• Title/Summary/Keyword: Steam method

Search Result 1,041, Processing Time 0.025 seconds

New Seat Design and Finite Element Analysis for Anti-Leakage of Globe Valve (글로브 밸브의 누설방지를 위한 시트 설계 및 유한요소해석)

  • Lee, Sung Ho;Kang, Gyeong Ah;Kwak, Jae-Seob;An, Ju Eun;Jin, Dong Hyun;Kim, Byung Tak
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.1
    • /
    • pp.81-86
    • /
    • 2016
  • The valves used to control or shut off the flow through a pipeline can be divided into many different types, including gate valves, globe valves, and check valves. Globe valves, in particular, have excellent properties, and because they can easily control the flow under high-pressure conditions, they are generally used in LNG ship and steam pipelines. In this paper, a method for changing the shape of a seat was suggested to solve the valve leakage problem from a structural perspective. In addition, the stress distribution and directional deformation were compared for each model. The suggested models were thus validated, and the optimized seat structure, which includes a self-supporting capability for decreasing the amount of leakage, was determined.

Development of Inter-Turn Short Circuits Sensor for Field Winding of Synchronous Generator

  • Nam J-H;Jeon Y-S;Choe G-H;Lee S-H;Jeong S-Y;Yoo B-Y;Ju Y-H;Lee Y-J;Shin W-S
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.56-59
    • /
    • 2001
  • An effective method of detecting inter-turn short circuits on round rotor windings is described. Shorted-turns can have significant effects on a generator and its performance. A method of detecting inter-turn short circuits on rotor windings is described. The approach used is to measure the rate of change of the air-gap flux density wave when the rotor is at operating speed and excitation is applied to the field winding. The inter-turn short circuits sensor for synchronous generator's field winding has been developed. The sensor, installed in the generator air-gap, senses the slot leakage flux of field winding and produces a voltage waveform proportional to the rate of change of the flux. For identification of reliability for sensor, a inter-turn short circuits test was performed at the West-Inchon combined cycle power plant on gas turbine generator and steam turbine generator. This sensor will be used as a detecting of shorted-turn for field winding of synchronous generator. The purpose of this paper is to describe the design and operation of a sensitive inter-turn short circuits detector. In this paper, development of inter-turn short circuits sensor for field winding of synchronous generator and application in a field.

  • PDF

Effect of Pore Structure of Activated Carbon Fiber on Mechanical Properties (활성탄소섬유의 기공구조가 기계적 특성에 미치는 영향)

  • Choi, Yun Jeong;Lee, Young-Seak;Im, Ji Sun
    • Applied Chemistry for Engineering
    • /
    • v.29 no.3
    • /
    • pp.318-324
    • /
    • 2018
  • In this study, PAN (polyacrylonitrile) based activated carbon fibers were prepared by water vapor activation method which is a physical activation method. Activation was performed with temperature and time as parameters. When the activation temperature reached 700, 750 and $800^{\circ}C$, the activation was carried out under the condition of a water vapor flow rate of 200 ml/min. In order to analyze the pore structure of activated carbon fibers, the specific surface area ($S_{BET}$) was measured by the adsorption/desorption isotherm of nitrogen gas and AFM analysis was performed for the surface analysis. Tensile tests were also conducted to investigate the effect of the pore structure on mechanical properties of fibers. As a result, the $S_{BET}$ of fibers after the activation showed a value of $448{\sim}902m^2/g$, the tensile strength decreased 58.16~84.92% and the tensile modulus decreased to 69.81~83.89%.

Research Trend of Traditional Chinese Medicine in the Treatment of Restless Legs Syndrome (하지불안증후군의 중의치료 연구 동향)

  • Kim, Tae-Heon;Jung, Jin-Hyung;Choi, Yun-Hee;Kim, Bo-Kyung
    • Journal of Oriental Neuropsychiatry
    • /
    • v.25 no.2
    • /
    • pp.165-178
    • /
    • 2014
  • Objectives: This study was conducted to assess how Traditional Chinese Medicine treats the medical condition of Restless Legs Syndrome (RLS). Methods: The authors searched for relevant articles through the CNKI (China National Knowledge Infrastructure-www.global.cnki.net) with the following keywords: The main search was for the term 'RLS,' with supportive words added such as 'Acupunture', 'Acupoint', 'Meridian', 'Moxibustion', 'Massage', 'Acupoint injection'. Our search yielded a total of 233 articles; there were a total of 71 articles related to clinical fields. We then analyzed the chosen articles using a number of criteria including the study type used, the treatment method utilized, and the main effect of the treatment. Results: The 71 analyzed articles utilized the following type of study design: 4 were classified as Quasi-randomised trial, 22 as Randomized Controlled Trial, and 45 as a case report. Regarding the treatment used for RLS, 25 studies examined a single treatment modality, while 46 studies examined a complex treatment modality. There were a total of 10 types of acupuncture treatment used in treating RLS; several massage and acupoint injection method were also found. Finally, there were a few studies that used Moxibustion, as well as several supportive treatments like Cupping, Moxibustion, Steam-Washing, TDP (Teding Dancibo Pu) were found. Conclusions: Traditional Chinese Medicine has used a variety of different study designs and treatments vis-a-vis RLS. These treatments are also used to treat the condition in South Korea.

A Study on the High Temperature Creep Crack Growth Properties for Steam Turbine Rotor Steel under Static and Cyclic Loading Condition (화력 발전용 고압 로터강의 정하중 및 변동하중하의 고온 크립 균열전파 특성에 관한 연구)

  • O, Se-Gyu;Jeong, Sun-Eok
    • Journal of Ocean Engineering and Technology
    • /
    • v.5 no.2
    • /
    • pp.207-207
    • /
    • 1991
  • The crack length measurements by electrical potential(EP) method for 1% Cr-Mo-V and 12%Cr steel of 0.5T-CT specimen were performed at $500^{\circ}C, 600^{\circ}C 700^{\circ}C$, and an applicability of stress intensity factor($K_I$), net section stress($\sigma_{net}$), $C^*$-ingegral and $C_t$ parameter was studied to measure creep crack growth rate(da/dt) with side groove and without side groove under static and cyclic loading condition. The experimental result could be summarized as follows: 1) Crack measurement by EP method was available and coincided with the Johnson,s analytical equation. 2) da/dt by $K_I$ and $\sigma_{net}$ was not adequate because of the wide scatter band according to load and temperature, but $C^*$-integral, except for transition region, was adequate. 3) $C_t$ parameter showed the best fitted line through total creep region without relating with both temperature and load condition. 4) Under the cyclic loading condition, $C_t$ parameter was proper to extimate da/dt. And it was shown that da/dt for 1% Cr-Mo V steel under the static condition(R=1) was 1.16 times faster than the case under cyclic loading(R=0), and for 12% Cr steel, 1.43 times.

A Study on the High Temperature Creep Crack Growth Properties for Steam Turbine Rotor Steel under Static and Cyclic Loading Condition (화력 발전용 고압 로터강의 정하중 및 변동하중하의 고온 크립 균열전파 특성에 관한 연구)

  • O, Se-Gyu;Jeong, Sun-Eok
    • Journal of Ocean Engineering and Technology
    • /
    • v.5 no.2
    • /
    • pp.67-75
    • /
    • 1991
  • The crack length measurements by electrical potential(EP) method for 1% Cr-Mo-V and 12%Cr steel of 0.5T-CT specimen were performed at $500^{\circ}C, 600^{\circ}C 700^{\circ}C$, and an applicability of stress intensity factor($K_I$), net section stress($\sigma_{net}$), $C^*$-ingegral and $C_t$ parameter was studied to measure creep crack growth rate(da/dt) with side groove and without side groove under static and cyclic loading condition. The experimental result could be summarized as follows: 1) Crack measurement by EP method was available and coincided with the Johnson, s analytical equation. 2) da/dt by $K_I$ and $\sigma_{net}$ was not adequate because of the wide scatter band according to load and temperature, but $C^*$-integral, except for transition region, was adequate. 3) $C_t$ parameter showed the best fitted line through total creep region without relating with both temperature and load condition. 4) Under the cyclic loading condition, $C_t$ parameter was proper to extimate da/dt. And it was shown that da/dt for 1% Cr-Mo V steel under the static condition(R=1) was 1.16 times faster than the case under cyclic loading(R=0), and for 12% Cr steel, 1.43 times.

  • PDF

Application of Risk-Based Inspection with Financial Risk for a Petrochemical Process (석유화학공정에서 재정적 위험도에 의한 위험기반검사의 적용)

  • Kim, Tae-Ok;Lee, Joong-Hee;Choi, Sung-Kyu;Lee, Hern-Chang;Jo, Ji-Hoon
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.4
    • /
    • pp.53-60
    • /
    • 2009
  • For the case of the facilities using utilities such as cooling water and steam, risk of the facilities is zero because the consequence of failure (COF) through equipment damage area is zero. Therefore, to improve the estimation method of the risk by COF through equipment damage area in the risk-based inspection (RBI), this study developed the procedures of RBI, in which the risk was estimated by COF through financial loss. And, the RBI program (KS-RBI Ver 3.1) was developed to establish inspection interval based on the risk of the facilities estimated by COF through equipment damage area and financial loss, simultaneously, and the developed RBI program was applied to a petrochemical process. As a result, risks of the facilities estimated by COF through financial loss were similar to risks by COF through the equipment damage area. But, for the case of the facilities using utilities or expensive facilities, the estimation method of the risk by COF through financial loss was more accurate than through equipment damage area.

  • PDF

Characteristics of LaCo1-xNixO3-δ Coated on Ni/YSZ Anode using CH4 Fuel in Solid Oxide Fuel Cells

  • Kim, Jun Ho;Jang, Geun Young;Yun, Jeong Woo
    • Journal of Electrochemical Science and Technology
    • /
    • v.11 no.4
    • /
    • pp.336-345
    • /
    • 2020
  • Nickel-doped lanthanum cobalt oxide (LaCo1-xNixO3-δ, LCN) was investigated as an alternative anode material for solid oxide fuel cells. To improve its catalytic activity for steam methane reforming (SMR) reaction, Ni2+ was substituted into Co3+ lattice in LaCoO3. LCN anode, synthesized using the Pechini method, reacts with yttria-stabilized zirconia (YSZ) electrolyte at high temperatures to form an electrochemically inactive phase such as La2Zr2O7. To minimize the interlayer by-products, the LCN was coated via a double-tape casting method on the Ni/YSZ anode as a catalytic functional layer. By increasing the Ni doping amount, oxygen vacancies in the LCN increased and the cell performance improved. CH4 fuel decomposed to H2 and CO via SMR reaction in the LCN functional layer. Hence, the LCN-coated Ni/YSZ anode exhibited better cell performance than the Ni/YSZ anode under H2 and CH4 fuels. LCN with 12 mol% of Ni (LCN12)-modified Ni/YSZ anode showed excellent long-term stability under H2 and CH4 conditions.

A New Loose Parts Monitoring Technique for Nuclear Steam Supply System based on High Resolution Sensor Array Signal Processing (고해상도 센서어레이 신호처리법을 이용한 원자력발전소 핵증기 공급계통의 새로운 금속파편 진단기법)

  • Rhee, Ill-Keun;Choi, Jae-Won
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.6
    • /
    • pp.76-84
    • /
    • 1997
  • Loose parts monitoring system(LPMS), which is used to detect metallic loose parts in the nuclear power plant, plays an important role in safe and reliable operation of the plant. To prevent from the damage due to the loose parts, most domestic nuclear power plants are using, or planning to use LPMS. However, these LPMS's, which are all invented from overseas and thereby depend on the oversea technologies, are very expensive, and are known to be inefficient to diagnose loose parts due to the lack of fundamental know-how of LPMS. Therefore, the main purpose of this paper is to propose and to realize a new loose parts localization algorithm which is simple and efficient enough even for the inexperienced operators to diagnose loose parts accurately and promptly. Considering practical nuclear power plant circumstances, some simulations for estimating the loose parts location have been done. The results show that the proposed method, called a modified circle intersection method, performs high resolved loose parts localization with 3.4% of error.

  • PDF

A Study on Application Analysis Using RETRAN Computer Code for the Environmental Qualification Flood Analysis Following the Main Feed Water Line Break (주급수관 파단에 따른 내환경검증 침수분석용 전산코드 RETRAN의 적용 해석연구)

  • Park, Young-Chan;Cho, Cheon-Hwey;Hong, Sung-In
    • Journal of Energy Engineering
    • /
    • v.16 no.3
    • /
    • pp.103-112
    • /
    • 2007
  • Flood issue for nuclear power plants designed and built in 1970 is extremely severe for main steam header compartment and main feedwater line region of intermediate building and lower floor. A calculation for flood level at the main feedwater line isolation compartment is now performing by hand calculation. But, this methodology is quite conservative assumption. The goal of this study was to develop method to analyze flowrate using the RETRAN-3D computer code, and the developed method was applied to flood level analysis following main feedwater line break. As a result of analysis, flood level was low remarkably.