• Title/Summary/Keyword: Steam temperature process

Search Result 259, Processing Time 0.021 seconds

Evaluation of CO2 desorption efficiency of scrubber absorption system in Liquor Plant (주류공정 내 흡수시스템 CO2 탈리 효율 평가)

  • Park, Il-Gun;Park, Hyung-June;Lee, June-Hyung;Kim, Heung-Rae;Lee, Ju-Yeol
    • Journal of the Korean Applied Science and Technology
    • /
    • v.37 no.2
    • /
    • pp.173-182
    • /
    • 2020
  • In this study, amino acid salt absorbents were applied to remove and capture high concentrations of CO2 in liquor factories and regeneration performance was confirmed. In order to evaluate the effective treatment of the desorption process, two methods(Hot plate and Steam) were compared at the laboratory scale. As a result, hot plate and Steam. Hot plate methods regeneration efficiency was about 10% and Steam methods was about 60%. The Steam-Tower condition was evaluated by installing a 100㎥/min flow rate scrubber absorption system in the liquor factory. As a result, it was established that the absorbent flow rate was below 4L/min and the steam temperature was above 160℃. Finally regeneration performance was confirmed as 85.5%.

Analysis of Design and Part Load Performance for gas Turbine Cogeneration Systems (가스터빈 열병합발전 시스템의 설계점 설정 및 부분부하 성능해석)

  • 김동섭;노승탁
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.8
    • /
    • pp.2167-2176
    • /
    • 1994
  • This paper presents some useful design criteria for the turbine cogeneration system through both the design and off-design analysis. Comparative analysis of the part load performance is carried out for several gas turbines which have different design parameters represented by the turbine inlet temperature and pressure ratio. It is shown that the variation in part load efficiency considerably depends on the design parameter. The off-design operation of the heat recovery steam generator is simulated by introducing adequate assumptions for the heat transfer process. It is turned out that the design parameters of heat recovery steam generator should be determined by considering the favorable operation at the off-design conditions.

A Preliminary Study on Mortar Strength Development by Low-Pressure Steam Curing Method (상압증기양생에 의한 모르터의 강도발현성에 관한 기초연구)

  • 곽영근;정상진
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1994.10a
    • /
    • pp.194-199
    • /
    • 1994
  • Frefab Construction known for durable construction skill prompting high productivity in developed country is not yet settled in Korea. This situation of prefab construction results from lack of skill, specialists and quality control. In introducing skill, all equipments are thoughtlessly imported without inside eudeavor for development. Regardless of production of goods, basic study for production of goods, construction and structure is not abailable. The object of this study is curing method in the production process of PC concrete product. From change of curing temperature and curing period which would be factors of product quality in PC concrete production, and research of optimized steam curing condition from relations between curing condition and strength development, basic data of concrete steam curing method will be presented.

  • PDF

Alkali-Treatment of Polyester/Cotton Blend Fabric (Polyester/면 혼방직물의 alkali 처리가공)

  • Lee, Suk-Young;Cho, Hwan
    • Textile Coloration and Finishing
    • /
    • v.3 no.3
    • /
    • pp.6-14
    • /
    • 1991
  • To develop an one-bath process for weight-reduction and mercerization of polyester/cotton fabric, concentrated NaOH solution was padded and steam-treated at high temperature. Following results which can be used commercially are obtained. (1) Steaming temperature of 110-12$0^{\circ}C$ is most efficient. (2) Optimum concentration of NaOH solution is 15-20%. (3) Most favorable weight-reduction is 20% in the aspect of fabric handle, and under this treating condition, dye exhaustion onto the mercerized cotton fiber is also increased to 40% or more. From above results, we believe that the economical and concurrent weight-reduction and mercerzation of polyester/cotton fabric can be realized. Moreover, with continuous treatment by pad-steam procedure, it is expected that this is, also, advantageous for the improvement of fabric quality and productivity.

  • PDF

An Experimental Study on the Design-Concrete for Precast Concrete (문양 콘크리트의 프리캐스트화를 위한 실험적 연구)

  • Kim Jae-Eun;Gong Min Ho;Kim Kwang Ki;Cho Sang-Young;Jung Jae Young;Jung Sang-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • v.y2004m10
    • /
    • pp.11-14
    • /
    • 2004
  • The object of this study is vibrating compaction and curing method in the production process of Design concrete for precast concrete(Design-PC) product. From change of vibrating compaction time and pre-curing time. curing temperature which would be factors of product quality in Design-PC concrete production. and research of optimized steam curing condition from relations between curing condition and strength development. basic data of vibrating compaction time and concrete steam curing method for Design-PC will be presented.

  • PDF

High Purity Hydrogen Production by Redox Cycle Operation (산화-환원 싸이클 조업에 의한 고순도 수소생성)

  • Jeon, Bup-Ju;Park, Ji-Hun
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.21 no.5
    • /
    • pp.355-363
    • /
    • 2010
  • High purity hydrogen, 97-99 vol.%, with CO at just ppm levels was obtained in a fixed bed of iron oxide employing the steam-iron cycle operation with reduction at 823K and oxidation in a steam-$N_2$ mixture at 773K TGA experiments indicated that temperature of the reduction step as well as its duration are important for preventing carbon build-up in iron and the intrusion of $CO_2$ into the hydrogen product. At a reduction temperature of 823K, oxide reduction by $H_2$ was considerably faster than reduction by CO. If the length of the reduction step exceeds optimal value, low levels of methane gas appeared in the off-gas. Furthermore, with longer durations of the reduction step and CO levels in the reducing gas greater than 10 vol.%, carbidization of the iron and/or carbon deposition in the bed exhibited the increasing pressure drop over the bed, eventually rendering the reactor inoperable. Reduction using a reducing gas containing 10 vol.% CO and a optimal reduction duration gave constant $H_2$ flow rates and off-gas composition over 10 redox reaction cycles.

Development of Plastic Film Type Water Level Sensor for High Temperature (고온용 플라스틱 필름 수위 센서 개발)

  • Lee, Young Tae
    • Journal of the Semiconductor & Display Technology
    • /
    • v.18 no.4
    • /
    • pp.124-128
    • /
    • 2019
  • In this paper, a high temperature plastic film type water level sensor was developed. The high temperature film type water level sensor was manufactured by attaching a copper film to a polyimide film which can be used for a long time at 250℃, by laminating process and patterning the electrode by etching process. For the performance evaluation of the developed film type water level sensor, the temperature dependence of the capacitance was measured, and the deformation was examined after standing for 8 hours in 150℃ air. The developed film type water level sensor can be used at up to 150℃, and can be applied to electric ports and steam devices.

Operating Characteristics on Coupling of Fuel-Cell System with Natural Gas Reformer (천연가스 개질기와 연계한 연료전지시스템의 운전특성)

  • Park, Se-Joon;Choi, Young-Sung;Hwang, Jong-Sun;Lee, Kyung-Sup
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.639-643
    • /
    • 2009
  • A reformer, which produces hydrogen from natural gas, plays a major role for producing quality hydrogen to fuel-cell system. In this paper, fuel processor is designed to deliver hydrogen(75%) from the reformer to 200W fuel-cell system, and the electrical output power of the fuel-cells is examined by being injected different hydrogen concentrations to the system. We verified that the output power characteristics of the fuel-cells with 75% reformed hydrogen was lower about 7% than the case of pure hydrogen supplied. The type of reformer in this experiment takes SMR(Steam methane reforming) process, and the temperature variation characteristics of reforming process by reactions are examined in operation.

Studies on the heat performance and stability for multi spray type desuperheater of the power plant (발전소용 다중 스프레이형 과열저감기의 열성능 및 안정성에 관한 연구)

  • Cho, Nam-Cheol;Lee, Deok-Gu;Lee, Chae-Moon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.185-190
    • /
    • 2011
  • The important use of the desuperheater(multi spray type) changes the superheated steam into the saturated steam. It is more efficient and suitable for using the process. Also, it is more convenient and stable regarding the process temperature control. In this study, transient and quasi-static analysis were done for the evaluation of structural integrity of the multi spray type desuperheater of the power plant. Computational analysis was used to calculate the thermal stress, and the vibration test was done to evaluate the structural stability. This paper is verified by analysis that water spray nozzle(${\phi}=28mm$) shows the best ability. The results show that structural stability of the desuperheater under the real operating condition was proven.

  • PDF

Corrosion Failure Analysis of Condensate Pre-Heater in Heat Recovery Steam Generator (배열회수보일러 복수예열기 부식 파손 분석)

  • Chae, Hobyung;Kim, Woo Cheol;Kim, Heesan;Kim, Jung-Gu;Kim, Kyung Min;Lee, Soo Yeol
    • Corrosion Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.69-76
    • /
    • 2021
  • In this work, we have performed a corrosion failure analysis of a leaking tube connected to an upper header of a condensate pre-heater in a heat recovery steam generator. It was revealed that the leakage position in the tube was the location where the materials were easily vulnerable due to tensile residual stresses induced by the material manufacturing process and welding process. In addition to an imbalance in the module induced by temperature difference during operation of the pre-heater, the weight of the modules and thermal fatigue provoked a type of stress of tensile-tensile fatigue on the tube. Thus, the leakage position of the pre-heater was exposed to the tensile stress on the inner surface of the tube facing the gas, which rendered the unstable oxide layer susceptible to corrosion and the formation of pits on the water side. The cracks propagated along with the degraded microstructure in a transgranular cracking mode under fatigue loading and finally resulted in water leakage.