부식은 내구적인 문제뿐 아니라 구조물의 안전성에 큰 영향을 준다. 본 연구는 유리섬유와 강재를 에폭시로 일체화 시킨 FRP Hybrid Bar를 적용한 콘크리트에 대해 염해 침투 저항성과 부식수준에 따른 부착성능을 평가하였다. 이를 위해 일반 강재를 적용한 OPC(Ordinary Portland Cement)시편과 GGBFS를 30% 혼입한 시편에 대하여 부식을 0~10% 촉진하여 부착력을 평가하였다. 또한 FRP Hybrid Bar는 에폭시 코팅으로 인해 보통 상태에서는 부식 진전이 매우 작으므로 notch를 인위적으로 가하여 OPC 콘크리트에 매립시켰으며, 이후 부식실험을 수행하였다. 실험 결과, 부식된 철근의 부착력이 21% 수준으로 감소해도 FRP Hybrid Bar에 발생된 notch는 부착력에 큰 영향이 없는 것으로 평가되었다. 또한 GGBFS 콘크리트를 사용한 부재의 경우, 통과 전류가 감소하여 일반철근을 사용해도 70%이상의 부착력을 유지하고 있었다.

직경별 부식 철근과 콘크리트 간의 부착강도에 관한 연구 (Bond Strength between Steel and Concrete with Different Diameters in the Same Corrosion Rate)

  • 두여준;장인동;이혜린;이종구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 가을 학술논문 발표대회
    • /
    • pp.190-191
    • /
    • 2020
  • The bonding of steel bar to concrete is closely related to the roughness and corrosion degree of steel bar surface. The accelerated corrosion of concrete specimens with different reinforcement diameters was carried out in this test. Through the pullout test of the corroded concrete specimens, the relationship between the bond stress and the displacement of the corroded concrete specimens under the corresponding corrosion degree was obtained. The bond stress of reinforced concrete with different size and corrosion degree are compared and analyzed to find out the influence of corrosion on the bonding property of reinforced concrete.

  • PDF

철근콘크리트 구조물의 철근부식에 관한 실험 연구 (An Experimental Study on Steel Bar Corrosion of Reinforced Concrete Structure)

  • 채영석;최일윤;민인기
    • 한국안전학회지
    • /
    • 제28권6호
    • /
    • pp.29-35
    • /
    • 2013
  • The purpose of this study is to investigate the steel bar corrosion and degree of reinforced concrete bridge, and analyze the cause of corrosion occurrence. Therefore they could ensure the durability and stability as to suggest the corrosion prevention of reinforced concrete structure. To study the corrosion state reinforced concrete structure, We investigate the cover of concrete, the compressive strength by schmidt hammer, the neutralization test of site, the compressive strength of core and the measurement of neutralized depth. As the results of test, the corrosion-grade of reinforced concrete structure which the degree of corrosion is 3, 4 degree get to 18% in the used time of 40 years and the time elapsed of 25 years. Therefore the corrosion of steel bar give rise to public discussion. The degree of corrosion is serious, and the neutralization come to the cover of concrete.

콘크리트구조물 중의 철근 부식 저감을 위한 FRP Hybrid Bar의 적용성 연구 (A Study on the Application of FRP Hybrid Bar to Prevent Corrosion of Reinforcing Bar in Concrete Structure)

  • 이승태;박광필;박기태;유영준;서동우
    • 한국산학기술학회논문지
    • /
    • 제20권5호
    • /
    • pp.559-568
    • /
    • 2019
  • 최근 해양환경의 대형 SOC구조물 증가에 따른 구조물 내구성 증진에 관심이 증가되고 있다. 내구성 증진을 위해 개발된 FRP Hybrid Bar의 구조적 성능은 검증 되었으나 부식에 대한 저항성을 평가한 연구는 미흡하여 본 연구를 수행 하였다. 본 연구에서는 콘크리트 중의 철근 종류에 따른 철근부식 저항성을 평가하였다. 평가를 위하여 철근은 일반철근과 FRP hybrid Bar을 사용하였다. 시험방법은 갈바닉전류(Galvanic)와 반전지법(Half-Cell)을 사용하였으며, 철근부식 촉진을 위하여 콘크리트 내부에 염분을 0%, 1.5%, 3%, 6% 첨가하였다. 그 결과 갈바닉전류측정에서 FRP Hybrid Bar는 부식전류가 측정되지 않았다. 반면 일반철근에서는 시험 직후 부식이 발생하는 결과를 나타내었다. Half-Cell측정 결과에서도 4단계의 염분 함유량의 차이와 광물질혼화재료를 사용한 콘크리트와 일반콘크리트에 관계없이 FRP Hybrid Bar의 부식 저항성이 우수하게 나타났다. 따라서 FRP Hybrid Bar는 해양환경 및 철근부식이 예측되는 구조물용 대체 철근으로 사용이 가능하나 부착성능, 탄성계수, 절곡부의 강선 노출에 대한 처리 방법 등이 개선되면 염해로부터 철근부식 저항성 확보를 요구하는 구조물에 사용 할 수 있는 우수한 소재로 판단된다.

몰타르 시험편(W/C:0.4) 내부철근의 분극특성에 미치는 재령년수의 영향 (The Effect of Passing Aged Years to the Polarization Characteristics of Embedded Steel Bar of Mortar Specimen(W/C:0.4))

  • 문경만;원종필;박동현;이성열;정진아;이명훈;백태실
    • Corrosion Science and Technology
    • /
    • 제13권1호
    • /
    • pp.20-27
    • /
    • 2014
  • The structures of reinforced concrete has been extensively increased with rapid development of industrial society. Futhermore, these reinforced concretes are easy to expose to severe corrosive environments such as sea water, contaminated water, acid rain and seashore etc.. Thus, corrosion problem of inner steel bar embedded in concrete is very important in terms of safety and economical point of view. In this study, multiple mortar test specimen(W/C:0.4) with six types having different cover thickness each other was prepared and was immerged in seawater solution for five years to evaluate the effect of cover thickness and immersion years to corrosion property of embedded steel bar. And the polarization characteristics of these embedded steel bars was investigated using electrochemical methods such as measuring corrosion potential, cathodic polarization curve, and cyclic voltammogram. At the beginning of immersion, the corrosion potentials exhibited increasingly nobler values with increasing cover thickness. However, after immersed for 5 years, the thicker cover of thickness, the corrosion potentials shifted in the negative direction, and the relationship between corrosion potential and cover thickness was not in good agreement with each other. Therefore, it is considered that the thinner cover of thickness, corrosive products deposited on the surface of the embedded steel bar plays the role as a resistance polarization which is resulted in decreasing the corrosion rate as well as shifting the corrosion potential in the positive direction. As a result, it seemed that the evaluation which corrosion possibility of the reinforced steel would be estimated by only measuring the corrosion potential may not be a completely desirable method. Therefore, it is suggested that we should take into account various parameters, including cover thickness, passed aged years as well as corrosion potential for more accurate assessment of corrosion possibility of reinforced steel which is exposed to partially or fully in marine environment for long years.

다전극 배열을 이용한 콘크리트 매립 철근의 위치탐사 (Probing of Steel Bar Location inside Concrete using Multi-electrode Array)

  • 이형우;임홍철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.663-666
    • /
    • 2003
  • Using numerical analysis modeling of Multi-electrode Array that could be applied to the corrosion state measurement of a reinforcing steel bar in concrete, the steel bar location inside concrete can be probed by the investigation of the change of the measured impedance from concrete surface determined by the electrical impedance of interface between the steel bar and concrete, the electrical resistivity of concrete, the array of electrodes and the relative location and diameter of the steel bar.

  • PDF

방청제 혼입 프라이머 및 단면복구모르타르를 사용한 철근부식보수공법의 철근방청성능 평가 (Evaluation for Corrosion Prevention Properties of Steel Bar Corrosion Repair Method Composed of Primer and Section Restoration Mortar with Corrosion Inhibitor)

  • 조봉석;장재봉;장종호;김용로;강석표;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.793-796
    • /
    • 2004
  • In domestic, various repair materials and method systems to keep up with these reinforced concrete deteriorated due to salt damage, carbonation. chemical decay et. being developed and applied. However, present polymer cement mortar applied to section restoration system cause the problem of long-term working and economica] efficiency. because that is divided into two process of liquid corrosion prevention agent and polymer cement mortar. In this background, accelerated test with due regard to $3\%$ NaCl soaking and autoclave cure was performed to confirm steel bar corrosion prevention properties of polymer cement mortar mixed with corrosion prevention agent of powdered type. In conclusion. we confirmed application possibility and excellency of steel bar corrosion prevention properties of polymer cement mortar mixed with corrosion prevention agent of powdered type comparing general polymer cement mortar applied to section restoration system of present study.

  • PDF

모르타르(W/C:0.6)의 철근의 부식전위와 양극분극 및 임피던스 특성에 미치는 재령 년수 (Effect of Period of Immersion on Corrosion Potential, Anodic Polarization, and Impedance Characteristics of Reinforced Steel in Mortar (W/C: 0.6))

  • 정재현;문경만;이성열;이명훈;백태실
    • 한국해양공학회지
    • /
    • 제30권4호
    • /
    • pp.327-333
    • /
    • 2016
  • Reinforced concrete structures have found wide usage in land and maritime applications. However, the corrosion of reinforced concrete has been recognized as a serious problem from economic and safety standpoints. In previous studies, the corrosion behavior of the inner steel bar embedded in mortar (W/C: 0.4, 0.5) was investigated using electrochemical methods. In this study, multiple mortar test specimens (W/C: 0.6) with six different cover thicknesses were prepared and immersed in flowing seawater for five years. Subsequently, equations related to the cover thickness, period of immersion, and corrosion characteristics of the embedded steel bar were evaluated using electrochemical methods. Prior to immersion, the corrosion potentials indicated an increase with increasing cover thickness, and after five years, all corrosion potentials demonstrated a trend in the positive direction irrespective of the cover thickness. However, the relationships between the corrosion potential and cover thickness were not in complete agreement. Furthermore, after five years, all of the corrosion potentials indicated values that were nobler compared to those obtained prior to immersion, and their corrosion current densities also decreased compared to their values obtained prior to immersion. It was considered that the embedded steel bar was easily corroded because of the aggression of water, dissolved oxygen, and chloride ions; a higher W/C ratio also assisted the corrosion process. The corrosive products deposited on the surface of the steel bar for five years cast a resistance polarizing effect shifting the corrosion potential in the nobler direction. Consequently, it was considered that the W/C ratio of 0.6 showed nearly same results as those of W/C of 0.4 and 0.5. Therefore, the corrosion potential as well as various parameters such as the cover thickness, period of immersion, and W/C ratio must be considered at once for a more accurate evaluation of the corrosion property of reinforced steel exposed to marine environment for a long period.

고온의 인공해수 중 12Cr강의 부식피로특성에 관한 연구 (Corrosive Characterisics of 12Cr Alloy Steel and Fatigue Characteristics of the Artificially Degraded 12Cr Alloy Steel)

  • 조선영;김철한;배동호
    • 대한기계학회논문집A
    • /
    • 제25권5호
    • /
    • pp.772-778
    • /
    • 2001
  • In this study, corrosion fatigue characteristics of 12Cr alloy steel were investigated in 3.5wt.% NaCl solution of 150$^{\circ}C$ and 4.5bar. Behavior of corrosion fatigue cracks was measured by the indirect compliance method and compared with the results in distilled water and in air. 1) 12Cr alloy steel was susceptible to temperature. Its susceptibility was increased as the temperature was increased. 2) The crack growth characteristics of 12Cr alloy steel in distilled water were similar to 3.5wt.% NaCl solution. 3) The temperature of solution affects to the crack growth characteristics of 12Cr alloy steel. In corrosion solutions of 4.5bar, 150$^{\circ}C$, fracture surfaces of corrosion fatigue crack growth at a/W=0.3 was showed the trans-granular fracture suface. As the crack grew up, it was changed to inter-granular type. In condition of high temperature, The crack growth behaviors of 12Cr alloy steel were remarkable.